Tender For Addition Alteration To Adm Building Alongwith Office Space And Annex With Allied Em Works At Af Stn Abohar Under Ge(Af) Bhisiana, bhisiana-Punjab

Military Engineer Services-MES has published Tender For Addition Alteration To Adm Building Alongwith Office Space And Annex With Allied Em Works At Af Stn Abohar Under Ge(Af) Bhisiana. Submission Date for this Tender is 23-09-2023. Building Work Tenders in bhisiana Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39417446
Corrigendum : Tender For Addition Alteration To Adm Building Alongwith Office Space And Annex With Allied Em Works At Af Stn Abohar Under Ge(Af) Bhisiana
Open Tender
Indian
Punjab
bhisiana
23-09-2023

Tender Details

Tender For Addition Alteration To Adm Building Alongwith Office Space And Annex With Allied Em Works At Af Stn Abohar Under Ge ( Af ) Bhisiana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 32620.0 /-
Tender Value
INR 16.31 Lakhs /-

BOQ Items

NAME OFWORK : ADDITION/ ALTERATION TO ADM BUILDING ALONGWITH OFFICE SPACE AND ANNEX WITH ALLIED E/M WORKS AT AF STN ABOHAR UNDER GE(AF) BHISIANA
Sl. No. Item Description
1BUILDING WORKS (B/R PORTION)
2Demolition of Brickwork or stone/ boulder masonary ,built in cement mortar or cement lime mortar, complete all as specified and directed by Engineer in Charge.
3Demolition of reinforced cement concrete of any description and in any position (other than ground floor) in beams, staircases, landing chajjas and similar work, complete all as specified and directed by Engineer in Charge.
4Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer in Charge.
5Excavating in trenches, not exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out.in soft/loose soil, complete all as specified and directed by Engineer in Charge.
6M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed by Engineer in Charge.
7M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and directed by Engineer in Charge.
8M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer in Charge.
9M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed by Engineer in Charge.
10M&L Cement concrete type D2, 1:4:8 as in foundations, filling and mass concrete complete all as specified and directed by Engineer in Charge.
11M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) as in Foundations, including rafts,Footings,Foundation, Beams; Plinth Beams; Bases for Columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed by Engineer in Charge.
12M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer in Charge.
13M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) as in chajjas, complete all as specified and directed by Engineer in Charge. NOTE : Reinforcement will be Measured and Paid for separately under appropriate Item.
14M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) as in Beams, cantilevers, bressummers,lintels over 1.5m span, complete all as specified and directed by Engineer in Charge. NOTE : Reinforcement will be Measured and Paid for separately under appropriate Item.
15M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) Columns, pillars, piers, posts and struts etc, complete all as specified and as directed by Engineer in Charge. NOTE : Reinforcement will be Measured and Paid for separately under appropriate Item.
16M&L, 25 mm thick Damp proof course in cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork , complete all as specified and directed by Engineer in Charge.
17M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and directed by Engineer in Charge.
18M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces, complete all as specified and directed by Engineer in Charge.
19M&L forFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), for flat surfaces complete all as specified and directed by Engineer in Charge.
20M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer in Charge.
21M&L for Formwork to sides of pillars, posts, struts, piers,columns and stanchions complete all as specified and directed by Engineer in Charge.
22M&L for Mild steel TMTbars 8 to 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed by Engineer in Charge.
23All as per srl item no 1.021 above but 6 to 8 mm dia, complete all as specified and directed by Engineer in Charge.
24All as per srl item no 1.021 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binderscomplete all as specified and directed by Engineer in Charge.
25Material and labour for brick work built in CM (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed by Engineer in Charge.
26M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built in cement mortar (1:4), complete all as specified and directed by Engineer in Charge.
27Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer in Charge.
28Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed by Engineer in Charge.
29Material and labour for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc.complete all as specified and directed by Engineer in Charge.
30Supply only Integral water proofing compound all as specified and as directed
31Material and labour for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc, complete all as specified and directed by Engineer in Charge.
32Material and labour for rendering 5 mm thick cement plaster 1:3 on fair faces ofconcrete surfaces in ceiling ,finished even and smooth without using extra cement , complete all as specified and directed by Engineer in Charge.
33Material and labour for 50 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protectionfinishing cement concrete surface even and smooth without using extra cement, including making construction joint at a interval not exceeding 2.00 m and at each corner / tornn and filled with sealing compound with grade A(normal)in 25/30 , complete all as specified and directed by Engineer in Charge.
34M&L for applying Two applying two coats of cement base paint over a coat of of same make , inluding preparation of new surfaces , complete all as specified and directed by Engineer in Charge.
35M&L for applying two coats ofoil bound distemperover plastered/ concrete surfaces of any description over 10cm girth or width, not otherwise described over a coat of primer , including preperation of new concrete surfaces, complete all as specified and directed by Engineer in Charge.
36M&L for applying 3mm thick wall care putty on wall , complete all as specified and directed by Engineer in Charge.
37M&L for Preparation of new plastered/concreted surfaces of walls and applying two coats of white wash complete all as specified and directed by Engineer in Charge.
38M&L for Preparation of new plastered/concreted surfaces ofceilingand applying two coats of white wash over ceiling, complete all as specified and directed by Engineer in Charge.
39Material and labourfor Screed bed or bedding layer of cement mortar (1:6), 15 mm thick for laying floor finishes complete all as specified and directed by Engineer in Charge.
40M&L for brick Hardcore of gauge n exc. 63 mm, eposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface , complete all as specified and directed by Engineer in Charge.
41Material and labour 100 mm thick Cement concrete type D-2, 1:4:8(40mm graded aggregate) as in sub base to flooring complete all as specified and directed by Engineer in Charge.
42Material and labour forNon Skid ceramic Coloured tiles , 7 to 8 mm thick , joint free(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer in Charge.
43M&L forvitrified ceramic tiles ,double charged ,( light shade)10 mm thick(square/rectangualr ) area of each tilenot exceeding 0.36 sq, in floors etc . set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed by Engineer in Charge.
44All as per srl item no 1.042 above but as in skirting of 100 mm height and laid over 10 mm thick cement plaster in CM(1:4), complete all as specified and directed by Engineer in Charge.
45M&L for Coloured Glazed ceramic tiles , joint free,on vertical surface 350x250x7 mm/450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles including taking down existing finishes of wall surface, etc. laid over with 10 mm thick cement plaster in CM(1:4 ), complete all as specified and directed by Engineer in Charge.
46Supply and fixed 100 mm bore cast iron soil waste and vent pipes, sand cast pipe, in any length with or without ears, with cement joints, laid in trenches complete all as specified and directed by Engineer in Charge.
47Supply and fixed 100 mm bore cast iron soil waste and vent pipes, sand cast pipe, in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
48Supply and fixed75 mm bore cast iron soil waste and vent pipes, sand cast pipe, in any length with or without ears, with cement joints, laid in trenches complete all as specified and directed by Engineer in Charge.
49Supply and fixed 75mm bore cast iron soil waste and vent pipes ,sand cast pipe, in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
50Supply and fixed cast iron "P" or ;S; trap 100 mm bore, with cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
51Supply and fixedcast iron socket (double collar), 100 mm bore,with cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
52Supply and fixedcast iron socket, 75 mm borewith cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
53Supply and fixedcast Iron 100 mm bore branch piece single,( equal or unequal)singlewith acces door, ordinary or inverted (spigot or socket type) or with parrallel branches, with oval access door,with cement joints, fixed to walls, complete all as specified and directed by Engineer in Charge.
54Supply and fixedcast iron bends, 100mm bore , (any radius),disiminishing pieces or tapper (larger bore measured) with oval acess door, complete all as specified and directed by Engineer in Charge.
55Supply and fixedcast iron bends, 75 mm bore , (any radius),disiminishing pieces or tapper (larger bore measured)with oval acess door, complete all as specified and directed by Engineer in Charge.
56Supply and fixedcast Iron 75 mm bore branch piece single,( equal or unequal)singlewith acces door, ordinary or inverted (spigot or socket type) or with parrallel branches,with oval access doors, complete all as specified and directed by Engineer in Charge.
57Supply and fixedfor 75mm cast iron floor trapwith SS grating 100 to 125 mm dia ,including jointing with solvent cement , joint to waste pipe fixed in cement concrete type B1(1:2:4) , complete all as specified and directed by Engineer in Charge.
58Supply and fixed stack clamp for 75 mm bore pipe out of 50 mm by 5 mm flat iron and 16 round round iron stay.including bolt and nuts and securing ends of stay to walls or roof , complete all as specified and directed by Engineer in Charge.
59supply and fixedstack clamp for 100 mm bore pipe out of 50 mm by 5 mm flat iron and 16 round round iron stay.including bolt and nuts and securing ends of stay to walls or roof , complete all as specified and directed by Engineer in Charge.
60Material and labour for providing precast cement concrete cover slabs using cement concrete Type B1(1:2:4) ,20 mm graded aggregate,(for manholes etc) and simillar works , complete all as specified and directed by Engineer in Charge.
61Material and labour 15 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge.
62Material and labour 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge.
63Cutting chases, pining in making good to facing where required and pointing incement mortar 1:3 for concealed water tubing , cutting not exc 10 cm girth , complete all as specified and directed by Engineer in Charge.
64Material and labour, for three layered white colour Rotational moulded polyethylene water storage tanks of 500 ltrCapacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part complete all as specified and directed by Engineer in Charge.
65Material and labour, 20mm Ballvalves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer in Charge.
66Material and labour for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union 20mm dia of pipe,complete all as specified and directed by Engineer in Charge.
67M&L Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union of 15 mm dia of pipe, complete all as specified and directed by Engineer in Charge.
68S&F Vitreous China wash down water closet pan (pedestal pattern), white, with PVC seat cover, complete all as specified and directed by Engineer in Charge.
69Material and labour PVC valveless , syphonic action type , flushing cistern, low level ,white, with inlet, ball valve, float and handle, flush pipe of polythelene of low or high density or PVC 32 mm dia , including brackets / fastening assesoriesof 10 litres capacity , complete all as specified and directed by Engineer in Charge.
70S&F Vitreous China Urinal, Half stall type, white , including 32 mm weste coupling and PVC waste pipe of length not exceeding 900mm, complete all as specified and directed by Engineer in Charge.
71S&F urinal spreader PTMT of 15 mm size, complete all as specified and directed by Engineer in Charge.
72S&F for mirror cabinet ofmin size 430x330 mm with openable door shutter (as approved by GE) , complete all as specified and directed by Engineer in Charge.
73Material and labour Vitreous China wash basin, white , flat back,size 550x400mm fixed onbrackets or stands, including 32 mm waste coupling of PTMT (half or full threaded)/ CP Brass and corrugated waste pipewith adopter of 900 mm long, fixed in repair, complete all as specified and directed by Engineer in Charge.
74Supply and Fixed wash hand basinBrass CP mixture for mixing hot and cold water screwed down for 15 mm iron pipe and fixed , complete all as specified and directed by Engineer in Charge.
75Supply and Fixed 15 mm dia bore angular stop cock with wall flange cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union completeall as specified and as directed by Engineer-in-charge.
76Supply and Fixed15 mm dia bore concealed stop cockcast copper alloy chromium plated with long sahnk , fancy type,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union completeall as specified and as directed by Engineer-in-charge.
77Supply and Fixed PVC connections 15 mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer in Charge.
78Supply and Fixed, 15 mm diaBib taps ,fancy type Chromium plated, screwed down , screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer in Charge.
79Supply and Fixed brass CP Wall mixer, 15 mm bore, for mixing hot and cold water , screwed down for iron pipe and fixed .complete all as specified and directed by Engineer in Charge.
80Supply and Fixed , Brass Chromium plated shower rose 125 mm size with or without swivel joints,including fixing to steel pipe or union , complete all as specified and directed by Engineer in Charge.
81S&F stainless steel soap dish including all necessary stainless steel screws, complete all as specified and directed by Engineer in Charge.
82S&F Corner Glass Shelfsingle Decker (Triangular shape) of size 30 CM, complete all as specified and as directed by Engineer in Charge.
83Supply and FixedBrass CP tubular towel rail of 20 mm dia, D type ,60 CM long between flange , complete all as specified and as directed by Engineer in Charge.
84S&F PTMT 125 mm size( Dia /square) Gratings with hole complete all as specified and as directed by Engineer in Charge.
85S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs,hinges, lock strike plate, etc complete all as specified and directedof size 105 X 60mm, complete all as specified and as directed by Engineer in Charge.
86M&L for PCC (1:3:6) type C-1 using 20 mm graded agg as in filling in back of pressed steel chowkhatsetc complete all as specified and directed.
87Supply and fixing, Factory made, 35mm thick plain framed panelled shutters (two panel) with lock rail and panelof 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces using 2nd class HW as in rail and style. The size of rail and style as per IS-1003 (part – I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
88S&F 150mm Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer in Charge.
89S&F 300 mm aluminium ally, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed , complete all as specified and directed by Engineer in Charge.
90S&F 150 mm extruded Aluminium alloy handles, fabricated typeanodised, complete all as specified and directed by Engineer in Charge.
91M&L applying Two coats of Synthetic enamel paint over a coat of pink primer including prepration of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified and directed by Engineer in Charge.
92Material and labour for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and as directed by Engineer in Charge.
93S&F 140 mm size ,Floor door stopper of brass alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer in Charge.
94S&F Door Closer Aluminium (Die Cast) Body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram, complete all as specified and as directed.
95S&F Anodised aluminium frame powder coated, for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer in Charge.
96S&F Anodised aluminium door shutters powder coated (Thickness or powder coating not less than 50 micron),aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws incl taking down etc. complete all as specified and directed by Engineer in Charge.
97S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer in Charge.
98S&F 150 mm sizeAluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer in Charge.
99S&FMS powder coated Curtain Rods with fixing MS powder coated brackets,including screws , rawal plug etc, complete all as specified and directed by Engineer in Charge.
100Supply and fixing in repairPVC powder coated fineals /fency end bulbbs , fixed at ends of curtain rods, complete all as specified and directed by Engineer in Charge.
101S&F Mild Steel Mortice Lock 100mm in size, 4-Lever, Vertical type, complete all as specified and as directed.
102S&F Sheet Glass4.8mmthick, Ordinary quality and glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed.
103S&f Anodised aluminium snap grid frame work ,Size of grid 605 x 605mm, for false ceiling all as specified complete all as specified and as directed by Engineer in Charge.
104S&fHangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed by Engineer in Charge.
105S&f 12 mm thick ,Perforated particle board/tiles for insula-tion and accoustic purposes,60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid, complete all as specified and as directed by Engineer in Charge.
106Supply and fixed cast iron "P" or ;S; trap 100 mm bore with cement joint, complete all as specified and as directed by Engineer in Charge.
107M&L forCement Screed bed or bedding layer of mortar 10 mm thickin cement mortar (1:4) for laying floor finishes over roof , complete all as specified and as directed by Engineer in Charge.
108Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces, complete all as specified and as directed by Engineer in Charge.
109M&L for APP based Polymeric Membrane minimum weighing 3.0 KILOGRAM PER SQUARE METRE and minimum 3.0mm thick reinforced with Polyster Non-wove Fabric (weight not less than 150 GRAM PER SQUARE METRE) laid on primed surface by Torch application method, complete all as specified and as directed by Engineer in Charge.
110S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints fixed to Walls, floor, complete all as specified and as directed by Engineer in Charge.
111S&F PVC (SWR) 110mm bore (dia), Bend any type, provided with Access Door, etc. and jointing with Solvent Cement, complete all as specified and as directed by Engineer in Charge.
112EXTERNAL SERVICES (ROAD/PATH/CULVERTS)
113Surface excavation n. exc. 30 cm deeep and averaging 15 cm in any type of soil getting out complete all as specified and as directed by Engineer in Charge.
114M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and as directed by Engineer in Charge.
115M&L 75mm thick PCC 1:4:8 type D2 using 40mm graded stone as in sub base, complete all as specified and as directed by Engineer in Charge.
116Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for laying of Sewage line, manholes etc and getting out in any type of soil, etc complete all as specified and as directed by Engineer in Charge.
117Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick etc complete all as specified and as directed by Engineer in Charge.
118Removing excavated material (soils) to a distance not exc 50m and depositing where directed etc complete all as specified and as directed by Engineer in Charge.
119M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness with gray cement & pigment, M-35 Grade, complete all as specified and as directed by Engineer in Charge..
120M&L for 25 mm thick sand filling under floor including watering and consolidation complete all as specified and as directed by Engineer in Charge.
121M&L for brick work with Sub class "B" bricks straight or curved on plan exceeding 6m mean radiusbuilt in CM (1:4) etc complete all as specified and as directed by Engineer in Charge.
122M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed by Engr-in-Charge.
123M&L for providing cement concrete type B1 (1:2:4), 20 mm aggregate as in copings, complete all as directed by Engineer-in-charge.
124EXTERNAL SERVICES (SEWAGE DISPOSAL)
125Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for laying of Sewage line, manholes etc and getting out in any type of soil, etc complete all as specified and as directed by Engineer in Charge.
126Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick etc complete all as specified and as directed by Engineer in Charge.
127Removing excavated material (soils) to a distance not exc 50m and depositing where directed etc complete all as specified and as directed by Engineer in Charge.
128Cutting into existing manholes for connecting new drains 150mm bore pipe including removing existing branch drain pipes of 150/200mm bore & benching to form branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming benching as required and making good surface with plaster etc to match existing , etc complete all as specified and as directed by Engineer in Charge.
129M&L for 150 mm Salt glazed stoneware drain pipes laid in trenches and jointed complete all as specified and as directed by Engineer in Charge.
130M&L for providing cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) 100mm thick bed for 150mm bore pipes including packing under and haunching against the sides of pipes after they are laid tested, etc complete all as specified and as directed by Engineer in Charge.
131M&L for brick work with Sub class "B" bricks straight or curved on plan exceeding 6m mean radiusbuilt in CM (1:4) etc complete all as specified and as directed by Engineer in Charge.
132M&L for cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in foundation, fillings & mass concrete, manhole sub base etc complete all as specified and as directed by Engineer in Charge.
133Cement concrete (1:3:6) type C-2 (using 20mm graded crushed stone aggregate) as in surface channels & drains, etc complete all as specified and as directed by Engineer in Charge.
134M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and fair complete all as specified and as directed by Engr-in-Charge.
135M&L for precast cement concrete Type B1 (1:2:4) using 20 mm graded stone aggregate as in cover slabs for manholes etc, set in CM 1:4 complete all as specified and as directed by Engineer in Charge.
136S&F TMT MS bar 6 to 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia of Gd.I, IS- Fe-410-W 432 (Part I) (Gde.E-250) Part- I as specified,complete all as specified and as directed by Engineer in Charge.
137SITE CLEARENCE AND DEVELOPMENT
138Surface excavation n.exc 30cm deepand averaging 15 cm deep and getting out in soft/loose soil , complete all as specified and as directed by Engineer in Charge.
139Removal of excavated material to a distance not exc 50m and deposited where directed at a level not exc 1.5m as directed, complete all as specified and as directed by Engineer in Charge.
140INTERNAL SERVICES (E/M WORKS)
141Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
142S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
143M&L for concealedPoint Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19/ 20 mm in size, medium grade, and its Accessories in Concealed (Partly)with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, suitable for modular mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY MODULAR SWITCH 6 AM, complete all as specified and as directed by Engineer in Charge.
144All as per Item No 5.03 for One 3 Pin modular swich socket Combination 6 amp on the same board, complete all as specified and as directed by Engineer in Charge.
145All as per Item No 5.03 for One 3 Pin modular swich socket Combination 6 amp on independentboard, complete all as specified and as directed by Engineer in Charge.
146All as per Item No 5.03 above but with 2.5 Sqmm Cable size with 2.5 sqmm earth continuity wire forOne 3 Pin modular socket Combination 16 amp on independentboard.
147Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer in charge.
148S&F LED light fitting 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer in charge.
149Supply and fixing LED Street lights fitting 35, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer in Charge.
150S&F Modular Fan Regulator in 4 Step type 2M suitable for ceiling fan 1200 mm sweep, 240 Volt, Electronic type 100 W, complete all as specified and as directed by Engineer in Charge.
151S&F Call Bell Electric (Musical) 230 Volt, AC supply, complete all as specified and as directed by Engineer in Charge.
152S&FBell Push Button 6 Amp Modular type 1M, Flush type suitable for Call Bell, complete all as specified and as directed by Engineer in Charge.
153S&F Modular Switch 1 way 6 Amp, 1 module, 230 Volts, complete all as specified and as directed by Engineer in Charge.
154S&F Modular Socket Outlet 6 &16 Amp 2/3 pin combined 2 module, complete all as specified and as directed by Engineer in Charge.
155S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and Fixing-in-repairs, complete all as specified and as directed by Engineer in Charge.
156S&F Modular Socket Outlet 16 Amp 3 pin combined 2 module, complete all as specified and as directed by Engineer in Charge.
157S&F Modular Switch 16 Amp 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
158S&F Sheet Metal Enclosure, for DB"s for incorporating MCBs, TPN 4-way, IP-43 double glazed dooe with 200 amps rated bus bar 415 voltsas per IS-8623 TPN DB, complete all as specified and as directed by Engineer in Charge.
159S&F MCB 4P, 63 Amp, 240 Volt, AC, "C" Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up and Fixing-in-repairs, complete all as specified and as directed by Engineer in Charge.
160S&F MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, "C" Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up, complete all as specified and as directed.
161M&L Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed by Engineer in Charge.
162Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV etc complete all as specified and directed by Engineer in Charge.
163S&F PVC Connection Pipe 15mm size and 45 Cm in length with Adopter Nuts of PVC, complete all as specified and as directed by Engineer in Charge.
164S&F Connection Pipe 15mm size spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection and 45 Cm in length with Adopter Nuts of PVC , complete all as specified and as directed by Engineer in Charge.
165S&F Angle Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, screwed down, high pressure, screwed both Ends for Iron Pipe, complete all as specified and as directed by Engineer in Charge.
166Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value BEE Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer in Charge
167Supply and fix exhaust fan made of Steel body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m including provision of three Core 1.5 Sq.mm Copper cable of suitable size connected from ceiling rose and making good the disturbed surface, complete all as specified and directed by Engineer in Charge
168M&L for GI Pipe Bracket made out of Galvanised Iron Tubing 32mm bore (dia), light grade, 1.50 METRE long bent to shape with two Nos of MS Clamp duly painted nuts and bolts as per specified for fixing Street Light Fittingincluding taking down unserviceable GI Pipe Bracket, complete all as specified and as directed.
169Supply, Installation , testing and commissioning of LT Electric control panel cubical type of suitable size for 3 Phase 415 Volts outdoor type floor mounted made out 3 mm thick and inner sheet 2mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire use withangle iron 40x40x5 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate of height 45 cm from ground level, with locking arrangement, painting with two coats of synthetic enable paint over a cost of red oxide primer connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items :- (a)MCCB 4 pole 100 Amps 25 KA Magbetic Thermal Realease-02 No (b)Ampere meter (digital type) 0-250 Amps CT Operated with selector switch - 01 No (c) Volt meter (Digital type) 0-500 Volts with selector switch - 01 No
170Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying ofCable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed by Engineer in Charge.
171Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed by Engineer in Charge.
172Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed by Engineer in Charge.
173M&L Sand (Fazilka) Cushioning (dry) in trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (15 Cm in depth before laying the Cable and 8 Cm in depth after laying the Cable) and consolidated (punned) upto 18 Cm thickness, complete all as specified and as directed by Engineer in Charge. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
174Supply and laying reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x150 mm x 40 mm complete all as specified and as directed by Engineer in Charge.
175Taking out existing unserviceable single phase electric energy meter and S&F 3 phase 4 wire AC Static Energy meter of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like Display in absence of Power with Transparent Hinge type Box all as specified and directed by Engr-in-Charge.
Disclaimer :