Tender For Purchase Of 10 Kva Online Ups For Cse Department
Tender Overview
Project Description
Supply Of 10 Kva Online Ups Supply Of 10 Kva Online Ups For Cse Dept , 10Kva Online Ups , 10 Kva Online Ups 10 Kva Online Double Conversion Igbt Based H-Bridge Pwm Technology Using Micro-Controller Under Low Supersonic Frequency 12 Khz. Switching 240 Vdc Operated Ups With Wide Range Individual Step- Down & Step- Up Transformers For Converting And Inverting With 1 Hour Backup Using 12V, 65 Ah Smf Battery-20 Nos. Input Parameters: Input Supply : 3Ø Input, 400 Vac ± 10% Input Frequency: 50 Hz. ± 1% Dc Converter: Poly Phase Converter Using 96 Amps Thyristor Module With Lc Filters Dc Volt At Charging: 270 Vdc Floating Dc Current Control: Using 75 Amps Dc Shunt Dc Fuse Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link Input Fuse Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link X 3 Nos. Output Parameters: Output Supply : 1 Ø220 Vac ±0.5% Input Frequency : 50 Hz. ± 0.1% Inverter : H-Bridge Using 2 Nos. Of 200 Amps Igbt Module Inverter Transformer: Step-Up Transformer Primary: 0 – 110 Vac, 160 Amps Secondary : 0 – 230 Vac, 40 Amps Inverter Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link Output Fuse Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link Bye-Pass Switch Provision Provided By 40 Amps Rotary Switch Display Lcd / Led Display For Output Volt, Dc Volt Led Indications : Mains On / Input Onr, Y, B Phase Failure / Phase Reversed Inverter / Ups On, Dc Low, Over Load With Onsite Installation & Demo, Onsite Delivery, Onsite Warranty
BOQ
| Sl. No. | Item Description |
| 1 | 10KVA ONLINE UPS |
| 2 | 10 KVA ONLINE UPS10 KVA online double conversion IGBT based H-Bridge PWM Technology using Micro-Controller under low supersonic frequency 12 KHz. switching 240 VDC operated UPS with wide range Individual Step- Down & Step- up Transformers for Converting and Inverting with 1 Hour backup using 12V,65 AH SMF Battery-20 nos.Input parameters:Input supply : 3Ø Input,400 VAC ± 10% Input Frequency: 50 Hz. ± 1%DC Converter: Poly phase converter using 96 Amps Thyristor module with LC filtersDC VOLT at charging: 270 VDC floatingDC Current control: using 75 Amps DC ShuntDC Fuse Protection: using 63 Amps black lite carrier with HRC Fuse linkINPUT Fuse Protection: using 63 Amps black lite carrier with HRC Fuse link x 3 nos.OUTPUT Parameters:Output supply : 1 Ø220 VAC ±0.5%Input Frequency : 50 Hz. ± 0.1%Inverter : H-Bridge using 2 nos. of 200 Amps IGBT module Inverter Transformer: Step-up TransformerPrimary: 0 – 110 VAC, 160 AmpsSecondary : 0 – 230 VAC, 40 Amps Inverter Protection: using 63 Amps black lite carrier with HRC Fuse linkOUTPUT Fuse Protection: using 63 Amps black lite carrier with HRC Fuse linkBye-Pass switch provision provided by 40 Amps rotary switchDisplayLCD / LED Display for Output volt, DC Volt LED Indications :Mains on /Input onR, Y, BPhase failure / Phase reversed Inverter / UPS ON, DC Low, Over Load With Onsite Installation & Demo, Onsite Delivery, Onsite Warranty |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed