Tender For Repair /Replacement Of Lt Oh Lines, Ug Cables And Allied Works At Nams, Amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair /Replacement Of Lt Oh Lines, Ug Cables And Allied Works At Nams. Submission Date for this Tender is 02-10-2023. Wooden Furniture Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39477182
Corrigendum : Tender For Repair /Replacement Of Lt Oh Lines, Ug Cables And Allied Works At Nams
Open Tender
Indian
Punjab
Amritsar
02-10-2023

Tender Details

Tender For Provision Of Wooden Furniture For Office Accommodation Of Dad Under Ge ( North ) Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Sep-2023 Amdt to tender Other 25-09-2023
2 16-Sep-2023 Revised BOQ BOQ 25-09-2023
3 25-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT LT OH LINES, UG CABLES AND ALLIED WORKS AT NAMS
Sl. No. Item Description
1Excavation in trenches in soft/ loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles, stay, cable, pipes etc and getting out complete all as specified.
2Excavation in trenches n. exc 1.5 mtr wide and exc 1.5mtr in depth for foundation of pole and getting out in any type of soil complete all as specified and directed.
3Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified.
4Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
5Boring of trench under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinefor road crossing GI tubing of any size for cable protection complete all as specified and directed.
6Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty)LT 1100 voltgrade with stranded aluminium conductor of size300 sqmm 3.5 core complete all as specified and directed.
7Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty)LT 1100 voltgrade with stranded aluminium conductor of size185 sqmm 3.5 core complete all as specified and directed.
8Description all as per srl item No 7.00 here-in-before but of size 120 Sqmm 3.5 core.
9Description all as per srl item No 7.00 here-in-before but of size 95 Sqmm 3.5 core.
10Description all as per srl item No 7.00 here-in-before but of size 50 Sqmm 3.5 core.
11Description all as per srl item No 7.00here-in-before but of size 10 Sqmm 4 core.
12S&F in replacement jumper wire 70sqmm single core heavy duty insulated cablesuitable for from top disc insulator to GOD and disc to disc in any lenth with complete nuts & thimbles all as required at site.
13M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal for new poles and existing poles . Including necessary form work fair finished to exposed surface.
14Material and labour for PCC 1:3:6 type C-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays , Poles etc complete all as specified and directed.
15Supply, laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. allas specified and directed by Engr in Charge ofsize 78mm outer dia and 63mm inner dia
16Description all as per srl item No 15.00 but 63 mm outer dia and 50mm inner dia
17Description all as per srl item No 15.00 but 90 mm outer dia and 75mm inner dia
18Supply & fixing in replacement of MCCB Capacity 36 KA 4 pole 400 Amps adjustable thermal and fixed magnetic type with preader and aluminium lugs all as required at site.
19Supply & fixing in replacement of MCCB Capacity 36 KA 4 pole 250 Amps adjustable thermal and fixed magnetic type with preader and aluminium lugs all as required at site.
20Supply & fixing in replacement of MCCB Capacity 16 KA 3 pole 100 Amps Fixed thermal and fixed magnetic type with preader and aluminium lugs all as required at site.
21Supply & fixing in replacement of MCCB Capacity 25 KA 4 pole 200 Amps adjustable thermal and fixed magnetic type with preader and aluminium lugs all as required at site.
22Supply & fixing in replacement of MCCB Capacity 25 KA 4 pole 160 Amps adjustable thermal and fixed magnetic type with preader and aluminium lugs all as required at site.
23Supply and fixingin replacement 40mm dia GI light grade tubingwith all fittings complete to wall or for garden lights or laid in floors for cable protection including cutting chases and necessary brick work and plaster work to making good the distributed surface complete all as specified and directed.
24Supply and erectsteel tubular swaged poles in replacement of old brokenPCC Pole complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-31 ( 9 mtr long) erecting in position including two coats of aluminum paint over a coat of red oxide primer complete all as specified/shown on drawing and as directed by Engr-in-Charge Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items.
25M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
26M&L for Pintype porcelainwhite, brown or green insulator in replacement including one galvanized mild steel spindle,two galvanisediron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
27Supply & fixing in replacement ofstay assembly comprising of 7/2.50mm galvanizedMS stay wire of reqd length, fixed to poleswith and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 215 Cm long with washers MS stay plate galvanized 230x230x6mm and stary wire complelte all as specified and as directed. Note :- Necessary Excavation and PCC shall be measured in sepereate items
28Material and labour in replacement for ACSR conductor any size drawn straight horizontal onover head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
29M&L in replacement of earthingcomplete with galvanized steel earth plate electrode600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire 4mm dia and40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth wire and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
30M&L in replacement of earthingcomplete with galvanized steel earth plate electrode600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
31M&L for earthingcomplete with Copperearth plate electrode60x60cmx3.15mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to copper strip of size 20x3 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
32Material and labour for repairing/ weldingexisting broken LT Panel door complete. Note:(i) One door shall be considered as one job. (ii) Any part/spare found defectivesuch as packing, nuts bolts,hinges & (welding machine works) etc shall be repaired/replaced for which cost shall be deemed to be included in the unit rate quoted for this item.
33Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
34Servicing and repair/maint of ACB Switch upto 800 Amp 430 Volt alongwith tripping system and carried out the fwg repair/tests made for smooth operation. (a) Cleaning and greasing of mechanism, Operation, testing of trip and close electrical and manual mode, Spring charging testing electrical and manual mode, Cleaning of panel insulater CT &PT unit, (a)Service will be carried out through Service Engineer of Manfacturer /Authorised Service Engineer only. (b)The cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc essentially required to make the breaker serviceable shall be deemed to be included in the quoted rate.
35Supply and fixing in replacement of digitaltype 96mm x 96mm Amp meter in existing LT Panel 0 to 300Amp with suitable CT and selector switch complete - 01 Set complete all as specified and directed.
36Supply and fixing in replacement of digital type 96mm x 96mm volt meter in existing LT Panel0 to 500V with selector switch complete all as specified and directed.
37Material and Labour straight through joint heats shinkable suitable forupto 95 sqmm LT3.5 core 1100 volts XLPE cable type complete all as specified and directed.
38Material and Labour straight through joint heats shinkable suitable for120 sqmm LT3.5 core 1100 volts XLPE cable type complete all as specified and directed.
39Material and Labour straight through joint heats shinkable suitable for185 sqmm to300 sqmm LT3.5 core 1100 volts XLPE cable type complete all as specified and directed.
40M&L in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letter , figures and conventional skull and bones in signal red colour and fix with MS clamps, bolts and buts of approved size, for LT 20x15 cm complete all as specified and as directed
41Supply and Fix in replacement high grade PVC LT overhead phase to phase line spacer suitable for4 lines, suitable for verticale and horizontal line complete all as specified and as directed.
42Supply and Fix in replacement high grade PVC LT overhead phase to phase line spacer suitable for5 lines, suitable for verticale and horizontal line complete all as specified and as directed.
43S & F in repairs/ replacementcable Straight joint kit for 1100 volt, out door typejoint complete with all jointing material and accessories suitable for 3.5 / 4 Core cable of size 25 sqmm to 35 sq mm all as directed.
44S & F in repairs / replacement cable Straight joint kit for 1100 volt, out door typejoint complete with all jointing material and accessories suitable for 3.5 / 4 Corecable of size 50 sq mm all as directed.
45S & F in repairs/ replacementcable end joint kit for 1100 volt, out door typejoint complete with all jointing material and accessories suitable for 3.5 corecable of size 185 sqmm to 300 sq mm all as directed.
46Supply and Install in replacement of factorymadeCPRI approved outdoor type dust and vermin proof(IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm(10 SWG) thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in Nine Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3Positioning door locking arrangementand enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following (i) MCCB 315 Amps 35KA 4pole with microprocessor release adjustable type ofas a incomer-01 (ii)MCCB 25 KA TPN 160Amp -01 (iii) MCCB 16 KA TPN 100A -03 (iv)Aluminium Busbar of 300 Amps 3 phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size
47Supply and Install in replacement of factory made outdoor type dust and vermin proof feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3 Positioning door locking arrangementand enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following (i) MCCB 315 Amps 36KA 4poleas a Incomer-01 (ii)MCCB 25 KA 4P 100A -04 (iii) MCCB 25 KA 4P 120Amp -01 (iv)Aluminium Busbar of 500 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size
48Material and labour for jointing broken/ lying on groundconductor and restrach the same with straching of upto 4 span complete with maintaing proper sagall as specified and as directed. Note :- Conductor required for jointing broken conductor shall be included in the quoted rate. No extra payment shall be made to the contractor for the same.
49Painting of PCC / Steel poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping ovdirer a coat of primer including Numbering of poles as directed by Engr-in-Charge
50S & F in replacement of ACB 800 Amps 50KA 4pole with microprocessor release drawout type complete all as specified and directed by Engineer-In-charge.
51Prunning of trees around over head HT/LT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge. Note :- All the Tools and plant shall be provided by the Contractor without any extra cost.
52Material & labour for restrainging ACSR conductor LTprovidingproper sag all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail