Sabarimala Devaswom - Mandalam And Makaravilakku Festivals In 1199 Me – Replacement Of The Existing Electrical Installations In The Kailas Building Pc-3 At Sabarimala, Sannidhanam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2023
0 days left
EMD
29900
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sabarimala → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Sabarimala Devaswom - Mandalam And Makaravilakku Festivals In 1199 Me – Replacement Of The Existing Electrical Installations In The Kailas Building Pc-3 At Sabarimala, Sannidhanam
BOQ
| Sl. No. | Item Description |
| 1 | Dismantlingthe existingPVC conduits, switchboard, Distribution boards, cables and all other accessoriesas required for the proper completion of the work and fixing the switch boards, distribution boards(single phase & three phase) in recess by cutting holes suitable sizes on wall andmaking good the damages etc. (concealing thecables and PVC conduitnear the switch board and DBs) Electrician |
| 2 | Wireman Assistant |
| 3 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 4 | 2 way 5/6 amps switch |
| 5 | 15/16 amp switch |
| 6 | 3 pin 5/6 amp socket outlet |
| 7 | 6 pin 15/16 amp socket outlet |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 10 | 3 Module (100mmX75mm) |
| 11 | 4 Module (125mmX75mm) |
| 12 | 6 Module (200mmX75mm) |
| 13 | 8 Module (125mmX125mm) |
| 14 | 12 Module (200mmX150mm) |
| 15 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 17 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required).4 way (4 + 12), Double door |
| 18 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 19 | Triple pole |
| 20 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 21 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 22 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 23 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 24 | Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 25 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C |
| 26 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 27 | 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 28 | Supplying and fixing of Bulkhead fitting containing of 8 W LED lamp on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 30 | Repairs and maintenance of Existing MSBAfter removing all electrical connections and fittings from the Panel board, complete the panel with new/existing electrical installations. Electrician |
| 31 | Wireman Assistant |
| 32 | Fitter Grade 1 |
| 33 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 34 | Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurements will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated(excluding base frame) |
| 35 | Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 36 | Supply and providing heavy duty \"A\" section neoprene gasket in the panel board U\" section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 37 | Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 38 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp TP & N |
| 39 | 100 Amp, TP & N |
| 40 | Supply & Fixing of Three Phase Ammeter in Existing Panel Board |
| 41 | Supplying and fixing of Three Phase Voltmeters in existing Panel Board |
| 42 | Supplying & Fixing of Indication Lamp in Existing Panel Board |
| 43 | Fabrication supply and installation of Dust and vermin proof, wall/floor mounting metering cubical of cubical construction made from 2.0mm CRCA sheet, Providing necessary support made from the same gauge CRCA sheet to fix KSEB meter, TPN switch, Fuse units, Earth link and CT Chamber etc in hinged door construction for the font side with compartments if necessary, providing vision panel for the meter compartments, knock out for cable entry exist, painting the entire board with two coat of synthetic enamel paint over a coat of zinc chromate primer etc as required including fixing it on wall making good the damages colour washing etc. as required. CRCA sheet along be used for the fabrication. Angles/flats slotted angles etc shall not be used for the fabrication of main housing of meter board(including 3nos 250, HRC Fuse Base with HRC Fuse link ,100 A, 2 Way neutral links mounted on DMC/SMC base and also base fixing anchor bolts) 3 Phase meter Board |
| 44 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N |
AI Tender Summary
Tender Timeline
Aug 16, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 22, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender