}

Tender For Work Of Narmada Based Water Supply Scheme For 163 Village Of Dhorimanna Chouhtan Block Distt. Barmer Pkg Cp-03 Chouhtan-1 Under Jica Funded Rrws And Fluorosis Mitigation Project Phase Ii On Spr Basis With 1 Yr Defect Notification Period And 10 , barmer-Rajasthan

Public Health Engineering Department-PHED has published Tender For Work Of Narmada Based Water Supply Scheme For 163 Village Of Dhorimanna Chouhtan Block Distt. Barmer Pkg Cp-03 Chouhtan-1 Under Jica Funded Rrws And Fluorosis Mitigation Project Phase Ii On Spr Basis With 1 Yr Defect Notification Period And 10 . Submission Date for this Tender is 14-12-2023. Water Supply Project Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39238162
Corrigendum : Tender For Work Of Narmada Based Water Supply Scheme For 163 Village Of Dhorimanna Chouhtan Block Distt. Barmer Pkg Cp-03 Chouhtan-1 Under Jica Funded Rrws And Fluorosis Mitigation Project Phase Ii On Spr Basis With 1 Yr Defect Notification Period And 10
Open Tender
Indian
Rajasthan
barmer
14-12-2023

Tender Details

Tender For Work Of Narmada Based Water Supply Scheme For 163 Village Of Dhorimanna Chouhtan Block Distt. Barmer Pkg Cp-03 Chouhtan-1 Under Jica Funded Rrws And Fluorosis Mitigation Project Phase Ii On Spr Basis With 1 Yr Defect Notification Period And 10 Years O And

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Oct-2023 CORRIGENDUM I Date 09-11-2023
2 13-Oct-2023 ADDENDUM I Technical Bid 09-11-2023
3 07-Nov-2023 CORRIGENDUM II Date 04-12-2023
4 02-Dec-2023 CORRIGENDUM III Date 14-12-2023

Key Value

Document Fees
INR 50000 /-
EMD
INR 131530000.0 /-
Tender Value
Refer document

BOQ Items

Name of work-Work of Narmada Based Water Supply Project for 163 Villages of Dhorimanna and Chouhtan Block, Distt. Barmer (Package CP-03, Chouhtan-1 under JICA funded Rajasthan Rural Water Supply & Fluorosis Mitigation Project Phase II on SPR basis with one-year Defect Notification period & 10 years O&M. (CP-03)
Sl. No. Item Description
1BILL 1 - WATER TREATMENT PLANT
2Survey, Design, Construction, Testing and Commissioning of Rapid Gravity Water Treatment Plant (Output Capacity 58 MLD or 2636.365 KL/Hr.) including all relevant Civil, Electrical, Mechanical, Instrumentation, Automisation, SCADA Worksalong with Ancillary Civil Works as per specifications and Employer"s requirement complete in all respect. at ALETI HW. (Instrumentation, Automisation and SCADA works shall be paid as per Section for Instrumentation, Outdoor Switchyard as per Section for Electrical)
3Inlet and Distribution System: Inlet chamber, Measuring channel, Flash Mixers, Main/ By Pass Channel to Filter Beds, Walkways, Stairs, Railings etc.
4Equipments
5Civil works
6Clariflocculators: Pipes between Flash Mixers and Clariflocculators, Clariflocculators, Walkways, Stairs, Railings, Clarified Water Channel to the Filter Inlet Channel and Sludge Pipe to Sludge Buffer Tanks etc.
7Equipments
8Civil works
9Filters and Filter House: Filters,Distribution/ Back Wash Channel, Pipe Gallery with Clear Water Channel and Sump, Control Gallery, observation Platforms, Walkways, Stairs, Railings, Back Wash Water Tank, Clear Water Measuring Channel, and any other item required for completion of filter plant other than specified in BOQ.
10Equipments
11Civil works
12Administrative and Control Building: Administrative Control Building, Backwash Pumps, Air Blowers, Laboratory Equipment, Water Cooler, Furniture etc. as per Scope of Work and Specifications
13Equipments
14Civil works
15Chemical House: Chemical House, Alum/PAC and Lime Dosing Equipment, Piping to the Injection Point and Injection Devices
16Equipments
17Civil works
18Chlorine Building, Chlorination and Chlorine Storage: Chlorine Storage Area, Chlorine Building, Chlorine Toners, Chlorination Equipments, Chlorination Chamber, Injection Devices etc
19Equipments
20Civil works
21Backwash Water and Sludge Recycling and Disposal: Construction of Wwater Recirculation System including associated work of Inlet/Outlet, Recycling of Backwash Water and Sludge Handling and Disposal System, Pumps and Piping etc.
22Equipments
23Civil works
24BILL-2 - PIPELINE WORKS
25Earth work in Excavation in all kind of Strata (all type of Soil/ soft rock/ hard rock etc), including Road Cutting in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc) and including road restoration in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc), Sand/Soil Bedding in rocky starta or wherever required, disposal of surplus excavated Earth for the Trench, Road Cuttings/Crossing (other than pushin) & Road resotoration ,River/ Drain and Canal/Gas/Petroleum Pipelines Crossing (other than pushin), Construction of RCC -Pedestals, Anchor/Thrust/Fixidity Blocks, Cross walls, Protective Aprons, Encasing, other Civil Worksetcas per specifications and Employer requirement for following diameter Pipe Line:-
2675mm
2790mm
28100 mm
29110mm
30125mm
31140mm
32150 mm
33160 mm
34180mm
35200 mm
36225mm
37250 mm
38300 mm
39350 mm
40450 mm
41500 mm
42700 mm
43900 mm
441200 mm
45Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI markedS/SDI (Ductile Iron) K7 Class Pipeas per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSRRising Main, Cluster/Village Distributionincluding Flanged Pipes wherever required, Socket/FlangedSpecials and Isolations and Interconnection works with existing system where dovetailing is required . This work also includes the required Laying above the Ground Level, Crossing requiredfor Drain, Canal, River and Road crossingswith Reinstatement Works,following diameters of Pipe Linesas per Employer requirement and Specification.(Payment for Casing Pipe to CrossNational/State/Mega Highway/GREF Road shall be made as per seperate item. However, MS / DIDF / Fitting for other to this shall be paidin this section ).
46100 mm dia
47150 mm dia
48200 mm dia
49250 mm dia
50300 mm dia
51350 mm dia
52450 mm dia
53500 mm dia
54700 mm dia
55900 mm dia
56Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI markedS/SDI (Ductile Iron) K9 Class Pipeas per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSRRising Main, Cluster/Village Distributionincluding Flanged Pipes wherever required, Socket/FlangedSpecials and Isolations and Interconnection works with existing system where dovetailing is required . This work also includes the required Laying above the Ground Level, Crossing requiredfor Drain, Canal, River and Road crossingswith Reinstatement Works,following diameters of Pipe Linesas per Employer requirement and Specification.(Payment for Casing Pipe to CrossNational/State/Mega Highway/GREF Road shall be made as per seperate item. However, MS / DIDF / Fitting for other to this shall be paidin this section ).
57100 mm
58150 mm
59200 mm
60250 mm
61Survey,Design, Supply, Laying, Jointing, Testing and Commissioning in position to correct line spirally welded MS /SAW/Fabricated Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, forthickness (as per approved design) and inside dia Mtr, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating .Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water. Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
62100 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
63125 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
64150 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
65200 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
66250 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
67300 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
68350 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
69450 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
70500 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
71Outer Dia. 711 mm & 06.30 mm min. thickness confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
72Outer Dia. 914 mm & 08 mm min. thickness confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
73Outer Dia. 1219 mm & 10 mm min. thickness confirming to IS 3589-2001 or its latest revision/ amendments/ reaffirmed
74Providing, erction andcommissioning of Cathodic protection for the buried portion of 900 mm & 1200 mm MS pipeline including cost of rubber gaskets etc. required for cathodic protection seperation, if any, construction of terminals etc. as per specification
75900 mm dia
761200 mm dia
77Survey, Design, Supply, Lying and Pushing of MS Casing Pipe as per approved design & drawing of concern Department Authority/EIC( for following carrier pipe dia.) of specified thickness (thikness as per approved drawing&design) including all type ofrequired size of casing pipe , SluiceValves/other Valves at U/S and D/S and jointing/supporting materials with valve chamber etc civil work approved by concerned Department Authority/EIC by Trenchless Method adopting any suitable Technology Below Ground at required depth under Running Traffic Condition as per NH/SH/GREF/MEGA Highway Standard/GREF road/Canal Crossing, including Excavation of Driven Pits and Exit Pit with proper Protection, Construction of Temporary Works etc. as perapproved by concernAuthority Specificationas per Employer"s Requirement Specification for following CarrierPipe diameter (Carrier Pipe shall be measured in Pipe Line Length in separate item) including all type ofExcavation of boring pit & receiving pit provide Thrust Wall / Bed as required boring, jacking of MS pipe in embankment for crossingas per approved design &drawing - For all soil strata (for Canal/road etc Crossing ) by trenchless technology
78MS Casing Pipe required for carrier pipe of 100 mm dia
79MS Casing Pipe required for carrier pipe of 125 mm dia
80MS Casing Pipe required for carrier pipe of 150 mm dia
81MS Casing Pipe required for carrier pipe of 200 mm dia
82MS Casing Pipe required for carrier pipe of 250 mm dia
83MS Casing Pipe required for carrier pipe of 300 mm dia
84MS Casing Pipe required for carrier pipe of 350 mm dia
85MS Casing Pipe required for carrier pipe of 450 mm dia
86MS Casing Pipe required for carrier pipe of 500 mm dia
87MS Casing Pipe required for carrier pipe of 700 mm dia
88MS Casing Pipe required for carrier pipe of 900 mm dia
89MS Casing Pipe required for carrier pipe of 1200 mm dia
90Survey, Design, Supply, Laying, Aligning, Fixing in position, Jointing, Testing, Commissioningof ISI marked HDPE Pipes of Class PE 80, PN-6 suitable for Potable Water as per IS 4984:1995 (Amended up to date) withSpecials and necessary Jointing Material like Mechanical Connectors i.e. Thread / Insert Joint / Quick Release Coupler Joint /Compression Fitting Joint or Flanged Joint and Special Jointing Pipe by Butt Fusion / Electro Fusion Welding method,Flanged Joints shall be used for Jointing HDPE Pipes to Valves and Non-HDPE Pipes. This work also includes the Drain/ Canal/ River/ Road Crossingswith Reinstatement works forfollowing outer diameters of Pipe Lines as per Employer"s Requirement and Specification :(Payment for Casing Pipeto CrossNational/State/Mega Highway/GREF Roadshall be made as per seperate item. However MS / DIDF / Fitting for other to this shall be measured in this section ).-
9175mm
9290mm
93110mm
94125mm
95140mm
96160mm
97180mm
98200mm
99225mm
100Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating Tamper ProofCI Single Air valveincluding construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer"s Requirement and Specification -
10125 mm
10240mm
10350mm
104Supply, installation, Testing and Commissioning of following diameter PN 1.6 Rating DI Kinetic type temper proof Double orifice Air Valve with Isolation Valves including construction of RCC Air Valve Shaft(height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer"s Requirement and Specification -
10550mm
10680mm
107100mm
108150mm
109Supply, installation, Testing, Commissioning and Jointing inpipe line, combinationAir Release Valve Kinetictype withsingle chamber housed Double orificeandhave3functions,largeAirexhaust,smallAirventingandlargeair intakeduringvacuum ofpipelineofapprovedmakesoffollowingpressure rating anddiaandasperfollowingspecifications: Governingstandard-AWWAC512, Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GRSG-400/12asperIS1865, Float&internaltrim:AISI304stainlessSteel,Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder (EP- P)/FusionBondedEpoxy(Non-Toxic&suitablefordrinkingwater)coatedwith minimumthicknessof250micronappliedonbody&cover insideandoutside Fasteners- CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, forfullycomplywith AWWA C512), Valveincludingallmaterial,labour, testingandcommissioningasperTechnicalSpecificationsandas perdirectionof Engineer in charge.
110150 mm dia (PN 1.6 )
111Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating CI Scour Valvesincluding all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc,complete work at all required locations per Employer"s Requirement and Specification:-
11280mm
113100mm
114Supply, Installation, Testing and Commissioning of following diameter PN 1.6 Rating CI Scour Valves (with Gear Arrangement if required)including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc,complete work at all required locations as per Employer"s Requirement and Specification:-
11580mm
116100mm
117150 mm
118200 mm
119250 mm
120300 mm
121Supply, Installation, Testing and Commissioning of following diameter PN 1.0/1.6 Rating D/F CI Sluice Valves(with Gear Arrangement if required) including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc,complete work at all required locations per Employer"s Requirement and Specification:-
122100 mm dia
123150 mm dia
124200 mm dia
125250 mm dia
126300 mm dia
127Supply, Installation, Testing and Commissioning offollowing diameter suitable RatingDI Soft Seated Sluice Valves(with Gear Arrangement if required) for Off takes/Junctions, Sectionalising, outside of pump house and at upstream of FCV to Pipe Line, including in-village pipelines including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc, complete work as per Employer"s Requirement and Specification:-
128Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
12980mm
130100mm
131125mm
132150mm
133200mm
134250mm
135300mm
136350mm
137400mm
138450mm
139500mm
140600 mm
141700 mm
142800 mm
143900 mm
1441000 mm
1451100 mm
146Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
147100 mm dia
148125 mm dia
149150 mm dia
150200 mm dia
151350 mm dia
152400 mm dia
153500 mm dia
154600 mm dia
155700 mm dia
156900 mm dia
1571000 mm dia
1581200 mm dia
159Supply, Installation, Testing and Commissioning of following diameter suitable RatingDI Soft Seated Butterfly Valves for Sectionalising to Pipe Line including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc, complete work as per Employer"s Requirement and Specification:-
160Class PN 1.6 Manually Operated with Gear
1611200mm
162Class PN 1.6 Motorised Operated
163700 mm dia
164900 mm dia
1651000 mm dia
1661200 mm dia
167Supply, Installation, Testing and Commissioning of following diameter suitable RatingDIdouble flanged resilient seated Dual plate check valves onindividual & common delivery piping of following sizes (PN-1.6) for Sectionalising to Pipe Line including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc, as per Employer"s Requirement and Specification:-
168100 mm dia
169125 mm dia
170150 mm dia
171200 mm dia
172350 mm dia
173400 mm dia
174500 mm dia
175600 mm dia
176700 mm dia
1771000 mm dia
178Supply, Installation, Testing and Commissioning offollowing diameter suitable RatingPlungar Type Flow and Pressure Control Valves including all type of jointing material, Dismantling Joints, Fittings, nutbolt, rubbersheet and Specials etc,along as per Employer"s Requirement and Specification:-
17980mm
180150mm
181Carrying out Surge Analysis, Construction, Supply, Installation, Testing and Commissioning of suitable Surge Controlled Devices as approved with all Piping, Valves, Accessories forthe Transmission and Rising/ Pumping Mains complete as per Employer"s Requirement and Specifications :-
182Transmission Main
183Raw Water Transmission Main from RD 74 Km RWPS TO Aleti H/W
184RWR TO WTP
185ALETI HEAD WORKS to IPS BAMARALA
186IPS BAMARALA to IPS PHAGALIYA
187IPS BAMARALA to IPS SOBHALA DARSHAN
188IPS PHAGALIYA to CPS FAKIRON KA NIWAN
189IPS PHAGALIYA to CPS SATA
190IPS SOBHALA DARSHAN to IPS DHANAOO
191IPS SOBHALA DARSHAN to CPS SERWA
192ESRs Rising Main from
193Aleti HEAD WORKS
194IPS BAMARALA
195IPS PHAGALIYA
196CPS SATA
197CPS FAKIRON KA NIWAN
198CPS SERWA
199IPS SOBHALA DARSHAN
200Survey, Design, Construction of RCC valve chambers for Sectionalizing valves,offftake/junction valves, flow meters(FM+DJ) and (FM+DJ+SV), complete work at all required locations. This also includesexcavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for following pipe sizes as per employer"s requirement and Specification :-
201up to 125 mm (Minimum size 1.13mx0.85m)
202above 125 mm & up to 200mm (Minimum size 1.17mx0.95m)
203above 200 to 300mm (Minimum size 1.26mx1.185m)
204350 to 450mm (Minimum size 1.39mx1.43m)
205500 to 700mm (Minimum size 1.61mx1.75m)
206750 to 1200mm (Minimum size 2.10mx2.30m)
207Survey, Design, Construction of RCC chambers for Scourvalves, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for the following Valve sizes as per employer"s requirement and Specification :-
20880/100 mm dia (Minimum size 1.13mx0.85m)
209Survey, Design, Construction of RCC chambers for SV+DJ+FCV+FM+DJ, within campus, supports,complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials the following Valve sizes as per employer"s requirement and Specification :-
210up to 250mm (Minimum size 3.0mx1.5m)
211BILL-3 - RESERVOIR WORKS
212Surveying, Geotechnical Investigations, Designing and construction of Raw water Reservoir, earth work, Double PCC Block Lining work, HDPE film work, Ramp, inlet sump, inlet/delivery well, including the works related to inlet arrangements delivery well, making interconnection, Bituminous Road work all around the RWR; with all finishing work to complete the structure in all respect etc. as per attached drawing, scope of work, specification and as per direction of Engineer-in-charge complete in all respect at Aleti HW. (As per approved Drawing & Designfrom MNIT Jaipur/MBM Engineering college Jodhpur or any Indian Institute of Technology Govt. of India.)
2131420 ML capacity
214Survey, Design, Construction, Testing, Commissioningof circular RCC Clear Water reservoirs includingCI/DI puddle collars for inlet, one/two outlets, overflow and washout. It also includes Providing and fixing double flanged ISI marked DI class K- 9 pipes {as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee etc. Providing clamps at every 3 MTR, jointing metrials such as nuts, bolt, rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work} for inlet, outlet, overflow and washout along with ductfoot bends, DI soft seated Valves along with Dismantling Joints on inlet, outlet and washout pipes with sluice valves (both of these piping upto the chamber where these will join storm water drain pipe), construction of chamber to join overflow+washout with storm water drain pipe complete in all respect (Rates are invited for SBC 7 MT/Sqm or as per site,Earthquake zone IVas per IS 1893; However payment shall be made as per Conditions of Contract Agreement.) at following locations:-
215CPS Sata (800 KL)
216CPS Fakhiron ka Niwan (700 KL)
217CPS Serwa(500 KL)
218CPS Aleti HW (5750 KL)
219IPS Bamarla (5600 KL)
220IPS Phagaliya (1400 KL)
221IPS Dhanoo (3200 KL)
222IPS Shobhala Darshan (3700 KL)
223Survey, design, Construction, Testing, Commissioningof RCC Elevated Service reservoirs at different locations and as per the stated effective capacity includingCI/DI puddle collars for inlet, outlet, overflow and washout. It inludes Providing and fixing double flanged ISI marked DI class K- 9 pipes {as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee etc. Providing clamps at every 3 MTR, jointing metrials such as nuts, bolt, rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work} for inlet, outlet, overflow and washout along with ductfoot bends, DI soft seated Valves along with Dismantling Joints on inlet, outlet and washout pipes; making by pass arrangements along with Sluice Valve with Dismantling joints for by passing the ESR for supplying water directly from inlet, making connection of overlow pipe with washout on the downstream of its" Sluice Valve approximately at 6m away from ESR, providing and laying NP pipe from the junction of overflow with washout with minimum 20m length. Making Header on the outlet pipe (on the downstream of by pass arrangements) to faciliate joining more than one cluster distribution pipeline emanating from the ESR, Plinth Protection, Levelling and Plantation in campus, Chambers, Lightneing arrestor Complete in all respect with Design and Construction of RCC FramedService Room ( Min size 2.4m x 2.4m ) in the ESR campusas per employers requirementsand specifications : (Rates are invited for SBC 7 MT/Sqm or as per site, 18m staging, Earthquake zone IVas per IS 1893; However payment shall be made as per Conditions of Contract Agreement.) For staging above 18 meters,2% per meter increase over quoted rates shall be payable. Staging above 22m will not be allowed.
224100 KL
225150 KL
226200 KL
227250 KL
228300 KL
229400 KL
230500 KL
231BILL-4PUMPING STATION WORKS
232Civil WORKS
233Survey,Design and Construction of RCC framed type structure Pump House with transition zone and complete civil work for taking water from WRD canal offtake to RWPH , (with provision of trash rack from outlet Chamber, Sump for raw water pump house to accommodateVT pumps, providingassociated Electrical and plumbing works for water supply and sanitation, Civil work required for installation of gantry for Semi EOT crane, Pipes and specials, rain water harvesting & collection system for rain water frompump house roofto thesumpcomplete in all respect as per employer"s requirement and Specifications at following location:-
234RD 74 KM RWPS
235Survey, Investigations, Design andModification, Construction of intake structure to accommodate VT pumps,providingassociated Electrical and plumbing works for water supply and sanitation, Civil work required for installation of gantry for Semi EOT crane, Pipes and specials, rain water harvesting & collectionsystem for rain water frompump house roofto thesumpcomplete in all respect as per employer"s requirement and Specifications at following location:-
236RWPS for RWR to WTP
237Survey,Design and Construction of RCC framed structure pump house buildingto accommodate C/ Fpump sets, Maintenance bay, Control Roomwith associate Electrical / Plumbing work. Thisshall includeCivil works required for erection of Semi EOT crane,installation of pumps and panels, cable trenches, drainage, access platforms, ladders, thrust/anchor blocks, pipe supports, Pipes and specials, rain water harvesting & collectionsystem for rain water frompump house roofto thesumpcomplete in all respect as per employer"s requirement and Specifications at following location:-
238At Aleti Head work
239At Bamarla Head work
240At Shobhala Darshan Head work
241At Phagaliya Head work
242At Serwa Head work
243At Sata Head work
244At Fakiro Ka Niwan Head work
245Supply of office furniture as per Employer requirement and Specification as per Specifications at RD 74 KM RWPS, Aleti Head work, Bamarla Head work, Shobhala Darshan Head work, Barmer CR, Chouhtan CR, Phagaliya Head work, Serwa Head work, Sata Head work and Fakiro Ka Niwan Head works
246MECHNICAL WORKS AND PUMPING MACHINARY:- Design, Providing , Installation, Testing, Commissioningfor following as per Employer requirement and Specification:-
247MS/DI pipe work for suction piping, from puddle Collar in CWR and common cum individual suction header with inside and outside protection (Tape coating/ epoxy coating) and all miscellaneous bore in pump house wall at following location :-
248Aleti HEAD WORKS
249AletiRWPS
250IPS BAMARALA
251IPS PHAGALIYA
252IPS SOBHALA DARSHAN
253MS/DI pipe work for suction piping, from puddle collar in CWR and common suction header and individual suction header with inside and outside protection (Tape coating/ epoxy coating)and all miscellaneous bore in pump house wall at following locations :-
254CPS SATA
255CPS FAKIRON KA NIWAN
256CPS SERWA
257MS/DI pipe work for reducer, enlarger, inividual delivery piping of each pump and common delivery header with inside and outside protection (Tape coating/ epoxy coating)up to Valve/flow meter and related works including bore in walls at following locations as -:-
258RD 74 KM RWPS
259RWPS for RWR to WTP
260MS/DI pipe work for individual suction from common header, reducer, enlarger, inividual delivery piping of each pump and common delivery header with inside and outside protection (Tape coating/ epoxy coating)up to Valve/flow meter and related works including bore in walls at following locations as -:-
261Aleti HEAD WORKS
262IPS BAMARALA
263IPS PHAGALIYA
264IPS SOBHALA DARSHAN
265CPS SATA
266CPS FAKIRON KA NIWAN
267CPS SERWA
268Manually operated PN 1.0/ 1.6 ratingsoft seated sluice valves with dismantling joints at intersection of CWR outlet with common suction header and individual suction of each pump at following locations:-
269RD 74 Km RWPS
270RWPS at Aleti
271Aleti HEAD WORKS
272IPS BAMARALA
273IPS PHAGALIYA
274IPS SOBHALA DARSHAN
275CPS SATA
276CPS FAKIRON KA NIWAN
277CPS SERWA
278Ductile Iron PN 1.6 rating Double Plate Check valves with Expansion Bellow Type Dismantling Joint oneach pump delivery sideat following locations:-
279RD 74 Km RWPS
280RWPS at Aleti
281Aleti HEAD WORKS
282IPS BAMARALA
283IPS PHAGALIYA
284IPS SOBHALA DARSHAN
285CPS SATA
286CPS FAKIRON KA NIWAN
287CPS SERWA
288Ductile IronPN 1.6 ratingElectrically operated Butterfly/ Soft seatedSluice valve with actuators oneach individual delivery of each pump side at following locations:-
289RD 74 Km RWPS
290RWPS at Aleti
291Aleti HEAD WORKS
292IPS BAMARALA
293IPS PHAGALIYA
294IPS SOBHALA DARSHAN
295CPS SATA
296CPS FAKIRON KA NIWAN
297CPS SERWA
298PN 1.6 ratingManually operated soft seated sluice valves with expansion bellow type dismantling joints on individual delivery of each pump as well as on common delivery header at following locations:-
299RD 74 Km RWPS
300RWPS at Aleti
301Aleti HEAD WORKS
302IPS BAMARALA
303IPS PHAGALIYA
304IPS SOBHALA DARSHAN
305CPS SATA
306CPS FAKIRON KA NIWAN
307CPS SERWA
308Vertical Turbine Pumps with 6.6/.415 KV motor, Column pipe, shaft and other accessories complete at following location:-
309RD 74 Km RWPS (VT pump with 6.6 KV motor)
310From Canal to RWR Aleti HW (for normal flow) (2W+1S)
311From Canal to RWR Aleti HW (for Pre-Closure flow) (4W+2S)
312RWPS at Aleti (VT pump with 0.415 KV motor)
313From RWR to WTP Aleti HW (2W+1S)
314HSC / End Suction type Centrifugal Pump sets (1W+1S) with LT 0.415 kV horizontal motor,base plates, Coupling, foundation bolts, accessories etc. on concrete foundation with accurate levellingand proper alignment completeat following locations:-
315ALETI HEAD WORKS
316ALETI HEAD WORKS to IPS BAMARALA (3W+2S)
317ALETI HEAD WORKS to P-SR PRATAP NAGAR CL-02 , P-SR RADOOCL-05 , P-SR ARNIYALI CL-03 , P-SR DHAKON KA GOLIYA CL-04(1W+1S)
318ALETI HEAD WORKS to P-SR ALETI CL-01(1W+1S)
319IPS BAMARALA
320IPS BAMARALA to IPS PHAGALIYA(1W+1S)
321IPS BAMARALA to IPS SOBHALA DARSHAN(2W+2S)
322IPS BAMRALA to P-SR BAMARALA CL-06(1W+1S)
323IPS BAMRALA to P-SR MAYLON KI BERICL-12 , P-SR BHAWANIPURA CL-11 , P-SR CHALKANA CL-10(1W+1S)
324IPS BAMRALA to P-SR BHARTHE KI BERI CL-07 , P-SR MOTI KI BERI CL-08 , BHAGBHARE KI BERI CL-09 (1W+1S)
325IPS BAMRALA to P-SR SHERPUR CL-13 , P-SR AAKAL CL-14 , P-SR KHARADER CL-15 route29 LPS / 68 m head/37 KW (1W+1S)
326IPS SOBHALA DARSHAN
327IPS SOBHALA DARSHAN to IPS DHANAOO (2W+2S)
328IPS SOBHALA DARSHAN to CPS SERWA (1W+1S)
329IPS SOBHALA DARSHAN to P-SR ROHILA CL-57 , P-SR SONRI CL-58 , P-SR DOB KI BERI CL-59 , P-SRPABUBERI CL-60 (1W+1S)
330IPS SOBHALA DARSHAN to P-SR SHOBHALA DARSAN CL-56 , P-SR MANDON KI BERI CL-61 , P-SR BHOONIYACL-62 (CH-2) (1W+1S)
331IPS PHAGALIYA
332IPS PHAGALIYA to CPS FAKIRON KA NIWAN (1W+1S)
333IPS PHAGALIYA to CPS SATA (1W+1S)
334IPS PHAGALIYA to P-SR PHAGALIYA CL-19 (1W+1S)
335IPS PHAGALIYA to P-SR GANGASARA CL-20 , P-SR GORA CL-21 (1W+1S)
336IPS PHAGALIYA to P-SR PANORIYA CL-16 , P-SR BOLI CL-18 , P-SR KHARI CL-17 (1W+1S)
337CPS SERWA
338CPS SERWA to P-SR SERWA CL-48(1W+1S)
339CPS SERWA to P-SR SAMAWALI CL-49 , P-SR SAMON KI DHANI CL-50 , P-SR BHANWAR CL-52 (1W+1S)
340CPS SERWA to P-SR SALRIYA CL-51 , P-SR SINHAR CL-54 , P-SR BEESASAR CL-55 (CH-2) (1W+1S)
341CPS SERWA to P-SR KUNDANPURA CL-53(1W+1S)
342CPS SATA
343CPS SATA to P-SR SATA CL-22 , P-SR RANWA CL-27 , P-SR NAWAPURA CL-28(1W+1S)
344CPS SATA to P-SR GANGASARIYA CL-29 , P-SR TARLA CL-30 , P-SR BHANWARIYA CL-31 , P-SR GIRA CL-32 (1W+1S)
345CPS SATA to P-SR ARTI CL-35 , P-SR MEETHRI CL-34 , P-SR CHHOTA HATHLA CL-33 (1W+1S)
346CPS SATA to P-SR BAKHASAR CL-23 , P-SR BHALGAON CL-26 , P-SR TAREESARA CL-24 , P-SR BAWARWALA CL-25(1W+1S)
347CPS FAIKORON KA NIWAN
348CPS FAIKORON KA NIWAN , P-SR MOOLANI CL-36 , P-SR JHARPA CL-40 , P-SR NAWATALA BAKHASAR CL-41 , P-SR BHARA CL-42 (1W+1S)
349CPS FAIKORON KA NIWAN , P-SR BAMARLADER CL-38 , P-SR SINHANIYA CL-37 , P-SR BHADA CL-39 (1W+1S)
350CPS FAKIRON KA NIWAN , P-SR HARPALIYA CL-45 , P-SR SUJON KA NIWAN CL-43 , P-SR SARLA CL-47 , P-SR SARAIYON KA TALA CL-46 (CH-2) , P-SR DEEPLA CL-44 (1W+1S)
351Overhead Treverssing Crane Semi Electrically operated of suitable capacity along with MS girders, MS rails, electric hoist, chain etc. at following locations:-
352RD 74 Km RWPS
353RWPS at Aleti
354Aleti HEAD WORKS
355IPS BAMARALA
356IPS PHAGALIYA
357IPS SOBHALA DARSHAN
358CPS SATA
359CPS FAKIRON KA NIWAN
360CPS SERWA
361Submersible Drain pumps of Minimum 3 m3/hr capacity @ 10 meters head at following locations:-
362RD 74 Km RWPS
363RWPS at Aleti
364Aleti HEAD WORKS
365IPS BAMARALA
366IPS PHAGALIYA
367IPS SOBHALA DARSHAN
368CPS SATA
369CPS FAKIRON KA NIWAN
370CPS SERWA
371Continuous type Electro chlorinator (1 working+1 standby) of suitable capacity (The capacity of Electro-chlorinator shall be minimum 2 kg/Hr, But the bidder has to work out the capacity of Electro-Chlorinator based on demand and tail end residual chlorine requirement of Minimum 0.2 ppm) including all required pipe fitting, accessories, valves, Brine Tank (HDPE material) of required capacity, level and Temperature sensors, pumps, Rotameter, Electrolyser, Hypo tank (HDPE Material), Blower, acid tank and pump, DC rectifier cum Control Panel and all required power and control cables complete for post chlorination/disinfection at following locations:-
372IPS BAMARALA
373IPS PHAGALIYA
374IPS SOBHALA DARSHAN
375CPS SATA
376CPS FAKIRON KA NIWAN
377CPS SERWA
378Electrical WORKS:-Design, Provide , Installation, Testing, Commissioningfor following as per Employer requirement and Specification (FromJdVVNL End toMotor Panel)
379Distribution Transformers (1W+1S) including all other accessories and protection devices complete at following locations with Minimum Rating (subject to as per design & ER):-
38033/6.6 KV at RD 74 Km RWPS
38133/0.415 KV at RD 74 Km RWPS
38233/0.415 KV at Aleti HEAD WORKS
38333/0.415 KV at IPS BAMARALA
38433/0.415 KV at IPS PHAGALIYA
38511/0.415 KV at CPS SATA
38611/0.415 KV at CPS FAKIRON KA NIWAN
38711/0.415 KV at CPS SERWA
38833/0.415 KV at CPS IPS SOBHALA DARSHAN
38933 KV, Switch board ( HT VCB panel ) withall required protection, equipment, Instrument, accessories, battery with charger, DCDBetc for 33/6.6 KV substation atFollowing Locations (subject to as per design & ER):-
390RD 74 Km RWPS
39133 KV, 630 Amp Switch board ( HT VCB panel ) withall required protection, equipment, Instrument, accessories, battery with charger, DCDBetc for 33/.44 KV substation atFollowing Locations:-
392RD 74 Km RWPS
393RWPS at Aleti
394Aleti HEAD WORKS
395IPS BAMARALA
396IPS PHAGALIYA
397CPS IPS SOBHALA DARSHAN
39811 KV, 630 Amp,Out Door type Ring Main Unit ( RMU ) including switch board HT VCB panel with 1 Incomer and 2 out going VCB withall required protection, equipment, Instrument, accessories, battery with charger, DCDBetc for 11/.44 KV substation atFollowing Locations:-
399CPS SATA
400CPS FAKIRON KA NIWAN
401CPS SERWA
402XLPE insulated H.T.cable for working voltage 33 KV from JdVVNL end point to HT panel and from Panel to transformer along with all necessary accessories,complete for following locations:-
403RD 74 Km RWPS
404Aleti HEAD WORKS
405RWPS at Aleti
406IPS BAMARALA
407IPS PHAGALIYA
408CPS IPS SOBHALA DARSHAN
409XLPE insulated H.T.cable for working voltage 11 KV from JVVNL end point to RMU and from RMU to transformer along with all necessary accessories, complete for following locations:-
410CPS SATA
411CPS FAKIRON KA NIWAN
412CPS SERWA
413Maintenance free gel earthing for Electricalsub stations (No. of earthings as per design requirements)asat following locations:-
414RD 74 Km RWPS
415Aleti HEAD WORKS & RWPS Aleti
416IPS BAMARALA
417IPS PHAGALIYA
418IPS SOBHALA DARSHAN
419CPS SATA
420CPS FAKIRON KA NIWAN
421CPS SERWA
422All civil works related to electric sub station including GSS lattice structure, if required,transformer foundation withdivide wall, oil collection sump, Piping, Chain link fencing with gates, Spreading of gravel in the sub Station areas, Civil works required for laying of cables( Trenching/ Trey) etc, for following location
423RD 74 Km RWPS
424Aleti HEAD WORKS & RWPS Aleti
425IPS BAMARALA
426IPS PHAGALIYA
427IPS SOBHALA DARSHAN
428CPS SATA
429CPS FAKIRON KA NIWAN
430CPS SERWA
431Design, Provide , Installation, Testing, Commissioningfor following as per Employer requirement and Specification (Onwards to Motor Panel)
432HT< switchgear housing two incomers ACBs,MCCBs,relays,metering system,CT,PT,Bus Bar,Bus Couplers etc.with requisite numbers of outgoing cubical to have Motor control unit with starters for all LT motors of main pumps, for electric actuators and Hoist, Main lighting distribution panel for inside as well as out side pump room, welding socket, spare cubicals,switchgear for DG system, complete in all respect for following location .
433RD 74 Km RWPS
434HT< switchgear housing two incomers ACBs,MCCBs,relays,metering system,CT,PT,Bus Bar,Bus Couplers etc.with requisite numbers of outgoing cubical to have Motor control unit with starters for all LT motors of main pumps, for electric actuators and Hoist, Main lighting distribution panel for inside as well as out side pump room, welding socket, spare cubicals,switchgear for DG system, complete in all respect for following location .
435RD 74 Km RWPS
436Aleti HEAD WORKS
437RWPS at Aleti
438IPS BAMARALA
439IPS PHAGALIYA
440IPS SOBHALA DARSHAN
441CPS SATA
442CPS FAKIRON KA NIWAN
443CPS SERWA
444APFC Panel with Capacitor Bank at following Pumping Station
445RD 74 Km RWPS
446Aleti HEAD WORKS
447RWPS at Aleti
448IPS BAMARALA
449IPS PHAGALIYA
450IPS SOBHALA DARSHAN
451CPS SATA
452CPS FAKIRON KA NIWAN
453CPS SERWA
454Local push button station for pump motors, actuators, HoistAt all locations of Pumping Station
455RD 74 Km RWPS
456Aleti HEAD WORKS
457RWPS at Aleti
458IPS BAMARALA
459IPS PHAGALIYA
460IPS SOBHALA DARSHAN
461CPS SATA
462CPS FAKIRON KA NIWAN
463CPS SERWA
464110V DC system with batteries, battery charger, DC DB in panel to operate spring charging motors and LED supply on LT panel At followingpumping station .
465RD 74 Km RWPS
466Aleti HEAD WORKS
467RWPS at Aleti
468IPS BAMARALA
469IPS PHAGALIYA
470IPS SOBHALA DARSHAN
471CPS SATA
472CPS FAKIRON KA NIWAN
473CPS SERWA
474LT cable withAccessories, cable trays/Trenchingfor motors and all Electrical equipments to be provided in Head works at FollowingLocations
475RD 74 Km RWPS
476Aleti HEAD WORKS
477RWPS at Aleti
478IPS BAMARALA
479IPS PHAGALIYA
480IPS SOBHALA DARSHAN
481CPS SATA
482CPS FAKIRON KA NIWAN
483CPS SERWA
484Exhaust Fans, Pedestal type air circulator, other ventilating arrangement for Following Pump Station
485RD 74 Km RWPS
486Aleti HEAD WORKS
487RWPS at Aleti
488IPS BAMARALA
489IPS PHAGALIYA
490IPS SOBHALA DARSHAN
491CPS SATA
492CPS FAKIRON KA NIWAN
493CPS SERWA
494Earthing system for LV systems and motors installed in the contract in the Head works At
495RD 74 Km RWPS
496Aleti HEAD WORKS
497RWPS at Aleti
498IPS BAMARALA
499IPS PHAGALIYA
500IPS SOBHALA DARSHAN
501CPS SATA
502CPS FAKIRON KA NIWAN
503CPS SERWA
504All Solar based Pumping Stations
505Diesel generating set of respective minimumcapacity including all associated accessories for lighting load At following locations:-
50662.5 KVA at Aleti Headworks & RWPS Aleti
50725 KVA atRD 74 Km RWPS
5085KVA at IPS BAMARALA
5095KVA at IPS PHAGALIYA
5105KVA at IPS SOBHALA DARSHAN
5115KVA at CPS SATA
5125KVA at CPS FAKIRON KA NIWAN
5135KVA at CPS SERWA
514Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.
5157 Mtr.
516P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning Hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. LED street light fixture 150 watt
517RD 74 Km RWPS
518Aleti HEAD WORKS
519RWPS at Aleti
520IPS BAMARALA
521IPS PHAGALIYA
522IPS SOBHALA DARSHAN
523CPS SATA
524CPS FAKIRON KA NIWAN
525CPS SERWA
526All Solar based Pumping Stations
527BILL 5- Instrumentation
528Setting up of Master Control Station (MCS) : Complete Automization, PLC and SCADA system including central processing unit, memory unit, Input/Output modules, requisite hardware and software, Communication system, Instrument Control Panel (I.C.P.) / Control Desk, (MMI) consisting of required Personal Computers with colour monitors, printers, UPS, all transducers and transmittersetc. SCADA software and its installation with required software, complete in all respect including air conditioners at WTP AletiAdministrative Buildingas per General and Particular Specifications and Employer"s requirement
529Setting up of Local Control Station (LCS): Complete Automization, PLC and SCADA system including central processing unit, memory unit, Input/Output modules, requisite hardware and software,Instrument Control Panel (I.C.P.) / Control Desk, MMI), consisting of one Personal Computer with printers, UPS, all transducers and transmitters, communication or internet Systemetc. SCADA software and its installation with required software complete in all respect at following locations as per General and Particular Specifications and Employer"s requirement
530RD 74 Km RWPS
531Aleti HEAD WORKS
532RWPS at Aleti
533IPS BAMARALA
534IPS PHAGALIYA
535IPS SOBHALA DARSHAN
536CPS SATA
537CPS FAKIRON KA NIWAN
538CPS SERWA
539AT BARMER
540At CHOUHTAN
541Setting of remote Station and instrumentation control panel including all necessary hardware and software, instrumentation and control cable of LT power Cabling, LT Panel, Battery backup and UPS with 2 hrs battery backup complete for transferring the data as well as operation and control through SCADA of Flow Control Valves from Local/Master control Station (These are such where power connection is going to be available viz. near inlet of ESR having FCV).
542Setting of remote Station including all necessary hardware and software, instrumentation, with solar power system, Battery backup complete for transferring the data to LCS and MCS (These are such where power connection is not going to be available viz. near inlet of ESR not having FCV plus Village Transfer Chambers & solar PS CWR).
543Providing, Installation, testing, commissioning of Following Instrument as per Employer requirement and Specifications:-
544for the WTP
545Ultrasonic flow meters with transmitterfor inlet and outlet channels with all accessories
546Bulk flow meters for air pipe and wash water pipe with all accessories
547Mechanical flow measuring system withall accessories at the parshall flume
548Ultrasonic type level sensor, transmitter with switch in the sump for atomisation of backwash pump.
549Ultrasonic type level sensor,transmitter with level switch in backwash tank for atomisation of backwash pump
550External cage type magnetic level sensors, transmit orwith switches in all solution tanks of Alum/PAC, lime and sludge thickening compound for automisationof dosing pumps
551Sensors , Transmitter forDifferential Head across Filter Beds
552PH meter with transmitterfor continuous monitoring at inlet and outlet
553Continuous turbidity meter withtransmitter at inlet and outlet
554Continuous Residual Chlorine sensorwith transmit or at the outlet
555Portable pH meter, Chlorine Sensor and turbidity meters
556IACC Panel with a automation components such as PLC and associated Digital Input/output subsystems, power supply unit, switches, indicators etc., along with Local SCADA Systemat following locations:-
557RD 74 Km RWPS
558Aleti HEAD WORKS
559RWPS at Aleti
560IPS BAMARALA
561IPS PHAGALIYA
562IPS SOBHALA DARSHAN
563CPS SATA
564CPS FAKIRON KA NIWAN
565CPS SERWA
566at BARMER
567At CHOUHTAN
568Control cables, cable trays, support, Accessories, Glands, Work tocompletein all respectat following locations:-
569RD 74 Km RWPS
570Aleti HEAD WORKS
571RWPS at Aleti
572IPS BAMARALA
573IPS PHAGALIYA
574IPS SOBHALA DARSHAN
575CPS SATA
576CPS FAKIRON KA NIWAN
577CPS SERWA
578at BARMER
579At CHOUHTAN
580UPS / Invertors with 2 hrs battery backup to supply power to all Instrumentation system, completeat following locations:-
581RD 74 Km RWPS
582Aleti HEAD WORKS
583RWPS at Aleti
584IPS BAMARALA
585IPS PHAGALIYA
586IPS SOBHALA DARSHAN
587CPS SATA
588CPS FAKIRON KA NIWAN
589CPS SERWA
590BARMER CR
591CHOUHTAN CR
592Solar based Pumping Stations
593Pressure Gauges at individual delivery and Headerat following Pumping Stationlocations:-
594RD 74 Km RWPS
595Aleti HEAD WORKS
596RWPS at Aleti
597IPS BAMARALA
598IPS PHAGALIYA
599IPS SOBHALA DARSHAN
600CPS SATA
601CPS FAKIRON KA NIWAN
602CPS SERWA
603Solar based Pumping Stations
604Ultrasonic level indicators with Sensor andSwitches atsump,Pressure Sensors, Transmitters andSwitches on delivery header, Temperature sensors with transmitterfor motors, with all required components and associated erection hardware as well as accessories as per the requirements at following Pumping Stationlocations:-
605RD 74 Km RWPS
606Aleti HEAD WORKS
607RWPS at Aleti
608IPS BAMARALA
609IPS PHAGALIYA
610IPS SOBHALA DARSHAN
611CPS SATA
612CPS FAKIRON KA NIWAN
613CPS SERWA
614FOR RESERVOIRS
615Ultrasonic Level Indicator, transmitter, Sensor with all required components and associated erection hardware as well as accessoriesat following CWR locations:-
616RWPS
617Aleti HEAD WORKS
618IPS BAMARALA
619IPS PHAGALIYA
620IPS SOBHALA DARSHAN
621CPS SATA
622CPS FAKIRON KA NIWAN
623CPS SERWA
624Ultrasonic Level Indicator, transmitter, Sensor with all required components, with solar power supply & battery backup system and associated erection hardware as well as accessoriesat following ESR/CWR locations:-
625AT all ESRs
626AT all solar powered PS CWRs
627Electro-magnetic flow meters, transmitter, flow Integrator ( Digital display in Instrument Panel in Control Room) with required specials, fittings, supports etc.. complete in all respectof following NB:-
628100 mm dia
629125 mm dia
630150 mm dia
631200 mm dia
632300 mm dia
633350 mm dia
634400 mm dia
635450 mm dia
636500 mm dia
637700 mm dia
638700 mm dia
639900 mm dia
6401000 mm dia
6411200 mm dia
642Battery Operated Woltman type In-Line flow meters with GSM/GPRS based communication model, battery with accessories, fittings, valves (upstream and downstream to the Flow meter), dismantling joints, Air valves, specials, pressure gauge, anchor block, supports,complete in all respect at all VTC (Size of flow meters shall vary from 80mm to 200 mm as per minimum flow velocity requirement of flow meter)
643Electronic Sound level Meter, Electronic virabation meter & Electronic Temparature meter and any other instuments/items/tools required for smooth running & daily monitoring/ routine maintenance of pump motors/headworks other than specified in BOQ.
644RD 74 Km RWPS
645Aleti HEAD WORKS & RWPS Aleti
646RWPS at Aleti
647IPS BAMARALA
648IPS PHAGALIYA
649IPS SOBHALA DARSHAN
650CPS SATA
651CPS FAKIRON KA NIWAN
652CPS SERWA
653BILL 6- VILLAGE DISTRIBUTION
654Survey, Design, Construction, Testing, Commissioningof circular RCC Clear Water reservoirs includingDI D/F inlet with manually operated Sluice Valve, dismantling joints, outlet with flange and blind flange, overflow with requiredpiping up to thechamber and up to storm water drain, washout pipe with sluice valves, construction of chambers complete in all respect of various capacitiesfor village Distribution as per Employer requirement and General Specification
65520 KL to 100 KL
656101 to 200 KL
657201 to 300 KL
658Providing, installation, testing and commissioning of AC submersible/ monoblock pump sets with HDPE/GI/MS/DI pipe fittings andindividual solar pump controller (1w+1s)with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps. Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The entire work shall be executed as per technical specification and direction of Engineer in charge.
659up to 5 HP
6605 HP to 7.5 HP
6617.5 HP to 10 HP
6622.17/Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere Mtr, volt Mtr, phase preventer,phase indicators, lighting arrangement etc complete suitable for three phase pump Set. The panel should have space for energy Mtr ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy Mtr with glass for Mtr reading. The operation of panel should be suitable for on 440 Volt AC Supply.
663Up to 5.00 HP
6642.18/Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere Mtr with CTs, volt Mtr, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump Set. The panel should have space for energy Mtr ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy Mtr with glass for Mtr reading. The operation of panel should be suitable for on 440 Volt AC Supply.
665Above 5 HP and up to 20 HP
666Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
6673 core 4.0 Sq.mm
668Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area, MS fabricated structure 120 micron hot dip galvanized iron, fencing, showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document.
669Construction of Pump House in Stone/Brick Masonry of min. 2.5m x 2.5m size,pump house buildingto accommodate SOLARpump & panel & controller sets,with associate Electrical / Plumbing work. Thisshall includeCivil works required for erection of chainpulley and Supply & fixing of chanipulley 2MT,installation of pumps and panels, cable trenches, drainage, access platforms, ladders, thrust/anchor blocks, pipe supports, Pipes and specials, rain water harvesting & collectionsystem for rain water frompump house roofto thesumpcomplete in all respect as per employer"s requirement and Specifications at following location
670Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer Mtr/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (muram/soft rock/hard rock) including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 Mtr ; providing & fixing of all fittingusing PP mechanicalIntegrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , notexceedingtheflowof7LPMat2barandacompressionelbow, moulded in single piece/ fusion welded (Complete job). providing & fixing of all fitting duly approvedinaccordancewith specificationforpotablewaterincluding GMFull-wayValve(IS:778Mark)orwheelvalveandspecialswith20 mmnominaldiaMDPEpipePE 80PN16asperISO4427/20mm nominaldia PPR-C (Three layered) pipe PN16SDR 7.4 (IS:15801:2008) (ISImark)andabovegroundlevelusingPPR-CpipewithstandardPPR fittings/ GI pipes in the premises for fixing a tap. P&F a Bib Cock (IS : 8931 Mark) superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer"s property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm. Including Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum required strength of 8 Kg/sq.cm. The raw material shall be Food grade quality.Pressure rating shall be 12.5 Bar. The pipes shall bear ISO marking.
671Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe
672Extra length of 20 mm MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
673BILL 7 - Civil AND ANCILLARY WORKS
674Construction of Office Building (Minimum Area 1830 Sqft) with furniture including air conditioners as per Employer requirement, Specification and tender drawings.
675Construction of J-2 Type Set (Twin quarter) at various headworks as per Employer requirement, Specification and tender drawings
676Construction of Engineer residence including air conditioners as per Employer requirement, Specification and tender drawings
677Campus area Development Works bylandscaping, Horticulture, Drainage, External campus lightingetc and any other item other than specified in BOQ. as per Employer requirement and Specification at following Campuses:-
678RD 74 Km RWPS
679Aleti HEAD WORKS
680IPS BAMARALA
681IPS PHAGALIYA
682IPS SOBHALA DARSHAN
683CPS SATA
684CPS FAKIRON KA NIWAN
685CPS SERWA
686Construction of Boundary wall, installation of MSGates (Man and Animal Obstruct with Minimum Weight 450 Kg ) and Approach Roads as per Employer requirement and Specification for various PS head works, ESR campuses, VD CWRs etc.
687Boundary Wall
688MS Gates
689Cement Concrete roads within campuses
690Gravel roads for approach to ESRs
691Construction of HT/ LT/ switchyard panel Room with all facilities (Minimum plinth area 25 Sqmtr) asper Employer requirement and Specification
692Construction of Store builindg with all facilities (Minimum Area 50 Sqm with on side Kota stone shelves 1.0m deep from top to ground level on a long wall) as per Employer requirement and Specification
693Construction of Local Control Station with all facilities (LCS) building of minimum 30 sqm area complete in all respect including air conditionersas per Employer requirement and Specificationat Barmer & Chouhtan
694Construction of Village Transfer chamber (VTC)complete in all respect as per the tender drawing,complete in all respect as per Employer requirement and Specification.
695BILL 8 - SPARE PARTS, TOOLS AND TACKLES
696Supply of spares for mechanical works for all pumping stations as per scope of work and specifications given.
697Supply of spares for electrical works for all pumping stations as per scope of work and specifications given.
698Supply of spares for instrumentation works as per scope of work and specifications given.
699Supply of spares for pipeline works as per scope of work and specifications given.
700Supply of tools and tackles as per scope of work and specifications given.
701Supply of retractable aluminum ladder 4.5m length at all PS
702BILL 9 - PRICE SCHEDULE-OPERATION & Maintenance SERVICE(SECTION II)
703OPERATION & MAINTENANCE SERVICE AFTER DEFECTS LIABILITY/NOTIFICATION PERIOD OF ONE YEAR
704Operation and Maintenance (AFTER DEFECTS LIABILITY/NOTIFICATION PERIOD OF ONE YEAR) ofPipeline up to VTC, CWRs, ESRs, pump houses,WTP, EMI Works, include all type of materials/chemicals/fuel (disinfactant/chlorine gas, & coagulant/PAC/Alum, etc) required for O&M service,Electro chlorinators at pumping stations etc of the whole WSS system/works (except Jdvvnl electricity bill /charges & WRD canal water bill/ charges ) as per Employer requirement and Specification for:-
7051st Year
7062 rd Year
7073 rd Year
7084 th Year
7095 th Year
7106 th Year
7117 th Year
7128 th Year
7139 th Year
71410 th Year
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail