Public Health Engineering Department-PHED has published Tender For Providing And Installation Of Pumping Machineries And Other Electromechanical Accessories For Augmentation Works For Piped Water Supply Scheme For Phulberia And Its Adjoining Mouzas Under Jal Jeevan Mission Programme Under Bmd, Phed.. Submission Date for this Tender is 15-09-2023. Electromechanical Machinery Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | PART-A ( At CWR Site) |
2 | Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE3star(minimum) rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category Bmotor) as per NIT |
3 | a) Discharge-30 M3/Hour, Total head -48 Mtr |
4 | Supply, delivery and storage at site 80 mm dia UPVC Column pipe medium gauge both side 8 TPI threaded and one side heavy type socket other site rubber cap for threaded protector Standard (17kg/cm2). |
5 | i) 1.5 mtr long |
6 | ii) 3 mtr long |
7 | Supply and delivery at site 80 mm dia CI Top Adaptor with flange (Single clamp) |
8 | Supply and delivery at site 80 mm dia CI Bottom Adaptor(Single clamp) |
9 | Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland |
10 | 102mm ? 0-12 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings |
11 | Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mm dia pipe (Size-300 mm x 80 mm x 8 mm each) |
12 | Supply and delivery of 80mm diafollowing GI specials for delivery line |
13 | Tee |
14 | Pipe (TATA Medium) (including Socket) |
15 | Bend (90") |
16 | Flange (G.I Threaded)heavy type |
17 | Plug |
18 | Socket |
19 | Supply and delivery of 32mm diafollowing GI specials for Cable Protection |
20 | 100mm long short piece |
21 | Bend (90") |
22 | Union |
23 | Pipe (TATA Medium) (including Socket) |
24 | Supply, delivery of clear water Open well Submersible Pump, with Bronze Impeller (Heavy Duty Pump). potable clear cold water and BEE 4 Star Rated motor and suitable for operation in AC Three phases 415V,50Hz (category B motor) Suction and Delivery size 50/50mm N.B- H-Q curve has to be submitted during the delivery (1W+1S) |
25 | a) Discharge-30M3/Hr, Total head -44Mtr |
26 | Supply & delivery at site following Valves |
27 | Supply & delivery at site & storage CIDF single door swing checkNRV (P.N.–1.0) rating asper IS:5312 Part – I, and as per technical Specifications given in NIT (for individual L/L Pump) |
28 | i) DN 80 mm(for Submersible delivery header) |
29 | ii) DN 80 mm(for H/L individiual delivery header) |
30 | CIDFnon-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846as per technical Specification given in NIT |
31 | i) DN – 80mm (for H/LCommon delivery header) |
32 | ii) DN – 80mm (for L/L wash out line) |
33 | Supply and delivery ofthree phase actuator operated wafer type butterfly valve (PN-1.0) as per Bs-5155and as per technical Specification given in NIT |
34 | i) DN 80 mm (for L/L & H/L individual delivery header) |
35 | Supply, delivery & storage and installation at site M.S fabricated dismantling joints (P.N–1.0) with rubber compression ring and adjustable follower flanged complete assembley with galvinised stud and nuts,as per technical Specifications given in NIT |
36 | i) DN:80mm (for Commn delivery header ) |
37 | ii) DN:80mm(for H/L individual delivery line ) |
38 | Supply, delivery & storage at site M,S Pipesfor individual pumpdelivery line from pump discharge upto common delivery header, M.S flanges, bends, specials, etc. as required to make the installation ofdelivery and common delivery header of pumpingmachineries complete in all respects up to the satisfaction of E.I.C.and as per technical Specifications given in NIT |
39 | Supply delivery and storage at site of Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicatoras per technical specification |
40 | i) DN: 80 (for H/L Common Header header) |
41 | Supply, delivery & storage ofGleeserine type pressure gauge,cast Al. dial along with DN-15 GI impulse line with valve. |
42 | i) (0 – 10 Kg.) 102 mm dia for individiual delivery header |
43 | ii) (0 – 10 Kg.) 150 mm ? for Common Header |
44 | Supply, delivery and storage at site of following L.T cables |
45 | 35 Sq. mm3.5 core, 1.1 KV grade, Al. Ar XLPE cable conforming to IS : 7098 (Part – I). From Meter to PDB cum MCC throught Voltage Stabiliser |
46 | 10 Sq. mm 3 core, 1.1 KV grade, Al. Ar, XLPEAcable conforming to IS : 7098 (Part – I). 1) 1nos Sub mersible motor to starter 2nos x 100mtr =200 mtr |
47 | 2.5 Sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date. a) 1nos Kiox box to submersible Motorx 80mtr =80 mtr b) H/L Motor40 x 2nos = 80 mtr |
48 | 1.5 sq mm , 12 core , 1.1 KVGrade PVC insulatedCopper Armoured control cable as per relevent IS. i) For H/L 2nos actuater x 15 mtr= 30 mtr ii) For H/L 1nos actuater x 100 mtr= 100 mtr |
49 | 6 Sq. mm 4 core, 1.1 KV grade, Al. Ar, XLPEAcable conforming to IS : 7098 (Part – I). For MCC to Chlorine machine |
50 | N.B-Purchase of all cables should be as per actual site requrement |
51 | Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt PDB cum MCC Panelhaving required Feedersas per technical Specifications given in NIT |
52 | Supplying delivery of 160 Amps 415 Volt TPN Sheet steelenclosed HBC Fuse type Heavy Duty Double Break Main Switche with Sidet handle operated For receiving WBSEDCL power |
53 | Supply delivery and storage at site of Ultrasonic type continuous level measuring unit with provision of 4 to 20 mA analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low - low level in suction sumpas per technical Specifications given in NIT |
54 | Supply, delivery and storage at site of automatically controlled Plunger type chlorinator dosing pump with Flow Rate 100 Ltr./Hr. and Max pressure of 10kg/cm2) with all accessoriesfor pump motor, foundation Bolt, suction and discharge flange and with storage tank of dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1450 RPM squirrel cage TEFC induction Motor, Motor will be IE3 (Make of Machine: As per attached vendor list of P.H.E Dte.) |
55 | Supplyand delivery30KVA Oil Coolling type Voltage Stabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NIT N.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery |
56 | Supply and delivery of 450mm(H) x 300(L) x 250mm(B) size out door CRCA sheet steelfabricated cubical type kenopy top cable jointing box inside fitted3 nos 100 Amp rated bus bar andhinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C |
57 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). a) 40 mm dia [ forCable protection] for L/L & H/L site |
58 | PART-B ( Intallation) |
59 | Installation and commissioningof all items mentioned as in PART A (Exepet item no-18.2,18.4 and22) including supply of all erection items,as required for installation ofpumping machineris , all valves, delivery pipe line, PDB cum MCC panel, Voltage Stabiliser, indoor & outdoor light,laying of cable on cable tray includingsupplying all necessary items i.e- nut & bolt wather rubber gasket, with painting, jointing of cables termination cable soketing by suitable rated sockets, jointing the delivery header with H/L & L/L rising main, suporting piller and paining anticorrosive paint etc. including cost ofgas cutting, welding etc. as required for complete the installationas per Hydraulic standard & IE rules in compliance by engaging skilled technician all complete as per Technical specificationand upto entire satisfaction of EIC. |
60 | Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire(approved make) from installed panel board through 20mm size PVC rigid conduct FR(Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine) |
61 | Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed |
62 | Laying of 1.5Sq mm controll cable through 40 mm dia PVC Schedule-80 pipe in under ground trench, the trench size : 500 mm(W) x 760 mm(D) average depthand also trench to be filled up with shifted soil, levelling up and restoring surface duly rammedas per direction of EIC |
63 | Earthingwith 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.incl GI bolts, double nuts, double washers . GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and size86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside)and CI hinged inspection cover of 36.56 cm x 35.56 cm with locking arrangement, and connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised strip By ISI-Medium GI pipe as per NIT Specification |
64 | i) For MCC & Voltage Stabiliser-2set |
65 | ii) For Cable jointingbox- 1set |
66 | Internal luminaries arrangement at the Pump House and bathroom including internal wiring etc. as per technical Specifications given in NIT |
67 | Supply delivery and installation at site and storage of safety equipment like 6kg capacity Fire Extinguisher , sand bucket with bracket , rubber mats, shock treatment chart and first aid box, complete as per technical Specifications given in NIT |
68 | Cost of supply and delivery at site of calcium hypochlorite granule minimum CI content 60%-65% in air plastic jar (3kg each) as per direction of EIC. (Make PHE approved) |
69 | Supply and delivery of 2(Two) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT |
70 | Yard lighting for OHR site |
71 | Supply & Installation of Solar Module- 75 WP ( ERTL and Flash Tested) I. The PV module shall contain crystalline silicon solar cells and must have a certificate of testing conforming to IEC 61215 Edition II. The power output of the module(s) under STC would be a minimum of 100 Wp at a load voltage* of 18.83 ± 0.2 V III. The open circuit voltage* of the PV modules under STC would be 22.0 Volts IV. The module efficiency would be 15% V. SPV module shall be highly reliable, lightweight and shall have a service life of more than 25 years. SPV modules shall have a limited power loss of not more than 10% of nominal output at the end of 10 years and not more than 20% at the end of 25 years VII. The solar module shall be able to withstand the following environmental conditions normally encountered at site – Temp. extremes ranging from -100 C to +850 C Wind load – 150 km/h Maximum mean hourly rainfall of 40mm Humidity level upto 95%, VIII. Strip must contain the following details a) Name of Manufacturer b) Model or type number c) Serial No. d) Year of make BIS/ MNRE Approved 75Wp x 6nos pole= 450Wp |
72 | Supply Installation of 12 w LED- White light Emitting Diode (W-LED) 12Watt (LED + Driver) -Colour temperature of White LED used in the system should be in the range of 5500k-6500k- Lumen efficacy of LED min 100 Lumens/Watt 18watt |
73 | Supply Installtion of LiFePo4 Battery Minimum 12.8 v 30Ah LiFePo4 Battery at STC back up for 18-20 hrs BIS Approved |
74 | Inbuilt Charge Control Units and other Electrinics supporting to Dimming facitiites after 5 hrs & after 5 hrs 50% lighting, Dusk to Dawn facitlities PWM/ MPPT type -Maximum Power Point Tracking , Charge controller Rating @ Related Voltage minimum 10 amp, Average Duty Cysle - Dsuk to Dawn |
75 | Supply, Erection and Commissioning of G.I. Octagonal - Approx 5meter Above the Ground, Mounted at Pole I. A corrosion resistant metallic frame structure must be fixed on the pole to hold the SPV module. II. The frame structure must have provision to adjust its angle of inclination to the horizontal between 0 and 45, so that the module can beoriented at the specified tilt angle. III. Pole height: Mtr. (Dia = 120 mm X 70 mm) With baseplate grounding facility (Corrosion resistance) & 3 mm thickness IV. Base Plate 280OD X 8MM with M16 x L450 Foundation Bolt. V. Pole must be 80 Micron Hot Deep Galvanized ( GI ) |
76 | Cable & Lugs 2 Core 2.5 Sq.mm for battery charging & 2 Core 1.5 Sq.mm for load Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694 and others & Lugs as per requirement |
77 | Earth work in excavation of foundation trenches or drain in all sorts of soil( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
78 | Erection of Singletubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly |
79 | Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole |
80 | PART-C for H/Wsite |
81 | Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEErated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category Bmotor) as per NIT |
82 | a) Discharge-22 M3/Hour, Total head -22 Mtr |
83 | Supply, delivery and storage at site 80 mm dia M.S. E.R.W. column pipe, 4.85 mm thickness with both end threaded including one socket and threaded protector painted with anti corrosive paint |
84 | a) 1.5 Mtr. Long |
85 | b) 3.05 Mtr. Long |
86 | Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mm dia pipe (Size-300 mm x 80 mm x 8 mm each) |
87 | Supply, Delivery and storage at site of Horizantal Split cashing CentrifugalPumping Machinarywith base plate flexible coupllng, coupling guard, foundation bolt etc. other Accessories etc. having the following specification and as per technical Specifications given in NIT N.B- H-Q curve has to be submitted during the delivery |
88 | a) Discharge : 45 M3/Hr, Total Head : 50 mtrs. |
89 | b) Discharge : 42.9 M3/Hr, Total Head : 31 mtrs. |
90 | Supply, Delivery and Storage at site of suitable capacity Horizontal Foot Mounted solid shaft Induction Motor (IE 4 type) suitable for the pump duty mentioned above with adequate margin as per detail technical specification given in NIT. N.B-No load as well as short-circuit Test Certificate of induction motor during test run has to be submitted during the delivery. |
91 | a) For Pump Motor Set-I |
92 | b) For Pump Motor Set-II |
93 | Supply & delivery at site following Valves |
94 | Supply & delivery at site & storage CIDF single door swing checkNRV (P.N.–1.0) rating asper IS:5312 Part – I, and as per technical Specifications given in NIT (for individual L/L Pump) |
95 | i) DN 80 mm(for Submersible delivery header) |
96 | ii) DN 80 mm(for H/L Set-I individiual delivery header) |
97 | iii) DN 80 mm (for H/L Set-II individual delivery header) |
98 | CIDFnon-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846as per technical Specification given in NIT |
99 | i) DN – 100mm (for H/L Set-ISuction Line ) |
100 | ii) DN 80 mm(for H/L Set-II individiual Suction Line & common delivery line) |
101 | ii) DN – 100mm (for common Set-Idelivery line ) |
102 | Supply and delivery ofthree phase actuator operatedwafer type butterfly valve (PN-1.0) as per Bs-5155and as per technical Specification given in NIT |
103 | i) DN 80 mm (for H/L Set-I individual delivery header) |
104 | i) DN 80 mm (for H/L Set-IIindividual delivery header) |
105 | Supply delvery at site and storage of Ductile iron Tamper Proof Single Orifice Air Release Valve of DN 50 as per relevanl lS Standard |
106 | i)DN 50 for H/L Commn delivery header) |
107 | Supply, delivery & storage at site M.S. fabricated dismantling joints (P.N–1.0) with rubber compression ring and adjustable follower flanged complete assembley with galvinised stud and nuts,as per technical Specifications given in NIT |
108 | i) DN:100 mm (for H/L Set-I Suction line) |
109 | ii) DN:100mm(for H/L Set-I Commn delivery header ) |
110 | iii) DN: 80 mm(for H/L Set-Idelivery header ) |
111 | iv) DN:100 mm (for H/L Set-II Suction line) |
112 | v) DN: 80mm (for H/L Set-II delivery & Commn delivery header ) |
113 | Supply, delivery & storage at site M,S Pipesfor individual pump delivery line from pump discharge upto common delivery header, M.S flanges, bends, specials, etc. as required to make the installation ofdelivery and common delivery header of pumpingmachineries complete in all respects up to the satisfaction of E.I.C.and as per technical Specifications given in NIT |
114 | i) For H/L Set-I |
115 | ii) For H/L Set-II |
116 | Supply delivery and storage at site of Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicatoras per technical specification |
117 | i) DN:100mm dia For H/L Set-I |
118 | ii) DN:80mm dia For H/L Set-II |
119 | Supply, delivery & storage ofGleeserine type pressure gauge,cast Al. dial along with DN-15 GI impulse line with valve. |
120 | i) (0 – 10Kg.) 102 mm dia for individiual delivery header |
121 | ii) (0 – 10Kg.) 150 mm ? for Common Header |
122 | Supply, delivery & storage ofGleeserine type Compound gauge, cast Al. dial along with DN-15 GI impulse line with valve. |
123 | i) (+1 – 1 Kg.) 102 mm ? for individiual Suction line |
124 | Supply, delivery and storage at site of following L.T cables |
125 | 120 Sq. mm x 2 nos 3.5 core, 1.1 KV grade, Al. XLPE cable conforming to IS : 7098 (Part – I). From Main Switch to PDB cum MCC |
126 | 25 Sq. mm 3 core, 1.1 KV grade, Al. XLPEAcable conforming to IS : 7098 (Part – I). a) 2nos motor Set-I x 20mtr =40 mtr |
127 | 16 Sq. mm 3 core, 1.1 KV grade, Al. XLPEAcable conforming to IS : 7098 (Part – I). a) 2nos motor Set-II x 20mtr =40 mtr |
128 | 10 Sq. mm 3 core, 1.1 KV grade, Al. XLPEAcable conforming to IS : 7098 (Part – I).. a) 5nos Sub mersible motor x 400mtr =2000 mtr |
129 | 1.5 sq mm , 12 core , 1.1 KVGrade PVC insulatedCopper Armoured control cable as per relevent IS. a) For 2nos actuater Pump set-I x 10 mtr =20mtr b) For 2nos actuater Pump set-II x 10 mtr =20mtr |
130 | 6 Sq. mm 4 core, 1.1 KV grade, Al. XLPEAcable conforming to IS : 7098 (Part – I). For MCC to Chlorine machine |
131 | N.B-Purchase of all cables should be as per actual site requrement |
132 | Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt PDB cum MCC Panelhaving required Feedersas per technical Specifications given in NIT |
133 | Supply delivery and storage at site of Ultrasonic type continuous level measuring unit with provision of 4 to 20 mA analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low - low level in suction sumpas per technical Specifications given in NIT |
134 | Supply, delivery and storage at site of automatically controlled Plunger type chlorinator dosing pump with Flow Rate 100 Ltr./Hr. and Max pressure of 10kg/cm2) with all accessoriesfor pump motor, foundation Bolt, suction and discharge flange and with storage tank of dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1450 RPM squirrel cage TEFC induction Motor, Motor will be IE3 (Make of Machine: As per attached vendor list of P.H.E Dte.) |
135 | Supplyand delivery100 KVA Oil Coolling type Voltage Stabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NIT N.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery |
136 | Supply & delivery at site horizontal type centrifugal self priming non-clog dewatering pump with horizontal type 415V ,50 Hz , three phase squirrel cage Induction motor including supply of channel base frame ,coupling and coupling guard complete set Discharge capacity : 5.75 M3/hr Total Head : 10 mtr. Suction/delivery- 40mm/35mm |
137 | Supply and delivery at site 40mm dia G.I pipe. With fittings i.e- Elbow, Union, Nipple. G.M Ball valve. C.I Foot valve etc for making suction and delivery line for 2(Two) nos dewatering pump. |
138 | PART-B(Intallation for H/W site) |
139 | Dismantling and taken out charges of Centrifugal Pumping machineries, MCC Panel , Voltage Stabiliser, Chlorine machine and as necessary by engaging manual labour as per direction of EIC |
140 | Installation of all items mentioned as in PART C (Exepet item no-11(iv) and 14) including supply of all erection items,as required for installation of Submersible pumping machineris & Centrifugal pumping machineris by the suitable Joist structure, all valves, delivery pipe line, PDB cum MCC panel, Chlorine system, cable tray, indoor & outdoor light, laying of cable on cable tray includingsupplying all necessary items i.e- nut & bolt wather rubber gasket, with painting, jointing of cables termination cable soketing by suitable rated sockets, jointing the delivery header with rising main, suporting piller and paining anticorrosive paint etc. including cost ofgas cutting, welding etc. as required for complete the installationas per Hydraulic standard & IE rules in compliance by engaging skilled technician all complete as per Technical specificationand upto entire satisfaction of EIC. |
141 | Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire(approved make) from installed panel board through 20mm size PVC rigid conduct FR(Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine) |
142 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. size of the trenches (W-600mm, D-750mm L-200mtr) |
143 | Laying of5 nos x 10 sq mm Al, Ar cable in an underground trench in single tier formation (horizontal), the trench size : W-1000 mm x 750 mm average depth, (ordinery without brick protection)minimum 200mm gap in between two cablealso trench to be filled up with shifted soil, levelling up and restoring surface duly rammed as per direction of E.I.C [200 mtr x 5nos = 1800mtr] |
144 | Laying ofAl Ar cable through with fixing & laying of Cable along the lenth of River Bed 150mm dia GI delivery pipe line by the above supplyedM.S Clamp and G.I Wire as per direction of E.I.C a) 10 Sqmm 3 Core Al, Ar Cable |
145 | Supply, delivery Fixing at siteG.I cable tray for laying of power cable and G.I Perforated cable tray for laying of control cable at Pump House having proper M.S. structural supportas per technical Specifications given in NIT |
146 | Earthing & lightning protection for Pump House, electrical installation as per ISS and IE rules andas per technical Specifications given in NIT (2 nos Earth pitfor each intallation) |
147 | Earthing of cable jointingbox with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.incl GI bolts, double nuts, double washers . GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and size86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside)and CI hinged inspection cover of 36.56 cm x 35.56 cm with locking arrangement, and connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised strip By ISI-Medium GI pipe |
148 | Lighting and luminaries arrangement at the head works site including internal illumination ofpump house building. as per technical Specifications given in NIT |
149 | Supply delivery at site and storage of safety equipment like 6kg capacity Fire Extinguisher , sand bucket with bracket , rubber mats, shock treatment chart and first aid box, complete as per technical Specifications given in NIT |
150 | Supply and delivery of 4(four) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT |
151 | Carrying charges for unserviceable matrials from Phulberia water supply schemeto Bankura Mechanical Division Ahilakundi with loading and unloading as per direction |
152 | Yard lighting for H/W site |
153 | Supply & Installation of Solar Module-75 WP ( ERTL and Flash Tested) I. The PV module shall contain crystalline silicon solar cells and must have a certificate of testing conforming to IEC 61215 Edition II. The power output of the module(s) under STC would be a minimum of 100 Wp at a load voltage* of 18.83 ± 0.2 V III. The open circuit voltage* of the PV modules under STC would be 22.0 Volts IV. The module efficiency would be 15% V. SPV module shall be highly reliable, lightweight and shall have aservice life of more than 25 years. SPV modules shall have a limited power loss of not more than 10% of nominal output at the end of 10 years and not more than 20% at the end of 25 years VII. The solar module shall be able to withstand the following environmental conditions normally encountered at site – Temp. extremes ranging from -100 C to +850 C Wind load – 150 km/h Maximum mean hourly rainfall of 40mm Humidity level upto 95%, VIII. Strip must contain the following details a) Name of Manufacturer b) Model or type number c) Serial No. d) Year of make BIS/ MNRE Approved 75Wp x 4nos pole= 300Wp |
154 | Supply Installation of 12 w LED- White light Emitting Diode (W-LED) 12Watt (LED + Driver) -Colour temperature of White LED used in the system should be in the range of 5500k-6500k- Lumen efficacy of LED min 100 Lumens/Watt 18watt |
155 | Supply Installtion of LiFePo4 Battery Minimum 12.8 v 30Ah LiFePo4 Battery at STC back up for 18-20 hrs BIS Approved |
156 | Inbuilt Charge Control Units and other Electrinics supporting to Dimming facitiites after 5 hrs & after 5 hrs 50% lighting, Dusk to Dawn facitlities PWM/ MPPT type -Maximum Power Point Tracking , Charge controller Rating @ Related Voltage minimum 10 amp, Average Duty Cysle - Dsuk to Dawn |
157 | Supply, Erection and Commissioning of G.I. Octagonal - Approx 5 meter Above the Ground, Mounted at Pole I. A corrosion resistant metallic frame structure must be fixed on the pole to hold the SPV module. II. The frame structure must have provision to adjust its angle of inclination to the horizontal between 0 and 45, so that the module can beoriented at the specified tilt angle. III. Pole height: Mtr. (Dia = 120 mm X 70 mm) With baseplate grounding facility (Corrosion resistance) & 3 mm thickness IV. Base Plate 280OD X 8MM with M16 x L450 Foundation Bolt. V. Pole must be 80 Micron Hot Deep Galvanized ( GI ) |
158 | Cable & Lugs 2 Core 2.5 Sq.mm for battery charging & 2 Core 1.5 Sq.mm for load Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694 and others & Lugs as per requirement |
159 | Earth work in excavation of foundation trenches or drain in all sorts of soil( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
160 | Erection of Singletubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly |
161 | Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole |
162 | Add: 18% GST |
163 | Add: 1% Cess |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy