Tender Forrepair/Maint Of Lt Panel, Ug Cable, Internal Wiring, Conversion Of Energy Efficient Led Light, Replacement Of Pipe Lines, Valves, Borewells, Ro Plant & Connecteditems, Dg Sets & Amf Controlpanels , Ac Plant At 44 Weu B And Certain E/M Works At A, anupgarh-Rajasthan

Military Engineer Services-MES has published Tender Forrepair/Maint Of Lt Panel, Ug Cable, Internal Wiring, Conversion Of Energy Efficient Led Light, Replacement Of Pipe Lines, Valves, Borewells, Ro Plant & Connecteditems, Dg Sets & Amf Controlpanels , Ac Plant At 44 Weu B And Certain E/M Works At A. Submission Date for this Tender is 25-09-2023. Electrification Work Tenders in anupgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39333337
Corrigendum : Tender Forrepair/Maint Of Lt Panel, Ug Cable, Internal Wiring, Conversion Of Energy Efficient Led Light, Replacement Of Pipe Lines, Valves, Borewells, Ro Plant & Connecteditems, Dg Sets & Amf Controlpanels , Ac Plant At 44 Weu B And Certain E/M Works At A
Open Tender
Indian
Rajasthan
anupgarh
25-09-2023

Tender Details

Repair / Maint Of Lt Panel, Ug Cable, Internal Wiring, Conversion Of Energy Efficient Led Light, Replacement Of Pipe Lines, Valves, Borewells, Ro Plant & Connecteditems, Dg Sets & Amf Controlpanels , Ac Plant At 44 Weu B And Certain E / M Works At Af Stn Anupgarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 62000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF LT PANEL, UG CABLE, INTERNAL WIRING, CONVERSION OF ENERGY EFFICIENT LED LIGHT, REPLACEMENT OF PIPE LINES, VALVES, BOREWELLS, RO PLANT & CONNECTEDITEMS, DG SETS & AMF CONTROLPANELS , AC PLANT AT 44 WEU B AND CERTAIN E/M WORKS AT AF STN ANUPGARH
Sl. No. Item Description
1(REPAIR/MAINT OF LT PANEL, UG CABLE, INTERNAL WIRING, CONVERSION OF ENERGY EFFICIENT LED LIGHT, REPLACEMENT OF PIPE LINES, VALVES, BOREWELLS, RO PLANT & CONNECTEDITEMS, DG SETS & AMF CONTROLPANELS , AC PLANT AT 44 WEU B AND CERTAIN E/M WORKS AT AF STN ANUPGARH)
2Taking down old unserviceable submainwiring aluminiumetc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified anddirected.
3M&L for sub main wiring (concealed ) with two single core 4 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25mm dia non-metallic PVC conduit fixed in wall including 4 sqmm copper earth continuity wire, accessories and connecting to earth dolly, completeall as specified anddirected by Engineer-in-Charge. Note :-2 runs of 4 Sqmm, 1 run of PVC conduit & 1 run of 4 Sqmmcable shall be measured as single unit length.
4M&L for Sub-main wiring (concealed) with two single core 6 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masnory including 25mm dia non metallic PVC conduit fixed in wall including 6 sqmm copper earth continuity wire, accessories and connecting to earth dolly , complete all as specified anddirected by Engineer-in-Charge. Note :-2 runs of 6 Sqmm & 1 run of 6 Sqmmcable and 1 run of PVC conduit shall be measured as single unit length.
5Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from sitecomplete all as specified anddirected
6M& L for Point wiring (concealed) complete with FRLS PVC insulated sheathed 1100 Volts grade, conforming to IS-694, 1.5 sqmm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic heavy duty rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including flush type metal boxes modular type suitable for fixing modular switches, sockets, fan regulator with white or any colour plate and 1.5 sqmm copper earth continuity wire connected to earth dolly complete for the following, complete all as specified anddirected by Engineer-in-Charge.
7One light/ceiling fan/exhaust fan point controlled by one switch, complete all as specified anddirected.
8One switch socket outlet3 pin 5 Amp on same board, complete all as specified anddirected.
9One 3 pin socket outlet, 5 amp point on Independent board, complete all as specified anddirected.
10One light point controlled by two 2-way switches, with cables, complete all as specified anddirected.
11All as per ser item No 5 above but 4 sqmm cable sizewith 2.5 sqmm earth continuity wire for one 3 pin socket outlet, 15 Amps on independent board.(AC/Geyser), complete all as specified and directed.
12All as per ser item No 5 above but 2.5 sqmm cable sizewith 2.5 sqmm earth continuity wire for one 3 pin socket outlet, 15 Amps on same board complete all as specified and directed. Note for Item No. 2 to 7 :- The disturbed surfaces of wall for concealing the wiring shall be made good by applying cement plaster, putty and colour wash etc to match with the existing surfaces. The quted rate shall include for the same.
13S&F switch piano type, single pole one way 6 Amps, 240 volts AC including taking down the old switch, complete all as specified anddirected
14S&F switch modular type, one modular single pole one way 6 Amps, 240 volts AC including taking down the old switch, complete all as specified anddirected by Engineer-in-Charge.
15S&F switch piano/modular type6 Amp single pole Two way 240V complete all as specified anddirected by Engineer-in-Charge.
16S&F Socket piano type single pole one way 6 Amps 2/3 pin 240 volts including taking down the old socket, complete all as specified anddirected by Engineer-in-Charge.
17S&F Socket modular type single pole one way 6 Amps 2/3 pin 240 volts including taking down the old socket, complete all as specified anddirected by Engineer-in-Charge.
18S&F Socket piano type 16 Amps, 3 pin combine, 2 module,240 volts, complete all as specified anddirected by Engineer-in-Charge.
19S&F Socket modular type 16 Amps, 3 pin combine, 2 module, 240 volts, complete all as specified anddirected by Engineer-in-Charge.
20S&F Switch Piano type 16 Amps, 1 module, 240 volts, complete all as specified anddirected by Engineer-in-Charge.
21S&F Switch modular type 16 Amps, 1 module, 240 volts, complete all as specified anddirected by Engineer-in-Charge.
22S&F Angle holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified anddirected by Engineer-in-Charge.
23S&F Ceiling rose, surface bakelite, 65mm x 50mm, three terminals, including connecting and testing, complete all as specified anddirected by Engineer-in-Charge.
24S&F 0-4 step modular type electronic regulator for ceiling fan 1200mm sweep, 240 volts, 100 Watts humfree single pole, complete all as specified anddirected.
25Taking down of existing ceiling fans, opening / dismantling of fan& fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canopy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces, complete all as specified and directed.
26Taking down old unserviceable light fitting and S&F 20/22 Watt LED Luminarie decorative box type (4feet) fitting inlcuding LED tube with blue coloured end caps pre wired for LED tube energy saving with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 2000 total lumen.The lamp shall be 1200 mm length with G13 base.The 20/22 Watt system shall be operating at 220-240V AC supply having internal driver, IP 20, surge protection 2 KV, ambient temperature -20 to 45 degree C, freequency 50 to 60 Hz, The system efficacy must be between 80-100 lumen/watt, with 70% lumen maintenance up to 40000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread, CRI minimum 80, PF should be greater than 0.95, THD <10%.individual LED,s should not be visible for glare free output colour temperature 6500k filled on & including 2 Nos PVC block of suitable size & connecting up to tube light fitting with connecting up with copper 3 core flexible white cord of min size of 0.5 sqmm complete all as specified anddirected. Make : CG Cat No CCS-103-20-65-SL-DP-NWH/ Havells/ Philips
27Taking down old unserviceable light fitting and S&F 09/10 Watt LED Luminarie decorative box type (2 feet) fitting inlcuding LED tube with any coloured end caps pre wired for LED tube energy saving with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 2000 total lumen.The lamp shall be 1200 mm length with G13 base.The 9/10 Watt system shall be operating at 220-240V AC supply having internal driver, IP 20, surge protection 2 KV, ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz, The system efficacy must be between 80-100 lumen/watt, with 70% lumen maintenance up to 40000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread, CRI minimum 80, PF should be greater than 0.95, THD <10%.individual LED,s should not be visible for glare free output colour temperature 6500k filled on & including 2 Nos PVC block of suitable size & connecting up to tube light fitting with connecting up with copper 3 core flexible white cord of min size of 0.5 sqmm complete all as specified anddirected. Make : Havells:Cat No LUMILINEBS10WLED865SPCWH/ CG/ Philips.
28Taking down old unserviceable light fitting and Supply, installation, Testing and commissioning of LED Bulk head 9/10 Watt with a nominal system lumen output of 600 lumens and a minimum system efficacy of 60 lm/W.The luminarie shall have a rated system lifetime of 50,000 burning hours at L70.The luminarie should have a color temperature of 6500K and CRI > 70.The luminarie shall meet IP 66 rating and IK 09 rating with THD < 20% and PF >0.9.The luminarie housing should made of high pressure die cast aluminium with polycarbonate front diffuser.The total power consumption should not exceed 10W complete all as specefied and directed. Make : Havells/CG/Philips
29S&F LED bulb 9/10watt with lumen 560, complete all as specified and as directed by Engineer-in-Charge. Make: Havelles Cat No LHLDDBEBBI8R009 or equivalent in CG, Philips.
30Taking down old unserviceable 2/4/6/8 way SPN/TPN/DBs alongwith MCB and making good disturbed surface of walls and floors for refixing or removal, Complete all as specified anddirected by Engineer-in-Charge.
31S&F sheet metal enclosure powder coated for MCB DB TPN 4 way double door with din rail and bus bar including concealed in walland making good to the disturbed surface matching with the existing complete all as specified and directed. Make :Standard/ Havells/Siemens/ L&T/ Legrand.
32S&F sheet metal enclosure powder coated for MCB DB SPN 8 way double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed. Make : Standard/ Havells/Siemens/ L&T/ Legrand..
33S&F sheet metal enclosure powder coated for MCB DB SPN 4 way double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete al las specified and directed. Make : Standard/ Havells/Siemens/ L&T/ Legrand.
34S&FMCCB 415 volts 16 KA four pole 100 Amps fixed type completeall as specified and directed.
35S&FMCCB 415 volts 16 KA four pole 150 Amps fixed type completeall as specified and directed.
36S&F MCCB 415 volts 25 KA four pole 200 Amps fixed type, completeall as specified and directed.
37S&FMCB TPN 63 Amps, C series, breaking capacity 10 KA, "C" curve 415 volts, 50 HZ completeall as specified and directed.
38S&FMCB TPN 40 Amps, C series, breaking capacity 10 KA, "C" curve 415 volts, 50 HZ completeall as specified and directed.
39S&F MCB SPN 240 volts 6 to 32 Amps breaking capacity 10 KA "C" Series rating completeall as specified and directed.
40S&Fin repair MCB SP, 6 to 32 Amps, C series, breaking capacity 10 KA, "C" curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etccomplete all as specified anddirected by Engineer-in-Charge.
41M&L for painting the internal and external surface of MS sheet metal enclosures of any size after scrapping, cleaning, dusting by applying two coats of synthetic enamel paints for 2/4/8 way DB complete all as specified anddirected by Engineer-in-Charge.
42Taking down old unserviceable light fitting and S&F 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 120 lumen/Watt (Minimum lumen output of luminarie should be 4500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection,PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided.Luminarie should have top maintainable driver compartment for easy access to driver during maintenance.The driver used must be a constant current driver with efficiency of > 85%.The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.Make : Crompton Cat No TRP-409-60-57-SL-GL-NSG/Havells/Philips
43M&L for Replacement of old unserviceable thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 240mmx130mmx95mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sqmm 04 core cable and including MCB SP, 6 to 32 Amp, C series, breaking capacity 10 KA, "C" curve 240 volts, 50 Hz complete all as specified and directed. Make- Sintex Cat No GSJB 2817. ISI marked
44S&F bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32mmx6mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings, complete with all as specefied and directed.
45S&F 2 core 4 sqmm PVC insulated PVC sheathed weather proof multistranded aluminium conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting complete all as specified anddirected.
46S&F 2 core 4 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting complete all as specified anddirected.
47Taking down existing old unserviceable underground LT cable size 300 Sqmm 4 corecomplete removalfrom trenches/ wall/pole completeall as specified and directed by Engineer-in-Charge.
48Taking down existing old unserviceable underground LT cable size 185 Sqmm 4 Core corecomplete removalfrom trenches/ wall/pole complete all as specified and directed by Engineer-in-Charge.
49Taking down existing old unserviceable underground LT cable size 150 Sqmm 4 Core corecomplete removalfrom trenches/ wall/pole complete all as specified and directed by Engineer-in-Charge.
50Taking down existing old unserviceable underground LT cable size 95 Sqmm 4 Core corecomplete removalfrom trenches/ wall/pole complete all as specified and directed by Engineer-in-Charge.
51Taking down existing old unserviceable underground LT cable size 25 Sqmm 4 Core corecomplete removalfrom trenches/ wall/pole complete all as specified and directed by Engineer-in-Charge.
52Taking down existing old unserviceable underground LT cable size 25 Sqmm 2 Core corecomplete removalfrom trenches/ wall/pole complete all as specified and directed by Engineer-in-Charge.
53Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm 4 core laid in trenches or under road complete all as specified and as directed
54Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 4 core laid in trenches or under road complete all as specified and as directed.
55Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sqmm 4 core laid in trenches or under road complete all as specified and as directed.
56Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 4 core laid in trenches or under road complete all as specified and as directed.
57Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core laid in trenches or under road complete all as specified and as directed.
58Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 2 core laid in trenches or under road complete all as specified and as directed.
59Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting outin soft/loose soil for removing/laying of cables complete all as specified and directed.
60Returning, filling including spreading , leveling , watering and well ramming in layers not exc 25 cm complete all as specified and directed.
61Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
62M&L for sand cushioning below and around cable in trenches with river sand complete all as specified and directed.
63M&L for brick of common burnt clay, sub class "B" old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed.
64Removing/Shifting and refixing of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopysloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3mm thick stainless steel sheet , factory made , aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, variousAmps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lampRYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes,suitable air ventilation fan and heater with sensorfor maintain temparature and anti moisture containt for PCC platform made out of 1:2:4 type B1 height 30 cm from GL and pedestal of 45 cm height from GL with suitable nut, bolts, washers etc., complete all as specified and directed. Note:- Location - SMC, Airmen, Tech Area
65Taking down unserviceable 3 Pole power contactor size FR3 with AC3 rating 45 Amp and AC1 85 Amp type MNX 45 three phase 415 volt 50 HZ suitable from Timer Box of Street light pole, complete all as specified and directed.
66S&F only 3 Pole power contactor size FR3 with AC3 rating 50 Amp & AC1 85 Amp type MNX 50 three phase 415 volt 50 HZ suitable for Timer Box of Street light pole, complete all as specified and directed. Make : L&T model No. CS 97075
67Taking down existing old unserviceable GI pipe 40mm dia complete removalfrom trenches complete all as specified and directed by Engineer-in-Charge.
68Taking down existing old unserviceable pipe 25mm dia complete removalfrom trenches complete all as specified and directed by Engineer-in-Charge.
69Supply, Laying, jointing & testing GI tubing medium grade of size 40mm dia bore laid in trenches including connection with all fittings as required complete all as specified and directed by Engineer-in-Charge.
70Supply, Laying, jointing & testing GI tubing medium grade of size 25mm dia bore laid in trenches including connection with all fittings as required complete all as specified and directed by Engineer-in-Charge.
71M&L in replacement of gun metal gate valve with iron wheel head screwed both ends size 40mm for iron/GI pipes complete all as specified and directed.
72M&L in replacement of gun metal gate valve with iron wheel head screwed both ends size 20mm for iron/GI pipes complete all as specified and directed.
73M&L in replacement of Ball brass valves dia 20mm , high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
74M&L in replacement of Ball brass valves dia 15mm , high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
75M&L in replacement of old unserviceable Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) capacity of 500 ltrs hoisted and fixed in position, complete all as specified and directed.
76M&L in replacement ofNon return sluice valve of dia 100mm for GI pipe as fixing complete all as specified and directed.
77M&L in replacement ofNon return sluice valve of dia 80mm for GI pipe as fixing complete all as specified and directed.
78M&L in replacement PVC suction hose pipe dia 100mm and length 30 mtr complete fitting to one end 7.5 HP motor and other end fitting foot ball complete all as specified and directed.
79Labour for complete service of RO Plant of capacity 250Ltr/hrs including replacement of all bag filters, cartidge filter, backwash of membrane (including chemical), tightning of all bends and coupling of PVC pipe etc, complete all as specified and directed by Engineer-in-Charge. Note : Spares shall be measured and paid separatly as supply only under subsquent items
80S&F Thermax industrial RO plant membrane model No. 40L30N (Pentair) complete all as specified and directed.
81M&L for replacement of wound filter Cartidge filter of 5µ (Microns) and filter media polypropylene Fiber Core size 40"X2.5"of RO plant of capacity 250 Ltr/hrs complete all as specified and directed.
82Supply only Chemical (sodium hydroxide citric acid) Anti scaling for RO Plant of capacity 250 Ltr/hrs, complete all as specified and directed.
83Supply only Chemical used for maintaining PH value RO water within permissible limit, complete all as specified and directed.
84Supply only activated carbon (GAC) for removing the impurities from water in the carbon filter of RO Plant, complete all as specified and directed.
85Labour only for arrangement of authorised engineer (service engineer of AC unit"s company having suitable licence) visit to identify the breakdown of any type of AC Plants and for PLC setting like temp/ voltage range setting and to carry out the neccesary repair up to the complete satification of Engineer in charge. Note : Any minor item needed to repair shall be included in quoted rate.
86Supply and charging of Refrigerent R-407 C in sealed container of 45kg complete all as specified and directed. Make:- Feron/Mafron/Mayfair Note:- Contractor will have to use sealed container and have to show weight of container before and after gas charging, so that exact weight of gas can be calculated.
87Cleaning and washing of microfilters of AHU of any capacities up to the satisfaction of Engineer In Charge including any other minor repair needed in AHU. Any broken filter shall be replaced with new one and same shall be paid, complete all as specified and directed.
88Descaling of condensor with the help of descaling chemical and nylon brush and cleaning of AHU filters blowers etc complete for the satisfaction of the Engr in charge of the 50 TR capacities of the AC plants of any make, complete all as specified and directed by Engineer-in-Charge.
89Cleaning of cooling tower with one or two as per existing size, water basin and makeup tank with the help ofchemical and nylon brush,removing and refixing of PVC finches after washing,cleaning of condenser pipe line( in letand out let) including painting of out side of cooling tower with inlet and out let pipe line with one coat synthetic enamel paint of colour approved by engr in charge and inside painting of water tank of cooling tower used water proof black japan paint one coat including changing of unserviceable PVC guard water distributor, PVC pipe, cooling tower motor etc complete for the satisfaction of the Engr-in-charge of the 50 TR capacity of the AC plantsat different locations complete all as specified and directed.
90Taking down old unserviceable butter fly valve and M&L for butter fly valve with rubber packing of size 100mm, complete all as specified and directed by Engineer-in-Charge.
91Taking down old unserviceable motor pump coupling set of any size and S&Ftesting and commissioning of new motor pump coupling complete set along with rubber star coupling suitable for any capacity centrifugal pump set complete all as specified and directed by Engineer in charge.
92Taking down old unserviceable motor pump coupling"s star rubber of any size and S&F testing and commissioning of new motor pump coupling"s star rubber set suitable for any capacity centrifugal pump set complete all as specified and directed by Engineer in charge.
93M&L for preparation of old painted surface of MS pipes and applying one coat of synthetic enamel paint, as per colour code given by the deptt , complete all as specified and directed by Engineer-in-Charge. Note :- The rates includes for writing and marking description of pipes with white synthetic enamel paint
94Taking down old unserviceable Fan coil unit of any size and S&F testing and commissioning of new Fan Coil Unit of 1200 CFM having single phase motor with double shaft complete all as specified and directed by Engineer in charge.
95Labour only for identification of breakdown of any type of AC Plants of any capacity and rectify the same with proper record mentioning time date and nature of defect duly signed by JE E/M and AGE E/M, complete all as specified and directed. Note:-(i) Spares required for major repair shall be paid separately. (ii) Contractor shall produce the register at the time of payment.
96Repair of the PLC based control module with digital display of Package/Central type AC unit suitable for any tonnage capacity having start/stop functions ,settings option to change the settings as per requirement, complete all as specified and directed.
97Taking down old unserviceable cooling tower motor"s cover/ umbrella of any size and S&F testing of new metalic cover of cooling tower motor for protection of motor from rain for any capacity cooling tower complete all as specified and directed by Engineer in charge.
98Removing old unserviceable thermal insulation and S&F of thermal insulation on ducts/chiller pipe line exposed to sun light using closed cell O nitrile rubber elastometric insulation of density 40-55 kg/m3, minimum thickness 20mm, thermal conductivity of 0.037 W/mk at 20 degree celcius mean temp and MZ 7000(without any additional vapour barrier)and with chemical treated factory laminated Woven fibre glass cloth with 200+/- 20 gsm to be applied on ducts manufactures reccomended rubber based adhesive in a blend of solvents complete all as specified and directed
99Supply, installation, testing and commissioning of acoustic insulation of pipe line with glass wool having thickness 25 mm resin bonded fibre glass, of 48 kg/cum density, covered with and 28 G Aluminium perforated sheetcomplete all as specified & directed by Engineer-in-Charge.
100Replacement of old unserviceable PVC float valve, S&F ofBrass float valve high pressure float and fly nut complete screwed pipe and fixed in 15mm/20mm dia bore pipe including taking down old unserviceable float valve, complete all as specified and directed by Engineer-in-Charge.
101S&F chilled water sensor as per existing specifications and make complete all as specified and directed by Engr in charge.
102Taking down old unserviceable fan bladeof any size and S&F fan blade of existing shape, size suitable for 50 TR cooling tower capacities complete all as specified and as directed.
103Taking down old unserviceable water sprinkler/ distribution system of any size and supply , fixing, testing and commissioning of newwater sprinkler/distribution system along with all connected accessories of existing shape, size suitable for 50TR cooling tower capacities complete all as specified and directed. Note:-Pipes shall be of thread type not shall be joined by solution but joined by screwing thread.
104Taking down old unserviceable cooling tower of any capacity and Supply installation testing and commissioning of FRP cooling tower of 50 TR suitable heat rejection capacity with FRP water basin PVC fills water distribution arrangement with self rotating sprinkleres staticaly and dynamically balanced axile flow fan direct driven,TEFC motor,suction screen,over flow and drain connections suitable GI inspection ladder,steel supporting structure,antivibration mounting etc.complete as per manufactures design/specifications for 50 TR capacity of Plant of water in is 35degree celcius and water out is 29.4degree celcius complete all as specified and directed.
105Taking down old unserviceable Air vent valve 15/20 mm and S&F testing of air vent valve 15 mm, complete all as specified and directed by Engineer-in-Charge.
106S&F over load relay 9 to 15 Amp,including taking down old unserviceable relay, complete all as specified and directed by Engineer-in-Charge. Make:- Model No.ML 2 of L&T or equivalent.
107M&L for replacement of control wiring of AHU and AC plant panel with suitable copper conductor with all necessary connections complete all as specified and directed by Engr-in-Charge.
108Disconnecting, dismantalling the defective three phase induction motor 415 Volts of fan motors 50 HZ of any RPM for following capacities and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material,varnish bearing connection plate and all other petty items required to make the motor functional and reassembling the motor including installation commissioning and testing on full load, complete all as specified and directed by Engineer-in-Charge.
1097.5 HP
1105 HP
111Disconnecting dismatiling of cetrifugal monoblock pump set of following capacities of pump any RPM and dismantiling defective parts such as impeller nut,glant,impeller key,gland packing water deflector bush bearings sleeve,gaskets,volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpsetis functional and reassembling the pumpset including installation commissioning and testing, complete all as specified and directed by Engineer-in-Charge.
1127.5 HP
1135 HP
114Labour only for identification of breakdown of any type and minor defect of DG of any capacity and make with proper record mentioning time date and nature of defect duly signed by JE E/M and AGE E/M,complete all as specified and directed Note:- (i) Spares required for major repair will be paid separately. (ii) Contractor will produce the register at the time of payment
115S&F luberication oil filter element with "O" ring as required at site for capacities of 160 KVA DG set complete all as specified and directed
116S&F luberication oil filter element with "O" ring as required at site for capacities of 20 KVA DG set complete all as specified and directed
117S&F Air filter elementinner and outer as required at site with "O" ring ofas required at site for following capacities of 160 KVA DG set complete all as specified and directed. Make:- MICO / Kirloskar / mahindra
118S&F Air filter elementinner and outer as required at site with "O" ring ofas required at site for capacities of 20 KVA DG set complete all as specified and directed. Make:- MICO / Kirloskar / mahindra
119S&F fuel filter element with "O" ring as required at site for capacities of 160 KVA DG sets, complete all as specified and directed. Make:- MICO / Kirloskar / mahindra
120S&F fuel filter element with "O" ringas required at site for capacities of 20 KVA DG sets, complete all as specified and directed. Make:- MICO / Kirloskar / mahindra
121S&F only ignition switch with key in repair for DG sets of 160 KVA & 20 KVA capacities complete all as specified and directed by Engineer-in-charge. Make:- MICO / Kirloskar / mahindra.
122Supply only lube oil SAE 15 W - 40for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling complete all as specified and directed by Engineer-in-charge. Make:- Castrol/Power Supreme
123Supply only top up coolent oil after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling for DG set radiator complete all as specified and directed by Engineer-in-charge.
124M&L for replacement of electronic automatic voltage regulator (AVR) of 50 V, 16 Amp suitable to DG Set of capacity 160 KVA including necessary terminals" sleeves etc as required at site of any type and make of DG sets, complete all as specified and directed.
125M&L for replacement of unserviceable/wornout control wiring of AMF panel of DG set with existing size of cable for complete AMF panel and testing complete for up to 160 KVA AMF panel complete all as specified and directed.
126S&Fengine start relay 24 volt DC suitable for AMF panels, complete all as specified and directed. Make:- Eagle Man/PIC
127S&Felectronic timer 24 volt (6 sec-60 sec) suitable for AMF panels, complete all as specified and directed. Make:- UG/PIC
128S&Findicator lamp assembly LED type with red/green/blue for phases R,Y,B complete all as specified and directed.
129Removing/refixing of AMF panel of DG set with existing size of cable for complete AMF panel for 160 KVA capacity of DG Set, including cable glands and lugs for incoming and out going cables,suitable air ventilation fan and heater with sensorfor maintain temparature and anti moisture containt for PCC platform made out of 1:2:4 type B1 height 30 cm from GL and pedestal of 60 cm height from GL with suitable nut, bolts, washers etc., complete all as specified and directed.
130M&L for Painting to outdoor/indoor type AMF panel box internally as well as external surfaces complete with two coat of synthetic enamelled paint over a coat of red oxide primer of approved colour including preparation of old surfaces of Panel complete all as specified and directed.
131Taking down unserviceable 3 Pole power contactor size FR4 with AC3 coil 300 Amp & AC1 400 Amp type ML 12 three phase 415 volt 50 HZ suitable for AMF panel, complete all as specified and directed. Make:- L&T model No. SS91010
132Taking down unserviceable Digital KWH meter 3x230V 3 phase, 3X-/5 Amp Cl-1 volt of size 96 Sqmm and FND display suitable from AMF panel, complete all as specified and directed. Make:- Asian model No. AM 3320.
133Taking down unserviceable Digital ammetre 0-5 Amps, 3 phase 415 volts of size 96 Sqmm suitable for AMF panel, complete all as specified and directed. Make:- Asian Model No. AM 2043
134S&F3 Pole power contactor size FR4 with AC3 coil 300 Amps & AC1 400 Amp type ML 12 three phase 415 volt 50 HZ suitable for AMF panel complete all as specified and directed. Make : L&T model No. SS91010
135S&FDigital KWH meter 3x230V 3 phase, 3X-/5 Amp, Cl-1 volt of size 96 Sqmm and FND display suitable for AMF panels, complete all as specified and directed. Make:- Asian model No. AM 3320.
136S&FDigital ammetre 0-5 Amps, 3 phase 415 volts of size 96 Sqmm suitable for AMF panels complete all as specified and directed. Make:- Asian Model No. AM 2043
137Contract Amount shall be derived after deducting the amount of Schedule of Credit in General summary on serial page No 17 of tender documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail