}

Tender For Special Repair / Replacement Conversion Of Ht Oh Line To Ug Line And Water Supply Systemaf Stn Sarsawa Under Ge (Af) Sarsawa, sarsawa-Uttar Pradesh

Military Engineer Services-MES has published Tender For Special Repair / Replacement Conversion Of Ht Oh Line To Ug Line And Water Supply Systemaf Stn Sarsawa Under Ge (Af) Sarsawa. Submission Date for this Tender is 19-09-2023. Overhead Line Tenders in sarsawa Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39249590
Corrigendum : Tender For Special Repair / Replacement Conversion Of Ht Oh Line To Ug Line And Water Supply Systemaf Stn Sarsawa Under Ge (Af) Sarsawa
Open Tender
Indian
Uttar Pradesh
sarsawa
19-09-2023

Tender Details

Special Repair / Replacement Conversion Of Ht Oh Line To Ug Line And Water Supply Systemaf Stn Sarsawa Under Ge ( Af ) Sarsawa; 1 M&L Earthing Complete With Galvanized Steel Earth Plate 60Cm X 60Cm X 6Mm Thick Buried Vertically In Ground To Depth Not Less Than 2.25 Mtr Below Ground Level, With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Gi Earth Lead Strip 32Mm X 6Mm Upto 7.5 Mtr Long By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron And Connection To Earthing Test Point& Earth Dolly Including Watering Pipe Gi 20 Mm Boremedium Grade 2.5 Mtr Long Including Protection Pipe Gi Medium Grade 40Mm Bore 7.5 Mtr Long, Wire Mesh, Funnel, Lugs, Salt, Charcoal Dust, Excavation & Earthwork In Soft / Losse Soil And Refilling Pit Chamber With Pcc 1:3:6 Type C-1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates , Rcc 1:2:4 Type B-1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates Pit Cover Slab 40 Mm Thick Reinforced With 8 Mm Dia Tmt Bars @ 15Cm C / C Both Ways Including Necessary Form Work All As Shown In Electrical Plate No 3 Of Ssr Part-I, Including Testing On Completion On Site Complete All As Specified & Directed. Notes :- Any Variation In Length Of Earth Lead And Protection Pipe Of Earth Lead Shall Be Measured & Paid Seperately. On Testing If The Earth Resistance Is Not Obtained, Earthing Will Be Generated At No Extra Cost, Till The Desired Earth Resistance Is Obtained. The Chamber Shall Be Constructed Atleast 1.5 Mtr Away From The Earth Electrode. 2 S&F 32Mm X 6 Mm Galvanized Iron Strip As Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Situation For Loop Earthing Etc. As Requiredcomplete All As Specified & Directed 3 Supply, Laying, Jointing, Testing And Commissioning Ht Xlpe Cable ( Heavy Duty ) , 11000 Volts ( Earthed ) , Insulated, Screened, Sound Compacted Aluminium Conductor, Screening With Extruded Semi Conducting Layers, Insulation Screening With Copper Tape Covers Laid Up With Pvc ( St-2 ) , Extruded Inner Sheathed Gi Strip Armoured Pvc ( St-2 ) Out Sheathed, Isi Marked With Is-7098 Part Ii With Amendment, Size Cross Sectional Area 95 Sqmm, 3 Core, Laid In Trenches / Pipes / Ducts / Along Poles / Walls / Equipment Etc Complete All As Specified & Directed. Notes: ( I ) Cable Shall Be Of Manufacturing Date Not Earlier Than May 2023. All The Cable Shall Be Embossed With Year Of Manufacturing, Meterage At Every Metre, In Addition To Its Own Standard Markings As Per Is I.E. Size, Voltage Etc. ( Ii ) Excavation & Earth Work, Sand Cushioning, Protection Pipes, End Termination Joints & Protection Covers Shall Be Measuredand Paid Separately. ( Iii ) No Straight Through Joint Shall Be Permitted In Less Than Single Drum Length. ( Iv ) The Contractor Shall Produce Original Purchase Vouchers Duly Machine Numbered Alongwith Excise Duty Gate Pass Of Factory For Verification And Record. ( V ) Cable Shall Be Tested In The Presence Of Rep Of Accepting Officer At Factory Premises Prior To Despatch. 4 Excavation In Trenches, Not Exceeding 1.5Mtr Wide & Not Exceeding 1.5Mtr In Depth; For Foundation, Laying / Taking Out Pipes / Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10Sqm On Plan & Not Exceeding 1.5Mtr In Depth And Getting Out, In Soft / Loose Soil Complete All As Specified & Directed. 5 Excavation In Trenches, Not Exceeding1.5Mtr Wide And Exceeding 1.5Mtr But Not Exceeding 3.0Mtr In Depth; For Foundation, Laying / Taking Out Pipes / Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10Sqm On Plan & Not Exceeding 1.5Mtr In Depth And Getting Out, In Soft / Loose Soil Complete All As Specified & Directed. 6 Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each In Soft / Loose Soil Complete All As Specified & Directed. 7 Removal Of Excavated Soil To A Distance Not Exceeding 50 Mtr & Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified & Directed. 8 Supply & Laying Un-Reinforced Precast Concrete Cable Cover , Class Hv Type-1 Flat, Size 300Mm X 180Mm X 40Mm, Laid Flatfor Protection Of Cable , Adjacent To Each Other, Perpendicular To Central Axis Of Cable Complete All As Specified & Directed. 9 M&Lsand Cushioning To Cable With A Layer Of Sand 8 Cm Deep Before Laying The Cable And 15 Cmdeep After Laying The Cable ( Punned Down To 18 Cm Depth After Laying And Stretching Of Cable ) Complete All As Specified & Directed. 10 S&F Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination, Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm Complete All As Specified & Directed. 11 Dismantling Of Steel Tubular Poles, Strut Any Size Complete All As Specified & Directed. 12 Dismantling Of Insulators Any Type, Any Size Complete All As Specified & Directed. 13 Dismantling Of Acsr Or Aac Overhead Conductors Complete All As Specified & Directed. 14 Dismantling Of Cross-Arms Of Ms Channel Or Angle Sections Etc. Complete All As Specified & Directed. 15 M&L True Vertical Steel Tubular, Swaged Welded Pole Conforming To Is-2713 Part Ii , Type 410 Sp 55, 11 Metre Long Complete With Mild Steel Base Plate Of 6 Mm Thick Of Size 300Mm X 300Mm, Finial Taper Plug, Cap, Bolts, Nuts, Washer And Screws Hole Of Required Size And Nos. For Fixing Cross Arms Including Painting Externally With Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer For Exposed Surface And Two Coats Of Black Bituminious Paint For Embeded Portionin Concrete As Well As Throughout Internally Including Provision Of White & Blue Colour Strips With Fluorescent Paint Upto 1.5 Mtr Height & Nubmering Of Pole Complete All As Specified & Directed.Note:-Excavation, Earth Workandpccshall Be Measured And Paid Separately. 16 M&L Pcc 1:4:8, Type D2, Using 40Mm Graded Mechanically Crushed Stone Aggregate As In Foundation, Filling And Mass Concrete Complete All As Specified & Directed. 17 M&L Pcc 1:3:6, Type C2, Using 40Mm Graded Mechanically Crushed Stone Aggregate As In Foundation, Filling And Mass Concrete Complete All As Specified & Directed. 18 M&L Pcc 1:2:4, Type B1, Using 20Mm Graded Mechanically Crushed Stone Aggregate As In Copping Of Poles / Stay / Panel Including Formwork For Fair Surface Complete All As Specified & Directed. 19 S&F Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Applying Two Coats Of Synthetic Enamel Paintover & Including One Coat Of Redoxide Oxide Primer Complete All As Specified & Directed. 20 S&F Anti Climbing Device, Spikes Type Fabricated Out Of Ms Bars , Round Square And Flat With And Including Providing Required Nuts , Bolts, Washers Etc., Welding In Two Halves, Made To Shape, To Suit The Cross Section Of The Pole And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Complete All As Specified & Directed. 21 S&F Ht Lightning Arresters For Outdoor Use, Non-Liner Resistor Type, Horn Gap And Choking Coil, Maximum Working Pressure 11000 Volts, Transmission Class, Discharge Capacity 10 Kiloampere Complete All As Specified & Directed. 22 M&L For Augering Upto 100Mm Bore For Road Crossing 3 Mtr To 10 Mtr ( In Length ) Not Exceeding 1.5 Mtr In Depth In Soft / Loose Soil For Laying Of Electric Cable And Gi Tubing Etc. Complete All As Specified. 23 Supply, Installation & Testing Of Switch Air Break Gang Operated, Triple Pole, For Horizontal Or Vertical Operation, Mechanically Operated, Mounted On 12 Insulators And Steel Frame With Operating Mechanism & Operating Rod Of 25Mm Bore, Medium Grade Gi Pipe From Ground Level With Locking Arrangements, 200 Amps Rating 11000 Volts Working Pressure Including Making Electrical Connectionsto Make It Functional After Testing Complete All As Specified & Directed. 24 S&F Cable Route Indicator, Showing Mes Ht Under Ground Cable And Arrow Mark Painted With Two Coat Synthetic Enamel Paint Over & Including One Coat Of Zinc Oxide Primer, Made Out Of Ms Plate Of Size 200Mm X 200Mm, 6Mm Thick Fixed On Ms Flat Of Size 25Mm X 4Mm, 600Mm Long, Including Cutting, Chasing, Drilling, Welding Etc. ( Whichever Required ) And Embedded In Pcc Block 1:3:6, Type C-2 Of Size 30Cm X 30Cm X 30Cm In The Ground Including Excavation And Earth Work Complete All As Specified & Directed.Note: Excavation & Earthwork And Pcc Work Included In Quoted Rates. 25 M&L Double Wall Corrugated ( Dwc ) Hdpe Pipe Outer Dia 90Mm & Inner Dia 75Mm, Confirming To Is 4984 With End Cap As In Trenches / Under Road / Under Floor Including Cutting Road / Floor And Making Good Wherever Necessary Or Fixed To Wall / Pole With Fixing Arrangement With Suitable Size Of Ms Clamps Made From Flat Iron Including Nuts, Bolts & Washers For Cable Protection Complete All As Specified & Directed. Note: Excavation For Trenches Shall Be Measured & Paid Seperately. The Working / Installation Of Pipe Shall Be Confirming To Is 14930 26 M&L Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Signal Red Colour, Fixed With Ms Clamps, Bolts And Nuts, For Ht Of 25Cm X 20Cm Size As Per Ssr Part-I Dully Painted With Two Coats Of Aluminium Paint Complete All As Specified & Directed. 27 S&F Pin Type, Porcelain, Vitreous, White, Brown Or Green Insulator Including One Galvanised Mild Steel Spindle, Two Galvanised Iron Washers And One Galvanised Iron Nut, 150 Mm Height, 150Mm Dia For 11000 Volts Grade Complete All As Specified & Directed. 28 M&L Earthing Complete With Galvanized Steel Earth Plate 60Cm X 60Cm X 6Mm Thick Buried Vertically In Ground To Depth Not Less Than 2.25 Mtr Below Ground Level, With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Gi Earth Lead Wire 4.00Mm Dia Upto 7.5 Mtr Long By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron And Connection To Earthing Test Point& Earth Dolly Including Watering Pipe Gi 20 Mm Bore, Light Grade Including Protection Pipe Gi Medium Grade 15Mm Bore , Wire Mesh, Funnel, Lugs, Salt, Charcoal Dust, Excavation & Earthwork In Soft / Losse Soil And Refilling Pit Chamber With Pcc 1:3:6 Type C-1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates , Rcc 1:2:4 Type B-1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates Pit Cover Slab 40 Mm Thick Reinforced With 8 Mm Dia Tmt Bars @ 15Cm C / C Both Ways Including Necessary Form Work All As Shown In Electrical Plate No 3 Of Ssr Part-I, Including Testing On Completion On Site Complete All As Specified & Directed. Notes :- Any Variation In Length Of Earth Lead And Protection Pipe Of Earth Lead Shall Be Measured & Paid Seperately. On Testing If The Earth Resistance Is Not Obtained, Earthing Will Be Generated At No Extra Cost , Till The Desired Earth Resistance Is Obtained. The Chamber Shall Be Constructed Atleast 1.5 Mtr Away From The Earth Electrode. 29 S&F 4.0Mm Dia Galvanized Iron Wire As Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Situation For Loop Earthing Etc. As Requiredcomplete All As Specified & Directed 30 Excavation In Trenches, Not Exceeding 1.5Mtr Wide & Not Exceeding 1.5Mtr In Depth; For Foundation, Laying / Taking Out Pipes / Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10Sqm On Plan & Not Exceeding 1.5Mtr In Depth And Getting Out, In Hard / Dense Soil Complete All As Specified & Directed. 31 Supply And Laying Old Size, Common Burnt Clay, Sub Class B Bricks, Designation 75, Laid Flat & Dryfor Protection Of Electric Cable In Trenches, Adjacent To Each Other, Perpendicular To Central Axis Of Cable Complete All As Specified & Directed. 32 Taking Up Or Down Old Unserviceable Pvc Water Tubing Of Any Type And Any Size From Trenches Or Walls Etc. Complete All As Specified & Directed. 33 M&L Hdpe Pipe Pe 100, Sdr-17, Dn ( Nominal Od ) 50Mm, Pn-6, Confirming To Is 4984:2016 ( Reaffirmed 2021 ) With All Fittings, Laid In Trenches / Floor Or Fixed In Wall Complete All As Specified & Directed. 34 M&L Hdpe Pipe Pe 100, Sdr-17, Dn ( Nominal Od ) 63Mm, Pn-6, Confirming To Is 4984:2016 ( Reaffirmed 2021 ) With All Fittings, Laid In Trenches / Floor Or Fixed In Wall Complete All As Specified & Directed. 35 M&L Hdpe Pipe Pe 100, Sdr-13.6, Dn ( Nominal Od ) 75Mm, Pn-8, Confirming To Is 4984:2016 ( Reaffirmed 2021 ) With All Fittings, Laid In Trenches / Floor Or Fixed In Wall Complete All As Specified & Directed. Note For Boq Item No. 33.00 To 35.00: Excavation And Earthwork Shall Be Measured & Paid Separetely. 36 S&F Vertical High Efficiency Filter Of Nominal Dia Minimum 50Mm At Inlet And Outlet With Nominal Dia Of Minimum 40Mm At Backwash / Bypass Having Maximum Pressure Rating Not Less Than 10 Kg / Sqcm, Nominal Opertating Pressure 6 Kg / Sqcm, Nominal Flow Rate 20 Cum / Hr, Flow Rate Of 101 Cum / Hr / Sqm, Backwash Flow Rate Of 8 Cum / Hr, Quantity Of Media 120 Kg, Filter Media Should Be Of High Quality Silica Sand Duly Crushed Silica Sand / Quartz Gravel Of Particle Size 1 Mm To 2 Mm ( 0.039 Inch To 0.078 Inch ) , Minimum Gross Weight Not Less Then 67 Kg Including All Nuts Bolts Etc Fixing Arrangment Required At Site To Fix The Hydrocyclone Filter Complete All As Specified & Directed. Note: The Testing Of Filter Shall Be Done In Presence Of Ge And Test Report Shall Be Submitted To Rep Of Accepting Officer. 37 S&F Disc Clean L Filter Having Nominal Flow Rate Of 25 Cum Per Hr Nominal Size 63 Mm, Nominal Pressure 6 Kg / Sqm And Size Of Aperture 100 Mesh Including All Fixing Arrangement Required At Site To Fix The Vertical High Efficiency Filter Complete All As Specified & Directed. 38 M&L Pop Up Impact Rotor Sprinkler Of Radius Not Less Than 18 Mtr Colour In Grey Recommended Discharge Rate Of 0.9 Lps And Pressure Rating Of 4 Kg / Sqcmadjustable From 2 Degree To 360 Degree Suitable Including Swing Joint And Service Saddle Of Suitable Size Complete All As Specified & Directed. 39 S&F Pvc Body Control Valve Of Size 63Mm Dia Having Maximum Operating Pressure 10 Kg / Sqcm And Flow Rate Of 3400Lpm @ Pressure Rating Of 1 Kg / Sqcm With Teflon Seal, Isi Marked, With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 40 S&F Pvc Body Flush Valve Of Size 50Mm Dia Having Maximum Operating Pressure 6Kg / Sqcm, Isi Marked, With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 41 S&F Pvc End Cap ( Plain ) Of Size 50Mm Dia Having Maximum Operating Pressure 6Kg / Sqcm, Isi Marked, With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 42 S&F Cast Iron Non Return Valve Of Size 65Mm Dia As Per Is:1538 Suitable For Pressure 10 Kg / Sqcm With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 43 S&F Pvc Body Automatic Air Cum Vaccum Release Valve Of Size 32Mm Having Maximum Operating Pressure 10Kg / Sqcm And Minimum Sealing Pressure 0.30Kg / Sqcm, Isi Marked, With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 44 S&F Pvc Body Pressure Relief Valve Of Size 63Mm Dia Having Maximum Operating Pressure 10Kg / Sqcm, Isi Marked, With Bolts, Nuts, Rubber Insertion Sheet Etc Complete All As Specified & Directed. 45 S&F Hdpe Irrigation Ball Valve Box Snap Fit Type Having Pipe Access Hole Of 65Mm And Dimensions 250Mm ( Top ) , 274Mm ( Lid ) , 347Mm ( Base ) And 250Mm ( Height ) , Isi Marked, Complete All As Specified & Directed. 46 S&F Hdpe, Double Layer, Water Storage Tank Of Capacity 5000Ltrs Approved Quality Complete Including Necessary Fittings And Tank Nipple For Interconnection Of Tanks Complete All As Specified & Directed. Note: Pcc Foundation For Water Tank Shall Be Measured & Paid Separetely. 47 S&F Monoblock Pumpset Having Discharge And Head Rating Not Less Than 3.60 Lps And58 Mtr Respectivelyand Outlet Dia Of 80Mm Bore Including Motor Of Suitable Capacity Alongwith Suitable Starter Panel Including Cable From Starter Panel To Motor To Run On 415 Volts, 3 Phase, 50 Hz Cycles A / C Power Supply Complete With Other Accessories As Required Complete All As Specified & Directed. Notes For Boq Item No 32.00 To 47.00 :- ( I ) Work To Be Carried Out Through A Approved Vendor / Oem Having Working Experience In Execution Of Irrigation / Arboriculture Work In Govt Departments. Proof Of Experience Shall Be Submitted By The Contractor And Vendor / Oem Shall Got Approved By Ge Before Commencement Of Work. ( Ii ) After Execution, Complete Water Supply System ( Boq Item No. 32.00 To 47.00 ) Shall Be Tested By Representative Of Accepting Officer For Its Functionality As & When Requested By Contractor Through Ge. 48 Supply, Laying, Jointing, Testing And Commissioning Of Lt Electric Cable, 1100 Volts Grade, Heavy Duty, Xlpeinsulated, Armoured Electric Power Cable With Aluminium Conductor Of Cross Sectional Area 25Sqmm, 4 Core Conforming To Is- 7098 ( Part I ) 1988 Laid As In Trenches Or Fixed Along The Wall / Pole Or Passing Through Pipes / Ducts Etc, Complete All As Specified & Directed. 49 Taking Down / Out Old Unservieable Sprikler Any Type / Size Complete All As Specified & Directed. 50 M&L Consolidated Broken Stone Or Boulders Hardcore Of Gauge Not Exceeding 63Mm, Deposited, Spread And Levelled In Layers Not Exceeding 15Cm Thick Each, Watered And Rammed To A True Surfacecomplete All As Specified & Directed. 51 M&L Brick Work With Sub Class B, Burnt Clay Bricks Of Old Size, Designation 75, Curved On Plan Dia 2.5Mtr As In Foundation, Built In Cement Mortar 1:6 Complete All As Specified & Directed. 52 For Credit Schedule, Refer Tender Documents. The Amount Of Credit Schedule Shall Be Deducted From Total Quoted Amount Of Boq To Arrive Contract Sum.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Sep-2023 CWE/AF AMB/SAR-10/2023-24 Amendment in BOQ Other 12-09-2023
2 12-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 91000.0 /-
Tender Value
INR 45.50 Lakhs /-

BOQ Items

NAME OF WORK : SPECIAL REPAIR / REPLACEMENT CONVERSION OF HT OH LINE TO UG LINE AND WATER SUPPLY SYSTEMAF STN SARSAWA UNDER GE (AF) SARSAWA
Sl. No. Item Description
1M&L earthing complete with galvanized steel earth plate 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32mm x 6mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point& earth dolly including watering pipe GI 20 mm boremedium grade 2.5 mtr long including protection pipe GI medium grade 40mm bore 7.5 mtr long, wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:3:6 type C-1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 40 mm thick reinforced with 8 mm dia TMT bars @ 15cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I, including testing on completion on site complete all as specified & directed. Notes :- Any variation in length of earth lead and protection pipe of earth lead shall be measured & paid seperately. On testing if the earth resistance is not obtained, earthing will be generated at no extra cost, till the desired earth resistance is obtained. The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
2S&F 32mm x 6 mm galvanized iron strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. as requiredcomplete all as specified & directed
3Supply, laying, jointing, testing and commissioning HT XLPE cable(heavy duty), 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size cross sectional area 95 Sqmm, 3 core, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc complete all as specified & directed. Notes: (i) Cable shall be of manufacturing date not earlier than May 2023. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii)Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measuredand paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record. (v) Cable shall be tested in the presence of Rep of Accepting officer at factory premises prior to despatch.
4Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose soil complete all as specified & directed.
5Excavation in trenches, not exceeding1.5mtr wide and exceeding 1.5mtr but not exceeding 3.0mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose soil complete all as specified & directed.
6Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick each in soft/loose soil complete all as specified & directed.
7Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
8Supply & laying un-reinforced precast concrete cable cover , Class HV type-1 flat, size 300mm x 180mm x 40mm, laid flatfor protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
9M&LSand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmdeep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed.
10S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed.
11Dismantling of steel tubular poles, strut any size complete all as specified & directed.
12Dismantling of insulators any type, any size complete all as specified & directed.
13Dismantling of ACSR or AAC overhead conductors complete all as specified & directed.
14Dismantling of cross-arms of MS channel or angle sections etc. complete all as specified & directed.
15M&L true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP 55, 11 metre long complete with mild steel base plate of 6 mm thick of size 300mm X 300mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminious paint for embeded portionin concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole complete all as specified & directed. Note:-Excavation, earth workandPCCshall be measured and paid separately.
16M&L PCC 1:4:8, type D2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
17M&L PCC 1:3:6, type C2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
18M&L PCC 1:2:4, type B1, using 20mm graded mechanically crushed stone aggregate as in copping of poles/stay/panel including formwork for fair surface complete all as specified & directed.
19S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of synthetic enamel paintover & including one coat of redoxide oxide primer complete all as specified & directed.
20S&F anti climbing device, spikes type fabricated out of MS bars , round square and flat with and including providing required nuts , bolts, washers etc., welding in two halves, made to shape, to suit the cross section of the pole and applying two coats of aluminium paint over & including one coat of zinc oxide complete all as specified & directed.
21S&F HT lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 11000 volts, transmission class, discharge capacity 10 Kiloampere complete all as specified & directed.
22M&L for augering upto 100mm bore for road crossing 3 mtr to 10 mtr(in length) not exceeding 1.5 mtr in depth in soft/loose soil for laying of electric cable and GI tubing etc. complete all as specified.
23Supply, installation & testing of Switch Air break gang operated, triple pole, for horizontal or vertical operation, mechanically operated, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, medium grade GI pipe from ground level with locking arrangements, 200 Amps rating 11000 volts working pressure including making electrical connectionsto make it functional after testing complete all as specified & directed.
24S&F cable route indicator, showing "MES HT" under ground cable" and arrow mark painted with two coat synthetic enamel paint over & including one coat of zinc oxide primer, made out of MS plate of size 200mm x 200mm, 6mm thick fixed on MS flat of size 25mm x 4mm, 600mm long, including cutting, chasing, drilling, welding etc.(whichever required) and embedded in PCC block 1:3:6, type C-2 of size 30cm x 30cm x 30cm in the ground including excavation and earth work complete all as specified & directed. Note: Excavation & earthwork and PCC work included in quoted rates.
25M&L double wall corrugated (DWC) HDPE pipe outer dia 90mm & inner dia 75mm, confirming to IS 4984 with end cap as in trenches/under road/under floor including cutting road/floor and making good wherever necessary or fixed to wall/pole with fixing arrangement with suitable size of MS clamps made from flat iron including nuts, bolts & washers for cable protection complete all as specified & directed. Note: Excavation for trenches shall be measured & paid seperately. The working/installation of pipe shall be confirming to IS 14930
26M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS clamps, bolts and nuts, for HT of 25cm x 20cm size as per SSR Part-I dully painted with two coats of aluminium paint complete all as specified & directed.
27S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
28M&L earthing complete with galvanized steel earth plate 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead wire 4.00mm dia upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point& earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 15mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:3:6 type C-1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 40 mm thick reinforced with 8 mm dia TMT bars @ 15cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I, including testing on completion on site complete all as specified & directed. Notes :- Any variation in length of earth lead and protection pipe of earth lead shall be measured & paid seperately. On testing if the earth resistance is not obtained, earthing will be generated at no extra cost ,till the desired earth resistance is obtained. The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
29S&F 4.0mm dia galvanized iron wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. as requiredcomplete all as specified & directed
30Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in hard/dense soil complete all as specified & directed.
31Supply and laying old size, common burnt clay, sub class "B" bricks, designation 75, laid flat & dryfor protection of electric cable in trenches, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
32Taking up or down old unserviceable PVC water tubing of any type and any size from trenches or walls etc. complete all as specified & directed.
33M&L HDPE Pipe PE 100, SDR-17, DN (nominal OD) 50mm, PN-6, confirming to IS 4984:2016(Reaffirmed 2021) with all fittings, laid in trenches/floor or fixed in wall complete all as specified & directed.
34M&L HDPE Pipe PE 100, SDR-17, DN (nominal OD) 63mm, PN-6, confirming to IS 4984:2016(Reaffirmed 2021) with all fittings, laid in trenches/floor or fixed in wall complete all as specified & directed.
35M&L HDPE Pipe PE 100, SDR-13.6, DN (nominal OD) 75mm, PN-8, confirming to IS 4984:2016(Reaffirmed 2021) with all fittings, laid in trenches/floor or fixed in wall complete all as specified & directed. Note for BOQ item No. 33.00 to 35.00: Excavation and Earthwork shall be measured & paid separetely.
36S&F Vertical High Efficiency Filter of nominal dia minimum 50mm at inlet and outlet with nominal dia of minimum 40mm at backwash/bypass having maximum pressure rating not less than 10 kg/sqcm,nominal opertating pressure 6 kg/sqcm, Nominal flow rate 20 cum/hr, flow rate of 101 cum/hr/sqm, backwash flow rate of 8 cum/hr, quantity of media 120 kg, filter media should be of high quality silica sand duly crushed silica sand/quartz gravel of particle size 1 mm to 2 mm (0.039 inch to 0.078 inch), Minimum gross weight not less then 67 Kg including all nuts bolts etc fixing arrangment required at site to fix the hydrocyclone filter complete all as specified & directed. Note: The testing of filter shall be done in presence of GE and test report shall be submitted to rep of Accepting officer.
37S&F Disc clean "L" filter having nominal flow rate of 25 cum per hr nominal size 63 mm, nominal pressure 6 kg/sqm and size of aperture 100 mesh including all fixing arrangement required at site to fix the vertical high Efficiency filter complete all as specified & directed.
38M&L pop up impact rotor sprinkler of radius not less than 18 mtr colour in grey recommended discharge rate of 0.9 lps and pressure rating of 4 kg/sqcmadjustable from 2 degree to 360 degree suitable including swing joint and service saddle of suitable size complete all as specified & directed.
39S&F PVC body control valve of size 63mm dia having maximum operating pressure 10 kg/Sqcm and flow rate of 3400LPM @ pressure rating of 1 kg/Sqcm with Teflon seal, ISI marked, with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
40S&F PVC body flush valve of size 50mm dia having maximum operating pressure 6kg/Sqcm, ISI marked, with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
41S&F PVC end cap (Plain) of size 50mm dia having maximum operating pressure 6kg/Sqcm, ISI marked, with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
42S&F cast iron non return valve of size 65mm dia as per IS:1538 suitable for pressure 10 kg/Sqcm with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
43S&F PVC body automatic air cum vaccum release valve of size 32mm having maximum operating pressure 10kg/Sqcm and minimum sealing pressure 0.30Kg/Sqcm, ISI marked, with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
44S&F PVC body pressure relief valve of size 63mm dia having maximum operating pressure 10kg/Sqcm, ISI marked, with bolts, nuts, rubber insertion sheet etc complete all as specified & directed.
45S&F HDPE irrigation ball valve box snap fit type having pipe access hole of 65mm and dimensions 250mm (top), 274mm (Lid), 347mm (Base) and 250mm (height), ISI marked, complete all as specified & directed.
46S&F HDPE, double layer, water storage tank of capacity 5000Ltrs approved quality complete including necessary fittings and tank nipple for interconnection of tanks complete all as specified & directed. Note: PCC foundation for water tank shall be measured & paid separetely.
47S&F monoblock pumpset having discharge and head rating not less than 3.60 LPS and58 mtr respectivelyand outlet dia of 80mm bore including motor of suitable capacity alongwith suitable starter panel including cable from starter panel to motor to run on 415 volts, 3 phase, 50 Hz cycles A/C power supply complete with other accessories as required complete all as specified & directed. Notes for BOQ item No 32.00 to 47.00 :- (i) Work to be carried out through a approved vendor/OEM having working experience in execution of irrigation/arboriculture work in Govt departments. Proof of experience shall be submitted by the contractor and vendor/OEM shall got approved by GE before commencement of work. (ii) After execution, complete water supply system (BOQ item No. 32.00 to 47.00) shall be tested by representative of Accepting Officer for its functionality as & when requested by contractor through GE.
48Supply, laying, jointing, testing and commissioning of LT electric cable,1100 Volts grade, heavy duty,XLPEinsulated, armoured electric power cable with aluminium conductor of cross sectional area 25sqmm, 4 core conforming to IS- 7098 (Part I) 1988 laid as in trenches or fixed along the wall/pole or passing through pipes/ducts etc, complete all as specified & directed.
49Taking down/out old unservieable sprikler any type/size complete all as specified & directed.
50M&L consolidated broken stone or boulders hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick each, watered and rammed to a true surfacecomplete all as specified & directed.
51M&L Brick work with sub class B, burnt clay bricks of old size, designation 75, curved on plan dia 2.5mtr as in foundation, built in cement mortar 1:6 complete all as specified & directed.
52For Credit Schedule, refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail