Tender For Replacement Of Defective Existing Fitting With Led 18 Watts Pll And Provision Of Power Points And Other Allied Work To Be Carried Out In Room No. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 And Lab No. 26, 22, 17, 306, 310, 311, 31, Delhi-Delhi

Delhi University has published Tender For Replacement Of Defective Existing Fitting With Led 18 Watts Pll And Provision Of Power Points And Other Allied Work To Be Carried Out In Room No. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 And Lab No. 26, 22, 17, 306, 310, 311, 31. Submission Date for this Tender is 18-09-2023. Cushioning Supplies Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

39480216
Tender For Replacement Of Defective Existing Fitting With Led 18 Watts Pll And Provision Of Power Points And Other Allied Work To Be Carried Out In Room No. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 And Lab No. 26, 22, 17, 306, 310, 311, 31
Open Tender
Indian
Delhi
Delhi
18-09-2023

Tender Details

Replacement Of Defective Existing Fitting With Led 18 Watts Pll And Provision Of Power Points And Other Allied Work To Be Carried Out In Room No. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 And Lab No. 26, 22, 17, 306, 310, 311, 312, 313 In Department Of Botany And Seminar Hall And Rooms Of Conference Centre, University Of Delhi ; 1 S / F The Following Size / Modules G.I Box Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Reqd. 2 6 Module 3 8 Module 4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 5 1 X 1.5 Sq.Mm 6 2 X 2.5 Sq.Mm 7 2 X 4 Sq.Mm 8 2 X 6 Sq.Mm 9 Wiring For Circuit / Submain Wiring Longwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire 10 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 11 5 / 6 Amps Switch 12 3 Pin 5 / 6 Amps Socket Outlet 13 15 / 16 Amps Switch 14 6 Pin 15 / 16 Amps Socket Outlet 15 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 16 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group C 17 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 18 Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3½ X 120 Sq. Mm 19 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 200 A, 35 Ka Tpmccb 20 Supplying And Fixing Of 18 Watts Led 4 Pin Pll 1700 Lumens Tube Dimension 1200X32x26 With Colour 6500 In The Existing Fitting Including Making Connection Etc. As Required At Site. ( Philips ) 21 Finding And Detecting Location Of Underground Lt Cable With Flc Machine Including Excavation, Pin Pointing, Fault , Refilling After Repair Of Ground At Marked Fault As Required At Site. 22 Making Provision Of Digging Out The Fault Location Upto 10 Mtr For Making Connection Straight Through Joint By Tracing Out The Loop And Then Refilling The Trench After Restoring The Electric Supply Etc. As Required. 23 Supplying, Fixing And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Armoured Conductor Power Cable Confirming To 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation Sand Cushioning , Protective Covering , Refilling The Same Etc. As Required. 3½ X 185 Sq. Mm 24 Supplying And Fixing Following Rating, Tpn Mcb 415V In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Required. 25 Servicing / Cleaning / Meggering / Checking Of Load Balancing / Checing With Ton Tester Of Existing Panel I / C Removing The Dust And Carbonized And Dress Up The Hanging Wire Along With Thimble If Necessary Etcas Required At Site. 26 S / F Of Single Box Type Fitting Complete With All Accessories I / C Making Connection Etc. As Required. Tmc 502 1Xt- Led 22W P3242 I / C Having 1 Nos. Of Stellar Bright 20Watts Led Tubelight In The Existing Fitting As Required. 27 Supplying And Fixing Of 48 Ceiling Fan Including 3 Fan Rod And Making Connection Etc. As Required At Site. ( Crompton / Havells )

Key Value

Document Fees
INR 500 /-
EMD
INR 14391.0 /-
Tender Value
INR 7.19 Lakhs /-

BOQ Items

Name of Work:Replacement of defective existing fitting with LED 18 watts PLL and provision of power points and other allied work to be carried out in room no. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 and lab no. 26, 22, 17, 306, 310, 311, 312, 313 in Department of Botany and Seminar Hall and rooms of Conference Centre, University of Delhi
Sl. No. Item Description
1S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd.
26 Module
38 Module
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
51 x 1.5 sq.mm
62 x 2.5 sq.mm
72 x 4 sq.mm
82 x 6 sq.mm
9Wiring for circuit/ submain wiring longwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 16 sq. mm earth wire
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
115/6 amps switch
123 pin 5/6 amps socket outlet
1315/16 amps switch
146 pin 15/16 amps socket outlet
15Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
16Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.Group C
17Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
18Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm
19Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 35 KA TPMCCB
20Supplying and fixing of 18 watts LED 4 pin PLL 1700 lumens tube dimension 1200x32x26 with colour 6500 in the existing fitting including making connection etc. as required at site. (Philips)
21Finding and detecting location of underground LT cable with FLC machine including excavation, pin pointing, fault , refilling after repair of ground at marked fault as required at site.
22Making provision of digging out the fault location upto 10 mtr for making connection straight through joint by tracing out the loop and then refilling the trench after restoring the electric supply etc. as required.
23Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation sand cushioning , protective covering , refilling the same etc. as required. 3½ X 185 sq. mm
24Supplying and fixing following rating, TPN MCB 415V in the existing MCB DB complete with connection, testing and commissioning etc. as required.
25Servicing/ cleaning/ meggering/ checking of load balancing/ checing with ton tester of existing panel i/c removing the dust and carbonized and dress up the hanging wire along with thimble if necessary etcas required at site.
26S/F of single box type fitting complete with all accessories i/c making connection etc. as required. TMC 502 1XT- LED 22W P3242 i/c having 1 Nos. of stellar bright 20Watts LED tubelight in the existing fitting as required.
27Supplying and fixing of 48" ceiling fan including 3" fan rod and making connection etc. as required at site. (Crompton/ Havells)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail