Tender For Repair Maintenance And Improvement Em Installatoins Lt Oh Distribution System Lt Ug Cablese Apfc Panels Switchgears And Other Misc Em Works At Palampur Mil Stn, palampur-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance And Improvement Em Installatoins Lt Oh Distribution System Lt Ug Cablese Apfc Panels Switchgears And Other Misc Em Works At Palampur Mil Stn. Submission Date for this Tender is 03-10-2023. Power Factor Panel Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39477285
Corrigendum : Tender For Repair Maintenance And Improvement Em Installatoins Lt Oh Distribution System Lt Ug Cablese Apfc Panels Switchgears And Other Misc Em Works At Palampur Mil Stn
Open Tender
Indian
Himachal Pradesh
palampur
03-10-2023

Tender Details

Repair Maintenance And Improvement Em Installatoins Lt Oh Distribution System Lt Ug Cablese Apfc Panels Switchgears And Other Misc Em Works At Palampur Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINTENANCE AND IMPROVEMENT E/M INSTALLATIONS, LT OH DISTRIBUTION SYSTEM, LT UG CABLES, APFC PANELS, SWITCHGEARS AND OTHER MISC E/M WORKS AT PALAMPUR MIL STN
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
2All as per item No. 1 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre.
3Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed.
4Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
5Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
6M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brickcomplete all as specified and as directed.
7S&F steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolt, nut and screws as specified 410 SP-55 (9 mter long) including taking down old damaged pole of any type and size, including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface, above PCC benching including with writing of pole No with letters/figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting complete all as specified and directed.
8M&L PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregates as in foundation filling and mass concrete complete all as specified and directed.
9M&L PCC 1:3:6 type C-1 (using 20mm thick mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including form work, complete all as specified and directed.
10Cutting and removing existing wild grass, vegetation, creepers, small plants/bushes etc. clamping up towards the poles and stays etc including cleaning bottom surface area of pole & stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
11S&F in replacement MCCB, AC, 415 volts, 63 amp, 16 KA, 3 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
12S&F in replacement MCCB, AC, 415 volts, 125 amp, 25 KA, 3 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
13S&F in replacement MCCB, AC, 415 volts, 160 amp, 36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
14S&F in replacement MCCB, AC, 415 volts, 200 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
15S&F in replacement MCCB, AC, 415 volts, 250 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
16S&F in replacement MCB, TPN 63 Amps, AC, 415 volts, B curve, including maknig necessary connection in existing panel complete all as specified and directed.
17Supply and spreading 40mm thick crushed stone aggregate around two pole/four pole structure in 15 cm thickness after cleaning area by removing existing wild grass, vegetation, creepers, small plants/bushes etc. complete all as specified and directed.
18M&L disconnecting taking down and stacking the unserviceable/broken earth wire/strip of any size form the roof or from wall and removing the same from the site complete all as specified and directed.
19S&F air termination vertical type, single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead washers etc. complete and including provision of GI tubing light grade 40mm dia, 300mm long embedded in PCC block (size 30cm x 30cm x 30cm) one end and other end fitted with air termination rod complete all as specified and directed.
20S&F horizontal/down conductors, aluminium strip of size 25 x 3.15mmand incl epoxy insulator bus bar type 40mm thick at an interval of 60cm apart for lightening protection on roof and for down conductors, including all fixing arrangements and aluminium nut, bolt & washers complete as per IS-2309-1989 and testing all as specified and directed. Note:- Aluminium strip shall be jointed with rivets (minimum 04 Nos).
21Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
22S&F galvanised iron strip of size 32x6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with screws etc. and connecting up complete all as specified and directed.
23Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
24Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed.
25Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed.
26Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed.
27Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 35sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed.
28Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 25sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed.
29Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 16sq.mm 4 coreincluding taking out old unserviceable cable complete all as directed.
30Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 10sq.mm 4 coreincluding taking out old unserviceable cable complete all as directed.
31Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 16sq.mm 2 coreincluding taking out old unserviceable cable complete all as directed.
32Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 10sq.mm 2 coreincluding taking out old unserviceable cable complete all as directed.
33S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
34S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
35S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
36Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and directed.
37Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as directed.
38Supply only MCB, TP 6 to 32 amp 10 KA C curve for existing APFC panel complete all as sepcified and directed.
39Supply only MCB, TP 40 to 63 amp 10 KA C curve for existing APFC panel complete all as sepcified and directed.
40Supply only auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR rating for existing APFC panel complete all as specified and directed.
41Supply only auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR rating for existing APFC panel complete all as specified and directed.
42Supply only capacitor 440 volts 50 Hz 5 KVAR for existing APFC panel complete all as specified and directed.
43Supply only capacitor 440 volts 50 Hz 10 KVAR for existing APFC panel complete all as specified and directed.
44Supply only capacitor 440 volts 50 Hz 15 KVAR for existing APFC panel complete all as specified and directed.
45Supply only capacitor 440 volts 50 Hz 20 KVAR for existing APFC panel complete all as specified and directed.
46Supply only CT"s suitable for ampere meter 100/5A ratio for existing APFC panel complete all as specified and directed.
47Supply only CT"s suitable for ampere meter 200/5A ratio for existing APFC panel complete all as specified and directed.
48Supply only APFC relay square flush type with protection devices intelligent auto processor based on electonic controller unit 6 stages for existing APFC panel complete all as specified and directed.
49Supply only APFC relay square flush type with protection devices intelligent auto processor based on electonic controller unit 8 stages for existing APFC panel complete all as specified and directed.
50Supply only MCCB, AC, 415 volts, 100 Amp, 25KA, 4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
51Supply only MCCB, AC, 415 volts, 160 Amp, 25KA, 4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
52M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 06 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
53M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 10 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
54Taking out old unserviceable APFC panel design, supply and fixing automatic correction to unit correction to unit power factor panel complete of capacity 100 KVAR to achieved th PF from 0.9 to 1.0 with five stagging (50 + 25 + 15 + 5 +5), modular design, siemens grey colour protection IP-20 with advance micro processing based IPFC, switch option auto and manual, incomming as MCCB 200 amps four pole with rapturing design 35 KA, indicator lamp for step on indication, bus bar with copper as manufacturer"s design suitable to match the incomming current, Ref Standard: IEC 61921/IS 8623 complete all as specified and directed. Note:- (i)Rate of capacitor bank deemedto included in unit quoted rate. (ii) All type of spares such as glands, lugs, nuts, bolts etc necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (iii)Drawing of panel shall be approved by GE before fabrication.