Tender For Supply Of Laboratory Machinery And Equipment, North Goa-Goa
Tender Notice
39432780
Tender For Supply Of Laboratory Machinery And Equipment
Tender
Indian
Goa
North Goa
22-09-2023
Tender Details
Tender For supply of Laboratory Machinery And Equipment , Table Top Autoclave , Equitron Model 7407Pad Capacity 16L Working Chamber Size 12X9 Dressing Drum Size 11X9 Watts 1800 ( 230 Vac , 50 Hz ) , Ultrasonic Bath , • Make : Spectralab Ucb 30 Or Equivalent • Material: Ss304 Stainless Steel • Capacity: Approx. 3 To 5 L • Size In Mm :- 23 L X 15 B X 10 H Cms • Power : 230 V 50 Hz; Heater 150 Watts • With Heater, Lid, Basket & Two Digit Digital Timer , Drain Valve, Heater Cut Off • Time Control: 0-30Mins, Digital Control , Heating Mantle , Voltage:: 220-230V Ac Capacity: : 500-2000 Ml Model No:: Htlp-033 Temperature Range:: Up To 300°C Circuits: 1 Usage:: To Apply Heat To Containers Temperature Controller:: Energy Regulator Heating Element Material:: Glass Yarn Insulation Material:: Aluminium Body Wattage:: 450W , Ultrasonic Bath , Specification : Volume ( Ltr. ) : 5 Liters Voltage : 220V Ultrasonic Power ( W ) :120W Heat Power :75 W Adj. Power ( % ) 20-80 Temp. Range ( C ) :10-60? C Adjustable Time : 1 To 99 Minutes Frequency ( Khz ) : 60Khz Tank Size ( Mm ) :240 X 140 X 150 Unit Size ( Mm ) :350 X 250 X 230 G. W : 5.5 - 6Kg Indication : Led Digital Indication , Abbe’S Refractometer , Measurement Range Refractive Index Nd: 1.3000-1.7000 Measurement Range Dissolved Solids Brix: 0-95% Accuracy Refractive Index Nd: S±.0.0002, Accuracy Dissolved Solids Brix: ±.:>0.1% Temperature Resolution: 0.1°C Temperature Range ( Min0.1°C ) : 0.-50°C Correcting Range Of Brix Versustemperature: 15-45°C Usagetemperaturerange: Ambient To 35°C Interface: Rs232 Dimensions ( Mm ) : 370X240x470 Powersupply: Ac220vi50hz Net Weight: 3Kg , Polarimeter , Measuring Range Optical Rotation:±180°Divisionvalue:1° Dial Vernier Value In Reading 0.05° Eyepiece5x Magnifying Glass4x Test Tube Length1oomm And 200Mm Led Light Source Monochromatic Ware Length 589.4Nm Power Source 220V / 50Hz Ledbrightness8000lx Ledworkingcurrent0.35A Ledworkingvoltage2.3V Ledcontinuoususedtime30000hs Instrumentweight4.3Kg , Ph Meter , Range: -2.000 To 20.000 Ph Accuracy ( ±1 Digit ) : ±0.002 Ph Calibration: 22 Pre-Programmed Ph Buffer Sets Automatic Buffer Recognition And Display: Yes Maximum Ph Calibration Points: 5 Manual Calibration With Selectable Buffers: Yes Mv: Range: -2200.0 To 2200.0 Mv Accuracy ( ±1 Digit ) : ±0.1 Mv Autorange Function: No Mv Differential Measurement: Yes Ise Measurement: Range: 1.0E-40 To 9.9E39 Mg / L Display: %, Ppm, Mg / Kg, Mol / L Ise Calibration Points: 2 To 9 Standard Concentrations: 1.00E-30 To 1.00E30 Mg / L Methods: Standard Addition, Double Standard Addition, Standard Subtraction, Sample Addition, Sample Subtraction, Blank Addition, Blank Correction, Reference Measurement Temperature: Range: -31.0 To 302 °F ( -35.0 To 150.0 °C ) Accuracy ( ±1 Digit ) : ±0.2 °F ( ±0.1 °C ) Selectable °F / °C Units: Yes Automatic Switch To Manual Temperature Input When No Temperature Sensor Is Connected: Yes Warranty: 3 Years , Melting Point Apparatus , Display: 4Digitsevensegmentleddisplaya Temperature Ambient To 275°C Resolution: 1°C Capillaryglasstube: 1Oommlong, 0.8To1.1Mminternaldiameter Boiling Point: 6X75mmglasstube Sample Size: Finepowderproperlydried Oil-Bath: Silicon Oil Bathbeaker-200Mlcapacity With Teflon Covertitted Wtth Oil Immersion Heater.Itis Having Three Holes For Holding The Capillaries, One Tor Boiling Point Tube And One Tor Thermometer Stirrerspeedpower: Controllablewithfrontknob Power: 230V±10%Ac, 50Hz Weight: 6Kg. ( Approx. ) Standardaccessories: Boxofcapillaries Glasstubesforliquidsample ( 6X75mm ) 2Nos. Magneticcapsule Bottleofsiliconoil-250Ml Glasscylindricalbeakerwithtefloncoverfitted Withimmersionheaterinstructionmanual, Dustcover
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.