| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-09-2023 | Technical Bid | Technical Bid | 08-09-2023 |
| Sl. No. | Item Description |
| 1 | Note : - The Contractor shall quote his/their rates without GST, GST will be paid extra by the Department as per prevelling rates at the time of payment. |
| 2 | Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | Supplying chemical emulsion in sealed containers including delivery asspecified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 (1 cement :4 course sand (zone-II): 8 graded stone aggregate 40 mm nominal size) |
| 7 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 course sand : 6 graded stone aggregate 20mm nominal size ) over 75 mm bed dry brick ballast 40mm nominal size ,well rammed and consolidated and grouted with fine sand including necessary excavation levelling and dressing & finishing the top smooth. |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). All work upto plinth level. |
| 9 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix).All works above plinth level up to floor IV level |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect for all heights/depths/storeys/basements etc.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 19 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 20 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade ,Area of slab over 0.50 sqm |
| 21 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 23 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 24 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm |
| 25 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 150x10 |
| 26 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 27 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 28 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing beadof appropriate dimension. (Area of door up to 2.00 sqm). |
| 29 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon ollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of ater etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels)made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). |
| 30 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
| 31 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1 Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 32 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 33 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound ( Unicrete make)mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 34 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 35 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete. |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600mm |
| 37 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 38 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 39 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 40 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 41 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 42 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 43 | Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete |
| 44 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.Two or more coat on new work |
| 45 | Designing, fabricating, testing, protection, installing and fixing inposition semi (grid) unitized system of structural glazing (with openjoints) for linear as well as curvilinear portions of the building for allheights and all levels, including: (a) Structural analysis & design and preparation of shop drawings forthe specified design loads conforming to IS 875 part III (the systemmust passed the proof test at 1.5 times design wind pressure withoutany failure), including functional design of the aluminium sections forfixing glazing panels of various thicknesses, aluminium cleats, sleevesand splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop(barrier)-cum-smoke seals, microwave cured EPDM gaskets for watertightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sections andprofiles etc. to accommodate 3 Dimensional movement for achievingperfect verticality and fixing structural glazing system rigidly to theRCC/ masonry/structural steel framework of building structure usingstainless steel anchor fasteners/ bolts, nylon separator to preventbimetallic contacts with nuts and washers etc. of stainless steelgrade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealantand one part weather silicone sealant compatible with the structuralsilicone sealant of required bite size in a clean and controlled factory/ work shop environment, including double sided spacer tape, settingblocks and backer rod, all of approved grade, brand and manufacture,as per the approved sealant design, within and all around theperimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet1 mm thick and of sizes, shapes and profiles, as required as per thesite conditions, to seal the gap between the building structure andall its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters thecurtain glazing system to make it watertight, by incorporatingprinciples of pressure equalization, providing suitable gutter profilesat bottom (if required), making necessary holes of required sizesand of required numbers etc. complete. This item includes cost of allinputs of designing, labour for fabricating and installation of aluminiumgrid, installation of glazed units, T&P, scaffolding and other incidentalcharges including wastages etc., enabling temporary structures andservices, cranes or cradles etc. as described above and as specified.The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer,dully approved by Engineer-in-charge. The item also includes thecost of all mock ups at site, cost of all samples of the individualcomponents for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning andprotection till the handing over of the building for occupation. In theend, the Contractor shall provide a water tight structural glazing havingall the performance characteristics etc. all complete as required, asper the Architectural drawings, as per item description, as specified,as per the approved shop drawings and as directed by the Engineer-in-Charge. also SS metal cut latter Sport Complex Notes for Item 29.6: 1. The cost of providing extruded aluminium frames, shadowboxes, extruded aluminium section capping for fixing in the groovesof the curtain glazing and vermin proof stainless steel wire meshshall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area ofstructural glazing (including width of grooves) on the external faceshall be measured in sqm up to two decimal places 2. The following performance test are to be conducted onstructural glazing system if area of structural glazing exceeds 2500sqm from the certified laboratories accreditated by NABL(NationalAccreditation Board for Testing and Calibration Laboratories),Department of Science & Technologies, India. Cost of testing ispayable separately. |
| 46 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 47 | Art work :- Supply and laying of below mentioned items,Perparation of plaster surface by Emery paper Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm Making the art work as giver drawings and specification with required finishing as per entire satisfication of Engineer-incharge including labour,sacfolding, paint and all other materials and machinary required for complete the jobs upto 10 Metre height |
| 48 | Hard Plaster Description:- Supply and Application of Hard Plaster System meeting specifications for SquashCourt laid down the The system consists of a 10mm base coat with silica sand and a top coat of 2-3mm, which makes it a total thickness of 12mm - 13mm. Due to extremely hard nature of plaster, a slight uneven color distribution may be seen once the plaster has dried, this doesn\"t affect the strength or integrity of the plaster and must not be considered as a defect. Area Wall plaster playing area is only below red lines totaling to approximately 1065 SqFt. |
| 49 | Suppling and installation of free standing Squash coart Glass back wall made 12 mm thick toughened glass with 4 panels ,1 door ,4 fins, fixtures and all materials required for erecting of the glass wall, The height of the glass wall be 2130 mm above the finish floor level, wall openning - wall opening require 6400 mm clear opening between two side of the wall for installation of the glass, It require a niche in each side of wall and concrete sub floor outside of the court area. |
| 50 | Sound Board - Providing & fixing of Sound Board for Squash CourtDescription:- (7 feet x 17 inch) x 3 Nos; Tin board of 22 gauge |
| 51 | Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 6 mm thick toughened clear glass. |
| 52 | Supply and fixing of 12 mm toughned glass with automatic sliding door with patch fitting and all types of hole connector and electrical connection for complete the work as per satisfication of Engineer- in-charge. Size23.5x 9.5ft. |
| 53 | Waterproofing Treatment of Sunken PortionsProviding, & Laying water proofing treatment of RCC sunken slabs (toilets,kitchens etc.) to vertical and horizontal surfaces as per the following operations.(Actual area of work done will be measured and paid) Cleaning of RCC surfaces and brick walls with brush, followed by repairing of mother surface / horizontal and vertical joints / any type of Khurass / core in thesurface with cementitious Unicrete Ready Mix screed or Unicrete Grout Fix compound (as per suitable usage) mixed with Unicrete admixture. Course 1 - Providing and applying of primer coat on the prepared surface using Unicrete Latex 705 (with 50% water dilution in Latex 705) Course 2 - Providing & Applying of 2nd coat of flexible 2 component cementitious waterproofing membrane Unicrete Smart flex 815 over Course 1 after an interval of 4 - 6 hours or complete drying of Course 1.Course 3 - Providing & Applying of 3rd coat of flexible 2 component cementitious waterproofing membrane Unicrete Smart Flex 815 over Course 2 after an interval of 6 -8 hours or complete drying of Course 2. Followed by curing of course 3 up to 3 days by means sprinkling of water. |
| 54 | Protection Layer of Sunken waterproofingProviding & Laying of 12 - 15 mm Unicrete Ready Mix Screed mixed with Unicrete Latex 705 of 100 ml dosage per 40 kg bag of premixed screed (having compressing strength of > 6 N/mm2 @ 28 days) followed by curing of 7 days with water. |
| 55 | Providing and laying of Terrace WaterProofing for .Specification Details Providing and applying roller applied, solvent free, Unicrete Membryl flex PU – 100 one component (ASTM C 836), Polyurethane highly permanent elastic ,solvent free, cold applied and cold cured system which includes non-tar extended, standard 100% solids highly elastic, for high crack spanning capability with Root Resistant properties.The total system must be a tough durable film, highly resistant to mechanical damage and totally impervious to water immersion with an average dry film thickness DFT of 1.0 mm after application of a PU Based primer on the prepared surface The waterproofing membrane or system must be applied in minimum 2 coats after application of PU based primer. Application ProcedureStrictly follow manufacturer\"s application instructions and provide a copy in advance to Engineer In-charge to ensure compliance. Application will involve cleaning surface thoroughly with appropriate means. The surface needs to be clean, dry and sound, free of any contamination, which may harmfully affect the adhesion of the membrane. Use pre-measured packaging as far as possible. (Detailed Steps as below mentioned).Surface CleaningCleaning the RCC surface and parapet walls thoroughly to make surface free from contaminants like dirt, old loose coatings and laitance & to remove the loose materials by various mechanical means like cleaning with wire brush followed by air blowing the surface with Air Pressure Jet Machine. Substrate compressive strength should be at least 25 Mpa and bond strength of at least 1.5 Mpa. New structures need to be dry for at least 28 days. Max moisture content should not exceed 5 %.Surface PreparationRepairing of mother surface including removal of imperfections protrusions, loose concrete & filling of cracks / horizontal and vertical joints / any type of Khurass / core in the surface.using Polymer Modified Mortar prepared as the Cement :Sand ratio of 1:4 and admixed @ 5 % Unicrete Latex 705 polymer by weight of cement. Sealing at Junction of Vertical & Horizontal SurfaceProviding and making Corner fillets or coving along the Junction of Horizontal and Vertical surface using Polymer Modified Mortar prepared as the Cement :Sand ratio of 1:4 and admixed @ 5 % Unicrete Latex 705 polymer by weight of cement. Sealer Priming Coat Providing, mixing and applying 1 coat of Unicrete PU base Primer to the mother slab and parapet walls up to minimum height 300 mm or above the soil filling height whichever is higher . Waterproof Coating on Vertical & Horizontal Concrete Surface Providing & applying waterproofing treatment to the primed surface for water barrier in 2 coats to achieve a nominal total DFT of 1.0 mm as per below mentioned procedure a) Applying 1st coat of 1 Component Unicrete Membryl Flex PU -100 liquid membrane coating (Solids 100 %) to achieve a nominal DFT 0.5 mm b) Applying 2nd coat of 1 Component Unicrete Membryl Flex PU -100 liquid membrane coating (Solids 100 %) to achieve a nominal DFT 0.5 mm |
| 56 | Protection Layer & PCC1:2:4 screed for slope of Terrace Waterproofing Providing & Laying of average 100 mm thick PCC 1:2:4 screed for creating slopes towards the drain in the ratio of 1:10 admixed with integral waterproofing compound @ 200 ml per bag of cement and reinforced with Polypropylene (PP) Fiber or welded wire mesh for crack prevention followed by curing of 7 days with water as per drawings provided by architect or Engineer in Charge. |
| 57 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia |
| 58 | 1 :2 :4 ( 1 Cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) |
| 59 | 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) |
| 60 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :100 mm dia |
| 61 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 62 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 63 | Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 64 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 65 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia |
| 66 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 67 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 68 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 69 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 70 | Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Note:- Pipes and fittings with \"Flow Gaurd\" technology as per CTS Standard dimensional ratio (SDR) :11 (Class 1) Pipes at a working pressure of 27.6 Kg / sq.cm at 23 degree celsius using moulded Chlorinated Polyvinyl Chloride (CPVC) fittings i.e. Tees, Elbows, Couplers, Unions, Reducers , etc. incl transitions fittings connection between CPVC and Metal Pipes / GI Pipes with Brasss adaptors (both Male & Femal End) Confirming to ASTM D 2846 with only CPVC solvent cement Confirming to ASTM F-493. 20mm |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Note:- Pipes and fittings with \"Flow Gaurd\" technology as per CTS Standard dimensional ratio (SDR) :11 (Class 1) Pipes at a working pressure of 27.6 Kg / sq.cm at 23 degree celsius using moulded Chlorinated Polyvinyl Chloride (CPVC) fittings i.e. Tees, Elbows, Couplers, Unions, Reducers , etc. incl transitions fittings connection between CPVC and Metal Pipes / GI Pipes with Brasss adaptors (both Male & Femal End) Confirming to ASTM D 2846 with only CPVC solvent cement Confirming to ASTM F-493.25 mm |
| 73 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20mm nominal |
| 74 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal |
| 75 | Providing and fixing Unplasticised PVC connection pipe with brass unions:45 cm length 15 mm nominal bore |
| 76 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 77 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
| 78 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 79 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 80 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge |
| 81 | Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology.15 mm nominal bore |
| 82 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 |
| 83 | Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover each 3905 3905 and frame light duty single seal weighing 20 kg with C.C. Topping |
| 84 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 85 | Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 .Including the cost of carriage and all fixing labouras per entire staisfication of Engineer incharge Door bend 87.5 Degree 110MM (N.S ITEM) |
| 86 | Plain bend 110MM |
| 87 | PlainTees110MM |
| 88 | P-Trap 110 mm x 110mm |
| 89 | Gully Trap 150mmx150mmx110mm |
| 90 | Providing and Fixing floor drain with jali (S.S) |
| 91 | Providing & fixing under counter rectangular basin of size 160x490x375mm (model no.CNS-WHT-WB01) of jaguar, parryware, hindware or equivalent make. with all accessories complete with all respects (N.S ITEM) |
| 92 | Providing and fixing Baloon/chilly Clamp2 to 2.5mmpati thickness with 8mm dia bullet fastner, 8mm tie rod witth Nut and washer for pipe hanging 25mm Dia |
| 93 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B, 160mm old SWR UPVC pipe lines laid complete |
| 94 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B, 110mm old SWR UPVC pipe lines laid complete |
| 95 | Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe Group B |
| 96 | Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe |
| 97 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 98 | Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 99 | Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 100 | Supply and erection of MS conduit pipe 1.6mm thickISI marked (Medium) recessed in wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.MS pipe of 20mm dia. |
| 101 | Supply and erection of MS conduit pipe 1.6mm thickISI marked (Medium) recessed in wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.MSpipe of 25mm dia |
| 102 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (LAN+DATA+WIFI+TELEPHONE+CCTV) PVC pipe of 20mm dia. |
| 103 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (LAN+DATA+WIFI+TELEPHONE+CCTV) PVC pipe of 25mm dia |
| 104 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15/16 amp switch |
| 105 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 6 pin 15/16 amp socket outlet |
| 106 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push |
| 107 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 108 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 109 | S/E of fittings and accessoriesCall bell buzzer 220/230 volts A.C. bakelite with double coil |
| 110 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.1 & 2 Modules |
| 111 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single pole |
| 112 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole and neutral |
| 113 | Supplying and fixing Cable End Box (Loose Wire Box) suitable forfollowing triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required For 4 way, Double door TPN MCBDB |
| 114 | Supply and erection of hexagonal M.S. box 1.60mm thick having each side 8cms, 7.5cms deep, top covered with M.S. lid by means of screws including 10mm dia 30cm long mild steel rod made into suitable suspension hook and erected in R.C.C. slab for erection of fan, the bottom covered with 3mm thick bakelite sheet with suitable holes, painting etc. compelte with all labour and material required to complete the job |
| 115 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 116 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonryenclosureswith cover plate having locking arrangement and watering pipeof 2.7 metre long etc etc. with charcoal/ coke and salt as required. |
| 117 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 118 | Pdg. and fixing 25 mm x 5 mmcopperstrip on surface or in recess for connections etc.as required with all labour and material. |
| 119 | Pdg. and fixing 4.00 mm dia copper .wire on surface or in recess for loop earthing as required . |
| 120 | Supply erection testing and commissioning of Recess / Surface mounted 2\" x 2\" panel 36 WATT ( +_ 2 watt ) LED Efficacy 120 Lm/w. Luminaireincluding petty materials required to complete the job in all respect.WIPRO Make , Model :- CRCO10R038HP57GL1 or Equivalent inilips / Trilux as approved by the Engineer-in-charge.Warranty 2 years from the Date of invoice. |
| 121 | Supply of <=20 watt LED Tube Light rod, 4\" long suitable for rated voltage 220-240V AC working range:- 140-270 V A\"c , 50 Hz +_ 5%, AC supply with aluminium alloy base, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -20° C to 45° C, Lumen output for LED tube should be > 2200 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED >80%with correlated colour temperature (CCT) of 6500minimum burning hour life >40000 hours,LED viewing angle 120 Degree , Make of LED-OSRAM / Samsung/Cree/Nichia complete in all respect with the entire satisfaction of the Engineer-in-incharge. (Make of tube fitting: Philips/Osram/Havells/GE/Wipro/Crompton Greaves). Supply of Industrial General Purpose 4\" long tube fitting suitable to house 1x18w LED tube rod 4\" long, CRCA steel sheet fabricated housing duly epoxy powder coated in finish & having G13 push fit type lamp holder, rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. (Make: Philips/Osram/Havells/GE/Wipro/Crompton Greaves) |
| 122 | Supply and erection ofunder ground cable loose inexisting pipe or trenchescomplete with necessary connections.16 sq mm 4 Core cable (Armoured) |
| 123 | Supply,erection,testing of ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 56\" (1400 mm) (Make: Orient/ Hevells/ GEC). |
| 124 | Supply,erection,testing of exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with GI sheet ducting in structure confirming to latest IS specification complete in all respect to satisfaction of Engineer-in-charge. (Make: Orient/ Hevells/ GEC). |
| 125 | Supply and erection of <=50W LED lamplight having following specification1504 mm long IP voltage –AC 230V, total power consumption – 50 W (i/c driver), Lamp Luminous efficiency - >207 lm/W, Lumens - >10350 lm, Colour-cool white, CCT - 5000K, CRI-more than 70, operating tempracture = -35°C to + 50°C, IP rating luminiare - IP65, IP rating LED module - IP54, power factor = =0.95. Complete in all respect with the entire satisfaction of Engineer-in-Charge. (Make: Axion). |
| 126 | Supply and Fixing of Carbon Standard Fire Man Axe with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. |
| 127 | Supply and fixing of 6kg ABC type fire extinguisher as per IS:15683(6 kg.) with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.Make: CEASEFIRE/MINIMAX/Safeguard/FYRMAX/LIFE GUARD |
| 128 | Supply and fixing of 4.5kg C02 gas type fire extinguishe as per IS: 15683(4.5 kg.) with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.Make : CEASEFIRE/MINIMAX/SAFEGUARD/FYRMAX |
| 129 | Providing and Fixing of MS angle iron frame duly painted, of standard height suitable to hold 3 buckets at a time and Gl Filled sand Buckets painted RED complete with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. |
| 130 | Providing Elelctric Shock Treatment Chart of standard size duly framed and covered with 5 mm thick glass etc. complete In all respectsincluding the cost of all petty material required to complete the job upto entire specifications of Engineer-in – charge. |
| 131 | Supply and M.S. pipe (B-class) for suspensionrod of ceiling fan including threading ifrequired. (a) 15mm dia |
| 132 | Supply Installation testing & commissioning of Passenger (680 Kg, 10 persons.)Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty/maintenance period from the date of completion to be supplied and installed in accordancewith the following technical specifications:Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI Description Specification (A)-Schindler 3000 mode01) Designation of Lifts Passenger 02) No. Of Elevators as shown in quantity coloum. 03) Type and Capacity 10 Passenger – 680 Kgs 04) Speed 1 M/Sec 05) Drive power -4.6 Kw 06) Location of M/c Room Not Required 07) Travel 14.5 m approx. 08) Serving , 0, 1,2,3. 09) No. Of Stops 4 10) Well Size Available (WxD)1950 mmx 1675 mm11) Power Supply 415 V Three Phase 50 Cycles Ac\ 12) Auxiliary Single Phase 220v 50 Cycles Ac 13) Car size 1200 mm (W) X 1400 mm (D) X 2239 mm {H} 14) Pit Depth 1400 mm 15) Head Room 4200 mm 16) Clear car height HKC-2200 mm17) Car door 900 mm x 2000 mm, car door type- Door centre opening 2 panels. 18) Landing door fire protection classification -EN 81-58 E120 (120 mints fire rated). 19) Counter weight location -left side20)Car access sides-1 (21) Main Stop-1 (22) Door drive- Femator campact.(23) Drive and control- Full collective control -simplex.(24) Controller position - In right door jamb (LDU)(25)Controller location- Landing at floor 3 on side 1.(26) Main connection- TN-S (3L+PE+N)(27) Main power supply- 415V 50HZ(28) light power supply- 230V(29) Number of trip per hour -120(30) Communication option selected- Intercom TAI; 3ways,remote monitoring alarm by horn in hoistway.(31) Control option selected- Auto door closing final time, Position indicator car 1 travel direction indicator car auto,rescue device (ARD) Fire emergency switch.(32) Decoration line - Times square, Ceiling type- Round spot SS AISI441 hairline, car door- SS cladd 441 hairline, side wall -SS cladd 441 hairline, Rear wall-SS cladd 441 hairline, Floor -Artificial granite Black, Skerting Alignment- protruding Al painted , Car Panels SS Hairline Finish Panels. |