Defence Government Departments Closing in 0 days TDR #39335029

Tender For Construction Of 08 Bedded Mahila Barrack At Bop Jaitpur Of 121 Bn Bsf Under Shq Bsf Gsp (Sh - Ei And Fans I/C Service Connection)

Issued by Government Departments · jaitpur, Punjab
Tender Value
8.13 Lakhs
Estimated cost
Bid Submission
08 Sep 2023
0 days left
EMD
16270
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaitpur → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of 08 Bedded Mahila Barrack At Bop Jaitpur Of 121 Bn Bsf Under Shq Bsf Gsp ( Sh - Ei And Fans I / C Service Connection )

BOQ

Name of Work: C/O 08 Bedded Mahila Barrack at BOP Jaitpur of 121 BN BSF under SHQ BSF GSP (SH : EI & fans i/c Service connection).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group B)
2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 4 sq. mm
6Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ( 20 mm)
7Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
9Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
10Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
11Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
12Supplying and fixing PVC batten holder including connections etc. as required.
13Providing and fixing of 9/10 watt Led bulb in existing holder etc complete as required .
14Supply, installation, testing and commissioning of 20 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required.
15Providing and fixing of 1200 mm sweep BLDC ceiling fan , including wiring the down rods of standard length (upto 30 cm) including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
16Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V,300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required.
17Supplying installation testing and commissioning of wall fan 230V,400 mmsingle phase on the wall including connection testing and commissioning etc as required.
18Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100 lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required.
19Providing and fixing of 12 watt surface mounted LED fitting square/Round directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. .
20Providing and fixing of 50 watt LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, system efficiency >110/120LPW, 10KV SPDversion to be ordered separatelyincluding connection, testing commissioning etc as required.
21Providing and fixing of electric storage water heater of 25 ltr of 2 KW ,240 Volt ,50 HZ i/c fasteners with nut, bolts, washers and connection pipe with connection, testing commissioning etc as required .
22Providing and fixing of smart incinerator for disposal of used sanitary pads with suitable size of exhaust pipe including connection, testin & commissioning etc as required which having following technical specification below:-i) Watt-1200 Watt ii) Capacity -50-55 Pads/ day iii) Auto Cut off Function iv)Ash - after burn less than 1 gm/ Pad v) Dimension -220L X 220W X 360HVI ) Type - wall mounted
23Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. (For 4 way (4 + 12), Double door TPN MCB DB)
24Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door
25Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (For 10 way, Double door SPN MCBDB)
26Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2 + 8 way, Double door)
27Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole )
28Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Double pole )
29Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 15 KA - 18 KA,TPMCCB
30Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required
31Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
32Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
33Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
34Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (2 X 25 sq. mm (22mm)
35Providing and fixing of maintenance free, dust and moisture free,Engineering plastic injection moding Cooler Body, Cooling pad- 4D honey combo cellulose wet pad with anti bacterial resins fibre body ducting air cooler of following specification : Air flow 18000 CMH, Cooling area 2500 sqft (without ducting), Motor-Inverter high torque motor 380 to 415 volt/50 Hz, 1.1 Kw ( Single phase turbo axial fan) with 1400 RPM, , Air pressure - 180 P.A., Water tank capacity - 35 Ltr, Air outlet size - 670 mm x 670 mm,etc as per direction of engineer in charge. Make - Sky air cooler model URANUS or equivalent make and model in Symphony, Maharaja, Cool wind complete as per requirement or as decided by Engg-In-Charge.
36Providing and fixing of angle iron frame of suitable size for placing of duct cooler made out of 50 mm x 50 mm x 5 mm thick angle iron including making of stand as per site requirement and installation of duct cooler, as per direction of Engg- in -Charge,
37Suppling and making of duct made of 24 Gauge GSS sheet of suitable size as per site requirement andducting will be insulated with high quality insulating material etc as required as per direction of Engineer- in- Charge at site.
38Supplying and fixing of the heavy duty air controlling louvers/ shutters with manually operated adjustable blades complete with matelic frame as per site requirement.
39Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
40Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(i) 20 mm nominal dia Pipes
41Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer in Charge. Make : Syntex / Modi (Circular tank)
42Providing & fixing 1.5 KVA, 24 volt single phase PWM SOLAR power package 24 V rated solar power conditioning unit, 3X325 Wp Solar PV Module having nominal voltage 24V, 02 nos LMCA C-10 rated 12 V, 150 AH tubular maintenance free solar battery (05 year warranty)including galvanized iron stand, internal wiring withPVC insulated copper wire, junction box, civil work etc as per manufacturer specification required. The solar PCU unit should consists of following:-a)Solar charge controller:- Single phase solar charge controller based on PWM technology, max input PV Current40 A, , protection against overcurrent, battery over charge, PV/Battery reverse polarity, reverse current & High tempratureb) Inverter:- 24 V DC input and 220 V pure sine wave output at rated load 1 KVA @ .8 PF, efficiency>=85%c)Earthing:3 no\"s Chemical Earthing Material as per Roof top requirements Chemical Earthing System and Lighting arrestor with Stranded Copper wire. d)Wiring (Tin Coated UV protected DC Wire e) MC4 Connector/conduit/Cable tie/tray/wiringMake- As per manufacturer specification and as per direction of engineer in charge
43Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.A) All kinds of soil
44Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
451:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40mm nominal size Recycled Aggregate (RA)
46Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
47Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
48Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
49SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 200A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel.
50Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 4 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
51Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 4 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required.
52Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
53Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required.

AI Tender Summary

OUR REF NO 39335029
AUTHORITY Government Departments
TENDER VALUE 8.13 Lakhs
LAST DATE 08-09-2023
Authority
Authority Name Border Security Force
Work Description Construction Of 08 Bedded Mahila Barrack At Bop Jaitpur Of 121 Bn Bsf Under Shq Bsf Gsp ( Sh - Ei And Fans I / C Service Connection )
Basic Detail
Tender No 25/Engg.(E)/Tender/FTR PB/GSP/2023
Bidding Type Tender
Location
City jaitpur
State Punjab
Key Dates
Publish Date 25 Aug 2023
Submission Date 08 Sep 2023
Open Date 11 Sep 2023
Finance
Tender Value 8.13 Lakhs
Tender Fee Ref. Documents
EMD 16270
Exemption Not Available
Document List
BOQ_807901.xls
Tendernotice_1.pdf
8d2b07d7-1ed3-4c5c-84ff-1d6dae8eac14.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 11, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_807901.xls

pdf

Tendernotice_1.pdf

html

8d2b07d7-1ed3-4c5c-84ff-1d6dae8eac14.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders