Delhi University has published Tender For Repair Of Damaged Drinking Water Supply Line, Pvc Water Storage Tank And Allied Works At Various Flat B, C And D Block Reids Line Colony, University Of Delhi.. Submission Date for this Tender is 28-08-2023. Tanks and Cylinders Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
2 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
3 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter |
4 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend |
5 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
6 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
7 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
8 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall |
10 | 20 mm nominal dia Pipes |
11 | 25 mm nominal dia Pipes |
12 | 32 mm nominal dia Pipes |
13 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall .1 |
14 | 15 mm dia nominal bore |
15 | 20 mm dia nominal bore |
16 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore |
17 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
18 | 25 to 40 mm nominal bore |
19 | 50 to 80 mm nominal bore |
20 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length15 mm nominal bore |
21 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter |
22 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
23 | 15 mm diameter pipe |
24 | 20 mm diameter pipe |
25 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 80 mm diameter pipe |
26 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 15 mm diameter pipe |
27 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
28 | 15 mm nominal bore |
29 | 20 mm nominal bore |
30 | 25 mm nominal bore |
31 | 32 mm nominal bore |
32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
33 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
34 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
35 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
36 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long, weighing not less than 138 gms |
37 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks |
38 | P/F Tank Nippale 15 to 20 mm dia. of approved quality(ISImake) |
39 | P/F gun metal gate valve 15 mm dia. of approved quality(DRP make) |
40 | Charges for disconnecting and loading / unloading the PVC water storage tank500 to 1000 ltr capacity from terrace to Engineering store Maurice Nagar as directed by engineer-in-charge |
41 | Repair of tank plateform with brick work, cement plaster etc complete as per direction of Engineer in-charge. |
42 | Cleaning floor tiles/ wall tiles and all flooring by washing powder & repair joints with white cement in colour pigment for matching etc complete |
43 | Surching and repair the damaged GI pipe line with excavation trenches and charge for labour, repair with GI fittings etc complete as per direction of Engineer –in-charge (40 to 50 mm dia nominal bore) |
44 | Repair of seepgae i/c cleaning traps / repair to GI pipe / clearing blockagewhichever is required as per the site conditionand repairing the seepagefrom the walls by preparing base wall painting etc completeas per the satisfaction of Engineer-in-charge. |
45 | P/F CPVC F T A/ M T A with reducer sokit 20 mm dia. of approved quality(ISImake) |
46 | Repair the damaged GI pipe line with required GI pipe and fittings etc complete as per direction of Engineer –in-charge (15 to 25 mm) |
47 | P/F Go-down lock approved quality with all screws / welding etc complete. |
48 | Repairing the steel gateincluding taking out and refixing, cutting, welding etc. complete as per direction of Engineer in-charge. (Replacement of rusted steel to be paid seprately) |
49 | P/F PVC water storage tank cover 500 to 1000 ltr capacity with locking arrangement etc complete. |
50 | Providing and fixing C.P. brass pillar cock of approved make, 15 mm nominal bore. |
51 | P/F CPVC ball valve 20 mm dia.(Supereme make or equiavlent) of approved quality |
52 | Repair of SCI pipe line in shafti/c taking out and fixing SCI pipe, lead joint etc with necessary repair complete 75 mm to 100 mm dia nominal bore |
53 | Uprooting stay unwanted vegetation/ peepal tree etc from wall and terrace upto floor level i/c repair of damaged wall & plaster and making good the same as per existing finishing as directed by Engineer-in-charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail