| 1 | Tab. Amlodipine 5 mg. |
| 2 | Tab. Amlodipine10 mg. |
| 3 | Tab.Telmisartan 40 mg |
| 4 | Tab.Telmisartan 20 mg |
| 5 | Tab. Chlorthalidone 12.5 mg |
| 6 | Tab. Metformin 500 mg |
| 7 | Tab. Metformin 1000 mg |
| 8 | Tab. Glimeperide 1 mg |
| 9 | Tab. Glimeperide 2 mg |
| 10 | Tab. Aspirin75 mg |
| 11 | Tab. Metoprolol 25 mg |
| 12 | Tab. Metoprolol 50 mg |
| 13 | Tab. Atorvastatin 10 mg |
| 14 | Tab. Folic Acid |
| 15 | Tab.Bisacodyl Enteric IP 5 mg |
| 16 | Eardrop Forwax 10 ml ( Para Dichloro benzene 2% W/V) |
| 17 | Tab.Etoooylline +Theoylline( 150 mg SR) |
| 18 | Tab.Etoooylline +Theoylline( 300 mg SR) |
| 19 | Tab. Famotidine IP 20mg |
| 20 | Framycetin Sulphate (Cream) 30 gm |
| 21 | Gentamicine IP ( E/E Drops) 5 ml |
| 22 | Caps or Tabs.Griseofulvin IP 250 mg |
| 23 | Tab.Levothyroxine IP 25 MCG |
| 24 | Tab. Methycobalamin 1500MCG |
| 25 | Neomycin +Bacitracin Ointment 15 mg( 5 mg +500 IU/g) |
| 26 | Tab.Salbutamol Sulphate IP 2 mg |
| 27 | Salbutamol SulphateIP Inhaltion 200 MDI( 100 UG/dose) |
| 28 | Vitamin D3 ( Sachet)1 gm(60000 IU) |
| 29 | Calamine IP (Lotation) 100 ml |
| 30 | Sterilised Lancet(. Fine 30Gauge, Tri-Bevel Tip for virtually painless sampling. .Consistent Depth Penetration. .Universal Design Should Be Fit For Most Lancing Device. .Length - 1.2mm Width -0.32mm .Gamma Radiation Sterilized For Hygiene. |
| 31 | Glucometer. Assay Method- Electrochemistry.Coding- Auto Coding. No Coding For Easy To Use.Enzyme Compatibility - GDH-FAD.Test Time- 5 Seconds.Sample Volume- 0.5 ML.Sample Type- Whole-Blood, Capillary, Venous, Neonatal, Pregnant Women.Reference Type- Plasma Reference.Memory- 500 Test With Date & Time.Test Range- 10 To 600mg/dl.Power- 3V Battery CR 2032.Universal Check Strips- Should Be Available With Every Meter.Certification- USFDA, ISO15197:2013,EU- CE, ISO 13485:2016Customer Care And Service Engineer Availability Is Mandatory |
| 32 | Test Strips BGMSEnzyme- GDH-FAD.Manual Coding Requirement- No.Number of Strips Packed In Each Container- 50*2=100s Pack.Certification- USFDA, ISO15197:2015,EU- CE, ISO 13485:2016Electrode- Gold Layer.HCT Range- 0 To 70%.Strips Self Life Months – 24. After Opening Till Expiry Date (Print On Container).Availability Of Test Report From Central Gov/NABH/ILAC Accredited Lab or Institute.Control Solution Should Be Available For Sample Testing, Service (If Required) |
| 33 | Glucose Pouches Type: Glucose PowderWeight: 75 gm Packet per PoucheCertification must be ISO:9001 Certified |
| 34 | Swab. Type: Cotton with Sprit |
| 35 | Measuring JarType of Material : Polypropylene Capacity: 300 ML per jarCertification must be ISO:9001 Certified |
| 36 | HIV & Syphlis Dual Kit.Specimen Whole blood, Serum, PlasmaTest time 15 mins (Do not read after 20 mins)Specimen volume Whole blood: 20µl, Serum/Plasma: 10µlDetection of HIV Ab Sensitivity [95% CI] Total: 100.0% [99.4- 100.0\%) (637/637) Detection of HIV Ab Specificity [95% CI] Total; 99.9% [99.6-100% ](1,898/1,900) Detection of Treponema pallidum Ab Sensitivity [95% CI] Total:98.8% [97.1 - 99.596](395/400)Detection of Treponema pallidum Ab Specificity [95% CI] Total:100.0% [ 99.8 * 100 \%](1,900/1,900)Storage temperature 2-40°C/36-104°F |