Tender For Revival Of Gardapal-I Lip Under Sukruli Block In Mayurbhanj District Revival Works Including Installation Power Supply And Energisation Work Gardapal-I Lip Under Sukruli Block In Mayurbhanj District
Tender Value
15.46 Lakhs
Estimated cost
Bid Submission
08 Sep 2023
0 days left
EMD
15460
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
karanjia → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Revival Of Gardapal-I Lip Under Sukruli Block In Mayurbhanj District Revival Works Including Installation Power Supply And Energisation Work Gardapal-I Lip Under Sukruli Block In Mayurbhanj District
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 2 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 4 | PCC/RCC Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 5 | Fly Ash Brick work25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. |
| 6 | Fly Ash Brick work 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in Super Structure etc. complete as per the Engineer-incharge. |
| 7 | 12mm thick plaster in cement mortar (1:6) finished smooth to stone massonary after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 8 | 20 mm thick plaster in cement mortar (1:4) over roof slab. |
| 9 | Rigd smooth centering and suttering for RCC works including RCC Lintel Data (for 9.00 Sqms.) |
| 10 | Rigd smooth centering and suttering for RCC works including Roof slab, R.C.C. floor, Landing Balcony, Projection sun shed & Chajja, Sheles Data (for 9.00 Sqms.) |
| 11 | Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500) |
| 12 | Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 13 | 10cm thick dry brick khoa well watered and rammedto |
| 14 | 2.5 cm (1\") thick ArtificialStone flooring with cement concrete(1:2:4) including punningusing 12 mm size hard |
| 15 | Cost of M.S. fabricated Door & windowincluding fitting and fixing charges etc. complete. |
| 16 | White washing two coats with shell lime |
| 17 | Distempering two coats to wall |
| 18 | Wiring of pump chamber |
| 19 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. |
| 20 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 21 | Cost of 100mm dia G.I. Pipe |
| 22 | Cost of 100mm dia G.I.Bend |
| 23 | Cost of 100mm dia G.I. Flange |
| 24 | 100mm dia C.I. Screw boss Foot Valve of swing type friction less with single disc conforming to IS-4038/1979 of reputed brand with ISI mark of reputed company having wide dealership network including all cost, |
| 25 | Cost of 200mmdia P.V.C Pipe (Cl.II) 4 kg/cm² |
| 26 | Cost of 160 mmØ PVC Pipe (Cl-I) 2.5 kg/cm2 |
| 27 | Cost of 100 mmØ Sluice Valve |
| 28 | Cost of 100 mmØ C.I.Reflux Valve (NR) |
| 29 | Cost, supplying of 25mm dia Kirloskar make C.I single Air Release Valve (Standard) PN 1.6 with saddle and Raiser pipe conforming to IS 14845 (SI) with ISI mark including all cost, conveyance, cess etc complete |
| 30 | Cost of 200 x 200 x 100dia Weldless G.I. Tee(3.6mm thickness with bend closing and opening arragement of reputed company |
| 31 | Cost of 160 mm x 160 mm x 110 mm Ødia Weldless G.I. Tee(3.6mm thickness with bend closing and opening arragement of reputed company |
| 32 | 200 mmPVC Coupler (W.P 4kg/Cm2 ) agricultureal PVC fitings conforming to IS-4995/1988 with latest amendment |
| 33 | 160 mmPVC Coupler (W.P 4kg/Cm2 ) agricultureal PVC fitings conforming to IS-4995/1988 with latest amendment |
| 34 | Cost of 100x100x25mm G.I. Tee with Plug for priming |
| 35 | 219mm dia M.S.Pipe (6.30mm thickness) IS 3589:2001 with ISI mark of reputed company including all cost, conveyance, cess etc complete but excluding cost of GST(As per S/R 2022) |
| 36 | Cost of 12mm thick MS plate Flange 200mm dia ISI mark of reputed company |
| 37 | Cost of 200mm PVC Taill piece & flange |
| 38 | Cost of 160 mm PVC Taill piece & flange |
| 39 | Cost of welding & laying fitting 200mm M.S. Pipe |
| 40 | Labour charges for laying and fitting of 200 mm Ø PVC pipe |
| 41 | Labour charges for laying and fitting of 160 mm Ø PVC pipe |
| 42 | Labour charges for delivery andfitting including fitting of priming Tee, sluice Valve, NR Valve, air release valve and riser Tee etc and installation |
| 43 | Cost of Rubber insertion 3mm thick |
| 44 | Cost of Nut bolt |
| 45 | 150mm diaC.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022 |
| 46 | Cost of 200mmx100mm M S Reducer |
| 47 | 200x200x200 mm P V C Equal Tee(W,P 4Kg/cm2) conforming to IS-4995/1988 with latest amendment |
| 48 | 160X160X160mm P V C Equal Tee(W,P 4Kg/cm2) conforming to IS-4995/1988 with latest amendment |
| 49 | 200PVC End Cap(W,P 10Kg/cm2) conforming to IS-4995/1988 with latest amendment |
| 50 | 160 mm PVC End Cap(W,P 10Kg/cm2) conforming to IS-4995/1988 with latest amendment |
| 51 | Monoblock pump set total head of 24 mtrs capable to discharge 1700 LPM with 15 HP/11.2 KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery = 100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares.The materials as construction as given below.a)Caing FC 200 as per IS 210/1978.b) impeller Bronze grade LTB-2 of IS-318/1981 |
| 52 | Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP (13-20) with 16 Amp (AC-3) contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay & no volt coil with electronic pnemutic timer suitable for operation at voltage range of 300 to 440 V. including cot of traspotation to site. The Starter should provide dependable protection against over load and single phasing etc (BCH Make) |
| 53 | 63 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company having utilisation capacity cagegory AC- 22 |
| 54 | Cost of irrigation pannel board |
| 55 | Cost of motor Hood |
| 56 | Base plate for Motor |
| 57 | 4 KVAR Capaciter |
| 58 | Cost of3/16mm2 T.D Cabel |
| 59 | Cost of other Petty materials like connection wire Kitkat and Cabel Laying in trench & energisation |
| 60 | Electrical installation , Tranporation, energisation & including by party agreement. |
| 61 | Cost of outlet |
| 62 | Cost of Electrical Earthing |
| 63 | Construction and erection of 11/0.416 KV 25 KVA Star rated DP Sub-Stationconfirming to RE rule 1956. Mounted on 2.44 Mt long Structure, supported on 10 mt long PSC pole, Transformer Hard Channel & top Channel made of 2.8 mtr long 100X50X6 mm size MS channel, Transformer belting on 2.80 Mtr long 50X50X5mm size M.S. Angle, (all RECSPN. Std. F-3), with all accessories like, 3 pole 11 KV H.G. fuse (F-5) abd AB swithces (F-9) both mounted on 2.8 mtr long 75X40X6 mm size M.S. Channel and supported by 1.0 mtr long 50X50X5 mm M.S. angle, with 3 nos. 11 KV lightening Arrestor & Distribution box for 25 KVA S/S mounted on box ( 75X40X6 mm) to 2.5 mtr long pipe earthing (F-2) including cost of 50 sq mm 3.5 core LT cable connecting the supply line with 55 Sq mm AAA conductor, providing G.I. HT stay as required carping & padding of poles, Danger board at each pole. ., complete as per the direction of the site engineer incharge. |
| 64 | Boundary Wall with Gate of double pole mounted substation size 4.5mx3.00m x1.2m height mesonary toe wall from plinth bend with Grill gate (size 1.00m x1.2m) with locking arrangment with metal spreading of the substationetc. complete as per the direction of the site engineer incharge. |
| 65 | Construction of 3 Phase 11 KV line as per REC stanard confirming to RE rules 1956 with 10 mt long PSC pole support in 50 mtr span, 55 Sq mm AAA conductor, 11 KV \"V\" cross arm, with required no of 11 KV T & C Disc. Insulators & 11 KV Pin insulators, Carping & Padding of poles, Danger board at each pole, Anti Climbing devices, stay set at bending point and double stay at end point with 18 mm G.I. H.T Stay, concreting of stay with anchor plate guarding at road crossing etc., marking OLIC in every PSC pole in enamale paint including cost of all materials. WITHAB SWITCH & INTERPOSING POLE, INCLUDING CONVERSION 0.40KM 2Q TO 3Q, Labour trasportation, inspection and commissioning with cut point 1 No. etc., complete as per the direction of the site engineer incharge. |
| 66 | Construction of3-phase, 4-wire LT lineas per REC standard confirming to RE Rules 1956, with 9meter long PSC pole support in 50 meter span, 3X35+1X25 sqmm AB Cable, required numbers of 16 mm LT GI Stay-Set at bending point and double Stay at end point with required numbers of Suspension clamp,Dead end clamp and LT Stay Insulator, providing coil earthing at each pole ,Carping and Padding of Poles, Danger Board at each Pole with Anti-Climbing device etc. including cost of all other Fittings, petty materials, all labours, with liaison for inspection and commissioning& writing on the Pole as per prescribed colour code, etc, complete as per the direction of the site engineer in charge . |
AI Tender Summary
Tender Timeline
Aug 24, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 11, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender