Tender For Special Repair To E.I In Badminton Court Building, Swimming Pool Building, Gym Building, Hostel Building And S/R To E.I Of Different Size Underground Cable Laying For Different Buildings Of Sports Complex Kumetha At Deoghar., dhanbad-Jharkhand

Electric Works Division has published Tender For Special Repair To E.I In Badminton Court Building, Swimming Pool Building, Gym Building, Hostel Building And S/R To E.I Of Different Size Underground Cable Laying For Different Buildings Of Sports Complex Kumetha At Deoghar.. Submission Date for this Tender is 23-08-2023. Cable Laying Tenders in dhanbad Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

39179927
Tender For Special Repair To E.I In Badminton Court Building, Swimming Pool Building, Gym Building, Hostel Building And S/R To E.I Of Different Size Underground Cable Laying For Different Buildings Of Sports Complex Kumetha At Deoghar.
Open Tender
Indian
Jharkhand
dhanbad
23-08-2023

Tender Details

Tender For Special Repair To E.I In Badminton Court Building, Swimming Pool Building, Gym Building, Hostel Building And S / R To E.I Of Different Size Underground Cable Laying For Different Buildings Of Sports Complex Kumetha At Deoghar.

Key Value

Document Fees
INR 10000 /-
EMD
INR 244500.0 /-
Tender Value
INR 1.22 Crore /-

BOQ Items

Name of Work: S/R to E.I in Badminton Court Building, Swimming Pool Building, Gym Building & Hostel Building and S/R to E.I of different size underground cable laying for different buildings of Sports Complex Kumetha at Deoghar.
Sl. No. Item Description
1Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mm FR PVC Insulated Copper Conductor single core cable in face/recessed PVC conduit, with modulartype switch, modular plate, suitable size PVC/ G.I. box etc. as required. a) Group C
2Wiring for circuit/ sub main wiring along with earth wire with the following sizes PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. a). 2x2.5 sq. mm.+1x2.5 sq. mm. earth wire ( circuit )
3b) 2x6.0 sq mm + 1x6.0 sq mm earth wire ( 19nos Submain)
4c). 2x4 sq. mm.+1x4 sq. mm. earth wire (32 nos Submain)
5d). 2x4 sq. mm.+1x4 sq. mm. earth wire ( 140 nos power wiring + 4 nos AC wiring)
6e). 2x1.5 sq. mm.+1x1.5 sq. mm. earth wire ( highbay light wiring and internal flood light & heavy duty wall fan wiring )
7Wiring in existing conduit a)5x4 sq. mm. ( TPN DB for P&AC submain wiring)
8S/F PVC conduit 25mm dia
9S/F 3 core 2.5 sq.mm summersible waterproof copper cable for wiring of swimming pool light under water (total 28 nos light)
10Supplying and drawing following size of FR PVC insulated copper conductor single core cable in the existing surface / recessed Steel/ PVC conduit as required a)1x 1.5 sq. mm( for inverter wiring)
11Supplying and fixing suitable size G.I. box with modular plate cover in front on surface or in recess including providing fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modulartype switch connection etc. as reqd.
12Supplying and fixing suitable size G.I. box with modular plate cover in front on surface or in recess including providing fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps. modulartype switch connection painting etc as reqd.
13S/F following way single pole neutral, sheet MCB distribution board, 240 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, Phosphatized and powder painted including earthing etc as reqd. (But without MCB/RCCB/ Isolator)a) 8 way double door .
14b) 6 way double door
15c) 4 way double door
16d) 2 way single door
17S/F following way three pole neutral, sheet MCB distribution board, 415 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, Phosphatized and powder painted including earthing etc as reqd. (But without MCB/RCCB/ Isolator) a) 6 way (4+18) , doubledoor horizontal type
18S/F following 240 volts, ‘C’ series/"B" series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCBDB complete with connection, testing and commissioning etc. as reqd. a) 6/32 amp MCB
19b) 63 amp DP MCB
20c) 40 amp DP MCB
21d) 63 amp TPN MCB
22S/F double pole single phase 40 amp RCCB for swimming pool light DB
23S/F 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 Amps’C’ series ,SP MCCB, in sheet steel enclosure , on surface or in recess with chained metal cover for the socket outletand complete with connections, testing and commissioning etc as reqd.
24S/F LED tube light fitting 20/22 watt including connection etc as reqd. (Phillips/Bajaj/or equi)
25Supplying and fixing batten/ angle holder including connection etc as reqd.
26S/F 2 pin 5 Amp ceiling rose on the existing junction box/woden block including connection etc as reqd.
27S/F 9/10 watt L.E.D lamp etc as reqd. (Bajaj/ Phillips/ or equi)
28S/F 18 watt surfacelight
29S/F steped type electronic fan regulator deluxe on the existing switch box/ cover including connection etc as reqd.(a) Electronic step fan regulator modular type
30S/F PVC/ G.I box of follwing sizes on surface or in recess with sutiable sizes of Phenolic laminated sheet cover infront including painting etc as reqd. (a) 75 mmx75 mmx50mm deep/ (4”x4”)
31S/F 9" exhaust fan complete including connection etc as reqd. (Make- Usha/Havells/Poller)
32S/F 12" exhaust fan complete including connection etc as reqd. (Make- Usha/Havells/Poller)
33S/F 100 w highbay Light ,Make- havells/bajaj/halonix / jaquar
34S/F 100W LED Flood light
35S/F 150W LED Flood light
36S/F 200W LED Flood light
37S/F 90 w L.E.D Street light ,Make- havells/bajaj/halonix / jaquar
38S/F 120 w L.E.D Street light ,Make- havells/bajaj/halonix / jaquar
39S/F 100 w flood light ,Make- havells/bajaj/halonix / jaquar
40S/F 65mm dia , G.I bend medium class ( for LED street light and LED Flood light strengthening )
41S/F of 48" ceiling fan with all (Make Bajaj/Halonix/Vguard/ polar)
42S/F 16" (400mm)Wall mounted fan" Make:- Bajaj, Polar, Halonix, Polycab or Equivelant.
43S/F450mm sweep matel bodyWall mounted fan" Make:- Bajaj, Havells, Halonix, Polycab or Equivelant.
44Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuses, unit in existing metal board with rewireable type fuseincluding drilling holes in metal board making connections etc as required a). 32 amp, double pole ( for street light on Buildings)
45Earthing with copper earth plate 600mm x 600mm x 3mm thik including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc as required . ( with charcoal or cocke and salt )
46Supplying and laying 8 swgcopper wire at 0.50 meter below ground level for conductor earth electrode, including soldering etc as reqd.
47Supplyingof XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes ( Make , Havells , polycab , finolax ,capital or equivelant ) a) 3.5 core 400 sq.mm
48b) 3.5 core 300 sq mm
49c) 3.5 core 185 sq mm
50d) 3.5x 70 sq mm
51e) 3.5x 25 sq mm
52f) 4x 10 sq mm
53g) 4x 16 sq mm
54h) 2x 16 sq mm
55i) 2x 10 sq mm
56j) 2x 6 sq mm
57S/F sintex box with MCB 6ASP MCB
58Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
59Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mmdirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
60Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
61Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
62Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. (TransformerPanel near Transformer) a) 630 amps, 35 kA Adjustable thermal setting MCCB -1nos b) voltmeter - 1 nos c)Ameter - 1 nos d) Indicator - 3nos e) CT Coil - 3 nosf) 50mm x5mm copper tape ( for Busbar) - 16kg
63Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. (Main Panel Placed at Art & culture Building) a)630 amps, 4 pole Air Circuit Breaker ( Main incomer) - 1nos b) 500 amps, 35 kA, adjustable thermal setting MCCB (for outdoor feeder panel 4) -1 c) 315 amps, 35 kA, adjustable thermal setting MCCB (for Art & culture building) -1 d)200 amps, 35 kA, adjustable thermal setting MCCB (for stadium light panel) -1 e) 160 amps, 35 kA, adjustable thermal setting MCCB (for Hostel Building) -1 f)100 amps, 10 kA, adjustable thermal setting MCCB (for outdoor feeder panel no 1, 2 & 3) - 4 g) 63 amp DP MCB -5 nos h) Voltmeter - 1 nos(digital)i) Ammeter - 1nos (digital) j) Indicator - 3nos k) C.T coil - 3nos l) 50mm x5mm copper tape - 49 kg
64Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. (OUTDOOR FEEDER PANEL NO - 04) a) 500 amps, 35 kA, adjustable thermal setting MCCB (Main incomer)- 1nos b) 315 amps, 35 kA, adjustable thermal setting MCCB (for Badminton & swimming pool Building) - 2 nos C) 160 amps, 35 kA, fixed thermal setting MCCB (Gym Building) -1 d) 63 amp DP MCB - 2 e) Voltmeter - 1 nos(digital)f) Ammeter - 1nos (digital) g) Indicator - 3nos h) C.T coil - 3nos i) 50mm x5mm copper tape - 25 kg
65Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. (Badminton & swimming pool Building Main Panel) a) 315 amps, 35 kA, adjustable thermal setting MCCB (Main & Gen incomer) - 2nos b)250 amps, 4 pole changeover -1 c) 100 amps, 10 kA, fixed thermal setting MCCB -8 nos d) 63 amp TPN MCB -2 e) 63 amp DP MCB -8 g) Voltmeter - 1 nos(digital) h) Ammeter - 1nos (digital) i) Indicator - 3nos j) C.T coil - 3nos k) 50mm x5mm copper tape - 45 kg
66Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. sub Panel (for highbay light, flood light & heavy duty wall fan) of Badminton & swimming pool Building.( Placed at 1st floor) a) 100 amps, 10 kA, fixed thermal setting MCCB - 1nos b) 6 to32 amp DP MCB - 19 c) Voltmeter - 1 nos(digital)d) Ammeter - 1nos (digital) e) Indicator - 3nos f) C.T coil - 3nos g)4 sq.mm cu wire for connection - 57 mtr h) 50mm x5mm copper tape - 10 kg
67Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. Ground Floor sub Panel of Badminton & swimming pool Building and 1st floor sub panel of Gym Building a) 100 amps, 10 kA, fixed thermal setting MCCB) - 1nos b) Voltmeter - 1 nos(digital)c) Ammeter - 1nos (digital) d) Indicator - 3nos e) C.T coil - 3nos f) 50mm x5mm copper tape - 7 kg
68Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. Main Panel of Gym Building & Hostel Building at Ground floor a) 160 amps, 35 kA, fixed thermal setting MCCB (Main & Gen incomer) - 2nos b) 125 amps,4 pole changeover - 1 nos c) 25/100 amps, 10 kA, fixed thermal setting MCCB -2 d) 63 amp DP MCB -5 e) Voltmeter - 1 nos(digital)f) Ammeter - 1nos (digital) g) Indicator - 3nos h) C.T coil - 3nos i)4 sq.mm cu wire for connection - 12mtr f) 50mm x5mm copper tape - 10 kg
69Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. Sub Panel of Pavilion. ( football ground) a) 25/100 amps, 10 kA, fixed thermal setting MCCB - 1nos b) 6 to32 amp DP MCB - 9 c) Voltmeter - 1 nos(digital)d) Ammeter - 1nos (digital) e) Indicator - 3nos f) C.T coil - 3nos g)4 sq.mm cu wire for connection - 27 mtr h) 50mm x5mm copper tape - 10 kg
70Add GST@18%
71Add Labour cess @ 1%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail