Sadalpur ( R / W P / Stn. ) Deta... Sadalpur Raw Water Pumping Station Detailed Project Report For Augmentation Of Water Supply Scheme Of Village Sadalpur District Hisar, Hisar-Haryana

Public Health Engineering Department-PHED has published Sadalpur ( R / W P / Stn. ) Deta... Sadalpur Raw Water Pumping Station Detailed Project Report For Augmentation Of Water Supply Scheme Of Village Sadalpur District Hisar. Submission Date for this Tender is 18-09-2023. Detail Project Report Tenders in Hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

39370552
Sadalpur ( R / W P / Stn. ) Deta... Sadalpur Raw Water Pumping Station Detailed Project Report For Augmentation Of Water Supply Scheme Of Village Sadalpur District Hisar
Open Tender
Indian
Haryana
Hisar
18-09-2023

Tender Details

Sadalpur ( R / W P / Stn. ) Deta... Sadalpur Raw Water Pumping Station Detailed Project Report For Augmentation Of Water Supply Scheme Of Village Sadalpur District Hisar

Key Value

Document Fees
INR 15000 /-
EMD
INR 213680.0 /-
Tender Value
INR 1.06 Crore /-

BOQ Items

Name of Work
Sl. No. Item Description
1Supply erection testing and commissioning of Flow Meter(KRONE Make) with digital display of 150 mm i/d complete in all respect.
2`RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having headas per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked 6000 LPM X 40 M X 90 HP
3H.T. METERING PANEL: Supply, erection, testing and commissioning of 11KV Indoor H.T Metering Panel complete with suitable CTs, PTs and 3 phase, 4 wire Digital Electronic KWH Meter with accuracy class of 0.5 as per requirement and approval of DHBVN, consisting of the Cubical Panel Box of minimum size 700mm x700mm x1500mm free standing, floor mounting type made out of 14 SWG CRCA sheet steel powder coated with epoxy coated channel iron base frame Supply erection testing of standard make XLPE 3 core galvanized steel trip armoredHT / 11 KV grade ISI marked cable with aluminum Conductor in ground covered with sand and brick in trenchs in pipes for making following connectiona) from DHBVN G.O switch to metering equipment . b) from metering equipment to transformer c) transformer to LT panel complete in all respect . CAMPUS LIGHT: Supply erection testing of 2 No. reputed make LED light 100 wats with fittings, cable and accessories complete in all repects.
4HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connectiona) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd 35 Sqmm size
5PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electricalLT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following itemsfor 1Pumping set a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No(LandT Siemens, ABB) f) VSS 1 No.and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp= One Set i) Change over switch of suitable Amp = 1 No. (Each) Panel Board for motors having capacity of 90 BHP
6LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 240 Sqmm size
7COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 50 mm2 3core
8Operation and Maintenance of Raw water arrangement for complete scope of work mentioned in the DNIT in the village Disinfection material supplied by the PHED as per schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/mtc estimate). complete in all respects as per approved NIT. 2) Operation and maintenance during defect liability period after 3 month trial run period ( operation only)
91st year Operation and maintenance after defect liability period
102nd year Operation and maintenance after defect liability period
113rd year Operation and maintenance after defect liability period
124th year Operation and maintenance after defect liability period
135th year Operation and maintenance after defect liability period