}

Tender For Supply Of Spares And Consumables For Annual And Running Maintenance In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra, Lucknow-Uttar Pradesh

Uttar Pradesh Jal Vidyut Nigam Limited has published Tender For Supply Of Spares And Consumables For Annual And Running Maintenance In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra. Submission Date for this Tender is 13-09-2023. Fuses Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39197832
Tender For Supply Of Spares And Consumables For Annual And Running Maintenance In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra
Open Tender
NCB
Uttar Pradesh
Lucknow
13-09-2023

Tender Details

Supply Of Spares And Consumables For Annual And Running Maintenance In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra , Part-Asupply Of Electrical & Mechanical Spares Required For Annual Maintenance And Annual Consumable , Power Contactor, Ac3 Current Rating 16 Amps, Operating Coil 415 Volt Ac, With 1 No Auxiliary Contact, Make: Siemens / Abb / Havells / C&S / L&T , Microprocessor Controlled Overload Relay With Current Rating-3-12 Amps Make: Siemens / Abb / Havells / C&S / L&T , Aluminium Tubular Xlpe Lug Long Barrel 35 Mm2 , Aluminium Tubular Xlpe Lug Long Barrel 120 Mm2 , Aluminium Tubular Xlpe Lug Long Barrel 185 Mm2 , Aluminium Tubular Xlpe Lug Long Barrel 400Mm2 , Hrc Cylindrical 63 Amps ( Type Hf ) , Hrc Fuse ( Bs ) 3Nw, Blade Tag , 2 Amps , Hrc Fuse ( Bs ) 3Nw, Blade Tag , 4Amps , Hrc Fuse ( Bs ) 3Nw, Blade Tag , 6 Amps , Hrc Fuse ( Bs ) 3Nw, Blade Tag , 20 Amps , Hrc Fuse ( Bs ) 3Nw, Blade Tag , 25 Amps , Digital Dc Voltage Meter For Field Voltage ( For Control Desk ) Size 96X96 Mm, Input? 0-500 Volt Dc , Range0-500 Volt Dc, Accuracy? ±0.2%, Auxiliary Supply 240 Volt Ac / 50 Hz , Digital Dc Ampere Meter For Field Current ( For Control Desk ) Size 96X96 Mm, Input? 0-60 Mv Dc , Range0-2000 Amp Dc, Auxiliary Supply? 240 Volt Ac / 50 Hz , 160 Amps ( Din Type Fuse Links Type Hn Size-00 ) , 200 Amps ( Din Type Fuse Links Type Hn Size-0 ) , Hooter 48 Volt , 1 Phage 240 / 415 V Ac Mcb, Rated Current -25 Amp, Make-Siemens / Abb / L&T / C&S , 1 Phage 240 / 415 V Ac Mcb, Rated Current -32 Amp Make-Siemens / Abb / L&T / C&S , 3 Phage 415V Ac Mcb, Rated Current 25 Amp Make-Siemens / Abb / L&T / C&S , 3 Phage 415V Ac Mcb, Rated Current 32 Ampmake-Siemens / Abb / L&T / C&S , Rotary Cam Switch 25A / 250 V Ac, 2No+2Nc, Kaycee Switch , Ac Voltmeterrange -1000V ( 72X72 Mm Size ) , 11 Kv Ac Epoxy Resin Cast Insulator , Asbestos Cloth , Thickness 5Mm , Soft Pvc Hose With Embedded Steel Wire Reinforced, Id 19 Mm, Od 25 Mm , Permanite Packing , Thickness-3 Mm , Permanite Packing , Thickness-2 Mm , Part B – Supply Of Cleaned And Pressed Old Cotton Dhoti&White Teased Cotton Waste For Rihand Power Station Pipri, Sonebhadra , Cleaned And Pressed Old Cotton Dhoti Details As Given Below: A ) All Dhoti Shall Not Be Less Than 2Mtr.& 1Mtr. In Width. B ) All Dhoti Shall Be Of Cotton. C ) All Dhoti Shall Be Dry, Fully Cleaned & Pressed. , White Teased Cotton Waste As Per Sample & Should Be Fully Cleaned , Part C – Wide Band Led Pilot Light ( Complete Unit ) ( Conforming To Latest Editions Of Relevant Is / Iec ) , Wide Band Led Pilot Light Red , Wide Band Led Pilot Light Yellow , Wide Band Led Pilot Light Amber , Wide Band Led Pilot Light Blue , Wide Band Led Pilot Light Green , Wide Band Led Pilot Light White , Part D – Supply Of Spares Required For Static Excitation Equipment In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra , Dc Voltage Transducer, Input 0-60 Mv, Dual Output 4-20 Ma Galvanically Isolated, Aux Supply 220 Volt Ac , Dc Voltage Transducer, Input 0-500 Volt, Dual Output 4-20 Ma Galvanically Isolated, Aux Supply 220 Volt Ac , Dc Voltage Transducer, Range ( - ) 15 0- ( + ) 15Volt, Dual Output 4-20 Ma Galvanically Isolated, Aux Supply 220 Volt Ac , Power Contactor, Ac3 Current Rating 9 Amps, Operating Coil 240 Volt Ac, With 1 No Auxiliary Contact, Make: Siemens / Abb / / L&T / C&S , Ac Voltage Transducer, Input 0-110 Volt ( Max 137.5 Volt ) , Single Output 4-20 Ma Calibrated To Give Output 16Ma For 110 Volt Ac Input, Aux Supply 220 Volt Ac , Ac Current Transducer, Range 0-4000 Amp, Input 0-1 Amp Ac, Single Output 4-20 Ma, Accuracy 0.5%, , Aux Supply 220 Volt Ac , Reactive Power Transducer, 3 Phase 3Wire Unbalance Ct Ratio 4000 / 1, Pt Ratio 11Kv / Å3 / 110Volt / Å3, 61.50Mvar Lead-0- ( - ) 61.50Mvar Lag, Single Output 4-12-20 Ma, Input Voltage 110 Volt Ac, Current 0-1 Amp Ac, Accuracy 0.5%, Calibrated To Give Output 20Ma For 110 Volt Ac Input, Aux Supply 220 Volt Ac , Power Factor Transducer, Single Output 4-20 Ma, Range ( - ) 0.5-1- ( + ) 0.5, Ct Ratio 4000 / 1, Pt Ratio 11Kv / Å3 / 110Volt / Å3, Aux Supply 220 Volt Ac, Accuracy 1.0 %

Key Value

Document Fees
INR 826 /-
EMD
INR 23500.0 /-
Tender Value
INR 11.57 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail