| 1 | Supplying of all materials, labour, T&P for Erection, Installation, Testing, Commissioning etc. Erection of 1x25 KVA 11/0.4 KV DP Mounted DS With Brick Wall Boundary(To be Handed Over To TPSODL) = 01 No. including Stock, Storage & Insurance ,Transporation (as per REC Standard) and as per requirement of TPSODL (PART-I) |
| 2 | 9 mtr long, 300 KG, PSC pole. |
| 3 | Pressure Channel (100X50x6) mm. MS Channel 2.80 mtr. Long each 2 Nos With Galvanisation Charges @ Rs.13.00/Kg |
| 4 | Transformer Mounting Channel100x50X6mm MS Channel 2.80 mtr.long 2 Nos (9.20Kg/mtr.) With Galvanisation Charges @ Rs.13.00/Kg |
| 5 | AB Switch & HG Fuse Mounting Channel (75x40X6)mm MS Channel 2.8 Mtr long 4Nos (6.8 Kg./Mtr.) With Galvanisation Charges @ Rs.13.00/Kg |
| 6 | Cantilever chhanel for suppoting HG Fuse (75x40X6)mm MS Angle - 1 Mtr long2 nos (6.80Kg per mtr) with Galvanisation Charges @ Rs.13.00/Kg |
| 7 | Cantilever chhanel for suppoting HG Fuse (50x50X6)mm MS Angle - 1 Mtr long2 nos (4.50Kg per mtr) with Galvanisation Charges @ Rs.13.00/Kg |
| 8 | Angle for Cantilever Arrengment for AB Switch & HG Fuse (50X50X6) mmMS Angle 2mtr long 2nos (4.50 Kg./Mtr.) with Galvanisation Charges @ Rs.13.00/Kg |
| 9 | Transformer Belting (50X50X6)mm MS angle 2.80mtr long 2nos (4.50 Kg./Mtr.) With Side Angle Total (7mtr) with Galvanisation Charges |
| 10 | Anglefor Mounting LT distribution box (35x35x5)mm MS Angle - 1 Mtr long2 nos (3.50Kg per mtr) with Galvanisation Charges @ Rs.13.00/Kg |
| 11 | 11KV Disc Insulator (T & C)POLYMER |
| 12 | 11KV HW Fitting (T&C) type |
| 13 | 11KV AB Switch 3 pole 200 Amp |
| 14 | 11KV HG Fuse 3 pole 200 Amp |
| 15 | 11KV Lightening Arreser 9KV, 5KA |
| 16 | LT distribution box with MCCB,Alumunium Busbar of single bay with Kit Kat fuse for 25KVA S/S |
| 17 | HT stay set complete REC Construction Standard |
| 18 | HT Stay Insulator Type-C |
| 19 | Stay clamp ( 1.9Kg/Pair) |
| 20 | 7/10 SWG GI stay wire (Grade-2) |
| 21 | G.I. Pipe Earthing 40mm dia medium gauge 3mtr long for Earthing Device |
| 22 | Earthing for support (coil type) |
| 23 | No.6 G.I. Wire for Earthing |
| 24 | GI Flat (25X4 mm)for Nutral Earthing |
| 25 | G.I Bolts, Nuts & Washers |
| 26 | 25 KVA11/0.4KV (AL) transformer BIS Energy Level-II |
| 27 | LT3 & 1/2 core 35 mm2PVC cable |
| 28 | G.I. Base Plate (50x50x10)mm for Support (20Kg) |
| 29 | Sundries ( Paint, Danger Board, AI Binding Tape & Wire Insulating Tape, Anti Climbing Device, Clamp Connector, Jumpering Materials, Socket & Other Assesories Etc.,) |
| 30 | Supplying of all materials, labour, T&P for Construction of Civil works. |
| 31 | Materials for earthing including masonry work for earth pit Salt,Charcoal & Cement Plate Cover |
| 32 | Concreting for Support C.C. 1:3:6 by using 40mm HBG metal = (0.45Mx0.45Mtrx1.5)M3 = 0.3037cum @ 4158.84= 0.3037 x Rs.4185.84 = Rs.1263.03 or Rs.1270.00 (I) |
| 33 | Cement concreting for Stay Anchor plat C.C. foundation 1:3:6 by using 4cm size hard granite metal= (0.45Mx0.45Mtrx1.5)M3 = 0.3cum @ 4158.84 = 0.3037xRs.4185.84 = Rs.1263.03 or Rs.1270.00 |
| 34 | Construction of brickboundry wallfencing with Sand & Metal Spreading to the new DP Mounted DSS |
| 35 | Brick Masonry Wall for fencing of 5\" height with 9\" wall area 8\" 0\"x12\" 0\" |
| 36 | MS grillGate 1.5 Mtr. Height x 1.5 Mtr. Width made of 35x35x6 mmAngle & (25x6) Flat Angle for out side boarder withHorizontal & Vertical Crossing for.i) 35x35x6 mm MS Angle = 1.5 Mtr x 4 = 6 mtrs. @ 3 Kg/mtr = 18 Kg @ Rs.97.50/Kg.=Rs.1755.00/-( With Galvanisation Charges)ii) 25x6 mm G.I. flat = 1.5 mtrx8x2 = 24 mtr @ 1.2 Kg/mtr. = 28.80 Kg.@ Rs.97.50/Kg.=Rs.2808.00iii) Painting of Gate With 2 Coats.=Rs.300.00 Total Rs.( 1755.00+2808.00+300.00) = Rs. 4863.00 |
| 37 | Filling Sand @ Rs. 431.60 / Cum for ( 8ft x 12ft x 1/2ft) = 48Cft.= 1.359 Cum = 1.359 x 431.60 = Rs.586.54 Say Rs. 587.00 |
| 38 | 40mm size HBG [email protected]/Cumt for ( 8ft x 12ft x 1/4ft) = 24Cft.= 0.679Cum = 0.679x 981.36 = Rs.666.75 Say Rs. 667.00 |
| 39 | Sundries for Danger Board, Anti Climbing Device Etc., |
| 40 | Supplying of all materials, labour, T&P for Erection, Installation, Testing, Commissioning of 11 KV 3P - 3W, OHLine with3 Core 35mm2 11 KV XLPE Cable ( For Double Circuit, ie., 2x300mtrs.= 600 mtrs. 12 Span) over 11 Nos. 9mtr long, 300 Kg. PSC Poles including Stock, Storage & Insurance ,Transporation (as per REC Standard) and as per requirement of TPSODL |
| 41 | HT stay set complete |
| 42 | Stay Insulator |
| 43 | Stay Clamp or Stud Clamp |
| 44 | 7/10 SWG GI stay wire |
| 45 | Earthing for support (coil type) |
| 46 | G.I. Base Plate (50x50x10)mm for PSC Pole (20Kg) |
| 47 | G.I Nut, Bolt & Washers |
| 48 | 9 mtr long 300 KG PSC pole for Support |
| 49 | 11KV Lightening Arreser (for 11 KV XLPE Cable) |
| 50 | Heat shrinkable Jointing Kit for 3 core 35 mm211 KV XLEP Cable (outdoor type) |
| 51 | 3 core 35 mm211 KV XLPE Cable (armoured) A2XFY |
| 52 | 7/12 SWG Stay wire for Support of XlPE Cable |
| 53 | 11KV XLPE Cable Clamp to hold Support Wire |
| 54 | Pole Clamp for Eye Hook for XLPE Cable |
| 55 | Eye Hook for XLPE Cable |
| 56 | Suspension Clamp With Eye Hook for ABC |
| 57 | Conductor Dead End Clamp Suitable for Bare Massenger XLEP Ereiral Bunched Cable (25 - 70 mm) |
| 58 | G.I. Pipe Earthing 40mm dia medium gauge 3mtr long |
| 59 | (25X4) mm GI Flat for Earthing of XLEP Cable |
| 60 | Sundries for Danger Board, Anti Climbing Device Etc., |
| 61 | Supplying of all materials, labour, T&P for Construction of Civil works. |
| 62 | Materials for earthing including masonry work for earth pit Salt,Charcoal & Cement Plate Cover |
| 63 | Concreting for Support C.C. 1:3:6 by using 40mm HBG metal = (0.45Mx0.45Mtrx1.5)M3 = 0.3037cum @ 4158.84= 0.3037 x Rs.4185.84 = Rs.1263.03 or Rs.1270.00 (I) |
| 64 | Cement concreting for Stay Anchor plat C.C. foundation 1:3:6 by using 4cm size hard granite metal= (0.45Mx0.45Mtrx1.5)M3 = 0.3cum @ 4158.84 = 0.3037xRs.4185.84 = Rs.1263.03 or Rs.1270.00 |
| 65 | Supplying of all materials, labour, T&P for Service Connection 3Ph S/C For 8 KW Load including Stock, Storage & Insurance,Transporation (as per REC Standard) and as per requirement of TPSODL (PART-III) |
| 66 | 3.5C x 35 mm sqLT PVC Cable |
| 67 | G.I Wire No. 8 |
| 68 | Insulated Piercing Connector Type B Main 16 to 95 mm2 & Tap - 2.50 to 10 mm2 |
| 69 | Nutral Connector Type B Suitable for Main 35-70 mm2 AAAC & Tap - 2.50 to 10 mm2 Service Cable Covered by Black Weather Resistant Insulation Cover |
| 70 | Kitkat fuse 63 Amp |
| 71 | G.I. S/C Bracket |
| 72 | Sundries for Danger Board, Anti Climbing Device Etc., |
| 73 | Supplying of all materials, labour, T&P forInstallation, Fitting, Fixing, Testing, Commissioning etc. of Internal wing toRWSS Pump House including Stock, Storage & Insurance ,Transporation (as per REC Standard) and as per requirement of TPSODL . & RWSS. |
| 74 | Iron frame of size 3-0\"x4\"-6\" made out of flat angle wall mounted for fixing of bus bar, kit-kat, 63A and 32A and control pannel etc., |
| 75 | Supply & fixing of 38/40 mm dia Gi pipe of required length as per I.E. Rule with perforated holes from bottom to top and upper end threaded and fitted with suitable flange for making connection of earth continuity wire fixed by G.I. nut and bolt and the earth pit have an altimate layer of charcoal and salt & replastering the grooved , cutted walls of pump house with cement mortar after laying the wire from main switch to earth electrode. |
| 76 | Supply & fixing of 63A, 415V I.C. TPN main switch with fuse unit, 2 nos of 63Amp, 415V kit kat fuse mounted on the iron frame and 2 phase bus bar mounted on the iron frame for distribution of power supply with surface wiring to phase indicator point fixing on suitable size of metalic box with 3mm thick laminated plate with all accessories and connection. |
| 77 | Supplying and fixing of 32A, 415V, TPN main switch with double fuse unit fixed on MS frame with all accessories etc., complete. |
| 78 | Supply , fitting, fixing ofsuitable wiringupto single phase motor 2 nos with 63Amp main switch, 32 Amp main switch 2 nos with suitable bus bar and 63Amp. Kit kat unit indicator with provision of light point 3 nos, plug point-1no, fan point-1no, and 2 nos earthing device by providing 16Amp, 230V D.P. main switch fixed on frame with nut and bolt etc., complete |