| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (D.S.R 22 E&M Code No1.8.3) Group C |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm (D.S.R 2022 E&M Code No - 1.17.11) |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm (D.S.R 2022 E&M Code No - 1.17.21) |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (D.S.R 2022 Code No -1.32) |
| 5 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 06-way, Double door (D.S.R 2022 E&M Code No -2.3.1) |
| 6 | Supply of heavy-duty exhaust fan having size 450 mm, 900 R.P.M. in grey colour of single phase 230 volts. SOR (E&M)2022 item code 20.2.3 Make: - Almonard /Havells/ Bajaj. |
| 7 | Supply of Air circulator size 600 mm (24 inch), 1440 R.P.M. in grey colour of single phase 230 volts. SOR (E&M)2022 item code 20.3.2 Make:- Havells/ Bajaj. |
| 8 | Supply of ceiling fan of 1200mm sweep area of brown colour. SOR (E&M) 2022 item code 20.1.2 Make: - Orient/ Havells/ Any DJB approved make. |
| 9 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, \"C\" curve, single pole miniature circuit breaker. Make L&T/Siemens/ Havells |
| 10 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, \"C\" curve, Double pole miniature circuit breaker. Make L&T/Siemens/ Havells |
| 11 | Supplying and fixing 63 A rating, 240/415 V, 10 kA, \"C\" curve, Triple pole miniature circuit breaker. Make L&T/Siemens/ Havells |
| 12 | Supply of LT Power aluminum cable, solid conductor, XLPE insulated, PVC sheathed, armoured, 650/1100 V grade as per IS 7098 (Part 1) 1988 size 3 core 16 mm2 for external, internal lightening system etc. 100 mtr Coil Make: - Grandley/ Gloster/ Havells/ finolex. |
| 13 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (For laying 3 core 16 mm2 cable) (clamped with 1mm thick saddle) (D.S.R 2022 E&M Code No -7.7.1) |
| 14 | Installation of exhaust fan in the existing opening, including making goods the damage, connection, testing, commissioning etc. as required. DSR 2022 E&M, Code No.1.50.1 |
| 15 | Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC Insulated, copper conductor, single core cable and earthing etc. as required. DSR 2022 item code 1.41 |