}

Tender For 8474 Repair To Compound Walls, Drains, Culverts, Retaining Walls, Concertina Coil, Steels Gates, Chain Link Fencing, Barbed Wire Fencing And Other Misc Repair Works At Nstl Visakhapatnam, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For 8474 Repair To Compound Walls, Drains, Culverts, Retaining Walls, Concertina Coil, Steels Gates, Chain Link Fencing, Barbed Wire Fencing And Other Misc Repair Works At Nstl Visakhapatnam. Submission Date for this Tender is 04-09-2023. Drainage Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39150168
Corrigendum : Tender For 8474 Repair To Compound Walls, Drains, Culverts, Retaining Walls, Concertina Coil, Steels Gates, Chain Link Fencing, Barbed Wire Fencing And Other Misc Repair Works At Nstl Visakhapatnam
Open Tender
Indian
Andhra Pradesh
visakhapatnam
04-09-2023

Tender Details

Tender For 8474 Repair To Compound Walls, Drains, Culverts, Retaining Walls, Concertina Coil, Steels Gates, Chain Link Fencing, Barbed Wire Fencing And Other Misc Repair Works At Nstl Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Aug-2023 8474 Corregendum Other 04-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 75000.0 /-
Tender Value
INR 37.50 Lakhs /-

BOQ Items

Name of Work: REPAIR TO COMPOUND WALLS, DRAINS, CULVERTS, RETAINING WALLS, CONCERTINA COIL, STEELS GATES, CHAIN LINK FENCING, BARBED WIRE FENCING AND OTHER MISC REPAIR WORKS AT NSTL VISAKHAPATNAM
Sl. No. Item Description
1Excavation over areas not excn exc 1.5mts in depth for foundations and gettingout in hard/dense soil all as directed.
2All as per item No. 1 above but depth exc 1.50mts but not exc 3.00mts all as directed.
3Returning filling in, including spreading, levelling watering and well ramming in layers not exc 25cms all as directed.
4Removing excavated soilmaterial to a distance n. Exc 50mts and depositing where directed at a level n exc. 1.5mts all as directed.
5M & L Cement concrete type D2(1:4:8) (using 40mm graded aggregate) as in foundations all as directed.
6S & F Fly ash Brick Masonry straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as directed.
7M & L for TMT Bars 10mm dia and over cut to lengh and bent to shape required including cranking , bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(anneled) not less than 0.90mm dia or securing with clips complete all as directed.
8All as per item No. 7.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
9M & L forRCC M-30 (using 20mm graded aggregate) as in foundations, including rafts, footings and foundation beams, plinth beams, bases for columns etc and mass concrete all as directed.
10M & L for RCC M-30 (using 20mm graded aggregate) as in beams,cantileavers, lintels over 1.5mts span all as directed.
11M & L for RCC M-30 (using 20mm graded aggregate) as in columns, pillars, piers, posts and struts all as directed.
12M & L for Formwork to sides of concrete foundations, footings bases of columns, rafts and raft beams sides and soffits of foundations and plinth beams and similar work vertical or to batter for rough finished surface of concrete flat all as directed.
13M & L for Formwork to sides and soffits of lintels, beams, beam haunchings etc for rough finished surface of concrete flat all as directed.
14M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal for rough finished surface of concrete flat
15M&L Rendering in cm 1:4 10mm thick on fair faces of brick or concrete surfaces finished even andsmooth without using extra cementall as specified and directed by Engineer-in-Charge.
16M&L for preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified. [Make of Exterior emulsion: "Weather Shield Powerflexx" of M/s ICI Dulux/ "Apex Ultima" of M/s Asian Paints/ "WeatherCoat Long Life" of M/s Berger Paints]
17S&F Joist, channel, angle or tee sections fixed independently without connecting plates etc(cut to ordinary lenghts i.e within 20mm of the length indicated) grade Fe-410-W(Gde-e-250) quality A
18S&F Framed work as in doors or gates of angle or other sections with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other coverings. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheetings or other coverings running rails and guiders) and hanging also fastening and fixing complete Fe-410-W(Gde-e-250) quality A
19M & L forPreparing new steel surfaces and appling two coats of synthetic enamel paint over a coat of red oxide primer
20S & F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
21Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 metre openable length having 50 Nos rounds per 6 meter length(before stretching) on upto 3m height of wall with Y shaped angle iron brackets placed 2.4m to 3.00m apart, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron with reinforced barbed tape(R.B.T)/ spring core92.5mm thick) wie of high tensile strength of 165KG/sq.cm with tape(0.52mm thick) and weight 43.478gm/m complete all as specified and as directed
22Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles.
23Taking down cement or cement lime plaster on brick or stone walls etc incl raking out joints, hacking for key scrubbing down with water etc.
24M & L for rendering 5mm thick with WPC over 10 mm thick on concrete surfaces or fair face of brick work or PCC block masonry in CM 1:4 finishing the surfaces fair and even
25M & L for preparation of new surfaces of walls over alkali resitant primer & applying two coats of cement base paint.
26M & L for preparing old plastered surfaces of walls by brooming down and applying one coat of cement base paint all as specified.
27M&L for complete removal of existing treatment on external surfaces of walls applying two coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified.[Make of Exterior emulsion: "Weather Shield Powerflexx" of M/s ICI Dulux/ "Apex Ultima" of M/s Asian Paints/ "WeatherCoat Long Life" of M/s Berger Paints]
28Chipping of unsound/weak concrete material in patched n exc 10 Sqm for 15mm average thickness from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. complete with necessary scaffolding/ staging and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
29Cleaning of reinforcement in pathes n exc 15RM from rust from the reinforcing bars of dia upto 12mm to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
30M & L for mixing and applying SBR polymermodified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) 15mm average thickness in three layers as per specifications and directions of Engineer-in-charge Note: Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument.
31M&L for preparation of old decorated surfaces of walls and cornices by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of white wash complete all as specified and as directed.
32M&Lfor preparation of old painted surfaces of walls and applying one or more coats of synthetic enamel paint complete all as specified and as directed.
33M&Lfor preparation of old painted steel and iron surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
34M&Lfor preparation of previously untreated old painted steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coat of synthetic enamel paint over a red oxide primer complete all as specified and as directed.
35Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
36M&L for non - skid coloured ceramic tiles 7 to 8mm thick, 300x300mm size, in floors etc., set and jointed in neat cement slurry and pointed incoloured cement to match laid over and including 15mm thick screed bed in CM (1:4) complete all as specified.
37M&L for glazed ceramic digitally printed tiles of size 300x450mm, 7mm thick in vertical surfaces of wall, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 10mm thick backing coat in CM 1:3 complete all as specified.
38M&L for vitrified tiles, double charged, first quality of size 600x600mm, 9 to 10mm thick as in Floors, set and jointed in cement slurry, finished with flush pointing in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. [Note: The colour / shade / design of tiles shall be as approved by AGE (I)]
39M&L for vitrified tiles, double charged, first quality for skirting cut from tiles of size 600x600mm, 9 to 10mm thick, to suit the size of floor tile, set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles over and including backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed. [Note: The colour / shade / design of tiles shall be as approved by AGE (I)]
40Dismantling of stone slab or tilesof any description in floors, aprons etc., laid bedded and pointed in any mortar all as specified and directed.
41M&L chequered cement concrete tiles25cmx25cmx25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4 as specified and directed.
42Supply and laying 60mm thick Machine Pressed Precast Concrete M-35 Grade, Interlocking Paver Blocks, PVC mould reflective type conforming to IS - 15658 of any shape and size with Grey cement and pigment complete laidall as specified and as directed.
43M & L sand filling under floors or in foundation including watering & consolidation all as directed.
44Demolition of cement concrete etc in any description/any location not exceeding 15 cm thickness all as directed.
45M & L for cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) 25mm thick finished fair & even w/o using extra cement all as directed.
46M & L cement concrete type C2, 1:3:6 (40mm graded aggregate) 75 mm thick as in sub base levelling course all as directed.
47M & L for tandoor/kota/terrazzo tiles of any description forgrinding, polishing and waxing (whereever needed) as per instructions of Engr-in-charge
48M & L providingcement concrete type C1 1:2:4 (20cm graded aggregate) in coping work, over chajjas , Compound walls and other similar works etc complete with necessary scaffolding/ staging/ Jhula etc, with all necessary safety precautions up to 4 storey height complete all as directed and as specified.
49M & L for walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work all as directed.
50M & L for walling of random rubble, uncoursed as built in cement mortar 1:6 with stone all as directed.
51M & L for walling of random rubble, uncoursed as built in cement mortar 1:6 but except stone all as directed.
52m & L for Keyed pointing to random or polygonal rubble, uncoursed or brought upto course all as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail