| 1 | Taking down cement /terrazo plasterof any description from brick wall or concrete surfaceincluding racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed. |
| 2 | M & L for providing 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone agg finished even and rough as in toping layer for laying floor tiles complete all as specified and directed. |
| 3 | Roughening of existing surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engr-in-Charge. |
| 4 | M & L for 20-22 mm thick kota stone slab as in floor, machine cut bedded and jointed and pointed with grey cement slurry including cutting and mirrorpolishlaid with 3.0 kg of cement per sq. metre over & including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 5 | All as per srl item No 4.00 (here-in-above) but in vertical surface such as skirting, dado and pillar laid with 3.0 kg of cement per sq. metre over & including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 6 | Marble work 20 mm thick (550mm long X 75mm wide strip) as in border in flooring,over 20 mm thick screedin CM (1:4)including pointing in white cement (1:2) using marble dust with admixture of pigments to match with white marble including rubbing, grinding and polishing complete all as specified and directed. |
| 7 | M & L for 62 cm wide Udaypurstone 15 to 18 mm thick. (table rubbed and polished) as in cooking platformof size notless than 2 m in length, incl cutting for sink over prepared surfaceand pointing with white cement 1:2 using marble dusts admixture of pigment to match. |
| 8 | M & LBrick work with sub class “B” bricks straight or curved on plan exc 6M mean radius build in CM 1:6 using complete all as specified and directed using old size bricks. |
| 9 | M & L for 15mm thick cement plaster in CM 1:6 finished even and smooth w/o using extra cement on other than fair faces of brick work complete all as specified and directed. |
| 10 | M & L for 15 mm thick cement plaster in CM 1:4 in two layers first coat of 10 mm thick and second coat of 5 mm thick using WPC finished even and smooth w/o using extra cement on fair faces of brick work complete all as specified and directed. |
| 11 | PCC 1:2:4 type B-0 (Using 12.5mm graded curshed stone aggreegates) as in benching, coping, roof kerbs, mud stop etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc. complete as specified and directed. |
| 12 | PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection ( 50mm thick ) finished even and fair complete all as specified and directed. |
| 13 | RCC 1:2:4 type B-1 (using 20mm graded crushed stoneagg) as in chajjas, shelvesand similar items complete all as specified and directed. |
| 14 | RCC 1:2:4 type B-1 ( using 20mm graded crushed stone agg) as in fins , fascias, parapets and similar items complete all as specified and directed. |
| 15 | Form work to chajjas troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and directed. |
| 16 | Form work to side and soffits of floor beam, lintels cantilevers shelves including supports over hangs etc. for rough finished surfaces of concrete flat complete all as specified and directed. |
| 17 | Form work to edges of concrete flats RCC/PCC band exc 5 cm butnot exceeding 10 cm for rough finished surfaces of concrete flat complete all as specified and directed. |
| 18 | TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending and spirally hoping for columns hooking ends and binding with MS wire annealed n.less then 0.90mm dia. |
| 19 | All as per serial No. 18.00 (here in above) but 6mm to 8mm dia -ditto complete all as specified and directed. |
| 20 | M & L 5 mm thick cement plaster in CM 1:3 on ceiling concrete surface facia chajja roof projection etc finished even and smooth w/o using extra cement complete all as specified and directed. |
| 21 | S & F 25mm dia aluminum anodised depreved rod, powder coated, teak wood textured finish and wall thickness 1 mm complete designed and patterned as approved by Engr-in-Charge complete all as specified and directed. |
| 22 | S & F Soild PVC single rebate door frame of size 50mm x 47mm made out of 5mm but single side prelam PVC sheet reinforced with MS tube supplying & fixing in opening as per specification & drawings complete all as specified and directed. |
| 23 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having aPVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail penelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings complete all as specified and directed. |
| 24 | S & F100mm long butt hinges(medium weight) colled rolled mild steel fixed with welding complete all as specified and directed. |
| 25 | S & F Aluminum handles, cost type anodized150 mm size complete all as specified and directed. |
| 26 | S & F Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 27 | M &L PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as specified and directed. |
| 28 | S & F Vitreous china squatting pan “Orissa” pattern of size 630mm with ‘P’ or ‘S’Trap front or back inlet and foot rest any pattern (excluding flushing cistern and flush pipe) complete including cast iron ‘P’ or ‘S’ trap complete all as specified and directed. |
| 29 | M&L two coats of oil bound distemper over one coat of primer including preparation on new plastered surface ofwall surface over a coat of wall care putty complete all as specified and directed. |
| 30 | Complete removal ofexisting treatmentand applying two coats of oil bound distemper over one coat of primerincluding preparation of old plastered surfaces on wall over a coat ofwall care putty complete all as specified and directed. |
| 31 | M&L two coats of white wash including preparation of new plastered surfaces of wall complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L two coats of white wash onwalls incl preparation of old plastered surfaces complete all as specified and directed. |
| 33 | M&L two coats of white wash on ceiling surfaces incl preparation of new plastered surfaces complete all as specified and directed. |
| 34 | M&L two coats of white wash on ceiling surface incl preparation of old plastered surfaces complete all as specified and directed. |
| 35 | M&L two coat of cement base paint over a coat of primerincluding preparation of new plastered or unplastered surfaces of wall over a coat of wall care putty complete all as specified and directed by Engr-in-Charge. |
| 36 | Complete removal ofexisting treatmentand applying two coats of cement base paintover a coat of alkali resistance primer including preparation of old surfaces of wall over a coat of wall care putty complete all as specified and directed by Engr-in-Charge. |
| 37 | Taking down steel tubing 15 mm bore and connections,including cleaning for refixing or removal to store complete all as specified and directed. |
| 38 | Taking down steel tubing 20 mm bore and connections,including cleaning for refixing or removal to store complete all as specified and directed. |
| 39 | S&F 15 mm bore GI tubing mediumgrade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 40 | S&F 20 mm bore GI tubing mediumgrade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 41 | Demolition of cement concrete in floor/pavings including terrazzo floor/tiles of any description not exceeding 15cm thickness below or above GL and removing debris from the premises. |
| 42 | Cutting chases in bk wall for concealed water tubing exc 10 cm but n exc 20 cm girth and making good complete all as specified and directed. |
| 43 | Refixing old steel tubing 15 mm bore and connections in new or old position complete all as specified and directed. |
| 44 | Refixing old steel tubing 20 mm bore and connections in new or old position complete all as specified and directed. |
| 45 | S & F Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe , brackets and 32mm dia bore CP coupling complete as in repairs complete all as specified and directed. |
| 46 | S & F PVC valveles, symphonic action type, flushing cistern low level 10 ltr, white with inlet, ball valve, float and handle in fixed in repair complete all as specified and directed. |
| 47 | S & F Stainless steel plate rack of Size 78.74 cm x 76.2 cm x 25.4 cmcomplete all as specified and directed by Engr-in-Charge. |
| 48 | S & F 600x450 mm PVC frame beveled edge looking mirror of selected quality glass and fixed with wooden plugs as in repairs complete all as specified and directed. |
| 49 | S & F Soap dish vitreous china white, size 160X160X90mm fixed in repair complete all as specified and directed. |
| 50 | S & F 15 mm bore Concealed stop cock fancy type CP with long shank and cup washer as in repairs complete all as specified and directed. |
| 51 | S & F Angle stop cock fancy type CP with long shank 15mm bore as in repairs complete all as specified and directed. |
| 52 | S & F Brass CP shower rose 75mm size with swirel joint as in repairs complete all as specified and directed. |
| 53 | S & FFancy type bib tap brass CP ( Long body) 15mm bore as in repairs complete all as specified and directed. |
| 54 | S & F 15 mm bore CP Pillar taps, fancy type cast copper alloy, with capstan heads, screwed down high pressure, without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 55 | S & F Aluminium Wardrobe hook set of three 50 mm to 60 mm complete all as specified and directed. |
| 56 | S & F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as specified and directed. |
| 57 | S & F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed. |
| 58 | S & F CP grating 125mm dia as in repairs with or w/o circular hole for inserting waste pipe complete all as specified and directed. |
| 59 | S & F PVC connection 15mm bore with PTMT nuts and washer 45cm long as in repairs complete all as specified and directed. |
| 60 | S & F CP connection with nuts and washers brass CP as in repairs 600 mm long complete all as specified and directed. |
| 61 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc., etc. and hoisting , reconnecting and re-fixing in position 250 to 500 ltr capacity complete all as specified and directed. |
| 62 | S & F in repair 20mm bore stop valves cast copper alloy screwed down each high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 63 | S & Fin repair 15mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe for union complete all as specified and directed. |
| 64 | Taking down existing AC/PVC pipes (any size or patern ) including all fittings complete all as specified and directed. |
| 65 | Dismantiling cast iron pipes up to 100 mm dia including fitting taking out ortrenches of walls as required complete all as specified and directed. |
| 66 | S & FPVC (SWR) pipe single socketed in any length with rubber ring socket ring joints fixed to walls 110mm diacomplete all as specified and directed. |
| 67 | S & F PVC (SWR) bends/shoe for 110mm bore complete all as specified and directed. |
| 68 | S & F Cast iron soil waste and vent pipes in any length with or w/o ears with cement joints fixed to walls or laid intrenchesfor sand cast pipe100mm bore complete all as specified and directed. |
| 69 | S & F 75mm bore cast iron soil waste and vent pipes in any length with or w/o ears with cement joints fixed to walls or laid intrenchesfor sand cast pipe complete all as specified and directed. |
| 70 | S & F 75mm bore cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and directed. |
| 71 | M & L for coloured printed non-skidceramic tiles 400x400x7mm thick in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match including a coat of neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directed. |
| 72 | M & L for 10 mm thick cement plaster in CM 1:4 on fair faces of brick work of concrete surface ( for laying wall tiles) finished surface fair and even complete all as specified and directed. |
| 73 | Material and labour for coloured glazed designer ceramic tiles glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchcoloured tiles complete all as specified and directed. |
| 74 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 75 | Removing excavated material to a distance n exc 50 Mand depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 76 | Taking down carefully aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc,removing materials to store, or keeping in safe custody foroffering credit (credit for above items should be made as per conditions separately) andmaking good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 77 | Material & Labour for point wiring complete with1.5 sqmm (Nominal area) single core FRLS PVC insulated, unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metallic rigid PVC conduit of appropriate size andaccessories consealed to wall, surface on ceiling etc., and including provision of 1.5 sqmm copper wire green colour as earth continuity conductor and connected to common earth dolly, and sunken box or pressed steel terminal boxes with provision of new 3 mm thick plastic laminated sheet top cover for housing the switches ,socket outlets, fan regulators etc. with steel screws and steel washers complete all as specified and as directed for the follwing:- Note :- Cutting chases for conduits and sinkings for boxes and making good to wall, floor etc for concealed wiring deemand to be including in unit rate. |
| 78 | One light point /Exhaust/Ceiling Fan point controlled by one switch. |
| 79 | One Bell Point controlled by one Bell Push |
| 80 | One switch socket outlet point 3 pin 5 Amps on Independentboard. |
| 81 | One switch socket outlet point 3 pin 5 Amps on same board. |
| 82 | Material & Labour for Point wiring complete with 2.5 sqmm (Nominal area) single core FRLS PVC insulated, unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metallic rigid PVC conduit of appropriate size andaccessories consealed to wall, surface on ceiling etc., and including provision of 2.5 sqmm copper wire green colour as earth continuity conductor and connected to common earth dolly, and sunken box or pressed steel terminal boxes with provision of new 3 mm thick plastic laminated sheet top cover for housing the switches ,socket outlets, fan regulators etc. with steel screws and steel washers complete all as specified and as directed for the follwing:- Note :- Cutting chases for conduits and sinkings for boxes and making good to wall, floor etc for concealed wiring deemand to be including in unit rate. |
| 83 | Material & Labour for Point wiring complete with 4.0 sqmm (Nominal area) single core FRLS PVC insulated, unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metallic rigid PVC conduit of appropriate size andaccessories consealed to wall, surface on ceiling etc., and including provision of 4.0 sqmm copper wire green colour as earth continuity conductor and connected to common earth dolly, and sunken box or pressed steel terminal boxes with provision of new 3 mm thick plastic laminated sheet top cover for housing the switches ,socket outlets, fan regulators etc. with steel screws and steel washers complete all as specified and as directed for the follwing:- Note :- Cutting chases for conduits and sinkings for boxes and making good to wall, floor etc for concealed wiring deemand to be including in unit rate. |
| 84 | Supply and fix switch piano 5 Amps flush type one way complete all as specified and directed. |
| 85 | Supply and fix switch piano 15 Amps flush type one way complete all as specified and directed. |
| 86 | Supply and fixsocket outlet 3 pin 5 Amps multi pin flush type complete all as specified and directed. |
| 87 | Supply and fixsocket outlet 3 pin 15 Amps multi pin flush type complete all as specified and directed. |
| 88 | Supply and fix ceiling rose surface bakelite 65x50mm 3terminals complete all as specified and directed. |
| 89 | Supply and Fixing ofPVC Lamp holder Insulated body bracket holder /angle holder complete all as specified and directed. |
| 90 | S/F Bell Push flush type complete all as specified and directed. |
| 91 | S/F CallBell AC 230 V Single Pole and including taking down old/unsv calling bell complete all as specified and directed. |
| 92 | S&F LED light fittings 1X18W,220V, AC decoretire, box type with driver, holder including LED tube light connecting upto with three core flexible copper conductor cable of suitable size from celling rose complete all as specified and directed. |
| 93 | Supply and fix bulb LED 9 watt 240 volt complete all as specified and as directed. |
| 94 | Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 95 | Supply and fix fan speed regulator, electronic steptype, suitable for single phase AC, 240 volts, 50 Hz, 100 watts all as specified and as directed complete all as specified and directed. |
| 96 | M&L sub main wiring complete with two runs of6.0sqmm single core PVCinsulated heavy duty ISI Marked , unsheathed cable1100 volts grade, multistranded with copper conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories Concealed /fixed to walls / roofs / floors etc.,and including provision ofPVCinsulated heavy duty ISI Marked , unsheathed cable1100 volts grade6.0sqmm forearth continuity conductor including taking out old unsv and making good the disturbed surfaces alsomatching the exisiting surfacesall as specified and as directed. Note :- Cutting chases for conduits and sinkings for boxes and making good to wall, floor etc for concealed wiring deemand to be including in unit rate. |
| 97 | Disconnecting from mains and Taking down old unsv sheet metal enclosures of MCBany type and capacity including unsv MCBs complete all as specified and directed. |
| 98 | Supply and fixing in replacement double door sheet metal enclosures 4 way TPN, vertical distribution board 200 Amps rated bus bar blanking plate duly flush in wall, double door IP 54 protection as per IS 8623-III with and including MCCB 100 Amps 4 pole as incomer of 16 KA -01 No and making good disturbed surface as existing complete all as specified and as directed. |
| 99 | Supply and fix sheet metal enclosures forMCB distribution board 240 voltssinglepole and neutral 8 way single door flushed inside the wall with 100 Amps rated busbar including making good the disturbed surfaces alsomatching the exisiting surfaces completeall as specified and as directed. |
| 100 | Supply and fix MCBSingle pole & neutral 240 volts, 5 to 63 Amps, \"C\" curve 10 KAcomplete all as specified and as directed. |
| 101 | Supply and fix MCB single pole, 240 volts, 6 to 32 Amps, \"C\" series 10 KA complete all as specified and as directed. |
| 102 | Supply and layingin trenches / fixing in wall or pole etc., of XLPEinsulted armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sq mm 4.0corecomplete all as specified and directed. |
| 103 | Earthing complete with galvanized steel earth plate electrode 60cm x60cmx6.00mm thick, buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level, filled around with layer of char coal dust and salt and connected to GI earth wire 4.00 mm by means of bolt , nut and check nuts and washers ofgalvanized iron or steel and other end of the earth strip, connected to test point /equipment/panel and protected by galvanized iron pipe light grade 15 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1: 3 : 6 in chambers , RCC 1:2:4 in pit cover reinforced with 8mm dia deformed bars @ 15cm center to center both way including necessary excavation & earth work as directed by Engr-In-Charge, complete all as shown in electric plate No-5 of SSR part-I of 1991. .PCC chambers shall be constructed at leats 1.5 mtr away from the earth electrode and pipe for watering complete all as specified and directed. |
| 104 | Supply & fixing GI pipe light grade 50 mm dia used for protection of pipe including MS clamps, nuts, bolts etc complete all as specified and as directed. |
| 105 | Dismantling house serviceable bracket any type complete all as specified and directed. |
| 106 | Dismantling/taking down old unserviceable service cable of any size complete all as specified and directed. |
| 107 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50 m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/loose of soil including forming bottom surface to required level and slope complete all as specififed and directed. |
| 108 | Returing, filling including spreading, leveling, watering and well ramming in layers not exe 2.5 cm soil complete all as specified and directed. |
| 109 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 110 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and Part II) for protection of underground cables 90mm outer dia with all fittings, laid in trenches/road/nallah or fixed along wall. Poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection complete all as specified and directed (excavation and earth work shall be measured and paid separately) Make : Rex/Poly/Gemini |