Tender For Provision Of Grass Carpet For Corps Hq Lawn Additional /Alternator To Bldg No Op T 240 Of Corps Hq Under Age Br I At Rms, Shillong-Meghalaya

Military Engineer Services-MES has published Tender For Provision Of Grass Carpet For Corps Hq Lawn Additional /Alternator To Bldg No Op T 240 Of Corps Hq Under Age Br I At Rms. Submission Date for this Tender is 23-09-2023. Carpets Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

39349950
Corrigendum : Tender For Provision Of Grass Carpet For Corps Hq Lawn Additional /Alternator To Bldg No Op T 240 Of Corps Hq Under Age Br I At Rms
Open Tender
Indian
Meghalaya
Shillong
23-09-2023

Tender Details

Tender For Provision Of Grass Carpet For Corps Hq Lawn Additional / Alternator To Bldg No Op T 240 Of Corps Hq Under Age Br I At Rms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Aug-2023 AMENDMENT IN BOQ FOR PROVN OF GRASS CARPET FOR CORPS HQ LAWN ADDN ALT TO BLDG NO OP T 240 OF CORPS HQ UNDER AGE BR I AT RMS BOQ 13-09-2023
2 08-Sep-2023 AMENDMENT IN DATES FOR PROVN OF GRASS CARPET FOR CORPS HQ LAWN ADDN ALT TO BLDG NO OP T 240 OF CORPS HQ UNDER AGE BR I AT RMS Date 23-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 82300.0 /-
Tender Value
INR 41.15 Lakhs /-

BOQ Items

Name of Work: PROVN OF GRASS CARPET FOR CORPS HQ LAWN & ADDN/ALT TO BLDG NO OP/T-240 OF CORPS HQ UNDER AGE BR-IAT RMS.
Sl. No. Item Description
1Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
2Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and directed.
3Dismantling, floor, hearth or wall tiling including cement mortar bedding etc complete all as specified and directed.
4Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets etc complete all as specified and directed.
5Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and directed.
6Taking down Chowkhat or frames exceeding 1.5 Sqm each with shutters (Without taking off shutters from the frames etc complete all as specified and directed.
7M&L for brick work with sub class "B" bricks (using old size burnt bricks) straight or curved on plan exc. 6.00m meanradius built in cement mortor (1:6) etc complete all as specified and directed.
8S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
9S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,valley gutter etc fixed with self tapping screws etc complete all as specified and directed.
10S & F for 10 mm thick of size 600x600mmacoustic ceilingboard to be fixed or laid withGI / Aluminium frame grid/ section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19x0.9 mmduly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size etc complete all as specified and directed.
11S&F bonded mineral wool blanket slab 25mm thick made from glass density 24 kg/cum and fixed as per manufacturer’s instructions etc complete all as specified and directed.
12S&F for5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing etc complete all as specified and directed.
13M&L for Solid PVC Wall Lining consisting of 5mm thick Plain or coloured with wood grains printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame etc complete all as specified and directed.
14S&F of PVC (SWR) 75 mm dia pipe etc complete all as specified and directed.
15S & FPVC (SWR) Band any radious of 75 mm dia etc complete all as specified and directed.
16S & F PVC (SWR) Junction(Single"T" ) equal or un equal of75mm diaetc complete all as specified and directed.
17S&F dark shadevitrified ceramic tiles 10mm thick , area exc 0.18 sqm but n.exc 0.36 Sqm each as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed.
18All as per ItemNo 17.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM 1:3.
19M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc laid over and including 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:4) etc complete all as specified and directed.
20All as per ItemNo 19.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM 1:4.
21M&L for Glazed ceramic colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles , laid over and including 10mm thick CM (1:4) backing coat etc complete all as specified and directed.
22S&F anodised aluminium powder coated any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
23S&F for anodised aluminium powder coated any colour door shutter, aluminium section weighting 0.55 kg/m including necessary joining, cleats,glazing clips,rubbber neoprene, packing headls 2 nos in each door hinges anodised aluminium snap beading screw etc complete all as specified and directed.
24S & F for aluminium Window and ventilator sliding shutters, without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
25S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination , fixed with screws to timber/ aluminium frame work and sealing edges of board with PVC beading by chemical adhesive etc complete all as specified and directed.
26S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane etc complete all as specified and directed.
27S&Ffor aluminium (extruded section) bodydoor closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed etc complete all as specified and directed.
28S&F Mortice lock,vertical type Brass 2 levers, size 100 mm etc complete all as specified and directed.
29S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed.
30S&F Factory made solid panel pvc doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site etc complete all as specified and directed.
31S & F 100 size stainless steel butt hinges complete all as specified and directed
32S/F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long etc complete all as specified and directed.
33S&F Aluminium handle cast type anodised 150 mm long etc complete all as specified and directed.
34Taking upor down 15 mm GI steel tubing and connections etc complete all as specified and directed.
35Taking upor down steel tubing and connections i with all fittings for 20 mm bore GI tubing etc complete all as specified and directed.
36S&F 15mm bore GI water tubing medium grade laid in floors or fixed in wall including GIfittings etc complete all as specified and directed.
37S&F 20 mm bore GI water tubing medium grade laid in floors or fixed in wall including GIfittings etc complete all as specified and directed.
38S&F vitreous China Urinal, Half stall sensor based type, white (excluding flushing cistern, flush pipe)including taking down old ), white, complete including providing and fixing plugs, bedding urinalagainst wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back with grating and union for discharge pipeand waste pipe complete all as specified and as directed. (Make : CERA, Item Code 113692077 or equivalentas approved by GE.
39S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium platedscrewed down, screwed for iron pipe or for brass ferrule and fixed etc complete all as specified and directed.
40S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm longfixedwith two plugs (Gutties) of 2nd class hard woodembeded in cement mortor 1:3 with MS screws etc complete all as specified and directed.
41S&F in repairs corner glass shelf assembly 250mm radius made of 6mm thick craaylic glass, with CP railing, fixed with suitable rowal plug & screws etc complete all as specified and directed.
42Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
43M & L rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement etc complete all as specified and directed.
44M&L for rendering 15mm thick in CM 1:4 other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
45M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint etc complete all as specified and directed.
46M&L for applying two coats of oil bound distemper over one coat of primer over a coat of 3mm thick wall care putty on new plastered surfaces of walls including preparation of newsurface complete all as specified and directed.
47Material and labour for preparation of new external surfaces of walls including cornices, plasters etc (Plastered or un plastered surfaces) and applying two coats of cement paint over a coat of primer complete all as per manufacture instructions all as specified and as diredted by Engineer-in-Charge .
48M &L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint etc complete all as specified and directed.
49Material and labour for preparation of old external surfaces of walls including cornices, pillasters etc (Plastered or un plastered surfaces) and applying a coat of cement paint including complete removal of existing treatment all as per manufacture instructions all as specified and as diredted by Engineer-in-Charge .
50M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one or more coat on old surfaceof french polishing etc complete all as specified and directed.
51M&L forchequered cement concrete tiles 200x200x25mm thick with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments etc complete all as specified and directed.
52M&L cement concrete type C-2 (1:3:6) (using 40 mm graded stone agg) as in surface channels and drains etc complete all as specified and directed.
53M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds etc complete all as specified and directed.
54M & L for PCC 1:3:6 type C-2, 75 mm thick (using 40 mm graded stone aggregate) as in plinth protection/hardstanding etc complete all as specified and directed.
55S&F Decorate type blinds vertical or horizontal for windows of any size and any colour, inside or outside mount, gives a neat and modern look, heat and UV reduction, made up with polyester or solid weave fabric, controlling the direction of light entering the room for blackout, dim out and sheer with all components and accessories like puulling cord, chain, plastic and iron roller bind control unit set, blind clips etc all as per manufacturers instruction and as directed by Engineer- in- Charge.
56M&L for RCC Nominal Mix Type A-1 (1:1.5:3) (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
57M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, laid over and including 20mm thick screed bed/bedding layer in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as "specified and as directed.
58S & F in repair stainless steel sink, 1mm thick for kitchen with draining board with plug and PVC waste pipe including bedding in cement mortar, fixing brackets overall size 915x460mm, bowl size 410x330x 160mm, asfixed in repairs complete all as specified and directed.
59Supply and fixing stainless steel (conforming to AISI-304 grade) plate rack of overall size 750mm x 600mm x 254 mm or equivalent made of 1mm thick stainless steel sheetfixed on CP cantilever brackets, complete all as specified and as directed. Make : Jayna Cat No SBSD-05 or equivalent as approved by GE.
60M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for colums,hooking ends, and including mild steel wire not less than 0.9mm dia or securing with clips quality conforming to IS etc complete all as specified and directed.
61M&L form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) etc complete all as specified and directed.
62S&F 40 mm flap width of Continuous (piano) hinges, mild steel, bright finish or electrogalvanised etc complete all as specified and directed.
63M&L for 19mm thick Block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face fixed with screws to timber framework etc complete all as specified and directed.
64S & F external teak wood lipping, 6mm thick, fixed with nails complete all as specified and directed.
65S&F 40 mm cupboards knobs fixed with nut screw and washer of brass polished complete as specified and directed.
66S&F magnet Catcher for cub board complete all as specified and directed.
67S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringsetc complete all as specified and directed.
68Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil etc complete all as specified and directed.
69Supply & laying of lawn area and planting of carpet American Grass over and including approved earth/fertile soils after treating the soil bed with Chlorpyrifos 20 EC or equivalent chemical as per manufacturer recommendation or as approved by GE , and organic fertilizer or cow dung with soil in 1:3 portion (1 part of cow dung and 3 parts of approved soil) including water spraying etc complete all as specified and directed.
70M&L for approved earth/Fertile soils or Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, rolled , levelled and rammed including watering etc complete all as specified and directed.
71Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:4)complete all as specified and as directed.
72M&L for Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
73Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/Loose soil etc complete all as specified and directed.
74Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm hard/dense soil etc complete all as specified and directed.
75Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting pointetc complete all as specified and directed.
76M&L for three coats of white wash on new plastered surface on walls including prepration of surfaces .
77M&L for PCC 1:2:4, Type B-1,(using 20mm graded stone aggregate) as in coping etc complete all as specified and as directed.
78Maintinance and cutting with one gardener per day after carpeting of approved grass over approved soiletc complete all as specified and as directed by Engr in Charge .
79Material and labour for (concelaed Type) point wiring including necessary chasis cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessories and making good the distrubed surfaces as per the existing etc complete all as specified and as directed by the Engr-in-Charge. Note: A. Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. B. The Rate of point wiring includes the following :- (i)Copper wire (ii)PVC Conduit with accessoreis (iii) Chase cutting
80(a) Onelight/fan/bell pointcontrolled by one, one way switch .
81(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
82(c) One 3 pin socket outlet 5 Amps on the Independent board.
83All as per item No- 79.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
84M&L for Modular Switch 1 way 6A,1 module etc complete all as specified and as directed by the Engr-in-Charge.
85M&L for Modular Bell Push 6A,1 moduleetc complete all as specified and as directed by the Engr-in-Charge.
86M&L for modular switch 1 way 16A, 1 module etc complete all as specified and as directed by the Engr-in-Charge.
87M&L for Modular Socket ,6A/2/3 pin combined 2 module etc complete all as specified and as directed by the Engr-in-Charge.
88M&L Modular Socket ,6A/16A-2/3 pin combined 2 module etc complete all as specified and as directed by the Engr-in-Charge.
89M&L Modular stepped type electronic fan regulator 120 Watt socket size flush type on the existing phenolic laminated sheet etc complete all as specified and as directed by the Engr-in-Charge.
90M&L for Bell Multi Music type etc complete all as specified and as directed by the Engr-in-Charge.
91M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body etc complete all as specified and as directed by the Engr-in-Charge.
92S&F for modularTelephone socket etc complete all as specified and as directed by the Engr-in-Charge.
93S&F for modular TV socket complete all as specified and as directed. Make : Anchor/Havells/Legrand
94S&F for LED Light fitting 1 x 20 watt (4 Ft),Wall mounted decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack etc complete all as specified and as directed by the Engr-in-Charge.
95S&F for LED Light fitting 1 x 10 watt (2 Ft),Wall mounted decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack etc complete all as specified and as directed by the Engr-in-Charge.
96M&L for sub main wiring with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping/Conduit pipe including complete all as specified and as directed. NOTE:- Two runs of 4.0 Sq mm +one run of 4.0 Sq mm and one run of PVC casing & capping/Conduit pipe and its accessories of suitable size shall be measured as one unit length.
97M&L for sub main wiring with four runs of 6.0 Sq mm and two run of 6.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping/Conduit pipe including complete all as specified and as directed. NOTE:- Four runs of 6.0 Sq mm + two run of 6.0 Sq mm and one run of PVC casing & capping/Conduit pipe and its accessories of suitable size shall be measured as one unit length.
98Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free warm white light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size etc complete all as specified and as directed by the Engr-in-Charge.
99Supply and fixing for LED 12 watt Picture light/Mirror light complete all as specified and as directed. Make : Havells/Crompton/Bajaj/Philips
100Supply and fixing for 6 Watt LED antique copper gold Focus spot ceiling wall light warm white complete all as specified and as directed. Make : Havells/Crompton/Bajaj/Philips
101Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and as directed by the Engr-in-Charge.
102Supply and fixing for LED 3 Watt Decorative wall Mount light Fancy type,etc complete all as specified and as directed by the Engr-in-Charge.
103M&L for modular metal flush box 2 module complete all as specified and as directed
104M&L for modular metal flush box 3 module complete all as specified and as directed
105M&L for modular metal flush box 6/8 module complete all as specified and as directed
106M&L for modular white cover plate with frame 2 module complete all as directed.
107M&L for modular white cover plate with frame 3 module complete all as directed.
108M&L for modular white cover plate with frame 6 module complete all as directed.
109M&L for modular white cover plate with frame 8 module complete all as directed.
110M&L for VTPN DPX 4 way,double door 415 Volts, 50 Hz, IP 43 IK 09 sheet steel, powder painted, with02 neutral link & 02 earth bar and cable ties for cable managementsuitablefor fixing ofMCCB asincomer and MCB SP/TP as outgoing MCB DBs complete all as specified and as directed.
111Supply and fixingMCCB 3 Pole .415 Volts fixed type, 100 Amps with breaking capacity 16 KAcomplete with connection testing and commissioningetc complete all as specified and as directed by the Engr-in-Charge.
112M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity MCB DBs etc complete all as specified and as directed by the Engr-in-Charge.
113M&L for MCB SPN 40-63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" seriesinclMCB etc complete all as specified and as directed by the Engr-in-Charge.
114M&L for MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" seriesMCB etc complete all as specified and as directed by the Engr-in-Charge.
115Supply and fixing for Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB TP 32 Amps etc complete all as specified and as directed by the Engr-in-Charge.
116Supply and fix Rigid non-metallic PVC conduit 25 mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends, junction boxes and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed by the Engr-in-Charge.
117Supply and fix Rigid non-metallic PVC conduit 40 mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends, junction boxes and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed by the Engr-in-Charge.
118Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm etc complete all as specified and as directed by the Engr-in-Charge.
119M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type mounted on insulators, where ever applicable
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail