Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #39254295

Tender For Supply, Installation & Commissioning Of Inverted Phase Contrast Fluorescence Microscope

Issued by Boards / Undertakings / PSU · Kolhapur, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Offline

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolhapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply, Installation & Commissioning Of Inverted Phase Contrast Fluorescence Microscope No. Name & Specification Qty Rate inclusi ve all taxes, GST etc Inverted phase contrast fluorescence microscope 1 Microscope: Bright field, phase contrast, LED fluorescence Observation modes. Light Filters: High-power LED with brightness control and 3-position filter holder with blue and green filter sets included Blue filter: LED emission 460 nm, Excitation filter 455-495 nm, Dichroic mirror cut-off 500 nm and Emission filter 510LP nm Green filter: LED emission 523 nm, Excitation filter 510-550 nm, Dichroic mirror cut-off 570 nm and Emission filter 575LP nm. Head: Trinocular (2-position 100/0, 50/100), 45° inclined head with interpupillary distance Adjustable between 50 and 75 mm Eyepiece adjustments: Dioptric adjustment on the left eyepiece tube Eyepieces: WF10x/22 mm with high eye-point and rubber cups Nosepiece: Quintuple revolving nosepiece must have rotation on ball bearings Objective parameters: Infinity corrected long working distance of IOS LWD W-PLAN PH Objective 10x/0.25, IOS LWD W-PLAN PH Objective 20x/0.40, IOS LWD W-PLAN PH Objective 40x/0.65 All the objectives must have anti-fungus treatment. Stage: Fixed stage of 250×160 mm with glass and metal stage inserts. Optional stage: Mechanical stage Tension control: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen, LWD pre-centered condenser, N.A. 0.30, W.D. 72 mm. With 4x/10x, 20x/40x phase contrast slider and bright field. It must be removable to extend the working distance up to 150 mm. Display: X-LED8 with white 8 W LED (6,300K) with brightness control for transmitted illumination with aperture diaphragm Power: 100-240Vac/12Vdc external power supply Imaging: Digital CMOS Camera of 5.1 Mega Pixel Camera Resolution: 2592 x 1944 with Sensor Size of 1/2.5”, technology CMOS and type Aptina CMOS Camera: Pixel size of 2.2 x 2.2 µm, Frame rate full resolution of 7 fps (2592 x 1944) and Frame rate other resolutions 27 fps (1280x 960); 90fps (640x 480) Sensitivity: 0.53 V/lux-second Signal / noise ratio: 40.5 dB Analogue to Digital Converter: ADC conversion of 8 Bit and Colour Depth of 1 Bit; 4 Bit; 8 Bit; 24 Bit Exposure time: 0.294 msec - 2 sec IR filter: 380-650 nm (IR-cut filter) Add on: Calibration Slide and 1.8 m USB cable included Computer: Win 10 (32 or 64 bit) or OSx (Mac OSx) starting from 10.7.5, Linux operating system, CPU Equal to Intel Core2 2.8GHz or higher RAM: 16 GB or more USB port: USB 2.0, at least two ports. Software: Compatible software for Continuous auto white balance, continuous auto exposure, image size, image capture, compressed video capture, measurement, count, archiving, saving data, Image and video Acquisition, Documentation, etc. Also, it must come with M-620.1 C mount adapter 0.5x

AI Tender Summary

OUR REF NO 39254295
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 31-08-2023
Authority
Authority Name University Shivaji University
Work Description Tender For Supply, Installation & Commissioning Of Inverted Phase Contrast Fluorescence Microscope No. Name & Specification Qty Rate inclusi ve all taxes, GST etc Inverted phase contrast fluorescence microscope 1 Microscope: Bright field, phase contrast, LED fluorescence Observation modes. Light Filters: High-power LED with brightness control and 3-position filter holder with blue and green filter sets included Blue filter: LED emission 460 nm, Excitation filter 455-495 nm, Dichroic mirror cut-off 500 nm and Emission filter 510LP nm Green filter: LED emission 523 nm, Excitation filter 510-550 nm, Dichroic mirror cut-off 570 nm and Emission filter 575LP nm. Head: Trinocular (2-position 100/0, 50/100), 45° inclined head with interpupillary distance Adjustable between 50 and 75 mm Eyepiece adjustments: Dioptric adjustment on the left eyepiece tube Eyepieces: WF10x/22 mm with high eye-point and rubber cups Nosepiece: Quintuple revolving nosepiece must have rotation on ball bearings Objective parameters: Infinity corrected long working distance of IOS LWD W-PLAN PH Objective 10x/0.25, IOS LWD W-PLAN PH Objective 20x/0.40, IOS LWD W-PLAN PH Objective 40x/0.65 All the objectives must have anti-fungus treatment. Stage: Fixed stage of 250×160 mm with glass and metal stage inserts. Optional stage: Mechanical stage Tension control: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen, LWD pre-centered condenser, N.A. 0.30, W.D. 72 mm. With 4x/10x, 20x/40x phase contrast slider and bright field. It must be removable to extend the working distance up to 150 mm. Display: X-LED8 with white 8 W LED (6,300K) with brightness control for transmitted illumination with aperture diaphragm Power: 100-240Vac/12Vdc external power supply Imaging: Digital CMOS Camera of 5.1 Mega Pixel Camera Resolution: 2592 x 1944 with Sensor Size of 1/2.5”, technology CMOS and type Aptina CMOS Camera: Pixel size of 2.2 x 2.2 µm, Frame rate full resolution of 7 fps (2592 x 1944) and Frame rate other resolutions 27 fps (1280x 960); 90fps (640x 480) Sensitivity: 0.53 V/lux-second Signal / noise ratio: 40.5 dB Analogue to Digital Converter: ADC conversion of 8 Bit and Colour Depth of 1 Bit; 4 Bit; 8 Bit; 24 Bit Exposure time: 0.294 msec - 2 sec IR filter: 380-650 nm (IR-cut filter) Add on: Calibration Slide and 1.8 m USB cable included Computer: Win 10 (32 or 64 bit) or OSx (Mac OSx) starting from 10.7.5, Linux operating system, CPU Equal to Intel Core2 2.8GHz or higher RAM: 16 GB or more USB port: USB 2.0, at least two ports. Software: Compatible software for Continuous auto white balance, continuous auto exposure, image size, image capture, compressed video capture, measurement, count, archiving, saving data, Image and video Acquisition, Documentation, etc. Also, it must come with M-620.1 C mount adapter 0.5x
Basic Detail
Tender No 915/AMENDMENT-0/19-Jul-2023
Bidding Type Tender
Location
City Kolhapur
State Maharashtra
Key Dates
Publish Date 21 Aug 2023
Submission Date 31 Aug 2023
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 3540
EMD 50000
Exemption Not Available
Document List
c6e640e0-d59e-450e-aa7c-8b57bd3ce06a.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2023
17:00 IST

Bid Submission Deadline

Offline submission at the designated office.

Completed

Tender Documents

Download All (ZIP) ↓
rar

c6e640e0-d59e-450e-aa7c-8b57bd3ce06a.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders