| 1 | SUB HEAD- EARTH WORK FOR FOOTBALL FIELDEarth work in excavation by mechanical means (Hydaulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, for all lift and lead, including getting out the excavated soil and disposal of surplus excavated soils as directed, within all lead and lift.All kinds of soil. |
| 2 | SUB HEAD- BASE WORK FOR FOOTBALL FIELDConsolidation of subgrade with power road roller of 8 to 12 tonne capacity to required slopeincludingmaking goodtheundulations etc. with earth or quarry spoils etc.and rerolling the subgrade. |
| 3 | Supplying,layingand compactingofstone aggregate40mmnominalsizetoformacontour and elevation to the desired level. |
| 4 | Supplying,layingand compactingofstone aggregate20mmnominalsizetoformacontour and elevation to the desired level. |
| 5 | Supplying,layingand compacting ofstone aggregate10mmnominalsizetoformacontour and elevation to the desired level. |
| 6 | Supplying, stone dust to fill the voids |
| 7 | SUB HEAD- CONCRETE WORKProviding and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 8 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 9 | Sub Head DrainageProviding and laying non-pressure NP2 class (light duty) R.C.C. S & S jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia. R.C.C. pipe |
| 10 | Constructingbrickmasonrychamber90x90x100cminside,brickworkincm 1:4(1cement:4coarsesand)forsluicevalve,electricalcableetcwithRCCtop slab 1:2:4 mix(1cement:2coarse sand:4 graded stone aggregate 20mm nominal size)i/c necessory excavation,foundation concrete 1:5:10((1cement:2coarse sand:4 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3(1cement:3coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 11 | RCC Drain Coverproviding and fixing of 60mm thick,perforated,Pre cast RCC drain cover of size 600 x 600 x 60 mm with 1\"\" dia (8 to 12 nos round hole ) with 8mm rods @ 100mmc/c over the walls of drain at proper level for ease flow of water and both side of precast will be filled by cc 1:1.5:3 incl. side shuttering etc. complete inall respect as per direction of engineer in charge.make KK or equivalent as approved by engineer in charge. |
| 12 | SUB HEAD- BRICK WORK Brick work with F.P.S. bricks of class designation 75 infoundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | SUB HEAD- FINISHING12 mm cement plaster of mix :1:4 (1 cement : 4 coarse sand) |
| 14 | SUB HEAD SYNTHETIC FOOTBALL TURF SupplyingandlayingofUVresistantsynthetic artificialturf should be tested by FIFA asper latest guidelines quality rating including the followings,completeaspertheenclosed specifications and as below : (a) Complete artificial turf of the diamentions and specifications enclosed,of50mmpileheight,inNITasper FIFA quality rating on the existing base prepared for the purpose. (b) Turf panels gluedtogether with infill of washed silica sand and rubber granules of recommendedquantities. (c) Line markingsas per FIFAguidelinesforfutsalplayfieldincluding D-area. |
| 15 | Football post with net (FUTSAL standards) |
| 16 | SUB HEAD : FENCING Supply, fabrication & Installationwith Garware Netting all around-20 Feet Pole distance 10 feet Each from both sides(Vertical Poles-50*50/Horizontal Poles-35*35 including painting of poles. |
| 17 | Supply & Installation of TopGarware Net / Shade Net 50 mm with Fabrication Poles Support for Cross Support. |