| 1 | M&L for attending the complaints of non functional and preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 litres of any make comprising of the following tasks at different locationswith technician team comprising one electrician and one helper toattend the complaint regularly. Technician team shallcollect the complaint from AGE E/M No. 1 office regularly and feed back of the complaint shallbe submitted on same day after rectification of complaint |
| 2 | Inspection of geyser after opening bottom cover plate. |
| 3 | Examine water tightness of storage tank. |
| 4 | Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts. |
| 5 | Replace washers and glands of defective taps to ensure water tightness smooth functioning. |
| 6 | Inspect vent pipes and remove blockage obstruction if any. |
| 7 | Check and correct earth continuity of electrical items. |
| 8 | Check and correct temperature setting of thermostats and test its functioning. |
| 9 | Checking and adjustments of pressure reducing valves. |
| 10 | Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole shall not be blocked / chocked. |
| 11 | Testing of Geysers after repairs/maintenance in all respect for proper functioning. |
| 12 | Taking down storage geyser of any capacityafter disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection for repairing and replacing the unservicealbe parts and assemble the same after making geysers serviceable, cleaning dust including connecting flexible 3 core cable as required, painting the geyser with white colour synthetic enamel paint by spraying and filling cavaties with filler including filling glass wool as heat resistance material ofrequired quantity etc and refixing the geyser in original location complete all as spcified and directed by Engineer-in-charge. Note: Spare parts as required for geyser shall be measured and paid separately under relevant items as \"Supply Only\" . |
| 13 | Supply only heating element push type 1.5 KW ISI Marked |
| 14 | Supply only heating element push type 2.0 KW ISI Marked |
| 15 | Supply onlyheating element triangle type 2.0 KW ISI Marked |
| 16 | Supply onlyheating element triangle type 1.5 KW ISI Marked |
| 17 | Supply onlyheating element thread type 1.5 KWwith ISI Mark |
| 18 | Supply onlyheating element thread type 2.0 KWwith ISI Mark |
| 19 | Supply only thermostat ISI marked suitable for the Geysers 25 / 50 litres capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or suitable size as per existing |
| 20 | Supply only thermostat ISI marked suitable for the Geysers 25/50 litres capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or suitable size, Set at 90+/-6 degree as per exsiting |
| 21 | Supply only PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per existing |
| 22 | SupplyonlyPVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 45 cm long for hot water as per existing |
| 23 | Supply only PVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for hot water as per existing |
| 24 | Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per existing. |
| 25 | Supply only indicators of Geysers of any capacity / type as per existing. |
| 26 | Supply only cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100 Volts grade complete all as specified. Make:Finolex/Havells/Policab |
| 27 | Supply and fix 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty.Make: Westen/Havells/Anchor |
| 28 | Supply only Geyser storage inner tank made out copper sheet suitable for 25 litres capacity |
| 29 | Supply only Geyser storage inner tank made out copper sheet suitable for 50 litres capacity |
| 30 | Supplyonly Apparatus plate copper of Geysers of any capacity/ type |
| 31 | Supply onlySafety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity . |
| 32 | S&F electric saving five /fFour star rated 2 KWpower water heater storage type (Geyser) of25 Litres capacity with all accessories complete including making water and electric connection all as required at site including provision of 04 Nos offashner nuts as required ofsuitable size, fixed in brick wall i complete all as specified and directed by Engineer-in- ChargeMake: Jaquar Model- Elena Verticalor other equivalent in Havells model- Bianca |
| 33 | Taking down electric water heater (geyser) of50 litres capacity from existing position disconnect allinlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of stainless steel tank and fixing in outer shell with proper filling of glass wool as heat resistance material, to required quantity, refixing the apparatus plate, geyser element, thermostat etc and also refixing the geyser in original location complete all as specified and directed. |
| 34 | Taking down electric water heater (geyser) of25 litres capacity from existing postion, disconnect allinlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of stainless steel tank and fixing in outer shell with proper filling of glass wool as heat resistance material, to required quantity, refixing the apparatus plate, geyser element, thermostat etc and also refixing the geyser in original location complete all as specified and directed. |
| 35 | M&L forattending the complaints of non functional and Preventive maintenance of solar water heating system/ Solar flat plate collector comprising of the following works at different locations of any make, complete all as specified and as directed. |
| 36 | Inspection of solar heating system and find out leakage in system |
| 37 | Examine water pipe line |
| 38 | Carrying out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts. |
| 39 | Replacingwashers and glands of defective taps to ensure water tightness and smooth functioning. |
| 40 | Inspect vent pipes and remove blockage obstruction if any. |
| 41 | Check and correct earth continuity of electrical items. |
| 42 | Check and correct temperature setting of thermostate and testing for proper functioning. |
| 43 | Checking and adjustments of pressure reducing valves. |
| 44 | Checking all electrical connection to ensure proper functioning. |
| 45 | Cleaning all glass plate |
| 46 | Testing of solar heating system after repairs/maintenance in all respect for proper functioning. |
| 47 | Repairing theunserviceable solar water heating systemand de-scaling with authorised agent and making serviceable by filling the Distilled water, cleaning the solar toughned glass, stopping the leackage by replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed.Note : (i) Spare parts of solar heating system shall be measured and paid separetaly under relevant item(ii) contractor shall submitt written warranty for matarials / spares provied by him for entire defacts laibility period. |
| 48 | Supply only Heating element as per existing including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 2000 watts and connected items all as specified and directed by Engineer-in- charge. |
| 49 | Supply only Heating element as per sample including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 3000 watts and connected items all as specified and directed by Engineer-in- charge. |
| 50 | Supply only distilled waterin sealed containers |
| 51 | Supply only Gl tubing medium grade 15mm bore with fitting and connected items all as specified Make:- Tata, Swastik, Jindal, Prakash, Surya. |
| 52 | Supply only Gl tubing medium grade 25mm bore with fitting and connected items all as specified Make:- Tata, Swastik, Jindal, Prakash, Surya. |
| 53 | Supply only GI coupling union 15 mm to 25 mm bore, ISI marked completeand connected items all as specified |
| 54 | Supply only Bib taps15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down,screwedfor iron pipe or for unions and connected items all as specified and directed. Make:- Plumber/Jaquar |
| 55 | Supply only Stop valves 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed Make:- Plumber/Jaquar |
| 56 | Supply only Stop valves 25 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed Make:- Plumber/Jaquar |
| 57 | S & F in repairs 16 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings andfixingworks andtestingofpipelinetestforsolventcement jointsandadhesivejoints and testing ofallmaterialsshall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282including making good the disturbed surfaces complete all as specified and directed. Make:- Finolex/Surya |
| 58 | S&F in repair 25 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings andfixingworks andtestingofpipelinetestforsolventcement jointsandadhesivejoints and testing ofallmaterialsshall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282including making good the disturbed surfaces complete all as specified and directed. Make: Finolex/Surya |
| 59 | S&F repairs float valves 15 mm with complete accessories all as specified and directed. Make:- Prayag or equivelent |
| 60 | S&F repairs float valves 25 mm with complete accessories all as specified and directed. Make:- Prayag or equivelent |
| 61 | S&Fin repairs MCB Single pole rated capacity 6 to 32 Amps, 240 volts breaking capacity 10 KA complete all as specified and directed.Make: ABB/L&T/SCHINDER |
| 62 | S&F in repairs MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA complete all as specified anddirected. Make: ABB/L&T/SCHINDER |
| 63 | S &Fin repairs MCB Four pole rated capacity 63 Amps, 240 volts breaking capacity 10 KA complete all as specified and as directed.Make: ABB/L&T/SCHINDER |
| 64 | S&F in repairs Sheet metal enclosure with earth plug andsocket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- Havell\"s or other equivalent in Legrand/Standard. |
| 65 | S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.Make:- Havell\"sor otherequivalent in Legrand/Standard. |
| 66 | S&F single core pvc insulated and sheathed cable with multistranded aluminium condutor ofsize 10 Sqmm Weather proof flat twin core cable for service connections from pole to Distribution board complete all as specified and directed Make:- HAVELL\"s / finolex/Policab |
| 67 | S&F sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm, LT. 1100 volts grade, drawn through and including 25 mm dia PVC non metallic conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor complete all as specified. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one unit lengh. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit. |
| 68 | M&L for Point wiringwith FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in wallsnot less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLSPVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 Amps socket point on independent board controlled by one switch including taking down exsiting point wiring complete all as specified. |
| 69 | S & F in replacement of 100 LPDPuf insulated stainless steel hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as persite requirement and directed by Engineer-in-charge. |
| 70 | S & F in replacement of 200 LPDPuf insulated stainless steel hot water storage tank for 200 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as persite requirement and directed by Engineer-in-charge. |
| 71 | S & F in replacement of 300 LPDPuf insulated stainless steel hot water storage tank for 300 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as persite requirement and directed by Engineer-in-charge. |
| 72 | M&L for maintenance and servicing of followingOT light fittings including control panel, suspension spring including all connected items and carring out routing check OT lights for smooth functioning all as per menufacturer instructions and entire satisfaction of Engineer-in-charge |
| 73 | OT-I as per existing |
| 74 | OT-II as per existing |
| 75 | OT-III as per exsiting |
| 76 | Notes: |
| 77 | Spares as requiredfor servicing shall be measured and paid saperately under relevant items |
| 78 | Servicing and replacement of spares shall be excuted throughAuthourised service provider as per manufacturer instruction. |
| 79 | Clean the light housing and arm by using mild soap and sterlized water mixture. Apply this mixture ona clean cloth and wipe down the light head and arm |
| 80 | Check front lens and optics to ensure there are no chips,cracks or other |
| 81 | Check to see that all mounting and attachement screws, washer etc for securely tightened. Replace any missing screw and retighten as required. |
| 82 | S&F in replacement of switching mode power supply and connected items all as specified and directed by Engineer-in- charge |
| 83 | S&F in replacement of reusable sterile handle and connected items all as specified and directed by Engineer-in- charge Make-:Philips |
| 84 | S&F in replacement of lower glass assembly and connected items all as specified and directed by Engineer-in- charge Make:- Philips |
| 85 | S&F in replacement of cabling and teflon wiring of 1.5 Sqmm to 2.5 Sqmm wiring complete and connected items all as specified and directed by Engineer-in- charge |
| 86 | S&F in replacement ofProjection Lamp for operation surgical lightType 7027 Cat Part No BRL/BCD AI/220of 12 V, 50 Watts50Hz frequenceand connected items all as specified and directed by Engineer-in- charge Make: Philips |
| 87 | S & F in replacement of Electronic Transformer Dimming by normal phase-cut dimmer short circuit and over voltageprotection. Working withMain supply 240 v, 50-60 Hz , Lamp power 50 w, Lamp voltage 12 v Ac. and connected items all as specified and directed by Engineer-in- charge Make:- Philips |
| 88 | S & F in replacement sensing card of online UPS 5KVAincluding cleaning, dusting and tightness of all electrical connection Make - Microtech all as specified and directed by Engineer-in- charge |
| 89 | S&F in replacement ofsheet metal enclosures single pole and neutral 4 way, 240 volt with 200 Amp rated bus bar for DBs (double door) , complete all as specified and directed Make:- Havells/Legrant |
| 90 | S&F in replacement ofsheet metal enclosures Triple pole and neutra 8 way, 240 volt with 200 Amp rated bus bar for DBs (double door) , complete all as specified and directed Make:- Havells/Legrant |
| 91 | S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) three layered hoisted and fixed in position of capacity 500 litres complete all as directed. Make:- Syntex Suprimo or equivent |
| 92 | S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) three layered hoisted and fixed in position of capacity1000 litres complete all as directed. Make:- Syntex Suprimo or equivent |
| 93 | Supply and laying on wall or fixing or passing through pipe in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm 2 Core, nominal cross section in service connections with DB. |
| 94 | S & F Mild steel section as in Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified & directed. |