| 1 | PART-A 11KV LINE LENGTH WITH 50 MTR SPAN USING 55 SQ. MM-AAA CONDUCTOR WPB 160x152 (11 Mtr Long, 30.44 KG/Mtr) |
| 2 | Straight Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 1.2 mtr, 2 no\"s channel required =(2x9.56x1.2) |
| 3 | Fish plate 50x6 mm., 2.36kg/mtr., each 0.280 mtr. Length, 8no\"s required(8x2.36x0.28) |
| 4 | Straight Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 0.306 mtr,4 no\"s channel required |
| 5 | Danger Plate 2 No\"s |
| 6 | Back Clamp for danger plate 25x3 mm. flat, 0.59 Kg/Mtr.flat of 0.510mt length 1 no\"s=(1x0.59x0.510) |
| 7 | GI barbed wire anticlimbing devices 3Kg. Per support, 2 no\"s quantity |
| 8 | Back Clamp for anticlimbing device 25x3 mm., flat, 0.51 Kg/Mtr.(4x0.59x0.51) |
| 9 | 11 KV pin insulator polymer |
| 10 | H W fitting (B&S) 70 KN, 3 Bolt |
| 11 | Disc insulator (B&S) 70 KN polymer |
| 12 | Earthing of support coil type |
| 13 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/mtr-2 mtr. For Connecting pole with coil Earthing |
| 14 | PG clamp for 55 sq mm AAA conductor |
| 15 | GI Nut, Bolt & Washer of Different Sizes (7.433 Kg each cut pole) |
| 16 | Black paint |
| 17 | Yellow colour paint for background |
| 18 | CIVIL & SERVICES WORKConcreting ratio 1:1:5:3 (500mmx500mmx1800mm) |
| 19 | Coupling ratio 1:1.5:3 (500x500x450 mm) =0.1125 cu mtr. |
| 20 | Material for 11KV cut Point with 90 Degree AngleWPB 160x152 (11 Mtr Long, 30.44 KG/Mtr) |
| 21 | Straight Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 1.2 mtr, 2 no\"s channel required =(2x9.56x1.2) |
| 22 | Fish plate 50x6 mm., 2.36kg/mtr., each 0.280 mtr. Length, 8no\"s required(8x2.36x0.28) |
| 23 | Straight Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 0.306 mtr,4 no\"s channel required |
| 24 | Danger Plate 2 No\"s |
| 25 | Back Clamp for danger plate 25x3 mm. flat, 0.59 Kg/Mtr.flat of 0.510mt length 1 no\"s=(1x0.59x0.510) |
| 26 | GI barbed wire anticlimbing devices 3Kg. Per support, 2 no\"s quantity |
| 27 | Back Clamp for anticlimbing device 25x3 mm., flat, 0.51 Kg/Mtr.(4x0.59x0.51) |
| 28 | 11 KV pin insulator polymer |
| 29 | H W fitting (B&S) 70 KN, 3 Bolt |
| 30 | Disc insulator (B&S) 70 KN polymer |
| 31 | Earthing of support coil type |
| 32 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/mtr-2 mtr. For Connecting pole with coil Earthing |
| 33 | PG clamp for 55 sq mm AAA conductor |
| 34 | H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no\"s qty. required ( 1 Pair) |
| 35 | H.T. Stay set (Complete ) |
| 36 | H.T. Stay Insulator Type-C |
| 37 | 7/10 SWG Stay Wire 15kg /stay |
| 38 | GI Nut, Bolt & Washer of Different Sizes (7.433 Kg each cut pole) |
| 39 | Black paint |
| 40 | Yellow colour paint for background |
| 41 | CIVIL & SERVICES WORKFixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard. |
| 42 | Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) |
| 43 | Coupling ratio 1:1.5:3 (500x500x450 mm) =0.1125 cu mtr. |
| 44 | MATERIALS FOR 11KV PIN POINT WITH WPBWPB160 X152 (11 mtr. Long 30.44 KG/ MTR) |
| 45 | 11KV V Cross Arm (10.2 Kg each) |
| 46 | Top Bracket100x50x6 mm GI Channel |
| 47 | Danger Plate 1 No\"s |
| 48 | Back Clamp for danger plate 25x3 mm. flat, 0.59 Kg/Mtr.flat of 0.510mt length 4 no\"s=(1x0.59x0.510) |
| 49 | GI barbed wire/ Anticlinbing device (3kg/pole) |
| 50 | Back Clamp for anticlimbing device 25x3 mm., flat, 0.59 Kg/Mtr.(4x0.59x0.51) |
| 51 | 11 KV pin insulator polymer |
| 52 | Earthing of support coil type |
| 53 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/mtr-2 mtr. For Connecting pole with coil Earthing |
| 54 | GI nuts & bolts of Assorted size (1.45 kg /pin point) |
| 55 | 80 mm2 AAAC |
| 56 | Black Paint |
| 57 | Yellow\" Colour Paint for Background |
| 58 | Civil & Services Concreting ratio 1:1.5:3 (500mmx500mmx1800mm)= 0.45 cu mtr |
| 59 | Coupling ratio 1:1.5:3 (500x500x450 mm) =0.1125 cu mtr. |
| 60 | PART-B 25KVA Plinth Mounted DTR WPB160X152 (11Mtr Long, 30.44KG/Mtr.) |
| 61 | Top Channel Arm 100 x 50 x 6 mm(9.56 Kg/ mtr) Each channel length 1.2 mtr, 2 No\"s channelrequired=(2x9.56x1.2) |
| 62 | Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no\"s required = (6x2.36x0.280) |
| 63 | AB Switch Mounting Channel 75x40x4.8 mm GI Channel(3000 mm long)(7.14Kg/Mtr., 2 No\"s.) (Each 2x3.000x7.14)= 42.84 Kg) |
| 64 | AB Switch Side Support Channell00X50X6mm,9.56 KG/Mtr, each channel length 0.35 mtr., 2 no’s channel required ( 9.56X2 x0.35) |
| 65 | Channel Support for down Pipe 75X40X 4.8 mm 7.14KG/ Mtreachchannel length 0.8 Mtr., 1 no\"s channel required =(7.14x0.8x1) |
| 66 | HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000mm long)(7.14Kg./Mtr., 2 No\"s.) (Each 2x3.000X7.1 4= 42.84 Kg) |
| 67 | Cantilever Support Channel 75x40x4.8 mm GI Channel (810mm long,2 No\"s.) (7 .14Kg. /Mtr., 2 No\"s.) (Each 2X0.810x7.14)=11.57 Kg) |
| 68 | Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long)(4.5Kg./Mtr, 2 No\"S.) (Each 2x1.282x4.5= 11 .54Kg) |
| 69 | LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4. 5Kg.fMtr, 2 No\"s) (Each 2x1x4.5 Kg) |
| 70 | 50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 Mtr. For mesh formation,12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtrfor DTH Body,0.5mt for LTDB & AB Switch operating handle, 3 mtr for fencing) (each 65.6x2.36=154.81 kg) |
| 71 | 25 KVA , 11/ 0.4 KV (AL) Transformer BlS Energy level II |
| 72 | LT Distribution Box with MCCB, Aluminium Busbar of single Baywith kit kat fuse for 25 KVA S/S |
| 73 | 55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.) |
| 74 | 4 Cx 35 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf. |
| 75 | AB Switch(11 KV,200A.3pole,50Hz) |
| 76 | H.G.Fuse(11KV.200A.3Pole) |
| 77 | PG Clamp for 55 sq.mm AAA conductor |
| 78 | Disc insulator (B& S)70 KN polymer |
| 79 | H W fitting (B&S)70KN(3bolted) |
| 80 | Lightning Arrester(l2KV, 10KA) Station Class 2 |
| 81 | l l KV pin insulator polymer |
| 82 | HT Stayset complete |
| 83 | HT stay clamp (1.9 Kg/ pair) |
| 84 | HT stay insulator TYPE-C |
| 85 | 7/10 SWG GI stay wire Grade-2 (15 Kg/set) |
| 86 | 40 mm nominal bore G.I pipe (medium gauge) earling device with 3 mtr long) |
| 87 | GI nuts & bolts of Assorted size (25 kg /DSS DP) |
| 88 | GI barbed wire / Anticlimbing size (3 kg /DP) |
| 89 | Black Clamp for Anticlimbing device 25x3 mm,flat of 0.510 mt length 8 nos=(8x0.59x0.51) |
| 90 | Danger plate 11 kv |
| 91 | Black Clamp for Anticlimbing device 25x3 mm, flat of 0.510m length 2 nos=(2x0.59x0.510) |
| 92 | Name plate |
| 93 | Structure Numbering and MarkingYellow\" Colour Paint for Background |
| 94 | Block Colour Pnint for numbering |
| 95 | Civil & Services workConcreting ratio 1: 1: 5: 3(500 mm X500 mmX 1800mm) = 0.450 Cu. Mtr |
| 96 | Couping ratio 1: l.3:3 (500 mm X500 mmX450 mm) = 0.1113 cu. Mtr |
| 97 | Fixing of stay set with 0.5Cumcement concrete foundationl:3:6 size( 900mmx600mmx900mm) using 40mm BHG metal with alllabour and material except stay set, stay wire , stay insulator . |
| 98 | Constructionof earthing chamber including installation of earthing pipe making earthing chamber including excavation,soil treatment with bentonide powder, calculation of earth resistance , including installation of 3mt GI pipe 40mm/50mm including welding of GI flat around pipe |
| 99 | DTR Plinth |
| 100 | Supply and Erection of GI Fencing with Gate |
| 101 | MATERIALS FOR SERVICE CONNECTION4c X 10 SQ MM Armoured aluminium cable - XLPE insulated |
| 102 | Insulated piercing connector Type- C main 16 to 95 sq mm & Tap 1.5 to 16 sq mm For LT AB Cable |
| 103 | GI Nut, Bolt & washer |