}

Tender For Two Year Rate Contract For The Procurement Of Joint Replacement Implants, jaipur-Rajasthan

Sawai Man Singh Medical College has published Tender For Two Year Rate Contract For The Procurement Of Joint Replacement Implants. Submission Date for this Tender is 21-09-2023. Orthopedic equipment Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39337361
Tender For Two Year Rate Contract For The Procurement Of Joint Replacement Implants
Tender
Indian
Rajasthan
Jaipur
21-09-2023

Tender Details

Two Year Rate Contract For The Procurement Of Joint Replacement Implants , Total Hip Replacement ( Thr ) – All Sizes Un Cemented: - ( Metal On Poly ) All Should Be Of Same Make Implant Should Be Usfda Approved Only The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating, Ha Coating Of 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed, Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners. The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. Insert Should Be Highly Cross Linked Polyethylene.The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. Femoral Heads Should Be Cocr Metal Head With All Sizes 28Mm / 32Mm / 36Mm , Total Hip Replacement ( Thr ) – All Sizes Un Cemented: - ( Ceramic On Poly ) All Should Be Of Same Make Implant Should Be Usfda Approved Only The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating, Ha Coating Of 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed, Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners. The Acetabular Shell Should Have Minimum 3 Hole Options. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. Insert Should Be Highly Cross Linked Polyethylene.The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. Femoral Heads Should Be Ceramic With All Sizes 28Mm / 32Mm / 36Mm. , Total Hip Replacement ( Thr ) – All Sizes Cemented: - With Metal On Poly. Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design. • The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In The I.D 28 / 32 / 36 Mm With Od 46 – 60 Mm With Two Packets Of Bone Cement. , Total Hip Replacement ( Thr ) – All Sizes Hybrid ( Metal On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners. The Acetabular Shell Should Have Minimum 3 Hole Options. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. • Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design With Required Bone Cement. • Insert Should Be Highly Cross Linked Polyethylene.The Polyethylene Has 10-Degree Or Moreposterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. • Femoral Heads Should Be Cocr Metal With All Sizes 28Mm / 32Mm / 36Mm Note: - All Should Be Of Same Make , Total Hip Replacement ( Thr ) – All Sizes -Hybrid: ( Ceramic On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners. The Acetabular Shell Should Have Minimum 3 Hole Options. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. • Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design With Required Bone Cement. • Insert Should Be Highly Cross Linked Polyethylene.The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. Femoral Heads Should Be Ceramic With All Sizes 28Mm / 32Mm / 36Mm. , Total Hip Replacement ( Thr ) Dual Mobility Uncemented– All Sizes ( Metal On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Have Minimum 3 Hole Options. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. The System Should Compose Of A Liner And Poly Insert. The System Should Incorporate The Following Dual Points Of Articulation- • 22.2Mm Or 28Mm Femoral Metalhead. • Large Polyethylene Insert That Mimics A Femoral Head Dual Mobility Liner- • Dual Mobility Liner Should Be Made Of Cocr. • The System Should Have Inner Change Locking Mechanism And Positive Rotation Tabs • The Liner Should Come With Removal Tool Slot. • The Liner Should Be Available In All Sizes- 36 To58 Poly Insert- The Insert Should Be Made Up Of Highly Cross Linked Polyethylene Which Should Be Wear Resistant , Total Hip Replacement ( Thr ) Dual Mobility Uncemented– All Sizes ( Ceramicon Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Ha Coated. The Acetabular Shell Should Have Minimum 3 Hole Options. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. The System Should Compose Of A Liner And Poly Insert. The System Should Incorporate The Following Dual Points Of Articulation- • 22.2Mm Or 28Mm Femoral Ceramic Head. • Large Polyethylene Insert That Mimics A Femoral Head Dual Mobility Liner- • Dual Mobility Liner Should Be Made Of Cocr. • The System Should Have Inner Change Locking Mechanism And Positive Rotation Tabs • The Liner Should Come With Removal Tool Slot. • The Liner Should Be Available In All Sizes- 36 To 58 Poly Insert- The Insert Should Be Made Up Of Highly Cross Linked Polyethylene Which Should Be Wear Resistant. , Total Hip Replacement ( Thr ) Dual Mobility Cemented – All Sizes ( Metal On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • Cemented Dual Mobilty Should Have Sizes 45 To 63 • Head Sizes 22 And 28 With 4 Option • Can Be Converted With Uncemented Dm With Same Instruments On Table , Total Hip Replacement ( Thr ) Dual Mobility Cemented – All Sizes ( Ceramic On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • Cemented Dual Mobilty Should Have Sizes 45 To 63 • Head Sizes 22 And 28 With 4 Option • Can Be Converted With Uncemented Dm With Same Instruments On Table , Total Hip Replacement ( Thr ) Dual Mobility Cemented – All Sizes ( Ceramic On Poly ) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only • Cemented Dual Mobilty Should Have Sizes 45 To 63 • Head Sizes 22 And 28 With 4 Option • Can Be Converted With Uncemented Dm With Same Instruments On Table , Revision Uncemented Stem Should Be Long And Length Should Be Between 180 - 380 Mm, Modular Or Distal Fixing Stem. , Revision Uncemented Acetabular Shell Have Multi Hole With Min. 8 Holes And Ha Coated. , Cup Should Be Have Highly Porous Coating. , Revision Uncemented Acetabular Shell Should Provide Dual Mobility Cup Which Composed Of Cocr Liner And Highly Crossed Linked Polyethylene Which Support 22- And 28-Mm Femoral Metal Head. ( Optional ) , Would Also Require Acetabular Wedges , Acetabulum Augments , Acetabulum Mesh. , Acetabulum Cages , Uncemented Acetabular Shell Especially Designed For Protrusion Which Is Peripherally Locking. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Revision Cemented Stem Should Long And The Length Would More Than 200 Mm, With Bone Cements. , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene With Pmma Cementspacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In The I.D 28 / 32 / 36Mm With Od 46 – 60 Mm. , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating, Ha Coating Of 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed, Incremental Neck Lengthoptions, Two Offset Options And Made Up Of Ti6al4v Material , Femoral Heads Should Be Cocr Metal Head With All Sizes 22Mm / 28Mm / 32Mm / 36Mm. , Insert Should Be Highly Cross Linked Polyethylene.The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 28Mm / 32Mm / 36Mm. , Total Knee Replacement Cemented ( Tkr ) – All Sizes Note: - All Should Be Of Same Make Should Provide Both Ps And Cr Knee Implant Should Be Usfda Approved Only I. Primary Cemented Tkr- Ps Consists Of Femoral Components, Tibial Baseplate, And Highly Crossed Linked Polyethylene Ii.Primary Cemented Tkr Cruciate Retaining ( Cr ) System Iii. Bone Cement Note: - All Should Be Of Same Make , Unicondylar Knee Replacement Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only I. Fix Bearing Ii. Mobile Bearing , Complex Primary Knee Replacement All Size And Stems And Wedges Cemented Tkr Should Have Following Components Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only I. Femoral Components Compatible With Stem Extension I. Tibial Baseplate Compatible To Stem Extension Ii. Primary Highly Crossed Linked Polyethylene Iii. Bone Cement Antibiotic / Norma Iv. Fluted Stem , Revision Knee Replacement All Size And Stems And Wedges Semi Constraint Tkr Should Have Following Components Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only I. Femoral Component Compatible With Stem Extension. I. Tibial Baseplate Compatible To Stem Extension. Ii. Semi Constrained Highly Cross-Linked Polyethylene. Iii. Distal Augments. Iv. Posterior Augments V. Offset Vi. Tibial Full & Half Wedges Vii. Fluted Stem Viii. Bone Cement , Revision Knee Replacement All Size And Stems And Wedges Hinge Tkr Should Have Following Components Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only , Femoral Component Compatible With Stem Extension. , Tibial Baseplate Compatible To Stem Extension. , Constrained Highly Cross-Linked Polyethylene. , Distal Augments. , Posterior Augments , Offset , Tibial Full & Half Wedges , Fluted Stem , Bone Cement , Reverse Shoulder Replacement Implants – All Sizes All Should Be Of Same Make Implant Should Be Usfda Approved Only • Platform Based Should And Can Be Converted Total / Reverse And Evenrevision Glenoid Base At Same Stem. • 3 Types Of Stems Trauma / Ha And Cemented Stem.Stem Made Of Titanium Alloy ( Ta6v ) And Coated With Hydroxyapatite. • Stem Is Available In 5 Sizes . Long Stem Available For Humeral Revision Cases.Stem Has +10Mm Augment ( For If The Stem Has Sunk Or Any Unseen Circumstances ) . • Hydroxyapetitecoated , Helical Glenoid Baseplate For Reverse Shoulder Arthroplasty. • Should Have Glenoid Revision Base Plate Option. • Glenosphere Has To Be Min. 2 Sizes – 32Mm And 38Mm. • Should Have Instruments For Both Surgical Approaches :Delto-Pectoral Or Supero-Lateral Approaches With Same Set Of Instruments. • Humeral Cup Has 8” Inclination With 2 Sizes 32Mm And 37Mm And Humeral Cut Is At The Anatomic Value Of 132°. • Humeral Cup Liner Has 0 , +2.5 And +5Mm Three Options For Same Cup. , Total Shoulder Replacement ( Tsr ) Implants- All Sizes Implant Should Be Usfda Approved Only All Should Be Of Same Make • Should Have Peglenoid With At Least Three Sizes • Stem As Per Rsa Specs. , Hemi Shoulder Replacement Implants – All Sizes Including Fracture Stem All Should Be Of Same Make Implant Should Be Usfda Approved Only • Should Have Five Humeral Head Option • Should Have Module With Offset Option • Should Have Trauma Stem • Stem Should Be Titanium With Proximal Porous Plasma Spray Coating. • It Should Be Convertible From Total To Reverse Shoulder. • Diameter Should Be In 1Mm Increment Or 2 Mm Increment With Fracture Stems. • Can Be Used With Or Without Bone Cement. • Fins With Holes Should Be Present To Tie The Tuberosity In Fracture Stems , Total Elbow Replacement ( Ter ) – Implants – All Sizes Implant Should Be Usfda Approved Only All Should Be Of Same Make Total Elbow Replacement Set With Consisting Of Long Flange Plasma Spray Coated Humeral Stem And Side Specific ( Left / Right ) Plasma Spray Coated Ulnar Stem Component With Antibiotic Bone Cement Usfda Full Quality Assurance And Should Be Mri Compatible.

Key Value

Document Fees
INR 1000 /-
EMD
INR 1200000.0 /-
Tender Value
INR 6 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail