Tender For Supply Of Dry Ration Items At 30Th Bn Itbp ,Jalandhar, delhi-Delhi

Department Of Electronics And Information Technology has published Tender For Supply Of Dry Ration Items At 30Th Bn Itbp ,Jalandhar. Submission Date for this Tender is 20-09-2023. Reverse Osmosis Plant Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

39410036
Tender For Supply Of Dry Ration Items At 30Th Bn Itbp ,Jalandhar
Open Tender
Indian
Delhi
delhi
20-09-2023

Tender Details

Tender For Supply Of Dry Ration Items At 30Th Bn Itbp , Jalandhar; 1 Supplying, Installation, Testing & Commisioning Of 2 X 2000 Lph Ro Plant Along With Recycling Of Drain Water At Electronics Niketan New Delhi 2 Supplying, Installation, Testing & Commissioning Of Reverse Osmosis System With Capacity Of 2000 Lph Designed For Treatment Of Saline Water In The Tds Range Of 1500-2000Ppm Which Are Completely Assembled / Pre-Piped / Pre-Wired With Microprocessor-Based Control Panel For Ease Of Operation And Inbuilt Process Logic Having Provision For Auto Start / Stop Based On Water Level In The Tank With Mcb For Plant Operation And Raw Water Pump Integrated With Plant. Integrated Pretreatment Module For Removal Of Suspended Solids Along With Pressure Gauges, Robust High Pressure Pump In Ss 304 Construction, Inbuilt Protection To High Pressure Pump By Way Of Low Pressure Switch / High Pressure Switch And Glycerin Filled Ss Pressure Gauges For Durability, On Line Rota Meter For Measuring Permeate Flow And Powder Coated Ms Skid With Plated Hardware. Ro Plant Is Having Psf, Acf, Antiscalant Dosing System, Micron Cartridge Filter, High Pressure Pump, Ro Membrane Of 4*40 Having Backwash Facility. The Product Is Iso & Ima Certified , Gc ( Green Company ) Mark And Bis Certificate, Iso 14001, Iso17025, Iso9001. Make: Ion Exchange / Thermax / Eureka Forbes Or Equivalent 3 Centering And Shuttering With 12Mm Thick Shuttering Plywood Confirming To Is 4990:2011 And Removal Of Form At All Heights. Plywood Will Be Supported On Lock Bars Suspended Floors, Roofs, Landings, Balconies And Access Platform. 4 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, B120 Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources 5 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Naturalsources : 6 Graded Stone Aggregate 20 Mm Nominal Sizederived From Natural Sources ) 6 Brick Work With Common Burnt Clay Machine Moulded Perforated Bricks Of Class Designation 12.5 Conforming To Is: 2222 In Superstructure Above Plinth Level Up To Floor Five Level In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) : With F.P.S. ( Non Modular ) Bricks 7 Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( + 0.05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55 Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 8 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 9 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge A ) 25 Mm 10 B ) 32 Mm 11 C ) 40 Mm 12 Supplying And Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Directly On Surface Etc. As Required Upto 35 Sq. Mm 13 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. ( 28 Mm ) 14 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earthbar, Din Bar, Interconnections, Powder Painted Includingearthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way, Double Door 15 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 4 Way ( 4 + 12 ) , Double Door 16 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 17 Single Pole And Neutral 18 Sitc Of Isi Marked Self Contained Stainless Steel Drinking Water Cooler With Reciprocating Compressor ( R-22 Refrigerant ) , Cooling Capacity Litres / Hour : 150 Type : Storage, Storage Capacity Litres : 150 Faucets - 2 Nos., Material - Stainless Steel, Grade Ss 304.Specially Designed Float Valves Made Of Food Grade Plastic - 1 No. Including Inlet Water Connection With Suitable Length Pipe Etc As Required At Site. 19 Fabrication, Supplying And Fixing Of Mild Steel Structure Frame Work Fabricated Out Of 40 Mmx40mm X5mm Angle Iron, Tee Section Of 40Mmx40mmx5mm ( Nominal Size ) By Making Block Of 90 Cmx90cm In Frame I / C Providing And Fixing Wiremesh Of Section 75Mmx25mm Rectangular Having Weight Not Less Then 7.75 Kg / Sqmtr And Shall Be Fixed And Shall Be Fixed And Supporting And Welded With 20Mmx3mm Ms Flat ( Nomial Size ) And 60Cm Long 40X40x5mm ( N / S ) Angle Iron Welded To The Frame Is To Be Grouted In Cement Concrete 1:3:6 Foundation Of Size 20X20x40cm Painted With Two More Coats Of Red Oxide Primer And Two Coats Of Synthetic Enamel Paint And Providing Door With Locking Arrangement Complete Etc. As Required. 20 Operation Of Ro System Of Capacity 2 X 2000 Lph By Trained Operator On Monthly Basis In General Shift On All Working Days Excluding Sunday & Holidays As Requiredoperator - 1 No. In General Shift 21 Providing And Fixing Of R.O. Membrane Cpa2-8040 For The 1000 Lph R.O. Plant Installed. 22 Supplying And Charging Of Following Consumables Material Of Superior Quality Of Water Treatment Chemicals To Ro System.A ) Anti-Scalent Chemical Make Vem Chemical / Nalco / Ion Exchange. 23 Supply And Dozing Of Membrane Cleaning Chemical In Existion Ro Plant Etc. As Reqd. Make Vem Chemical / Nalco / Ion Exchange. 24 Supply And Dozing Of Bacteriological Disinfection Chemical In Pure Water Tank Of Ro Plant Etc. As Reqd.Make Hydranautics / Film Tech ( Dow ) / Csm / Torray.

Key Value

Document Fees
Refer document
EMD
INR 107302.0 /-
Tender Value
INR 53.65 Lakhs /-

BOQ Items

Name of Work: Supplying, Installation, Testing & Commisioning of 2 x 2000 LPH RO Plant along with recycling of drain water at Electronics Niketan New Delhi
Sl. No. Item Description
1Supplying, Installation, Testing & Commisioning of 2 x 2000 LPH RO Plant along with recycling of drain water at Electronics Niketan New Delhi
2Supplying, Installation, Testing & Commissioning of Reverse Osmosis System with capacity of 2000 LPH designed for Treatment of saline water in the TDS range of 1500-2000ppm which are Completely assembled /Pre-piped/Pre-wired with Microprocessor-based control Panel for ease of operation and inbuilt process Logic having provision for Auto start/stop based on Water level in the Tank with MCB for Plant operation and Raw water pump integrated with Plant. Integrated pretreatment Module for removal of suspended solids along with pressure gauges, Robust high Pressure Pump in SS 304 Construction, Inbuilt Protection to high Pressure Pump by Way of Low Pressure Switch/high Pressure switch and Glycerin filled SS Pressure gauges for durability, On line Rota meter for measuring permeate flow and Powder coated MS skid with plated hardware. RO plant is having PSF, ACF, Antiscalant Dosing System, Micron cartridge filter, High pressure pump, RO membrane of 4"*40" having backwash facility. The Product is ISO & IMA Certified ,GC (Green Company) Mark and BIS certificate,ISO 14001, ISO17025, ISO9001. Make: ION Exchange/Thermax/Eureka Forbes or equivalent
3Centering and shuttering with 12mm thick shuttering plywood confirming to IS 4990:2011 and removal of form at all heights. Plywood will be supported on lock bars Suspended floors, roofs, landings, balconies and access platform.
4Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,B120 abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources
51:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
6Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks
7Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
8Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
9Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge a) 25 mm
10b) 32 mm
11c) 40 mm
12Supplying and Laying of one number PVC insulated and PVC sheathed armoured XLPE power cable of 1.1 KV grade of following size directly on surface etc. as required Upto 35 sq. mm
13Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq.(28 mm)
14Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
15Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4 + 12), Double door
16Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
17Single pole and neutral
18SITC of ISI marked Self Contained Stainless Steel Drinking Water Cooler with reciprocating compressor (R-22 Refrigerant), cooling capacity litres/hour : 150 Type : Storage, Storage capacity Litres : 150 Faucets - 2 Nos., Material - Stainless Steel, grade ss 304.Specially designed float valves made of food grade plastic - 1 No. including inlet water connection with suitable length pipe etc as required at site.
19Fabrication, Supplying and fixing of mild steel structure frame work fabricated out of 40 mmx40mm x5mm Angle iron, Tee section of 40mmx40mmx5mm(nominal size) by making block of 90 cmx90cm in frame i/c providing and fixing wiremesh of section 75mmx25mm rectangular having weight not less then 7.75 kg/sqmtr and shall be fixed and shall be fixed and supporting and welded with 20mmx3mm MS flat (nomial size) and 60cm long 40x40x5mm(N/S) angle iron welded to the frame is to be grouted in cement concrete 1:3:6 foundation of size 20x20x40cm painted with two more coats of red oxide primer and two coats of synthetic enamel paint and providing door with locking arrangement complete etc. as required.
20Operation of RO system of capacity 2 x 2000 LPH by trained operator on monthly basis in General shift on all working days excluding Sunday & Holidays as requiredOperator - 1 No. in General shift
21Providing and fixing of R.O. membrane CPA2-8040 for the 1000 LPH R.O. plant installed.
22Supplying and charging of following consumables material of Superior Quality of Water Treatment Chemicals to RO system. a) Anti-Scalent Chemical make Vem Chemical/Nalco/Ion Exchange.
23Supply and dozing of Membrane cleaning chemical in existion RO plant etc. as reqd. make Vem Chemical/Nalco/Ion Exchange.
24Supply and dozing of Bacteriological disinfection chemical in pure water tank of RO plant etc. as reqd.make hydranautics/Film tech(DOW)/CSM/ Torray.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail