Tender For Provision Of Mechanical Laundry In Klp Under Ge (North) Ambala Cantt, ambala-Haryana

Military Engineer Services-MES has published Tender For Provision Of Mechanical Laundry In Klp Under Ge (North) Ambala Cantt. Submission Date for this Tender is 20-09-2023. Housekeeping Equipments Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

39309601
Corrigendum : Tender For Provision Of Mechanical Laundry In Klp Under Ge (North) Ambala Cantt
Open Tender
Indian
Haryana
ambala
20-09-2023

Tender Details

Tender For Provision Of Mechanical Laundry In Klp Under Ge ( North ) Ambala Cantt ; 1 Supply, Install, Testing And Commissioning Front Loading Commercial Washing Machine With In Built Hydro Extractor Of Capacity 30 Kg ( Per Charge ) , Operating On 415 V, 3 Phase, 50 Hz Ac Supply. Washing Machine Shall Have Inner Basket & Outer Drum Fabricated Out Of High Quality 304 Grade Stainless Steel, Fully Automatic Control Panel Provided With Plc For Automatic Forwarding And Reversing Digital Timer & Temperature Controller. Washing Machine Shall Have Provision For Driven By Triangular Belt For Best Efficiency, Simple Operation With Start Stop Button And Led Display Light. All Stainless Steel Parts Of Washing Machine Shall Be Polished In Glossy Finish Andall Mild Steel Parts Are Painted With Epoxy Paint And Have Three Coats Of Epoxy Primer Layer For Long Lasting And Heavy Duty Operation. Technical Specification Are As Follows :- ( A ) Basket Size - 900 Mm Dia X 500 Mm Depth. ( B ) Vol Of Inner Basket - 318 Ltrs ( C ) Operation Cycle - 30-40 Min. ( D ) Opening Door Size - 500 Mm Dia. ( E ) Wash Motor - 3.75 Kw ( 5Hp ) Make Of Motor - Abb / Siemens / Schneider. ( F ) Drive - Variable Frequency Drive , 5 Hp Make Of Drive - Crompton / Schneider / Inovanse ( G ) Wash Speed - 40-50 Rpm ( Approx ) ( H ) Extract Speed - 200 Rpm ( J ) Electric Heating Load - Water Immersion Heater 12 Kw Make - Neel / Dovy ( K ) Water Consumption - 300 Ltrs / Cycle 2 Item No. 01 ( Contd.... ) ( L ) Water Inlet - 25Mm Bsp Having Solenoid Valve ( M ) Drain - 65 Mm Bsp With Motorised Drain Valve ( N ) Door - S. S Sheet Fitted With Toughened Glass ( O ) Make Of Belt - Ecodrive / Hindon / Alaska / Isi ( P ) Make Of Bearing - Arb / Nbc / Skf / Urb ( Q ) Thickness Of Ss Inner Basket - 1.5 Mm To 1.6 Mm Ss 304 Grade Sheet To Be Punched & Die Sunk And Duly Buffed & Polished. ( R ) Thickness Of Ss Outer Drum - 1.5 Mm To 1.6 Mm Stainless Steel 304 Grade ( S ) Thickness Of Ss Sheet Front - 1.5 Mm To 1.6 Mm Thick Ss 304 Grade And Duly Buffed & Polished. ( T ) Main Body - Made Out Of Mild Steel Plate And Channel Base Frame. ( U ) Overall Dimension - 1050Mm ( W ) X 1200 Mm ( D ) X 1640 Mm ( H ) . ( V ) Electrical Control Box - Consisting Of L&T / Schneider / Siemens.Make : As Approved By E-In-C Branch 3 Supply, Install, Testing And Commissioning Drying Tumbler Machine Capacity 30 Kg ( Per Charge ) Operating On 415 V, 3 Phase, 50 Hz Ac Supply Shall Be Front Loading Type With Electric Heated And Including Inner Basket Made Of High Quality 304 Grade Stainless Steel, Double Wall & Glass Wool Insulated. Outer Body Shall Be Made Of Mild Steel, Plc For Automatic Forwarding And Reversing Digital Timer & Temperature Controller. All Stainless Steel Parts Of Drying Tumbler Machine Shall Be Polished In Glossy Finish And All Mild Steel Parts Are Painted With Epoxy Paint And Have Three Coats Of Epoxy Primer Layer For Long Lasting And Heavy Duty Operation Including State Of Art Control Panel And Electric Motor Of Suitable Hp With Starter. Technical Specification Are As Follows :- ( A ) Loading Capacity - 30 Kg ( B ) Operation Cycle - 40-60 Min. ( C ) Inner Basket Size - 950Mm Dia X 850 Mm Depth ( D ) Vol. Of Inner Basket - 602 Ltrs ( E ) Basket Speed - 36-40 Rpm ( F ) Opening Door Size - 650 Mm Dia Approx ( G ) Drive Motor - 0.75Kw 1 ( Hp ) , 415V, 3 Ph, 50 Hz Ac Supply Make - Abb / Schneider / Seimens ( H ) Blower Motor - 0.75Kw 1 ( Hp ) , 415V, 3 Ph, 50 Hz Ac Supply Make - Abb / Schneider / Seimens ( J ) Loading Door - Made From Mild Steel Fitted With Toughened Glass. ( K ) Electric Heating Load - Fin Type Air Heating Element 18 Kw Make - Neel / Dovy. ( L ) Waste Air Exhaust - 210 X 210 Mm 4 Item No. 03 ( Contd.... ) ( M ) Make Of Belt - Ecodrive / Alaska / Isi ( N ) Make Of Bearing - Arb / Nbc / Skf / Urb ( O ) Insulation - Glass Wool ( P ) Lint Screen - Manual Cleaning Lint Screen Of Ss For Easy Maintenance. ( Q ) Suction Blower - Heavy Duty Aluminium Cast Suction Blower Driven By Independent Blower. ( R ) Thickness Of Ss Inner Basket - 1Mm Ss Perforated Sheet Fitted With Back & Front Plate 1.5 Mm To 1.6 Mm Ss Sheet 304 Grade Duly Buffed And Polished. ( S ) Outer Body Front, Back & Side - Made Of 1.2 Mm To 1.6 Mm Ms Sheet ( T ) Overall Dimension - 1050 Mm W X 1500Mm ( D ) X 1980Mm ( H ) ( U ) Electrical Control Box - L&T / Schneider / Seimensmake : As Approved By E-In-C Branchnote Item No. 1 & 2 :- ( A ) Quoted Rates Including Necessary Pcc Foundation As Recommended By Oem. ( B ) Rates Including Complete Installtion Electrically And Mechanically And Testing In Front Of Engr-In-Charge And Accepting Officer. ( C ) Rates Includes Complete One Year Warrenty After Installation Of Machines Including Replacement Of Defective Parts And Comprehensive Maintenance For One Year By Oem. ( D ) Rates Includes One Week Teaching Operation Of Machines To User Rep. ( E ) Water Connection Is Available Upto The Wall And Contractor Should Take A Connection From Wall To Machines With Gate Valve And Stainer. 5 S&F Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket 20 Amp Complete With And Including One Single Pole Mcb.20 Amp, 10 Ka C Curvecomplete All As Specified And As Directed By The Engr-In-Charge. 6 S & Layingas In Repairsub Main Wiring With Two Run Of 16 Sqmm Pvc Insulated , Unsheathed Cable Frls-H, 1100 Volts Grade Isi Marked With Multi Stranded Copper Conductor And One Run Of 16 Sqmm Pvc Insulated , Unsheathed Cable Frls-H, 1100 Volt Grade Isi Markedmulti Stranded Copper Conductor As Earth Continuty Conductor Connected To Common Earth Dolly Including Concealed On Wall / Ceiling Surfaces In Pvc Conduit Medium Gradeisi Marked Of Adequate Size For Housing The Wirescomplete All As Specified. Note: ( I ) Thimble / Lugs Of Rating Of Mcb Should Be Used With Wire For Fixing In The Mcb. ( Ii ) Three Runs Of Cable And One Run Of Pvc Conduit Shall Be Measured And Paid As One Unit Length. 7 Material & Labourearthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25M Deep Below The Ground Level ) With Top Edge Of The Plate Not Less Than 1.5Mtr Below The Normal Ground Level Connected To Galvanised Iron Stripearth Lead Of 25X 4Mm Thick Size By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron, Earth Strip Protected By Gi Pipe 32Mm Bore ( Medium Grade ) And Connected To Main Switch Board Or Main Control Board As Directed And As Specified And Shown In Electrical Plate No. 3 Of Ssr Part I ( 2009 ) Including Necessary Concrete Pit In Pcc ( 1:3:6 ) Type C1, Pre-Cast Rcc ( 1:2:4 ) Type B1 Cover Slab 40 Cm X 40Cm X 5Cm Reinforced With 8Mm Dia Tmt Bars @ 15Cm C / C With One Handle For Liftingmade Out Of 8Mm Dia Bar, Funnel, Wire Mesh, 20Mm Dia Gi Pipe Medium Grade For Watering, Charcoal Or Coke And Salt In Alternate Layers Including Necessary Excavation And Earth Work In Any Type Of Soil And Testing Complete All As Directed By Engineer-In-Charge And Earth Testing On Completion .Note :-Cost Of Gi Strip 25X4 Mm Thick Upto 7.5 Mtr Length Shall Be Includied In The Quoted Rate. 8 Supply And Fixing Sheet Metal Enclosurevertical Triple Pole & Neutral ( Vtpn ) , 415 Volts, 4 Way With 200 Amp Rated Bus Bar, Ip 54 Protection, Double Door, With And Including Mccb 4 Pole, 200 Amp, 415 Volts, Breaking Capacity 25 Ka , Adjustable Thermal Rangeas Incomer, Flush / Surface Mountingduly Grouted In Wall Or On Wooden Board With Lugs / Thimbles Duly Crimped For Connection Complete All As Specified And As Directed By The Engr-In-Charge. Make : L&T / Schneider / Seimens 9 Supply And Fixingmccb 4 Pole, 415 Volt, Fixed Type 125 Amps Suitable For Vtpn Db With Breaking Capacity 16Ka Complete All As Specified And Directed.Make : L&T / Schneider / Seimens 10 Supply And Laying Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Cable 50 Sqmmcross Sectional Area, 3.5 Corewith Aluminium Conductor, 1100 Volts Gradecomplete All As Specified And As Directedby Engineer-In-Charge. 11 Excavating In Trenches, Not Exceeding 1.50 Metre Wide And Not Exceeding 1.50M In Depth For Foundation Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes Etc. Not Exceeding 10 Sq.M On Plan And Not Exceeding 1.50M In Depth And Getting Out In Soft / Loose Soil, Complete All As Specified And As Directed . 12 Supply And Lay Gi Tubing Light Grade Withconnected Fittings 32Mm Dia For Cable Protection And Fixed With Clamp To Pole And Wall With Nut Bolts Complete All As Specified And As Directedby Engineer-In-Charge 13 Material And Labour For Fine And Dry Sand Cushioning For Underground Cable By Providing A Layers Of Sand 8Cm Deep Before Laying And 15Cm Deep After Laying The Cable Including Stretching The Cable, Complete All As Specified And As Directed . Note - Punned Thickness Of Sand Layer Shall Be Measured And Paid To Contractor. 14 Supply And Laying Well Burnt Brick Class-B Laid Flat To Cover The Cable Width Equal To The Length Of Cable And Abutting Each Other For Protection Of Cablecomplete All As Specified And As Directedby Engineer-In-Charge. 15 Returning, Filling In, Including Spreading, Levelling , Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Complete All As Specified And As Directed By The Engineer-In-Charge. 16 Removing Surplus Excavated Materialto A Distance N.Exc 50M And Depositing Where Directed At A Level N.Exc 1.5M Above The Starting Point Complete All As Specified And As Directed By The Engineer-In-Charge. 17 M& L For Cutting The Existing Hard Standing / Pcc / Wbm Roaddepth Exceeding 45 Cm And 30 Cm In Widthfor Passing Of Cable Through Gi Pipe And Making Good The Disturbed Surface With Pcc ( 1:3:6 ) Type C-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed. 18 Supply And Fixingmcb, 100 Amps, Tpn, 415V, 10 Ka, C Curve Including Testing And Commissioning Complete All As Specified And As Directed By The Engineer-In-Charge.Make : L&T / Schneider / Seimens.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Aug-2023 Amd boq BOQ 13-09-2023
2 13-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work: Provn of mechanical laundry in KLP under AGE E/M(N) Ambala Cantt
Sl. No. Item Description
1Supply, install, testing and commissioning Front loading Commercial washing machine with in built Hydro extractor of Capacity 30 Kg (Per Charge), operating on 415 V, 3 phase, 50 Hz Ac supply. Washing machine shall have Inner basket & outer drum fabricated out of high quality 304 grade stainless steel, fully automatic control panel provided with PLC for automatic forwarding and reversing digital timer & temperature controller. Washing machine shall have provision for driven by triangular belt for best efficiency, simple operation with start stop button and LED display light. All stainless steel parts of washing machine shall be polished in glossy finish andall mild steel parts are painted with epoxy paint and have three coats of epoxy primer layer for long lasting and heavy duty operation. Technical specification are as follows :- (a) Basket Size - 900 mm dia x 500 mm depth. (b) Vol of Inner Basket - 318 Ltrs (c) Operation Cycle - 30-40 min. (d) Opening door Size - 500 mm dia. (e) Wash Motor - 3.75 kW (5HP) Make of Motor - ABB/Siemens/Schneider. (f) Drive - Variable Frequency Drive , 5 HP Make of Drive - Crompton/Schneider/Inovanse (g) Wash Speed - 40-50 RPM (Approx) (h) Extract speed - 200 RPM (j) Electric Heating load - Water Immersion heater 12 kW Make - Neel/Dovy (k) Water Consumption - 300 Ltrs/Cycle
2item No. 01 (contd....) (l) Water Inlet - 25mm BSP having Solenoid Valve (m) Drain - 65 mm BSP with Motorised Drain Valve (n) Door - S. S sheet fitted with toughened Glass (o) Make of Belt - Ecodrive/Hindon/Alaska/ISI (p) Make of bearing - ARB/NBC/SKF/URB (q) Thickness of SS Inner Basket - 1.5 mm to 1.6 mm SS 304 grade sheet to be punched & die sunk and duly buffed & polished. (r) Thickness of SS Outer Drum - 1.5 mm to 1.6 mm Stainless steel 304 grade (s) Thickness of SS Sheet Front - 1.5 mm to 1.6 mm thick SS 304 grade and duly buffed & polished. (t) Main body - Made out of Mild steel plate and Channel base frame. (u) Overall Dimension - 1050mm (W) x 1200 mm (D) x 1640 mm (H). (v) Electrical Control Box - Consisting of L&T/Schneider/Siemens. Make : As approved by E-in-C Branch
3Supply, install, testing and commissioning Drying Tumbler Machine Capacity 30 Kg (Per Charge) operating on 415 V, 3 phase, 50 Hz AC supply shall be front loading type with electric heated and including inner basket made of high quality 304 grade stainless steel, double wall & glass wool insulated. Outer body shall be made of mild steel, PLC for automatic forwarding and reversing digital timer & temperature controller. All stainless steel parts of Drying Tumbler Machine shall be polished in glossy finish and all mild steel parts are painted with epoxy paint and have three coats of epoxy primer layer for long lasting and heavy duty operation including state of art control panel and electric motor of suitable HP with Starter. Technical specification are as follows :- (a) Loading Capacity - 30 kg (b) Operation cycle - 40-60 Min. (c) Inner Basket Size - 950mm dia x 850 mm depth (d) Vol. of inner Basket - 602 Ltrs (e) Basket Speed - 36-40 RPM (f) Opening Door Size - 650 mm dia Approx (g) Drive Motor - 0.75kW 1 (HP), 415v, 3 Ph, 50 Hz AC Supply Make - ABB/Schneider/Seimens (h) Blower Motor - 0.75kW 1 (HP), 415v, 3 Ph, 50 Hz AC Supply Make - ABB/Schneider/Seimens (j) Loading Door - Made from mild steel fitted with toughened glass. (k) Electric heating load - Fin type Air Heating element 18 kW Make - Neel/Dovy. (l) Waste Air Exhaust - 210 x 210 mm
4item No. 03 (contd....) (m) Make of Belt - Ecodrive/Alaska/ISI (n) Make of Bearing - ARB/NBC/SKF/URB (o) Insulation - Glass Wool (p) Lint Screen - Manual cleaning lint screen of SS for easy maintenance. (q) Suction Blower - Heavy duty aluminium cast suction blower driven by independent blower. (r) Thickness of SS Inner Basket - 1mm SS Perforated sheet fitted with back & front plate 1.5 mm to 1.6 mm SS Sheet 304 grade duly buffed and polished. (s) Outer body Front, Back & Side - Made of 1.2 mm to 1.6 mm MS Sheet (t) Overall dimension - 1050 mm W x 1500mm (D) x 1980mm (H) (u) Electrical Control box - L&T/Schneider/Seimens Make : As approved by E-in-C Branch Note Item No. 1 & 2 :- (a) Quoted rates including necessary PCC foundation as recommended by OEM. (b)Rates including complete installtion electrically and mechanically and testing in front of Engr-in-Charge and Accepting Officer. (c)Rates includes complete one Year warrenty after installation of Machines including replacement of defective parts and comprehensive maintenance for one year by OEM. (d) Rates includes one week teaching operation of machines to User Rep. (e)Water Connection is available upto the wall and Contractor should take a connection from wall to machines with gate valve and stainer.
5S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA "C" curvecomplete all as specified and as directed by the Engr-in-charge.
6S & layingas in repairsub main wiring with two run of 16 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 16 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium gradeISI marked of adequate size for housing the wirescomplete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
7Material & labourearthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron stripearth lead of 25x 4mm thick size by means of bolts, nuts, check nuts and washers of galvanised iron, earth strip protected by GI pipe 32mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note :-Cost of GI strip 25x4 mm thick upto 7.5 mtr length shall be includied in the quoted rate.
8Supply and fixing sheet metal enclosureVertical triple pole & neutral(VTPN), 415 volts, 4 way with 200 Amp rated bus bar, IP 54 protection, double door, with and including MCCB 4 Pole, 200 Amp, 415 Volts, breaking capacity 25 KA ,Adjustable Thermal Rangeas incomer,flush /surface mountingduly grouted in wall or on wooden board with lugs/thimbles duly crimped for connection complete all as specified and as directed by the Engr-in-charge. Make : L&T/Schneider/Seimens
9Supply and fixingMCCB 4 pole, 415 Volt,fixed type 125 Amps suitable for VTPN DB with breaking capacity 16KA complete all as specified and directed.Make : L&T/Schneider/Seimens
10Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable 50 sqmmcross sectional area, 3.5 corewith aluminium conductor, 1100 volts gradecomplete all as specified and as directedby Engineer-in-Charge.
11Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .
12Supply and lay GI tubing light grade withconnected fittings 32mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directedby Engineer-in-Charge
13Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including stretching the cable, complete all as specified and as directed . Note - Punned thickness of sand layer shall be measured and paid to contractor.
14Supply and laying well burnt brick class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cablecomplete all as specified and as directedby Engineer-in-Charge.
15Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
16Removing surplus excavated materialto a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
17M& L for cutting the existing hard standing/PCC/WBM roaddepth exceeding 45 cm and 30 cm in widthfor passing of cable through GI pipe and making good the disturbed surface with PCC (1:3:6) type C-1 using 20mm graded stone aggregate complete all as specified and directed.
18Supply and fixingMCB,100 Amps, TPN,415V, 10 kA,""C"" curve including testing and commissioning complete all as specified and as directed by the Engineer-in-Charge. Make : L&T/Schneider/Seimens.