Water Resources and Irrigation Government Departments Closing in 0 days TDR #39204284

Tender For Installation Of Gellepara Solar Powered Mdtw (3 Points) Irrigation Scheme Under Ridf-Xxviii (Nabard) For The Year 2022-23

Issued by Government Departments · sorbhog, Assam
Tender Value
89.11 Lakhs
Estimated cost
Bid Submission
31 Aug 2023
0 days left
EMD
1.78 Lakhs
Bank guarantee accepted
Document Fee
1800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sorbhog → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Installation Of Gellepara Solar Powered Mdtw (3 Points) Irrigation Scheme Under Ridf-Xxviii (Nabard) For The Year 2022-23 As Per Boq

BOQ

Name of Work: Installation of Gellepara Solar Powered MDTW (3 Points) Irrigation Scheme under RIDF-XXVIII (NABARD) for the year 2022-23
Sl. No. Item Description
1Estimate for Installation of Tube Well, Installation and Commissioning of Solar PV Module
2Movement of drilling Rig, Tools & Plants, accessories including drill pipes, casing pipes etc. to drilling site and back.
3Boring of DTW ofBore Hole up to 450 mm dia and up to a depth of 70.00 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required Tools & Plants, materials & Labour to site to perform the job in complete as directed in alluvium areas (means areas where the strata comprises of loose, unconsolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS: 2800 (part-I)of 1991. ( Soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of Rig by making temporary approach road etc. to the field up to distance of 1000 M.)
4Supply, lowering & installation in tube well 200 mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of reputed brand like Supreme / Oriplast / Jindal / Prince etc. and as directed.
5Supply, lowering & installation in tube well 200 mm PVC Ribbed Screen Filter pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of repute brand like Supreme / Oriplast / Jindal / Prince etc. and as directed.
6Shrouding of the Deep Tube Well assembly bypacking of river Pea Gravel of size 4mm to 8 mm free from sand, dust and any other foreign materials after screening/stacking at site including supply, transportation, labour etc. complete as directed. (As per Annexure - I)
7Developing the Tube well assembly by Air Compressor of capacity 8-12 kg/cm2 andCMF = 450 M3 / Min. so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litholog/ draw down data etc. as per IS : 11185 of 1999.(For new DTW minimum 72 hours development is compulsory. Additional pea gravel required ,if any during development would be extra).The following data should be reflected in the report of development.1. Static water level 2. Available average discharge3. Drawdown at different discharge
8Supply & Installation of Solar Pumping System :(a) Solar Submersible Standalone Pump set with 7.5 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 200 mm bore well and discharge capacity approx 1400 LPMat10 M head (Dynamic Head Range 10-20 Mtr and Shut off head 30 M) working at 8000 Wattpof solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 20(twenty) mtr. column pipe, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS.(b) Supply, fitting-fixing and testing & commissioningof Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 8000 Wp (approx.) considering 7.15 kWh/ M2 / Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15%and hot dipped galvanized (minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 – 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp > 587 V &System Voc < 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed.(Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make like TATA/Bikram/ Waaree etc. and carry at least 20 years warrenty & comprehensive maintenance for 1 year and should installed preferably above HFL)(c) Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.(d) Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3\" X 1.5\" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the /Roof with GI Saddles 1100 mm apart.NB :-1.Solar Pump set should be of reputed make andcarry 5 years warranty/ guarantee2.Flow Range : 90 L per Wp of PV array from TDH of 10 M3.Controller DC Input Voltage: (i) System Vmp > 587 V & (ii) System Voc < 800 V4.Controller Conforming to : IEC 61683–1999 & IEC 60068-1-2,IEC 60068–2-(2,14,30,78)This benchmark cost are for the systems installed as per MNRE specifications inclusive of the totalcost of system and its installation, commissioning, transportation, insurance, warranty/guarantee, monitoring & maintenance for five years.Cost Solar Standalone Pumping System = Rs 4,08,631.00Add GST @ 18 % = Rs 73,553.58Cost Solar Pumping System = Rs 4,82,184.58
9Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed.Size : 100mm
10Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout asdirected / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directedSize : 100mm
11Supply , fitting-fixing of delivery pipes 100 mm dia GI/ fabricated GI pipes(HD of repute brand with ISI marked) with flange at both end/whereever required with pipe jointing sets,including painting in complete as per drawing/ specification including temporary pipe support as required and as directed.
12Supply, fitting-fixing of delivery pipes of 150 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.
13Supply, fitting-fixing of surge tank of size 900m dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 200mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer fllowed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed.
14Estimate forConstruction of Underground PVC Pipe Distribution System
15Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
16Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).A) 160mm dia Main line
17Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).B) 110mm dia Branch line
18Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.
19Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.
20Supplying, fitting, fixing, joiningof PVC end cap fitting with solvent cement as per specification includinglocal carriage, testing leakage etc.complete as directed.
21Estimate for Construction of Spout Chamber ( 21 Nos.)
22Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
23C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
241st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
2512 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4
26Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line includinglocal carriage, testing leakage etc.complete as directed.
27Supplying, fitting, fixing PVC bend pipe sizejoining with pipes with solvent cement,testing leakages etc. complete as directed.
28Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
29Construction of Boundary Wall
30Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
31Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
32C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
33R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
34Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).(A) Shuttering (Column)
35Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).(B) Shuttering (Beams) with out props
361st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete.
37Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
38Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line includinglocal carriage, testing leakage etc.complete as directed.
39Supplying, fitting, fixing PVC bend pipe sizejoining with pipes with solvent cement,testing leakages etc. complete as directed.
40Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
41Detail estimate for construction of Sign Board
42Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.

AI Tender Summary

OUR REF NO 39204284
AUTHORITY Government Departments
TENDER VALUE 89.11 Lakhs
LAST DATE 31-08-2023
Authority
Authority Name Irrigation Department
Work Description Installation Of Gellepara Solar Powered Mdtw (3 Points) Irrigation Scheme Under Ridf-Xxviii (Nabard) For The Year 2022-23 As Per Boq
Basic Detail
Tender No BCI/TECH/NIT/31/38
Bidding Type Tender
Location
City sorbhog
State Assam
Key Dates
Publish Date 18 Aug 2023
Submission Date 31 Aug 2023
Open Date 01 Sep 2023
Finance
Tender Value 89.11 Lakhs
Tender Fee 1800
EMD 1.78 Lakhs
Exemption Not Available
Document List
a78781e4-1295-47d1-9876-298d46a15503.html
Biddocument.pdf
BOQ_51588.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 01, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a78781e4-1295-47d1-9876-298d46a15503.html

pdf

Biddocument.pdf

xls

BOQ_51588.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders