Tender For Repair Maintenance Of Vcb, Transformers, Ht Ug Cable, Oh Acsr Conductor Allied Work At Af Station Darbhanga Under Ge Af Bihta, darbhanga-Bihar

Military Engineer Services-MES has published Tender For Repair Maintenance Of Vcb, Transformers, Ht Ug Cable, Oh Acsr Conductor Allied Work At Af Station Darbhanga Under Ge Af Bihta. Submission Date for this Tender is 18-09-2023. Circuit Breakers Tenders in darbhanga Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

39129438
Corrigendum : Tender For Repair Maintenance Of Vcb, Transformers, Ht Ug Cable, Oh Acsr Conductor Allied Work At Af Station Darbhanga Under Ge Af Bihta
Open Tender
Indian
Bihar
darbhanga
18-09-2023

Tender Details

Tender For Repair Maintenance Of Vcb, Transformers, Ht Ug Cable, Oh Acsr Conductor Allied Work At Af Station Darbhanga Under Ge Af Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-09-2023
2 13-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 19100.0 /-
Tender Value
INR 9.55 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR/MAINT OF VCB, TRANSFORMERS, HT UG CABLE, O/H ACSR CONDUCTOR & ALLIED WORK AT AF STATION DARBHANGA UNDER GE (AF) BIHTA
Sl. No. Item Description
1Supply and laying synthetic Rubberinsulating mat of size 2m X 1m X 2.5mm for voltage upto 11 KV complete all as specified and directed
2S&F in replacement ofPin type,porcelain ,vitreous,white , brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia for 11000 volt grade complete all as specified and directed .
3S&F in replacement ofDisc type insulator, porcelain, vitreous, 145 mm height and 255 mm dia , ball and socket type, white, brown or green single disc assembly complete all as specified and directed. .
4Dismantling cross arms of mild steel channel or angle section from the poleand setting out complete all as specified and as directed.
5S&F cross arms, bracings, suports, clamps, back plates etc., fabricted with strututral steel sectionsincluding bolts, nuts, washers etc., welding , bending cold or hot,drilling holes for bolts,in any shape or size,as indicated or as directedincluding applying two coats of synthetic enamel paint over one coat of red oxide primer including preperation of steel surfaces complete all as specified and as directed.
6S&F Danger Notice boardmade out of 1.6 mm thick mild steel sheet ofsize 25 cm X 20 cm , vitreous, enamelled white with letters , figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts, nuts for HT 11000 Volts complete all as specified and as directed.
7S&F Lightning Arrestor, expulsion type complete with all fittings, transmission class, discahrge capacity 65 Kilo amps suitable for 11000 Volts complete all as specified and as directed.
8M&L for painting of transformer 100 to 315 KVA by scrubbing out dust, dirt and oil from all places and applying two coats of grey synthetic enamel paint by spray machine, writing MES/SM No as per existing pattern inluding disconnecting and taking down including reconnecting and refixing the same in its position complete all as specified and as directed.
9Taking down/refixingdefective transformer upto 315 KVA capacity and VCBfrom poles/structures after disconnecting all electrical connections removing to sub station or workshop as directed, placing the repaired transformer in place of taken down defective transformer including transportation, loading, unloading of transformer from sub station to work site or work shop and connecting HV and LV side including all connecting and jointing materials such as suitable size of lugs, bolts, nuts etc complete all as specified and as directed.
10Opening/striping off transformer 11 KV/0.433 KV step down capacity upto 315 KVA including draining off oil, lifting the core and coil assembly washing and cleaning dust, dirt and sludge deposit etc from all parts, removing damaged or defective parts requires replacement, making internal connection, servicing of tap changer and re assembling the transformer after repair and replacement work including new cork sheet gasket, packing, nuts, bolts, washer etc as required filling fresh transformer oil and testing complete including replacement of the following items:- (a)High voltage/low voltage coil including double paper insulated conductor of same gauge as per existing and all insulating material varnishing with vaccum impregnation and baking of coil suitable for upto 315 KVA capacities of step down transformers of aluminium/copper wound. (b) HV bushing of 12 KV grade with gasket complete. (c ) LV bushing of 1100 volts grade with gasket suitable for transformer upto 315 KVA capacity (d) LV brass studs with brass nuts, check nuts, washers etc complete for transformers upto 315 KVA complete. (e) HV brass studs with brass nuts, check nuts, washers etc complete for transformers upto 315 KVA complete. (f) Replacement of breather with fresh filling of silica gel 0.5 Kg capacity in non metallic transparent enclosure for transformer up to 500 KVA capacity complete. (g) Insulating transformer oil conforming to IS-335 for filling/toping up of transformers not less then 100 litre quantity duly filtered having dielectric breaking strength not less than 40 KV at the gap of 4mm complete.
11Maintenance and complete overhauling and calibrationof 11 KV VCB including dismantling of Vaccum intrrrupter bottel, trip coil,closing coil, Auxilary switch, spring limet switch,braker limet switch mechanical parts, well cleaning with petrol and CRC-226, replacing of moving parts, reassembly, fine setting of mechanism, replacement of unserviceable parts and reassembly of parts including well cleaning the complete panel board decarburization of all joints, metal parts and making VCB perfect operating condition including all routine and preventive maintenance complete and Servicing of HT,11 KV,VCB, 50 Hz,breaking capacity 630Amp , 20 KA trollyby drawing out from panel chamber including removing carbon deposits from moving/fixed contact points,greasing and tightening all fixed and moving contacts for smooth functioning including replacement of tripping and closing coils as per existingand servicing of solenoid switch all as specified and as directed including supply and fixing thefollowingaccessories :- (a) Voltage meter HT - 1No (b) Amp meter -3 Nos (c ) LED Indicating lamp RYB -3 Set (d) 3 PH Overcurrent & earth fault relay Art no 1MYN742838 Make ABB - 02 Nos (e) Vaccum intrrrupter bottel (f)Trip coil (g) Closing coil (h) Auxilary switch (i) Spring limet switch (j)Braker limet switch (k) Relay
12Supply and filling insulating transformer oil conforming to IS-335 for filling or toping up of transformers as required at site duly filtered having dielectric strength not less than 50 KV at 4 mm gap complete all as specified and as directed. Note :- Transformer oil shall bebrought at site in sealed drum.
13Dehydration of transformer oil both factory and site of work including heating, filtration, cleaning and testing required upto dielectric strength 50 KV in 4mm gap and testingtothe satisfaction and after dehydration complete all as specified and as directed.
14Cutting / trimming and removing tree branches close to the or touching the electric overhead lines HT / LT or at sub stations etc by climbing on the tree with necessary safety precautions, tools ,removing , transporting the cut branches from site and depositing where directed at a distence not exceeding 300 m complete all as specified and as directed. Note :- Shut down of electric supply shall be taken before commencement of work. Any damage to existing OH lines / services etc shall be made good without any extra cost.
15M&L cleaning and preperation of surfaces by scrubbing with wire brushes, emery papers etc from all metalic surfaces of mild steel tubular HT electric poles , any type , any model not more than 11 m long including cross arms, clamps etc any size on the same pole and applying one coat of aluminium paint on pole,cross arms, clamps, GI pipes brackets etc including writting of pole numberas per existing size and pattern complete all as specified and as directed.
16S&F in replacement ofAir break gang operated switch , HT, 11000 volts,Triple pole mechanically operated, vertical/horizontal ,mounted on insulators and steel frames with operating mechanism worked from ground level with operating rod, handle etc forcurrent rating up to 400 Amps fixed on pole or stucturescomplete all as specified and directed .
17Supply and laying cable95 Sqmm 3 core , XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 11000(E) Volts grade with stranded aluminium conductor including taking out old unserviceable cable from trenches or duct or pole,complete all as specified and directed .
18S&F Cable joining kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
19S& F Cable joining kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
20Excavation In trenches not exceeding 1.5 m In depthand not exceeding 1.5 mwidth and getting out in soft/loose soil for laying of cables or pipes, erection of poles, stays, cable fault detection etc complete all as specified and as directed.
21Returning, filling in, including spreading leveling watering with ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed.
22Removing excavated soil not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
23Supply & laying sand cushioning for cable protection in trenches 8 cm thick before laying cable and 15 cm thick over the cableand punning down to 18 cm complete all as specified and ditected. Note:-Punned thickness shall be measured and paid.
24Supply & laying brick sub class "B for protection of cablelaid dry flat across the cable with width equal to the length of whole brickscomplete all as specified and ditected.
25Dismantlingof existing unserviceable stay assembly complete all as specified and as directed
26M&L for stay assemblyhavingdiameter of stay rod 20 mmcomplete with accessories as shown in electrical plate No. 1of SSR Part-I 2009 completeall as specified and directed. Note :- Loop type insulator, stay clamps, excavation and earth work including concrete shall be measured separately under respective item as considered therein.
27M&L Cement concrete 1:3:6 typeC-2 using 40 mm graded stone aggregate as foundation and mass concrete including necessary use and waste of form workas required complete all as specifedand as directed.
28M&L Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundationand mass concrete complete all as specified and directed.
29M&L for earthing complete with copper plate 60cm×60cm ×3 mm thick electrode and buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 m below ground level) connected to copper strip25mmx3mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I 2009 with connected to earth test point and to main switch boardincluding adequate quantity of charcoal dust and common salt alround earth plate and 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel and wire meshincluding necessary excavation andearth work, PCC1: 3 : 6type C-1 using 20 mm graded stone aggregate as in earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate reinforced with8 mm dia TMT bars @ 75 mm c/cboth ways with 12mm diamild steel round bar handle completeall as specified and directed including testing on completion. NOTE:- Earth lead wire and its protection pipe upto and including 7.5 m only from the top of earth electrode are included under this item and additional earth strip/protection pipeif any required at site shall be measured and paid for separately under respective item.
30S&F Earth continuity conductor or main earthing lead 25mm X 3mm, aluminum stripfixed in any position including jointing by existing tinned copper/brass nuts, bolts and washersand brazing with gas welding using brass electroded complete all as specified and directed.
31S&F Earth continuity conductor or main earthing lead 20mm X 3mm, copper stripfixed in any position including jointing by existing tinned copper/brass nuts, bolts and washersand brazing with gas welding using brass electroded complete all as specified and directed.
32S&F HTcable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for35 Sqmm , 3 core XLPE armored aluminum cable complete all as specifed and as directed.
33S&F HTcable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for95 Sqmm , 3 core XLPE armored aluminum cable complete all as specifed and as directed.
34S&F HTcable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for185 Sqmm , 3 core XLPE armored aluminum cable complete all as specifed and as directed.
35Dismantling of old unserviceable Steel tubular pole 11.00 m long and removing from site complete all as specified and directed.
36Supply and erection of steel tubular swaged pole , type 410-SP 55 (LT 11.00 mtr long pole) complete conforming to IS: 2713 complete with CI base plate, pole cap, bolts, nuts and screwcomplete all as specifiedand includingof following works:- (a) Excavation in trenches as required , returning fillingand disposal of surplus soil to a distance not exceeding 50 m (b)PCC 1:4:8, type D-2 using 40mm graded stone aggregate in foundation 900mmx600mm cross section and planting depth 1.5 m for concrete encasing the pole upto GL (c) PCC 1:3:6, type C-1 using 20mm graded stone aggregate for plinth block/collar above GL 500mm high and 450mm dia (d) Painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over a coat of red oxide primer including preparation of surface andpainting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block (e) Writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole (f)Painting of coping withtwo coats of cement based paint . Note : Manufacture"s test certificate shall be produced alongwith purchase vouchers .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail