| 1 | Supply of RTU System for PH-II STPS, Sarni as per Annex. A |
| 2 | 220KV ECR PH-2Remote Terminal Unit complete withCPU, Power Supply, Analog Input Module, Digital Input Module, Communication Module, RTU Cabinet, SIC Cabinet, relays, terminal blocks, complete wiring. Remote terminal unit(RTU Module)Features:- I/O points:-(i) DI=38(ii) DO=00(iii) AI=20 Communication port :-(i)06 Nos. Ethernet port for IEC-104/ 61850( 4 port used for master communication +1 Port For LDMS + 1 Portfor configuration )(ii) 04 NosRS232/RS485 port forMFM(iii) DI Card- 2 nos (32 Channel) and AI Card- 2 Nos (12 Channel)(iv) CMR- 38 Nos Protocol:-(i) IEC 61850 client(ii) IEC60870-5-103client(iii) Modbus RTU client(iv) IEC 60870-5-101 slave (v) IEC60870-5-104 slave |
| 3 | MFMs for RTUs |
| 4 | LDMS -i7 Processor , 6 GB Ram , 1 TB HardDiskwindow 10/11 with LDMS Software |
| 5 | PLCC Modem for each end |
| 6 | Cables |
| 7 | Cable for digital input from C&R panel toRTU (10 Core 1.0 Sq mm) |
| 8 | Cable for analoginput from C&R panel toRTU (2 pair1.0 Sq mm) |
| 9 | Cable for DC distribution board to RTU forPower Supply (2 Core 2.5 Sqmm) |
| 10 | Cable for ACdistribution board to RTU forPower Supply (3Core 2.5 Sqmm) |
| 11 | Armour Cable for communication from communciation panel to RTU (2 Pair X 1Sq.mm) for Station Transformer 3 & 4 |
| 12 | Cable for digital input from C&R panel toRTU (10 Core 1.0 Sq mm) for Station transformer 3&4 |
| 13 | Communication from Existing Energy meters to RTU (2 Pair X 0.5 Sq.mm) for real time data transmission of Energy meters. |
| 14 | Cat 6 Cable for LDMS |
| 15 | Cablefor CT & PT input MFM (4 Core 2.5 Sqmm) |
| 16 | Supply of RTU System for PH-III STPS, Sarni as per Annex. B |
| 17 | 400KV ECR PH-3Remote Terminal Unit complete withCPU, Power Supply, Analog Input Module, Digital Input Module, Communication Module, RTU Cabinet, SIC Cabinet, relays, terminal blocks, complete wiring. Remote terminal unit(RTU Module)Features:- I/O points:-(i) DI=58(ii) DO=00(iii) AI=19 Communication port :-(i)06 Nos. Ethernet port for IEC-104/ 61850( 4 port used for master communication +1 Port For LDMS + 1 Portfor configuration )(ii) 04 NosRS232/RS485 port forMFM(iii) DI Card- 2 nos (32 Channel) and AI Card- 2 Nos (12 Channel)(iv) CMR- 58 Nos Protocol:-(i) IEC 61850 client(ii) IEC60870-5-103client (iii) Modbus RTU client(iv) IEC 60870-5-101 slave(v) IEC60870-5-104 slave |
| 18 | MFMs for RTUs |
| 19 | LDMS -i7 Processor , 6 GB Ram , 1 TB HardDiskwindow 10/11 with LDMS Software |
| 20 | PLCC Modem for each end |
| 21 | Cables |
| 22 | Cable for digital input from C&R panel to RTU(10 Core 1.0 Sq mm) |
| 23 | Cable for analoginput from C&R panel to RTU(2 pair1.0 Sq mm) |
| 24 | Cable for DC distribution board to RTU forPower Supply (2 Core 2.5 Sqmm) |
| 25 | Cable for ACdistribution board to RTU forPower Supply (3Core 2.5 Sqmm) |
| 26 | Communication from communication panel toRTU (2 Pair X 0.5 Sq.mm) for MFM and Energy Meters |
| 27 | Armour4 Core FO Cable |
| 28 | Optical to Serial converterwith LIU and Patchcord |
| 29 | Cablefor CT & PT input MFM (4 Core 2.5 sqmm) |
| 30 | Cat 6 Cable for LDMS |
| 31 | Supply of Mandatory Spare as per Annex. C |
| 32 | Power Supply unit for RTU |
| 33 | CPU for RTU |
| 34 | Analog Input Card |
| 35 | Digital Input Card |
| 36 | Modem set including power supply unitseparately quantity for RTU end |
| 37 | Modem set including power supply unitseparately quantity for Master end |
| 38 | Communication Module for communicatingwith multifunction meter |
| 39 | Multifunction Meter |
| 40 | CMR |
| 41 | Laptop for configuration and Maintenance tool as per Annex. C |
| 42 | Portable RTU Configuration and Maintenance Terminal(i7 processor, 6 GB RAM, 1 TB HARD DISK,WINDOWS 11, 15.6 INCH, DELL / HP MAKE) |