Power Development Department has published Tender For Creation Of 33/11 Kv, 1X10 Mva Receiving Station Alongwith 33 Kv Line At Kaink Jagir In Respect Of Sub-Transmission Division-I, Jpdcl, Jammu For The Year2023-24. Submission Date for this Tender is 18-09-2023. Road Repair Tenders in jagir Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Sep-2023 | Corrigendum | Other | 18-09-2023 |
2 | 14-Sep-2023 | 2nd Corrigendum | Other | 18-09-2023 |
Sl. No. | Item Description |
1 | 11 Mtr. Long ST Pole |
2 | 9 Mtr. Long ST Pole |
3 | GI V cross-arm with top Bracket including clamp |
4 | GI Channel X-arm including clamps and braces |
5 | 100 mm² ACSR Conductor |
6 | PG Clamps for 100 mm² ACSR Conductor |
7 | 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
8 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
9 | Danger Plates with Clamps |
10 | Anti-Climbing Device with Clamps |
11 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
12 | Red Oxide |
13 | Aluminum Paint |
14 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum /pole |
15 | Aluminum Jointing Sleeves |
16 | 33KV Isolator with Earthing Blade (36KV,1250A, outdoor, 3 poles, 25 KA) |
17 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete |
18 | Guard netting |
19 | 33 KV VCB (36 Kv,1250A, 26.2 KA,Outdoor Type) |
20 | 33KV C&R Panel along with O/C,E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation windows with annunciation relays, 3- Phase Tri Vector meter 5 Amps with RS-485 port DLMS Compliant with RS-485 port |
21 | 33KV Isolator with Earthing Blade (36KV,1250A, outdoor, 3 poles, 25 KA) |
22 | 33KV Isolator without Earthing Blade (36KV,1250A, outdoor, 3 poles, 25 KA) |
23 | 33KV Current Transformer (33KV, 1Ø, Multi Ratio-Multi Core , Outdoor)(1 No. per Ø) of ratio 600/300/5 Amp |
24 | 33KV Voltage Transformer (33KV/110V,1Ø, Multi -Core , Outdoor)(1 No. per Ø) |
25 | 30KV Lightening Arrestors (30KV, 10KA, Station class ZNO, Polymer) gap less |
26 | Galvanised steel Structures |
27 | Galvanised Nuts & Bolts |
28 | 12 CORE 2.5MM2 CONTROL CABLE COPPER Armoured, 1.1 KV Grade ,ISI,FRLS |
29 | 4 CORE 2.5MM2 CONTROL CABLE COPPER Armoured ,1.1 KV Grade ,ISI,FRLS |
30 | 2 CORE 2.5MM2 CONTROL CABLE COPPER Armoured ,1.1 KV Grade ,ISI,FRLS |
31 | Lugs, ferrules etc |
32 | ACSR Conductor Panther |
33 | T Clamps |
34 | Single Tension Fittings |
35 | Earth wire 7/4.00 mmsq. |
36 | GI flat for earthing 50x6 mm for all equipments & gantries |
37 | 33 KV C& R Panel along with O/C,E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3 phase Trivector meter 5 AMPs,DLMS Compliant with RS 485 port |
38 | 33KV Post insulator Polymer 36KV, 235KV Impulse ,creepage distance 1224m |
39 | 33/11 KV, 10 MVA, ONAN, Copper wound, Out door Type conventional power transformer ,Oil filled with OLTC and all accessories including HT and LT terminal Connections |
40 | 6 Core 2.5 mm2 Control cable copper Armoured 1.1 KV grade, ISI, FRLS |
41 | 11KV VCB Panel Board (12KV, 1250A, 25KA, Outdoor) with O/C, E/F relays (IEC61850), Mimic diagram, Voltmeter, Ammeter, Annunciation relays, 3-phase Tri vector meter-5 Amps, DLMS Compliant with RS-485 port for 1x10 MVA (1+5) SCADA Compatible |
42 | 11KV Gapless surge Arrestor,9KV,10KA,LA with Polymer housing Stn. Type |
43 | 11KV, 630mm2, Single core XLPE cable ( with one spare length) armoured, FRLS |
44 | 11KV, 3-Core, 240mm2 XLPE Cablearmoured, FRLS |
45 | 11KV Indoor Heat Shrinkable Cable Termination Kits for incoming cable, 630mm2 Single Core |
46 | 11 KV OutdoorHeat Shrinkable Cable Termination Kits for incoming cable 630mm2 Single Core |
47 | 11KV Indoor Heat Shrinkable Cable Termination Kits for outgoing cable 240 mm2 Single Core |
48 | 11 KV OutdoorHeat Shrinkable Cable Termination Kits for outgoing cable 240 mm2 Single Core |
49 | 11KV Isolator, double break, 3- Pole, 600Amp, Horizontal mounting Type, with earth Switch |
50 | Galvanised iron of sorts |
51 | 100 KVA, 11/0.43KV, 3 Phase distribution Transformers with Bimetallic Terminal connectors Energy level-2 (Aluminum wound) |
52 | 120mm2 PVC LT Cable 3.5 Core, armoured,FRLS |
53 | Earthing of 100KVA Substation(chemical earthing) |
54 | Earthingcomplete by GI Pipe 40 mm |
55 | MCCB -200Amps with enclosure |
56 | 12 kV Capacitor Bank (3.6 MVAR) with VCB Panel with complete arrangement for connection with 11KV incomer Panel, Series Reactor Isolator, RRVT, Surge Arrestors HT Cable with termination kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories |
57 | Compound walling of identified land by way of mass Concrete in Foundations and 228mm Brick Wall of 2 M height including excavation and disposal of unwanted soil alongwith 5 Mtr long, 2 Mtr height gate and 2 Nos. RCC Pillars fitted with light complete in all respect |
58 | Chain link fencing of 33KV yard of Substation by way of Mass Concrete of 33KV yard of Sub station by way of Mass Concrete in Foundations and chain link fencing of 6 ft height |
59 | RCC Cable trench (1:2:4) for laying of 11 KV XLPE Power Cable and control cable from power transformer, VCB and other equipments to control room and for outgoing cables from control room to outgoing structures including GI perforated trays and cable duct covers (cable duct covers should be framed using angle 50x50x6 mm and 10 mm Tar Steel including excavation and disposal of un-wantedsoil. |
60 | 33/11 KV power Transformer Foundation |
61 | 33 KV Equipment Foundation & Gantry foundation |
62 | Earthing mat (GI Flat 75 mmx8mm) and filling of good earth |
63 | GI Earthing Electrode (3m long 32mm dia) through GI Strip |
64 | 33 KV yard Concreting with 2" gravel of 20 mm on top, 3"" concrete in the ratio of 1:2:4 mix (M-15) beneath and 3"" gravel of 40 mm beneath the concrete layer |
65 | Bore well with submersible pump |
66 | Design, Engineering and construction of Air Conditioned Control Room building (4 Nos ACs of 2 Ton Capacity) consisting of RCC Slab including trenches, comprising of Battery room, panel room, toilet complete in all respect with aluminum doors and windows, stair case, underground sewage tank, under ground water tank, overhead watertank, Motor pump for water lifting as required of overall building or as per electrical requirement (single storey including all internal services like water supply including supply and fixingof pipes, water taps etc., electric fitting including wiring withfans, lights & switches, sewerage system, finishing plinth protection including supply of construction material, labour, cement, reinforcement steel, frame work etc complete in all respect |
67 | Design, Engineering and construction ofShift Quarters for JE and SBA building consisting of RCC Slab, Bathroom, complete in all respect with aluminum doors and windows, stair case, underground sewage tank, overhead watertank, Motor pump for water lifting as required of overall building or as per electrical requirement (single storey including all internal services like water supply including supply and fixingof pipes, water taps etc., electric fitting including wiring withfans, lights & switches, sewerage system, finishing plinth protection including supply of construction material, labour, cement, reinforcement steel, frame work etc complete in all respect |
68 | Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains alongwith concreting of area from gate to yard and control room, complete in all respect |
69 | Yard Lightening with 9 Mtr 4 Nos. high mask fitted with 4 Nos. 100 Watt LED Light on each pole complete with bracket Clamp & earthing and service cable alongwith control board. |
70 | a) Battery Bank 30 V, 100AH, of 150 No. Cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant. B) 30V, 100AH, Float-cum- Boost Charger with Full wave rectification for 220V,1 Phase , 50 HZ AC input supply. |
71 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Power Coated, Degree of protection IP43 for 2 No Battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double Bus Bar of adequate size , 12 No. DP DC MCB (0-32A) including indication lamps and cables and other accessories |
72 | Distribution Panel (415 V, Dc) made of CRCA thickness not less than 2mm. Power Coated, Degree of protection IP43.200 Amps Switch Fuse disconnect or for incoming supply and 5 No TPN MCB"s (16-125 Amps) and 5 No DP MCB"s (0-32A), rectangular Busbar suitable for 200Amps continuous Supply including indication lamps and cables and other accessories |
73 | Telecommunication Facilities & Wifi Facilities |
74 | Rubber mat 1mx2m 19mm thick |
75 | Fire Extinguisher Co2 Type of 4.5 kg capacity for control room |
76 | 3 sand Bucket Fire Extinguisher |
77 | Helmet |
78 | Rubber Gloves for 33KV level |
79 | Rubber Gloves for 11KV level |
80 | Safety belt |
81 | Safety Shoes |
82 | Earthing Rod ( set of 3 rods) |
83 | HV Detectors all Voltages |
84 | Separate earthings of equipments through G.I. Strip 25x3 mm. |
85 | Servo Transformer 11/0.433kV 100 KVA |
86 | Part-Spares Transformer Oil |
87 | Outdoor CT 600/300/5 Amp |
88 | HT & LT Bushing of Transformer each |
89 | 11 KV VCB Trolley with Vacuum Interrupter complete |
90 | Digital Earth Clamp Tester |
91 | Tool Kit Complete including different types of spanners, drill machine, wrenches, plier and all other allied material |
92 | Office Table with Chair (1+5) |
93 | Branded Steel Almirah Full size |
94 | 10 KV Digital I R Tester Megger /Motwane / any other reputed make approved by CEA / PGCIL |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy