Department Of Electricity-DOE has published Tender For Work Of Conversion Of 11Kv Overhead Line Of Advalpal And Salem Village Into Underground Cable System In The Jurisdiction Of Sub Division-I(U), Bicholim, Division-V, Bicholim. Submission Date for this Tender is 21-09-2023. Overhead Line Tenders in bicholim Goa. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Cost of Material |
2 | 11KV Cable Work |
3 | Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable |
4 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand for cushioning of HT underground cables. ( 1R : 6400 x 0.2 x 0.4) ( 2R : 1800 x 0.2 x 0.6 ) |
5 | Supply of f RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910 |
6 | Supply ofGI Pipe 150mm, class B for road crossing/bridge & cable riser |
7 | Supply ofRCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed) |
8 | Supply of Bricks class design 75 kg/cm2 (1st class wire cut) |
9 | Supply of 11 KV Straight Through joint 3 core 300sqmmXLPE |
10 | Supply of11 KV Termination kit Indoor 3 core 300sqmmXLPE |
11 | Supply of 11 KV Termination kit outdoor 3 core 300sqmmXLPE |
12 | Supply ofRCC Cable route marker (400 x 900 x 100mm) |
13 | Supply & Erection of Warning tape. |
14 | Ring Main Unit |
15 | Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
16 | Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS : Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
17 | Supply of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB : a. Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU. |
18 | Civil Work for Ring Main Unit |
19 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil |
20 | Providing and laying in position cement concrete 1:2:4(1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. Dimensions for RMU for 2LBS+1CB & 3LBS = ((2.8*3/4)*.551*1.5)*2 |
21 | Centering and shuttering including struttings, propping etc and removal of formwork . Dimensions for RMU for 2LBS+1CB & 3LBS= (((2.8*3/4)*1.5*2)+(1.5*0.551*2))*2 |
22 | 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimensions for RMU for 2LBS+1CB & LBS = (((2.8*3/4)*0.551)+(2.8*3/4)*0.5*2)+(0.5*0.551*2))*2 |
23 | 11KV Cable for RMU & Jointing Kits |
24 | Supply of11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite. |
25 | Supply of11 KV Termination kit Indoor3 core 95sqmmXLPE |
26 | Supply of11 KV Termination kit Outdoor3 core 95sqmmXLPE |
27 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand for cushioning of HT underground cables. |
28 | Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed) |
29 | Supply ofEarthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete. |
30 | Supply ofHDGI flat of size 25mm x 6mm for earthing. |
31 | Supply ofHDGI Structural Material (Such as cable supports,clamps, N&B Etc) |
32 | Cost of Erection |
33 | 11KV Cable Work |
34 | Laying, Testing & commissioningof 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable in open trench method |
35 | Laying, Testing & commissioningof HT/LT UG cables by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable in Normal/hard soil including soft, watery and sandy soil with minimum 8" bore size, including Supply & Laying of HDPE pipe |
36 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil b) All types of Ordinary rock including all types of laterite rock, blasting prohibited ( 1R : 6400 x 1.1 x 0.4) ( 2R : 1800 x 1.1 x 0.6 ) |
37 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge ( 1R : 6400 x 0.9 x 0.4) ( 2R : 1800 x 0.9 x 0.6 ) |
38 | Laying of RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910 |
39 | Laying of GI Pipe 150mm, class B for road crossing/bridge & cable riser |
40 | Erection of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed) |
41 | Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 300sqmmXLPE |
42 | Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300sqmmXLPE |
43 | Erection, Testing & Commissioning of of 11 KV Termination kit outdoor 3 core 300sqmmXLPE |
44 | Erection of RCC Cable route marker (400 x 900 x 100mm) |
45 | Ring Main Unit |
46 | Erection, Testing & Commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
47 | Erection, Testing & Commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS : Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
48 | Erection, Testing & Commissioning of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB : a. Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU. |
49 | 11KV Cable for RMU & Jointing Kits |
50 | Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite. |
51 | Erection, Testing & Commissioning of of 11 KV Termination kit Indoor3 core 95sqmmXLPE |
52 | Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor3 core 95sqmmXLPE |
53 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil b) All types of Ordinary rock including all types of laterite rock, blasting prohibited |
54 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge |
55 | Erection of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed) |
56 | Erection, Testing & Commissioning of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete. |
57 | Erection of HDGI flat of size 25mm x 6mm for earthing. |
58 | Erection of HDGI Structural Material (Such as cable supports,clamps, N&B Etc) |