Tender For Repairs / Maintenance To External Electrification System Oh Ht And Lt Lines Ug Cables Apfc Panels And Allied Works At Caw Area And Af Officers Residential Accn Under Ge Af Hakimpet, hakimpet-Telangana

Military Engineer Services-MES has published Tender For Repairs / Maintenance To External Electrification System Oh Ht And Lt Lines Ug Cables Apfc Panels And Allied Works At Caw Area And Af Officers Residential Accn Under Ge Af Hakimpet. Submission Date for this Tender is 25-09-2023. Electrification Work Tenders in hakimpet Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

39209569
Corrigendum : Tender For Repairs / Maintenance To External Electrification System Oh Ht And Lt Lines Ug Cables Apfc Panels And Allied Works At Caw Area And Af Officers Residential Accn Under Ge Af Hakimpet
Open Tender
Indian
Telangana
hakimpet
25-09-2023

Tender Details

Tender For Repairs / Maintenance To External Electrification System Oh Ht And Lt Lines Ug Cables Apfc Panels And Allied Works At Caw Area And Af Officers Residential Accn Under Ge Af Hakimpet

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-09-2023
2 19-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

BOQ Items

Name of Work :-REPAIRS / MAINTENANCE TO EXTERNAL ELECTRIFICATION SYSTEM OH HT AND LT LINES UG CABLES APFC PANELS AND ALLIED WORKS AT CAW AREA AND AF OFFICERS RESIDENTIAL ACCN UNDER GE AF HAKIMPET
Sl. No. Item Description
1Dismantling damaged PCC poles / steel tubular poles/struts of any size complete and supply & errect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion complete all as specified and as directed.
2Taking down unserviceable gang operated switch and Supply and fix switch air break, gang operated, triple pole, mechanically operated, vertical type,with polymer insulators, mounted onsteel frame, with operating mechanism worked from ground level for current rating upto 400 Amps suitable for 11000 volts grade complete all as specified and as directed.
3Dismenttling and Removing the unserviceable 11 KVexpulsionfuse single pole carefully from 2/4 pole structure and S&F Expulsion drop out fuse / horn gap fuse Single pole alongwith post top insulator suitable for11KV including connecting the same to the supply with necessary fixing material suchasaluminiumjumpers ,binding wire etc complete all as specified and as directed.
4Servicing of gang operated switch on Two / four pole structure at elevated height and replacing unserviceable components like knife, connecting copper strip, nut, bolts & washers of GI/brass as and providing suitable lubrication to component ofswitch air break, gang operated, triple pole, vertical or horizontal type mechanically operated for current rating upto 200/400 Amps suitable for 11000 Volts grade complete all as specified and as directed.
5Taking down unserviceable HT UG cable and Supply, laying, connecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (earthed) ofcross sectional area 95 Sqmm 3 core complete all as specified and as directed.
6Dismantling unserviceableinsulators and M&L for pin type, porcelain, vitreous, white, brown or green insulators including one galvanised mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed.
7Dismantling unserviceable insulators and M&L disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball & socket type, white, brown or green with tension clamps for conductors working pressure 11000 volts, grade for single disc assembly complete all as specified and as directed.
8Dismantling old unserviceabl ACSR conductor and M&L for ACSR conductor in OH lines of HT/ LT/ street light conductor (Squirrel / Weasel) including binding with aluminium wire, in between every span complete all as specified and as directed.
9Taking out unserviceablLightning arrestorSupply and Fix Lightning arrestor11 KV Non linear type , MCOV 12KV , 10KA Discharging capdistribution class complete all as specified and as directed.
10M&L for painting of 4 pole structure consisting of 11 mtr swaged steel tubular poles complete with cross arm, brackets, claps etc with one coat of aluminium paint including preparation of old painted surfaces and pasting radium stickets /paint with 3 line around the pole and umbering of pole with synthetic enamel paint on black base complete all as specified and as directed
11Description all as per Ser item No 10 above buttwo pole structure complete all as specified and as directed.
12M&L for painting the external exposed surfaces of steel tubular sewaged/ rail pole of 9/11 mtrs long alongwith cross arm, brackets and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and pasting radium red stickers / paint with 3 line around the pole and numbering of pole with synthetic enamel white paint on black base complete all as specified and as directed.
13M&L for loose filling with aggregate of gauge 40 to 50 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface of transformer and two pole / four polestructure complete all as specified and as directed.
14S&Fin repair Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size as indicated or as directed inclusive of one primer coat, one under coat and finishing coat of aluminium paint complete all as specified and as directed , incl taking out old rusted channels from 2 pole /4 pole structures complete all as specified and as directed.
15Servicing of HT,VCB / SF6 CB, relays including calibration of IDMTL relays through primary and secondary injection method and testing complete re-setting where required and ensuring proper functioning of earth fault and overcurrent relays incluiding removing carbondeposite from contect point greasing and tightining all fixed andmoving contects for smooth functioning including replacement of tripping and closing coil, 30 Voits complete all as specified and as directed.(Note : - Calibratiion of relays and Primary and secondry injection test shall be conducted by Authorised Company / Manufactures. Certifacte of authority shall be produced by the technician. Auth Company:Make :- L&T / Siemens / ABB / Crompton)
16Locating and pin point electric Faultprecisely on high voltage (11KV) Under Ground CableFault, Locating System which is the most Advanced system in power cablefault detection combining the best-in market technologies in to a single fully automatic centralized setupwith high reliabiliyand Multi-levei safty standards complete all as specified and as directed.
17Taking down the failed cable from its position, supply, prepare and connect cable jointing kit for 11 KV (Earthed) grade cable, for outdoor end termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
18Taking down the failed cable from its position, supply, prepare and connect cable jointing kit for 11KV (Earthed) grade cable, for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
19Taking down the failed cable from its position, supply, prepare and connect cable jointing kit for 11KV (Earthed) grade cable for Indoor end termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
20Taking down the failed cable from the excavated trench, material and labour for straight through cable jointing kit for 11KV (Earthed) grade cable, Heatshrink type complete with accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm all as specified and as directed.
21Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / stay assembly / pipe lines and getting out in soft / loose soil complete all as specified and as directed.
22Excavation in trenches in hard / dense soil not exceeding 1.5 m in wide and exceeding 1.5 mtr in depth for laying of cables / stay assembly / pipe lines and getting out complete all as specified and as directed.
23Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed.
24Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
25Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed by Engineer-in-Charge.Note: Only punned thickness shall be measured for payment purpose.
26Supply and laying un-reinforced pre-cast concrete cable covers, Class HV, type 1, flat, of size 300 x 180 x 40 mm for cable protection complete all as specified and as directed.
27Supply and lay common burnt clay building bricks sub class "B" of designation 75 laid in trenches as protection to cables complete all as specified and as directed.
28M & L for Road cutting / hard standing for taking up or laying of LT UG cable upto a depth of 15 cm, after laying of cable, well ramming to the excavated soil and repair the exvcavated portion of road as existing or by providing suitable mixture of PCC all as specified and as directed.
29Supply and fixed in repairs Danger Notice board of 1.6 mm thickmild steel sheet vitreous enamelled white withletter, figures and conventional skull and bones in a single Red colour anf fixed with MS Clamp ,bolts and nuts of approved sizefor LT 20 cm X 15 cm Size complete all as specified and as directed.
30Description all as per Ser item No 30 abovebutfor HT- 25 cm X 20cm complete all as specified and as directed.
31Taking down unserviceable GI tubing and M&L for new galvanized steel tubing, light grade, with all fittings for protection of cable complete all as specified and as directed of the following sizes :-
32(a) 100 mm bore.
33(b) 80 mm bore
34(c) 50 mm bore
35(d) 40 mm bore
36M&L for repair of transformer by carefully dismantling the HT / LT and earth connections, draining out the oil from transformer to the required level and storing in cleaned containers, opening the top cover and conservator tank from transformer, for rectifying the defects and dismantling and replacing burnt out LT/ HT bushes and fixing back the same using new oil seal, gaskets, GI nuts, bolts & washers of suitable size, making all HT / LT connections as per the original, re-filling the transformer oil to the required level and testing on completion for capacity upto 400 KVA complete all as specified and as directed. NOTE :-(i) LT/ HT bush, transformer oil for topping up will be measured and paid separately as supply only under relevant items.
37Disconnecting the HT / LT connections, taking out the transformer from its plinth at any situation with the help of suitable crane and transporting the transformer to workshop for carrying out necessary repairs and bringing back and re-install in its original place, of capacity upto 400 KVA complete all as specified and as directed.
38Disconnecting the Electric cable connections, taking out the voltage stabilizer from its position at any situation with the help of suitable pully / crane and transporting thevoltage stabilizer to workshop for carrying out necessary repairs and bringing back and re-install in its original place, of capacity upto 75 kVA complete all as specified and as directed.
39Taking out complete core from transformers / Voltage stabilizer of capacity upto 400 KVA, cutting and removing burnt out winding and re-winding the same with super enamelled copper conductor of existing gauge using proper insulatingmaterials, applying varnish, drying in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and as directed.NOTE :-Shifting of transformers/ Voltage stablizer from installed position to Civil workshop and back will be measured and paid seperately under relevant items.
40Filtration of transformer oil at site of 11KV / 433V,indoor / outdoor transformer / Voltage stabilisers of any capacity installed at various locations, with mobile type filtration plant to acheive minimum di-electric strength of 40 KV for 1 minute at 4 mm gap, as per relevant I.S. and Topping up of transformer oil into the body / conservator tank of transformer upto required level, including testing and recording the values of di-electric strength of oil before and after filtration at site with transformer oil testing machine complete all as specified and as directed. NOTE : - Transformer oil will be measured and paid seperately as ""supply only"" items of schedule.
41Supply only transformer oil for topping up in transformerscomplete all as specified and as directed.
42Supply only HT bush of capacity upto 250 KVA.complete all as specified and as directed.
43Supply only HT bush of capacity above 250 KVA and upto 400 KVA. complete all as specified and as directed.
44Supply only LT bush of capacity upto 250 KVAcomplete all as specified and as directed.
45Supply only LT bush of capacity above 250 KVA and upto 400 KVA complete all as specified and as directed.
46Supply only HT bush with copper rod of capacity upto 250 KVA complete all as specified and as directed.
47Supply only HT bush with copper rod of capacity above 250 KVA and upto 400 KVA complete all as specified and as directed.
48Supply only LT bush with copper rod of capacity upto 250 KVA complete all as specified and as directed.
49Supply only LT bush with copper rod of capacity above 250 KVA and upto 400 KVA. complete all as specified and as directed.
50M&L for preparation of old painted surfaces of 11 KV / 433 V outdoor type distribution transformer, painting with spray gun through out externally with two coats of synthetic enamel paint of best quality of approved colour and writing machine number in white colour on black background complete all as specified and directed for the following capacities of transformers:-
51(a) Transformer of capacity upto 100 KVA.
52(b) Transformer of capacity above 100 KVA and upto 250 KVA.
53(c) Transformer of capacity above 250 KVA and upto 400 KVA.
54Disconnecting the HT / LT connections of a defective transformer of any capacity and shifting the trolley mounted mobile type transformer of capacity 200 KVA to the required location with tractor or crane if required and making all necessary HT and LT connections, testing and return back to the original location after completion of transformer repairs and reconnection the same complete all as directed.
55Taking down unserviceable breather and Supply & fix silica gel breather, suitable for transformer including sufficient quantity of silica gelcomplete all as specified and directed for thefollowing capacities of transformer :-
56(a) Transformer of capacity upto 100 KVA.
57(b) Transformer of capacity above 100 KVA and upto 250 KVA.
58(c) Transformer of capacity above 250 KVA and upto 400 KVA.
59M&L for trimming of tree branches around HT / LT overhead lines, upto 3m on both sides of over head lines and depositing where directed at a distance not less than 50 mtr complete all as specified and directed.NOTE :-The item will be measured in span length. The approx. span length is 30M to 40M.
60Stringing and Fixing Only in position of existing sagged ACSR conductor in OH lines of HT / LT/ street light conductors including binding with aluminium wire complete all as specified and as directed. Note :- The item will be measured in span length. The approx span length is 30 mtr to 40 mtr.
61M&L for Locating and pin point electric Faultprecisely on LT UG cable Under Ground Cable ( 1.1 KV ) Fault, Locating System which is the most Advanced system in power cablefault detection combining the best-in market technologies in to a single fully automatic centralized setupwith high reliabiliyand Multi-level safty standards
62(a) LT UG cable 2core x 10Sqmm to 4 core x 16 sqmm
63(b) LT UG cable 3.5core x 25Sqmm to 3.5 core x 50 sqmm
64(c) LT UG cable3.5 core x 70 sqmm to 3.5 core x 300 Sqmm
65Cutting and removing the damaged portion of the LT cable,supply, prepare and connect cable jointing kit for 1.1KV grade cable for cold shrink type straight through joint complete with jointing material and accessories suitable for XLPE, armoured aluminium conductor cable of size 4x16 Sqmm complete all as specified and as directed. Note : - Earth work will measured and paid seperately under relevant items.
66Description all as per Seritem No 52 here-in-before but for cable of size 3.5 /4 x 25 mm² to 3.5 x 70 mm². complete all as specified and as directed.
67Description all as per Ser item No.52 here-in-before but for cable of size 3.5 x 95 mm² to 3.5 x 240 mm². complete all as specified and as directed.
68Supply &Laying LT UG Cables , XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, of following cross-sectional area complete all as specified and as directed.
69(a)10 Sqmm, 2 Core
70(b)16 Sqmm, 4 Core
71(c)25 Sqmm, 4 Core
72(d)50 Sqmm, 3.5 Core
73(e)70 Sqmm, 3.5 Core
74(f)95 Sqmm, 3.5 Core
75(g) 120 Sqmm, 3.5 core
76Taking out unserviceble Earthing from Sub stns, M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m "or" upto test terminal point, drawn through 40mm dia light grade GI pipe for protection of galvanized iron strip in the ground, further connecting with suitable size of earth strip to LT Panel, Transformer, DBs etc., including excavation, earth work, magnesium sulphate-50 Kg and charcoal in alternate layers on all sides sorrounding the earth plate, bentonite-25 Kg clay mixed withwater and loomy soil sorrounding the plate on all sides, all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, including breaking and removing the old unserviceableearth materials complete all as specified and as directed. Note :- Excvation earth work and GI strip upto 7.5 mtr included in the job.
77Taking down change over switch and S&F new onload change over switch with sheet metal enclosure, TPN, 415 volts, 50 Hz, AC of the following sizes complete all as specified and as directed.Make: L&T / Siemens / Havells / CG.
78(a) 100 Amps
79(b) 200 Amps
80Taking down MCCBs of any description from the panel board and S&F new MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity from 25 to 100 Amps, breaking capacity 16 KA, complete all as specified and as directed.
81Taking down MCCBs of any description from the panel board and S&F new MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 125 Amps, breaking capacity 16 KA, complete all as specified and as directed.
82Taking down MCCBs of any description from the panel board and S&F new thermal adjustable MCCBs, 3 pole, 415 volts, as existing type and model, including modification to the panel as required, of capacity 160 Amps, breaking capacity 36 KA complete all as specified and as directed.
83Taking down MCCBs of any description from the panel board and S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
84Taking down MCCBs of any description from the panel board and S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 250 Amps, breaking capacity 36 KA complete all as specified and as directed.
85Taking down MCCBs of any description form the panel board and S&F new MCCBs, 3 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 320 Amps, breaking capacity 36 KA complete all as specified and as directed.
86Taking down MCCBs of any description form the panel board and S&F new MCCBs, 4 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 400 Amps, breaking capacity 36 KA complete all as specified and as directed.
87Taking down MCCBs of any description form the panel board and S&F new MCCBs, 4 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 630 Amps, breaking capacity 50 KA complete all as specified and as directed.
88Supply, mix and pouring the Magnesium sulphate either through the existing watering pipe or by making holes sorrounding the earth pit, at the rate of 5Kgs per pit, for charging the earth pit, for improving the ER values including measuring and recording the values.
89M&L for PCC 1:3:6, type C-2 mixusing 40 mm graded stone aggregate as in filling and mass concrete foundationto pole etc., including breaking and removing the old concrete and necessary form work complete all as specified and as directed.
90M&L for PCC 1:2:4, type B-1 mix using 20 mm graded stone aggregate as in coping to poles etcincluding breaking and removing the old concrete and necessary form work complete all as specified and as directed.
91M&L for Cutting , clearing vegetation and bushes in and around theSub Station areas complete all as specified and as directed.
92M&L for GI earth Strip 32 mm x 6 mm layed in ground / fixed on walls including taking outunserviceable earth strip complete all as specified and as directed.