Tender For Survey, Investigation, Design, Build, Operate And Transfer Of Interception, Diversion And Treatment Works With Allied Works Including 15 Year Operation And Maintenance Of These I And D Works At Banat, District Shamli, U.P. Under Namami Gan, shamli-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Tender For Survey, Investigation, Design, Build, Operate And Transfer Of Interception, Diversion And Treatment Works With Allied Works Including 15 Year Operation And Maintenance Of These I And D Works At Banat, District Shamli, U.P. Under Namami Gan. Submission Date for this Tender is 09-11-2023. Water Treatment Plant Tenders in shamli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39120252
Corrigendum : Tender For Survey, Investigation, Design, Build, Operate And Transfer Of Interception, Diversion And Treatment Works With Allied Works Including 15 Year Operation And Maintenance Of These I And D Works At Banat, District Shamli, U.P. Under Namami Gan
Open Tender
Indian
Uttar Pradesh
shamli
09-11-2023

Tender Details

Survey, Investigation, Design, Build, Operate And Transfer Of Interception, Diversion And Treatment Works With Allied Works Including 15 Year Operation And Maintenance Of These I And D Works At Banat, District Shamli, U.P. Under Namami Gange Programm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Sep-2023 Crrigendum no 1 Date 20-10-2023
2 11-Oct-2023 Revised BOQ Other 20-10-2023
3 19-Oct-2023 Revised bid submission date Date 06-11-2023
4 03-Nov-2023 Rerevised BOQ Other 06-11-2023
5 04-Nov-2023 Revised bid submission date. Date 09-11-2023

Key Value

Document Fees
INR 23600 /-
EMD
INR 4770000.0 /-
Tender Value
INR 41.72 Crore /-

BOQ Items

Name of Work:I&D and 5 MLD STP Works at Banat town, District Shamli in Uttar Pradesh State Under Namami Gange Mission-II.
Sl. No. Item Description
1Construction of 5 MLD STP at Banat:Design,development,supplyofequipment, erection of equipment, civil, electro mechanical andinstrumentationworks,including testing, commissioning of 05 MLD STP inBanat, District Shamli on open technology with disinfection, provision for handling co treatment of septage/faecal sludge (05 KLD) facility like, collection tank, fine/coarse screen sitting chamber, equilization tank, filter press/belt press/screw press for dewatering etc. of septage/faecal sludge, provision for filtration unit in the tertiary treatment to cater shock loads and allied works, provision of covered Sludge Storage Yard for 30 days storage of dewatered sludge. The scope of work also includes providing all material, labour T&P etc. and construction of electrical sub station, D.G. Sets,substation building, meter room, panel rooms with DG sets, transformers and switch gears, Construction of transformer yard, Platform for D.G., shed over the generators,fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP, provision of adequate CCTV camera arrangement along with Static IP Address for monitoring and provision of water reuse facility. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned). The scope also including. Ancillary works like R.C.C. approch road in 3.75 m width with 1.5 m wide inter locking shoulder each side from,approach road to proposed STP, entry gate, boundary wall of campus with gate, staff quarters, internal C.C. roads 3.75 m wide and 2.0 m wide C.C. path ways, water supply arrangement, fire fighting arrangement, land scaping, site development & require furniture etc. and other works as defined in bid documents.
2Break-up of price of item 1 above.
3Civil and Structural Works (including that required for disposal and facility for reuse of treated effluent)
4Supply, Installation, testing and commissioning of Electro – mechanical and Instrumentation equipment and accessories including equipment for electricity generation from solar photovoltaic arrangement (including required for disposal and facility for reuse of treatet effluent) .
5Ancillary works like boundary wall of campus with gate, RCC retaining wall along River and two sides along with other appurtenant works, staff quarter type 2 Nos.(1-Type A and 1 Type B), internal C.C. roads 3.75 m wide and 2.0 m wide C.C. path ways to various units, approach/access road to STP, 50 KL RCC OHT & Pump House and water distribution system and drainage system in the STP campus, retaining wall, earth filling up-to the nearest road level or HFL whichever is higher, horticulture works, Outfall structure at disposal point, firefighting arrangementswater supply arrangement, fire fighting arrangement, land scaping, site development & require furniture etc.
6Implementation of Environmental Management Plan and ESHS-MSIP, as per Appendix 1 of Schedule 2 (Design Build Services).
7Nalla Tapping Arrangement: Survey, design and construction of suitable size R.C.C. (M-30) Nala tapping structure as per design at Banat town with RCC M-30 training works at upstream and downstream of tapping point upto suitable length and installation of required number Stainless Steel sluice gates to regulate the flow along with construction of inlet channel and installation of stainless steel coarse screen and proper arrangement for operating platform.
8Nallah tapping works at drain -1
9Nallah tapping works at drain -2
10Laying of Gravity Intercepting Sewer: Design, supply & laying of following sizeR.C.C. Hume pipe NP-3 Class Socket spigot pipes, rubber rings jointing materials and specials from store to the work lowering the same in to the trenches up to depth as specified below G.L. true to alignment and gradient including barricading of site, traffic diversion arrangement, dismantling of roads, mechanical/ manual excavation, dewatering (as per requirement), shoring & timbering with mild steel/ wooden planks, construction of required class beddings, construction of RCC/ brick masonry circular/ rectangular or precast manholes in accordance with the provisions laid down in latest version of IS 4111 (Part 1), refilling of trenches with proper compaction including disposal of surplus earth with in 8 km radius, temporary reinstatement of dismantled roads, permanant restoration of road as per PWD/MoRTH norms, shifting & reinstatement of existing utilities if any, cost of all jointing material, testing & commissioning etc. complete including supply of all material, labour, T&P etc. required for proper completion of work.
11300 mm dia RCC NP-3 Pipe
12Main Sewage Pumping Station : Design and construction of main pumping station of 5 MLD capacity including construction of Sump well , receiving chamber, screen chamber, Pump house, Panel room, DG/Transformer yard, Panel & PLC Room, internal road, site development works along with supply, installation and commissioning of suitable capacity non-clog submersible pumps (MOC- Casing- 2%NiCI, Impeller- Duplex SS, Shaft & Shaft sleeve- Duplex SS) capable of pumping 100 mm particle with necessary accesseries such as motors, panals, cabeling, valves, pipings etc,D.G. set of suitable capacity with necessary accessaries, one no. Electromagnetic Flowmeter cum totalizer, Automation of MPS, one nos Mechanical screens, one no. Manual screen, two nos. Transformers and Substation, provision for supply and installation of5T capacity chain pulley block with traveling trolley with 15 meter lift with girder etc with necessary tools and spares, provision for testing of each pump set, valves etc. at manufacturer works and at site, painting of all pumps piping and valves with two coat enamel paint, supply and installation of AMF panel with associated works, supply and installation of actuated sluice gates with associated works etc. including Installation, commissioning and testing of all E&M equipments complete to the satisfaction of engineer in charge. Civils component of the MPS shall be designed for 6 MLD capacity.E&M component of the MPS shall be designed for 5 MLD capacity.
13Civil and Structural Works (including that required for disposal and facility for reuse of treated effluent)
14Supply, Installation, testing and commissioning of Electro – mechanical and Instrumentation equipment and accessories (including that required for disposal and facility for reuse of treated effluent)
15Rising main from MPS to STP
16Design, supply and laying of following diameter DI K-9 pipe Pressure Pipes (S&S) with out side Zinc coating with finishing layer of Bitumen and have factory internal cement mortar lining in SRC cement for sewerage confirming to IS 8329:2000 (amended upto date) with push on type EPDM "ISI marked" rubber gasket (including cost of rubber gasket) joining as per IS 5382 specifications with hydraulic field testing, commissioning as per specifications, providing, Erecting, Testing, Commissioning of C.I. double ball orifice typeAir Valve, construction of air valve chamber as per type design including supply & fixing of 500 mm dia medium duty perforated C.I. cover, Providing, Erecting, Testing, Commissioning, of Scour/Drain Valve with construction of chambers including dismanteling & permanant restoration of road as per PWD/MoRTH norms, excavation by manually or mechanically in inordinary soil (earth, sand, loam & clay) includingramming dressing, leveling by manually or mechanically, refilling of trenches in 15cm layer watering and ramming the same including removal of surplus earth or other dismantled material upto a distance of 500 m from the centre of trenches/trenchless technology, construction of required necessary thrust blocks,complete to the satisfaction of engineer in charge.
17300 mm DI K-9 pipe
18Treated Effluent Pipeline:
19Design, supply and laying of following diameter DI K-9 pipe Pressure Pipes (S&S) with out side Zinc coating with finishing layer of Bitumen and have factory internal cement mortar lining in SRC cement for sewerage confirming to IS 8329:2000 (amended upto date) with push on type EPDM "ISI marked" rubber gasket (including cost of rubber gasket) joining as per IS 5382 specifications with hydraulic field testing, commissioning as per specifications from STP to agriculture land for irrigation with suitable arrangement and also at outfall point at Shamli drain with suitable outfall structure to discharge effluent with protection workstrue to alignment and slope as per design, excavation, jointing, hydraulic testing and commissioning with necessary timbering, proper barricading approved by engineer in charge, bedding, backfilling with fine sand including dismanteling and permanant restoration of road as per PWD/MoRTH norms as required, shifting & reinstatement of existing utilities if any, bailing out of water, construction of R.C.C. Manholes with heavy duty SFRC covers as per CPHEEO manual, disposal of surplus earth as per direction of engineer in charge, supply of all materials, labor and T&P etc. complete to the satisfaction of engineer in charge.
20500 mm DI K-9 pipe
21Operation and Maintenance for 15 Years
22STP (PART A) Operation and Maintenance Price for Treatment of threshold sewage flow of 5 MLD at STP & Co- Treatment facility (5 KLD)) with all civil, electrical-mechanical and instrumentation works, effluent chanel, appurtenant and other allied works for 15 years as specified in tender document and as per norms of CPHEEO manual on Sewerage and Sewage Treatment System-2013 (Bidder is required to quote the year wise O&M price for 15 years
231st year
242nd year
253rd year
264th year
275th year
286th year
297th year
308th year
319th year
3210th year
3311th year
3412th year
3513th year
3614th year
3715th year
38PART B AdditionalOperation and Maintenance Price for Treatment of additional sewage in excess of the threshold on per MLD basis flow at STP & Co- Treatment facility (5 KLD) with all civil, electrical-mechanical and instrumentation works, effluent chanel, appurtenant and other allied works for 15 years as specified in tender document and as per norms of CPHEEO manual on Sewerage and Sewage Treatment System-2013
391st year
402nd year
413rd year
424th year
435th year
446th year
457th year
468th year
479th year
4810th year
4911th year
5012th year
5113th year
5214th year
5315th year
54Total O&M Price- assuming indicative Sewage Flow reaching the STP C=a+b x (x= indicative flow minus threshold sewage flow)
551st year (X=3.27-3.27=0)
562nd year (X=3.40-3.27=0.13)
573rd year (X=3.52-3.27=0.25)
584th year (X=3.64-3.27=0.37)
595th year(X=3.77-3.27=0.50)
606th year(X=3.89-3.27=0.62)
617th year(X=4.01-3.27=0.74)
628th year(X=4.14-3.27=0.87)
639th year (X=4.26-3.27=0.99)
6410th year (X=4.38-3.27=1.11)
6511th year (X=4.51-3.27=1.24)
6612th year (X=4.63-3.27=1.36)
6713th year (X=4.75-3.27=1.48)
6814th year (X=4.88-3.27=1.61)
6915th year (X=5-3.27=1.73)
70Operation and Maintenance cost of MPS, tapping, interceptor sewer, effluent pipe line and rising main with all civil, electrical-mechanical and instrumentation works, appurtenant and other allied works for 15 years as specified in tender document and as per norms of CPHEEO manual on Sewerage and Sewage Treatment System-2013 (Bidder is required to quote the year wise O&M price for 15 years
711st year
722nd year
733rd year
744th year
755th year
766th year
777th year
788th year
799th year
8010th year
8111th year
8212th year
8313th year
8414th year
8515th year
86Total O&M Price
871st year
882nd year
893rd year
904th year
915th year
926th year
937th year
948th year
959th year
9610th year
9711th year
9812th year
9913th year
10014th year
10115th year
102NPV of total O&M
1031st year (NPV Factor-0.909)
1042nd year(NPV Factor-0.826)
1053rd year(NPV Factor-0.751)
1064th year(NPV Factor-0.683)
1075th year(NPV Factor-0.621)
1086th year(NPV Factor-0.564)
1097th year(NPV Factor-0.513)
1108th year(NPV Factor-0.467)
1119th year(NPV Factor-0.424)
11210th year(NPV Factor-0.386)
11311th year(NPV Factor-0.350)
11412th year(NPV Factor-0.319)
11513th year(NPV Factor-0.290)
11614th year(NPV Factor-0.263)
11715th year(NPV Factor-0.239)
118Electricity and fuel charges during O&M for 15 Years
119Guaranteed Energy Consumption for 05 MLD STP at Banat town for the first month after successful trial run (Value should be entered in all cell of rows 13.02 to 13.05, after adjusting for energy generated through solar power plant if proposed to be installed)
120For flow upto 3.27 MLD and BOD = 125 mg/L
121For flow upto 3.27 MLD and BOD > 125 mg/L
122For flow > 3.27 MLD and BOD=125 mg/L
123For flow > 3.27 MLD and BOD > 125 mg/L
124STP Average GEC
125Power Charges for 05 MLD STP at Banat town for Indicative Flow (= Sum of indicative flows in MLD X Units Consumed/MLD X 365 X 7.74 ) (Not to be filled by the Bidder)
126Guaranteed Energy Consumption for 5 MLD MPS at Banat town for the first month after successful trial run (Value must be entered for rows at S. No. 14.01 and 14.02 )
127For flow upto 3.27 MLD
128For flow >3.27 MLD
129SPS Average GEC
130Power Charges for 05 MLD MPS at Banat town for Indicative Flow (= Sum of indicative flows in MLD X Units Consumed/MLD X 365 X 7.74 ) (Not to be filled by the Bidder)
131Add GST (Excluding Sl.No. 12, 13, 14)
132Land requirement (sqm) - 05 MLD STP at Banat town (Circle rate is Rs 1260 per sq.m.) (Bidder is required to quote the land requirement under column 5 of this row including land required for Solar Power Plant if proposed, subject to lavailable land i.e. 2870 sqm)
133Total in Figures (based on NPV of O&M Price and including Land Price)
134Total in Figures (based on actual O&M Price and excluding Land Price)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail