Tender For Construction Of New Terminal Building And Associated Work At Leh Airport. Sh Installation Testing And Commissioning Of On Grid Solar Photo Voltaic Power Plant System, Leh-Jammu And Kashmir

Airports Authority Of India has published Tender For Construction Of New Terminal Building And Associated Work At Leh Airport. Sh Installation Testing And Commissioning Of On Grid Solar Photo Voltaic Power Plant System. Submission Date for this Tender is 12-09-2023. Solar Power Plants Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39265649
Tender For Construction Of New Terminal Building And Associated Work At Leh Airport. Sh Installation Testing And Commissioning Of On Grid Solar Photo Voltaic Power Plant System
Open Tender
Indian
Jammu And Kashmir
Leh
12-09-2023

Tender Details

Construction Of New Terminal Building And Associated Work At Leh Airport. Sh Installation Testing And Commissioning Of On Grid Solar Photo Voltaic Power Plant System Itc Of On Grid Solar Photo Voltaic Power Plant System

Key Value

Document Fees
INR 1180 /-
EMD
INR 441726.0 /-
Tender Value
INR 2.20 Crore /-

BOQ Items

Name of Work:Construction of New Terminal Building & associated work at Leh Airport. SH : Installation, Testing & Commissioning of On-Grid Solar Photo-Voltaic Power Plant System
Sl. No. Item Description
1SH-I Installation, Testing & Commissioning of Solar PV System
2Design,Shifting, Installation, Testing and Commissioning of provided Monocrystalline Solar PV Modules of Jakson make, Brand -Helia, Model JH-550M, having power rating 550 Wp (Qty.= 1152 Nos. approx.) as specified in Technical data sheet, required to be transported from Gwalior Airport to Leh Airport i/c necessary packing as required, loading, unloading duly mounted on Flushed Type Terminal Building Roof top (made up of Standing seam Double skin Insulated Roofing over MS Structure) of New Terminal Building with suitable mounting structure & the same shall be designed & installed by suitable size solar clamp and anodized aluminium channels alongwith the suitable size fasteners to maintain proper ventillation of the arrays of modules, holding of module with metallic roof sheet groove and solar module tightly without drilling / puncturing the metallic roof sheet i/c carrying out shadow analysis and shall capable to withstand the wind speed up to 150KMPH with anti-corrosion feature considering altitude of 3515m above MSL, ambient temperature Max. 40°C; Min. -30°C including levelling, connecting Modules with not less than Single Core 4sqmm, 1500V PV Copper Wire to form a Array-String,providing and fixing of suitable size IP 65 DC outdoor type Junction box (JB) for connecting the module outputwith the provision for Isolation, String Monitoring and Control for each String including suitable mounting arrangement for JB, providing and laying of DC Cabling not less than Single Core 6 Sq.mm (1.5 KV)Copper Cable of suitable runs from the JB to Invertersubject to voltage drop shall not exceed 2%, in50 mm dia heavy duty UPVC Pipe including SS clamping which shall be laid on covered GI perforated cable tray of suitable size as required, Termination of Cables with glands and lugs, Earthing of Modules and Structures throughout with 25 X 5 MM GI Strip, Marking of DC Cable Routes etc. as required.
3Design,Shifting, Installation, Testing and Commissioning of Total Capacity of 500 KW (AC) Power Conditioning Unit/Inverter Grid Connected Photovoltaic with duly provided Outdoor Type IP 66 String Inverter of each Capacity 125 KW (AC) having Make- Growatt, Model- MAX125KTL3-XLV (Qty.-04 Nos.) i/c transportation of said inverters from Gwalior Airport to Leh Airport i/c necessary packing as required, loading, unloading etc followed with mounting arrangement, connection, interconnections, earthing, termination of DC cables with necessary glands and lugs into Inverters etc. complete all as required as specified.
4Design, Supply, Installation, Testing and Commissioning of a Solar Radiation and Environment/Weather Monitoring System (WMS) to monitor and communicate the Parameters Like Global Horizontal Irradiance – Pyranometer, Collector Plane Irradiance – Pyranometer, Ambient Temperature, Module Temperature, Wind Speed and Direction, Relative Humidity Rain Fall/Precipitation including providing and fixing of requisite Instruments/Sensors/Computer Hardware and licence free Software etc. complete all as required. Note:- Scope of Communication through OFC cable has been considered in seperate BOQ item.
5Design, Supply, Installation, Testing and Commissioning of SCADA System for SPV PP for Local and Remote Web Based Monitoring to Monitor / Communicate and Control as applicable for Environment Monitoring System/PV Modules/String Monitoring Unit/Inverter/DC-AC Switch Gears/LT Panels for Electrical Parameters and Weather Parameters including providing and fixing of requisite Computer Hardware and Software etc.complete all as required and as specified. Note1:- The SCADA System consist of two PC Systems with one Desktop at Server installed in BMS room of Utility building and one Desktop shall be provided in the AAI Electrical room of Terminal building for remote performance monitoring of the System. Note2:- Scope of Communication through OFC cable has been considered in seperate BOQ item
6Provision of DG Sets & Solar PV power Plant control systems by developing logic in such a way that whenever the Grid supply fails and DG sets are put in operation, the controller will ramp down the solar power generation by controlling the Inverters to avoid DG hunting etc including laying of suitable size controlling and communication cables, fixing of tower lamp Annunciation buzzer in Power house, Electrical control room etc. complete all as required and as specified. Note1:- Atleast Two nos. of controller panel are required to be provide. One in Terminal building and one in Utility building. Note2 :- The Quote for this itemcovers the scope of providing and laying of controlling and communication cables.
7SITC of 5 KVA UPS along with suitably designed VRLA Battery having minimum back up time of 1 Hour with MS Racks for SCADA System including providing and fixing Copper Wiring (with suitable size Cable) for Input and Output Cabling, termination etc., as required.
8SH-IISITC OF LT COMBINATION PANEL
9Fabrication, Supply, Installation, Testing and Commissioning of 3 phase, 415V TPN, 50Hz, AC System, draw out Cubicle type, Single front, free standing floor mounted, Totally enclosed, top cable entry, metal enclosed switchboards(LT AC Combination Panel) suitable for operation at indoor site conditions (min. temp. -5 degree celsius, design temp. +40 degree celsius, storage temp. of -22 degree celsius, altitude of 3515 m above m.s.l.) made out of 2mm Thick CRCA Sheet Steel for Outer Shell and 1.6 mm Thick CRCA Sheet forInner Partition complete with all accessories, interconnection, CTs, PTs, connection, earthing, powder coated, provision of bottom base channel and locking arrangements etc.,as per approved drawings, specifications complete all as required and comprising of the following:
101 Set of 415V, 1600 A, Al. Bus-bars, 50 KA for 1 Sec switch board with following feeders.
11A) Six Nos. (04 nos Working + 02 Nos. Spare) of 320 A, 50 KA, 4P MCCB (Ics=100%Icu) with Microprcessor based Releases for OC/SC/EF Protection andROM as INCOMER (w r t Solar from Individual Inverter) with Resin Cast C.T. operated Digital Meter [EM6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps,All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required.
12B) One No. of1250A, 50 KA, 4P , MDO , ACBwith Microprcessor based Releases forOC/SC/EFProtection and ROMasOUTGOING (w r t Grid),with ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required.
13Total LT Panel mentioned above
14SH-III CABLING WORKS
15Supplyof XLPE insulated and PVC sheathed AluminiumConductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part-I) 1988 as amended upto date and of following size as required: a) 3.5 X 300 SQ MM
16Supplyof XLPE insulated and PVC sheathed CopperConductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part-I) 1988 as amended upto date and of following size as required: a) 3.5 X 95 SQ MM
17Laying and Fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) on the existing cable tray as required.
18Laying and Fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 35 sq. mm and upto 95 sq. mm (clamped with 40x3mm MS flat clamp) on the existing cable tray as required.
19Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 X 300 SQ MM
20Supplying and making indoor end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 X 95 SQ MM
21Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required a) 3.5 X 300 SQ MM
22Supply of 06 F OFC of Single Mode, armoured, multi tube, double sheath, suitable for outdoor application conforming to ITU-T-G652 & IEC60973 & 60794 with up-to date amendments as required.
23Supply of Permanently Lubricated HDPE Pipe of 40 mm Outer dia and 33 mm inner dia made ofPE 100 Material and suitable for PressurePN 6 as required on the existing cable tray as required.
24Supply and making of splicing and termination of 06 F OFC inTerminal box including providing all accessories and SpecialisedManpower complete as reqired.
25Laying [by Pulling/Blowing] of OFC of up to 24F with PLB-HDPE Pipe, Sealing of Pipesetc., as required on the existing cable tray as required.
26SH-IV EARTHING WORKS
27Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
28Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.-(Module Strucure Continuous Earthing is not covered )
29Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.-(Module Strucure Continuous Earthing is not covered )
30Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.(Module Strucure Continuous Earthing is not covered).
31Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
32Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required-(Module Strucure Continuous Earthing is not covered).
33Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required-(Module Strucure Continuous Earthing is not covered).
34SH-VLIGHTING CONDUCTOR & FIRE PROTECTIONITEMS
35Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as required.
36Providing and laying G.I. tape 32 mm X 6 mm from finial on surface as required.
37Providing and laying G.I. tape 32 mm X 6 mm from earth electrode (Finial) directly in ground as required.
38Providing & fixing of Carbon-dioxide (CO2) Type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity as required.
39Supply and fixing of foam type fire extinguishers [Portable Type of 9 Litre Capacity] as required
40Supply and fixing of foam type fire extinguishers [Portable Type of 9 Litre Capacity] as required
41Supply and fixing of Safety Instruction Chart (in words) duly framed with 5mm thick glass complete as required.
42Providing & fixing a set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour and written with white paint "Fire" and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand complete as required.
43SH-VI APPROVALS
44PreparationofDrawings,necessary data i/c Liasoning Work for getting Approval and obtaining sanction for energization of Solar PV system and associated Electrical Systemfrom Central Electricity Authority/EB/Any other Nodal Agency of Central/State Government as required.
45Carrying out of Glare Analysis and Reflection Analysis for Airport Operation with respect to positioning of PV Modules, Submission of Reports, Assisting AAI in getting NOC/Clearance from AAI NOC Wing/DGCA/Other Statutories Bodies related to Safety,Recommendation for suitable installation Procedure forSafe Operation of Aircrafts etc.,as required.
46SH-VII PART B.OPERATION & ALL INCLUSIVE COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT (AICAMC)
47Operation & All Inclusive Comprehensive ANNUAL Maintenance Contract ofGrid Connected 500 KW (AC) at Roof Top of New Terminal Building at Leh Airport as per the SCC & as specified.
48Operation of 500KW AC solar PV plant during one year DLP- First year
49Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Second year
50Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Third year
51Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS- Fourth year
52Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Fifth year
53Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Sixth year
54Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Seventh year
55Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS- Eighth year
56Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS- Ninth year
57Operation & CMC of 500KWAC Solar Module + 4X125KVA Inverter + SCADA system + WMS - Tenth year
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail