Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. St Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Majaltaunder Jjm On Turnkey
Tender Overview
Project Description
Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. St Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Majaltaunder Jjm On Turnkey Basis.
BOQ
| Sl. No. | Item Description |
| 1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Majalta . |
| 2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 3 | GI V Cross -arm with top Bracket including clamps |
| 4 | GI Channel X-arm including clamps and Angle for braces |
| 5 | 30mm² ACSR weasel conductor |
| 6 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 7 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
| 8 | Galvanized Nuts and Bolts |
| 9 | Danger Plates with Clamps |
| 10 | Anti climbing device with clamps |
| 11 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 12 | Painting of 9 mtr ST poles with two coat of Aluminium Paint. |
| 13 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 15 | Survey,Supply, Transportation, Carriage, Erection,Testing and Commissioning for installation of 250 KVAat WSS Majlata |
| 16 | 11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 CopperWound, & with LV Cable box having detachable Aluminium Gland plate |
| 17 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
| 18 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
| 19 | 11 KV Horn gap fuse set 3 phase 200 A |
| 20 | 300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
| 21 | 9 mtr. Long ST pole (ST-410 SP33) |
| 22 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 23 | GI Channel /Angle/flat of sizes including clamps |
| 24 | Galvanized Nuts and Bolts. |
| 25 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 26 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
| 27 | LT distribution box for 250 KVA DTR with MCCB for incomer and SFU\"s for outgoing circuits |
| 28 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 29 | PG Clamps |
| 30 | Danger Plates with Clamps |
| 31 | GI Barbed wire for Anticlimbing |
| 32 | 3-phase HT Trivector meter with CT PT Unit |
| 33 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 34 | Painting of ST poles 9 mtr. long with 2 coat of Al. paint |
| 35 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Majalta . |
| 36 | 8 mtr. Long ST poles (ST-410 SP15) |
| 37 | GI M Clamps for shackle insulator |
| 38 | 50mm²ACSR Rabbit Conductor |
| 39 | Shackle insulator |
| 40 | Galvanized Nuts and Bolts. |
| 41 | Danger Plates with Clamps |
| 42 | Anti climbing device with clamps |
| 43 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
| 44 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
| 45 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 46 | Al. jointing sleeves |
| 47 | LT Line Spacers |
| 48 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender