Water Resources and Irrigation Government Departments Closing in 0 days TDR #39300596

Tender For Installation And Energisation Of Defunct Clips Including Power Supply Work For Turiguda-Iii L.I. Project Under Lanjigarh Block In Kalahandi District

Issued by Government Departments · lanjigarh, Odisha
Tender Value
8.02 Lakhs
Estimated cost
Bid Submission
07 Sep 2023
0 days left
EMD
8029
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
lanjigarh → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Installation And Energisation Of Defunct Clips Including Power Supply Work For Turiguda-Iii L.I. Project Under Lanjigarh Block In Kalahandi District

BOQ

Name of Work: INSTALLATION & ENERGISATION OF DEFUNCT CLIPS INCLUDING POWER SUPPLY WORK FOR TURIGUDA-III L.I. PROJECT UNDER LANJIGARH BLOCK IN KALAHANDI DISTRICT OUT OF STATE PLAN - 2022-23
Sl. No. Item Description
1Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge.
2Filling the foundation and plinth with excavated material as directed by the Engineer-incharge.
3Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.
4Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.
5Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge.
6Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
7Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in supper structure etc. complete as per the Engineer-incharge.
812mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
9Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
10Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.
11R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
1225mm thick A.S. flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
13Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500)
14White washing 2 coat with approve good stone lime including cost conveyance charges of materials including supply of labour, gum, indigo etc. required for the work complete as directed by the Engineer-incharge.
15MS Pannel Door double leaf with MS frame overall size including frame of height 1.2mt x 1.98 mt. Door & Window of size 1.2 Mtr X 0.9 Mtr with shutter of 20 gauge CR sheet pannel as per approved size & specification etc. complete including cost of all materials fitting and fixing the door etc. complete as per the direction of the Engineer-incharge.
16Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
17Supplying of 200mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
18Supplying of 160mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
19Fitting of un plasticised 200mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
20Fitting of un plasticised 160mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
21Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge.
22Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 12.5HP/9.3KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery = 100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares.
23Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp
2463 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.
25Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray / navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board.
26Base Plate made of MS Channel with holes
276 KVR Power shunt capacitor
283x 16 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.
294mm² 3 core submersible flat cable of ISI
30100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark.
31100 mm dia G.I. bend IS No.1239(Part-II/1992)
32100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand
33100 mm dia G.I. flange IS No.6392 / 1971
34100 mm Ø Sluice Valve Flanged type of Manufacturing Standard - BS 5163 / IS14846 Pressure Ratings PN10.
35100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement
36200 mm M.S. pipes with plain ends in random length of 4 to 7 mtrs. Confirming to BIS 3589 with minimum wall thickness of pipes should be 5.5 mm each pipe should bear ISI specification and manufacturers name / Trade mark. Steel grade of the pipe should be Fe330
37Cost of 200mm MS/Steel slipon flange
38Welding, laying and fitting of 200 mm Ø MS pipe
39200X200X100mm dia M.S outlet Tee made with 151mm ID and 159 mm OD M.S Pipe of 8mm thick 400mm long fitted with 1 mtr long 100mm dia M.S.Pipe welded with 2 nos of 100mm dia M.S.Flange in between the 1 mtr M.S.Pipe and 0.25 mtr long 100 mm dia M.S.Pipe fitted horizentally with 2 mtrs of 100mm dia M.S.Elbow with water locking arrangement made out of 1 no. of 100mm dia open flange and 1 no. of 100mm dia blind flange and with hinges gaskets arrangement that UPVC pipe should be inserted directly 100mm long inside the 151mm dia ID M.S.Pipe at the both ends painted with two coats of anti corosive paints in complete set.
40160X160X100mm dia M.S outlet Tee made with 151mm ID and 159 mm OD M.S Pipe of 8mm thick 400mm long fitted with 1 mtr long 100mm dia M.S.Pipe welded with 2 nos of 100mm dia M.S.Flange in between the 1 mtr M.S.Pipe and 0.25 mtr long 100 mm dia M.S.Pipe fitted horizentally with 2 mtrs of 100mm dia M.S.Elbow with water locking arrangement made out of 1 no. of 100mm dia open flange and 1 no. of 100mm dia blind flange and with hinges gaskets arrangement that UPVC pipe should be inserted directly 100mm long inside the 151mm dia ID M.S.Pipe at the both ends painted with two coats of anti corosive paints in complete set.
41Cost of 200mmx200mmx160mm PVC Equal Tee
42Cost of 200mm PVCTail piece with flange
43200 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment
44160 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment
45160 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment
46200 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment
47Cost of River Bank cutting & shaping for const. of P.F.
4850 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.
49100x100x25mm G.I. Tee with Plug
50Cost of 200 mmx160 mm PVC Reducer
51200 mmx100 mm M.S. Reducer Fabricated
52Cost of outlet
535/8 \" x12\" Nut bolt & washer F.T. for foundation
545/8 \" x3\" Nut bolt F.T. as per IS specification
551/2\" x2 1/2\" Nut bolt F.T.as per IS specification
56?\" thick Rubber Insertion as per IS specification
57Cost of 160 mm PVC Equal Tee
58Labour charges for installation of 12.5 HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge.
59Installation of 63 KVA,11/.4 KV Pole mounted Sub-Station using 9 Mtr long PSC pole with Stare Ratted Transformer as per the specification & estimate of DISCOM
60Construction of 11 K.V.Line 3 Ph 3 Wire with 9 Mtr long 300kg PSC pole using 55 sq.mm insulated Conductor 80 mtr span with all materials required for the same as per the specification & estimate of DISCOM
61L.T.Line 3ph 4w using 3x50+1x35sq.mm XLPE ABC & 8 mtr long PSC poles with fittings with all materials required for the same as per the specification & estimate of DISCOM
62Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3200mm for fixing of earthing pipe 2 Nos of size 40mm dia X 3000 mm length with required slotting in pipes & fittings with 40 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required 4mm2/2.5mm2 PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge

AI Tender Summary

OUR REF NO 39300596
AUTHORITY Government Departments
TENDER VALUE 8.02 Lakhs
LAST DATE 07-09-2023
Authority
Authority Name Orissa Lift Irrigation Corporation Limited
Work Description Installation And Energisation Of Defunct Clips Including Power Supply Work For Turiguda-Iii L.I. Project Under Lanjigarh Block In Kalahandi District
Basic Detail
Tender No OLIC-BPT-01/2023-24 Dt.17.08.2023
Bidding Type Tender
Location
City lanjigarh
State Odisha
Key Dates
Publish Date 24 Aug 2023
Submission Date 07 Sep 2023
Open Date 08 Sep 2023
Finance
Tender Value 8.02 Lakhs
Tender Fee 4000
EMD 8029
Exemption Not Available
Document List
53159c91-6c9e-4f5d-97ed-0c0ce8ebb1fc.html
BOQ_453071.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 08, 2023

Bid Opening Date

Technical bids will be opened and evaluated.