Project Description

Construction Of Block Public Health Unit Building, At-Tandwa

BOQ

Name of Work:Construction of Block public health unit, At-Tandwa, Block-Tandwa, Dist. Chatra.
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction
2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
3Earth filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as perbuilding specification and direction of E/I.(mode of measurement
4Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
61:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate40 mm nominal size)
7Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stoneaggregate 20mm nominal size).
8Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand, includingnecessaryexcavation,levelling& dressing & finishing thetop smooth.
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
10Reinforcedcementconcreteworkinbeams,suspendedfloors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mmnominal size).
11Reinforcedcementconcreteworkinbeams,suspendedfloors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mmnominal size).
12Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stoneaggregate 20 mmnominal size)
13Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. formass concrete
14Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Columns, Pillars, Piers, Abutments, Posts and Struts
16Suspended floors, roofs, landings, balconies and access platform
17providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid forSAIL & TATA STEEL)
18providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
19(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})
20(c) 16mm (TMT coil Fe 500) (only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})
21providing Tor steel reinforcement of 20mm,25mm, 28mm & 32mm. dia bars as per approved design and drawing exclusive carriage ofM.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 20/25mm TMT bar Fe 500 (only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})
22Providing designation 75B brick work inC.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
23Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
24Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
2575mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095:(part I): 2011 (Board with BIS certification marks
26Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Fixing with adjustable lugs with split end tail to each jamb
27Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
28Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
29Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete
30Providing and fixing aluminium tubular handle bar 32 mm outer dia,3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge Powder coated minimum thickness 50 micron aluminium tubular handle bar
31Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) foraluminium doors including necessary cutting and making good etc.complete.
32Providing average 150mm thick dry rammed khoa beaten to112mm.(compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thckness is achieved, curing and carriage of water with all leads,making proper slope and blending the top with cement morter (1:10) all complete as per building specification and direction of E/I
33Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
34Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
35Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matchingpigment etc., complete.
36Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm
37Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-ChargeGranite work
38Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.complete
39Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand Acid and alkali resistant tile
40In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
41Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
42Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
43Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as perbuilding specification and direction of E/I.
44Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as perstandard design In 75x75 mm deep chase
45Waterproofing for Old and New RoofSlab :-Providingandlaying waterproofing treatment onroof slabby applyingtwo Component, factory designed, ready to use, acrylic modifiedflexible
46Covering of treated surface with PCC:- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope inalternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm
47Providing and filling of 6 mm thickGroove between 50 mm PCC Panels with 6 mm thick 25 mmdeep thermocol strip and filling the rest 25 mm withPolysulphide Sealant (Poring Grade)as per
48Providing 12mm thick cement plaster (1:3) withclean coarsesand ofF.M.1.5includingscreening,curingwithallleadsandliftsofwater scaffolding taxes and royalty all complete as per building specification and direction of E/l.
49Providing 12mm cement plaster (1:6) with clean coarse sand of F.M.1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
50Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specificationand direction of E/I.
51Providing 1.5mm thick cement punning, curing with all leads and lifts as per building specification and direction of E/l.
52Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
53Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete
54New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm
55Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
56Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately For fixed portion Powder coatedaluminium (minimum thickness of powder coating 50 micron
57For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
58Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
59Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete Upto 5mm depth and 5 mm width
60Wiringforlightpoint/fanpoint/exhaustfanpoint/callbellpoint with1.5sq mm FR PVC insulatedcopper conductorsingle core cable in surface / recessed PVC conduit with modular type, GroupC
61Wiringforlight/powerplugwith4x4sq.mmFRPVCinsulatedcopper conductor single core cable
62Wiring for circuit/submain wiring alongwith earth wire-do-2x1.5 sq.mm + 1x1.5 sq.mm earth wire
632x2.5 sq.mm + 1x2.5 sq.mm earth wire
64TV cable in existing conduit -Supplying and drawing co-axial TV cable RG-6 grade 0.7 mm solid copperconductor,PEinsulated,shieldedwithfinetinnedcopper braid and protected with PVC sheath in the existing surface/recessed PVC conduit as required.
65Supplying and fixing of following size of pvc conduitalong with theaccessories insurface/recessincludingcuttingthewalland making good the same in case of recessed conduit as required 32mm dia
6625mm dia
67Supplyingandfixingfollowingmodulartypeswitch/socketonthe existing switch box/cover 5/6 amps, one way switch
6815/16 amps, one way switch
695/6 amps, 3 pin socket outlet
705/16 amps, 6 pin socket outlet
71Tv antena socket outlet
72S/FModulartypesteppedtubeelectronicfanregulator onthe existingplateswitchboxincludingconnectionbutexcludingmodular plate etc as required
73S/FModularblankingplateonthe excludingmodularplate&switch box excluding modular plateetc as required.
74supplyingandfixingfollowing sizes/modules,GIboxalonwith modular base & cover plate for modular switches in recess etc as required 1 or 2 module (78mm x 78mmx 45mm)-for telephone &tv outlet
754/5 module (78mm x 140mm x 50mm)
768/9 module (78mm x 230mm x 60mm)
77S/F Ceiling Rose:- Supplyingand fixing2pinceilingroseontheexistingjunctionbox/ wooden block including connection etc as required.
78S/F Batten / Angle Holder:- Supplyingandfixingbatten/angleholderincludingconnectionetcas required.
79Supplying and fixing ding dong sound call bell single phase, 230 voltscomplete as required.
80ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting/compactfluorescentfittingofalltypes,completewithall accessories and tube etc, directly on ceiling / wall, including connectionwith 1.5 Sq. mm. FR PVC insulated, copper cond.
81ITC Ceiling Fan:- Installation,testingandcommissioningofceiling fan,includingwiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cableetc, as required.
82Installation of exhaust fan / Wall Fan upto 450 mm sweep in the existing opening,includingmakingtheholetocutthesizeoftheabove fan, makinggoodthedamage, includingconnection,testing,commissioning etc as required.
83SupplyingandfixingfollowingwayshortzontaltypethreePole and neutral sheet,MCB distribution board 415 volts on ------do--- (butwithoutMCB/RCCB/isolator)6way(4+18)DoubleDoorHorzontal Type.
84Supplying and fixing 6 Amp to 32 Amp rating 240 volts ,10 KA \"C\" Curve miniture circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connectionsrestingandcomminisingetcasrequired 6/32Ampsingle pole
8540 amp TPN
866/32 Amp TPN
87SupplyingANDFixingoffollowingratingdoublepole(single pole & neutral ).240 volts,resudual current circuit breaker (RCCB),having a sensivity current 30 miliampere in the existing MCBDBcompletewithconnections,testing& comminissioningetc as required. 63 Amps
88Providing and fixing M.V.danger notice plate of 200mm x 150mm of made mild steel at lest 2 mm thick……………do E/I
89earthing with G.I. earth plate 600 mmx600 mmx6mm thick includingaccessories and providing masonary enclouser with cover……………………do E/I
90Providing and fixing 6 SWG dia G.I. WIRE ON SURFACE OR IN RECESS FOR LOOP EARTHING ALONG WITH EXISTING…………………………….DO E/I
91S.I.T.C.offollowingratingsurfacemountedLEDtubelighting fitting suitable for 230V ,50 hz ,single phase supply etc. completeas
9210/12W LED tube light
9320/22W LED tube light
94Supply of12\"(300mm) MetalexhaustFanBajaj/Cromptonorany other approved make etc
95Supply,Installation,TestingandCommissioningoffollowingsize fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as required 1200mm (48\") BLDC 5star rating 32W Ceiling Fan
96Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With \"P\" trap of parry hindustan or any other approvedI.S.S.Makeincludingsupplyingandfixing15litresC.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flushpipewithbrasscouplingandplumbersjointsspindlestop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathenepipe45cmlongwithbrasscouplingatbothendsand white/ black plastic solid state seal and lead of commander/cuckoo orotherI.S.S.makewithhingesorscrewsetc.paintingpipeand cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I.(i) With \"P\" trap(b) 10 lit. Low level PVCCistern
97Supplyingfittingandfixingvitreouswhiteglazedearthenware wash hand basin of parry or Hindustan or any other I.S.S. Approved makesupportedonpaintedC.I.OrR.S.Bracket32mmC.I.Brass waste,15mmdiaC.I.Bodybrassspindlestopcockofapproved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mmlongwithbrasscouplingatoneendandmakingplunber joints etc. all complete as per specification and direction of E/I.
98Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever requiredSize 450x300x150 mm
99Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete Flexible pipe32 mm dia
100Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
101Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
102Providing and fixing C.P. brass bib cock of approved qualityconforming to IS:8931 : 15 mm nominal bore
103Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore
104Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal boreProviding and fixing toilet paper holder :
105C.P. brass
106Providing and fixing flanged cleanout plug with M.S flanged tailwith100 mm dia Pipe
107Providing and fixing uplasticised PVC connection pipe with brassunions : 45 cm length 15 mm nominal bore
108Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete
109Supplying fitting and fixing H.C.I Pipes with ear of approve makes……….do………E/I A)H.C.I Single luction with door but without earexcept socket 100 mm dia
110(B)H.C.I Heal rest bend 100 mm dia
111SUPPLYING ALL TOOL AND LABOUR AND CUTTING CHAJJA CORNICEFOR LAVING h.c.i. pipes and making good the ………..do………E/I
112Cutting drain width wise above G.L. for laying H.C.L. pipes andrestoring brick work in CM (1:4)…………………DOE/I
113Making holes in walls for laying H.C.I. pipes and restoring the sameafter pipe laying ……………… do…..E/I 125 MM dia
114SUPPLYING MATERIALS AND LABOUR FOR PAINTING THE EXPOSADEh.c.i. pipes and fitting ………….do………E/I 50 mm dia
11580 mm dia
116100 mm dia
117Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 110 mm dia (OD) SWR Pipenominal
11825 mm Dia Nominal outer Dia pipe
119Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes
12020 mm nominal dia Pipes
12125 mm nominal dia Pipes
122Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 32 mm nominal bore
123Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality25 mm diameter pipe
124Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New WORK32 mm nominal bore
125Providing and fixing in position 25 mm diameter mosquito proofcoupling of approved municipal design
126Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
127Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clayF.P.S. (non modular) bricks of class designation 7.5
128Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete150 mm dia. R.C.C. pipe
129Providing and placing on terrace polyethylene water storage tank…………..doe/i
1304.5 KG Carbon dioxide extinguisher IS mark with high pressuredischarging tube horn control valva CCE aproved cylinder
1316 kg mono ammonium phosphaste(ABC) TYPE cartridge operatedextinguishers
132CARRAGE OF MATERIALS SAND
133CHIPS
134Bricks
135Add 18% GST
136Add1% LC

AI Tender Summary

OUR REF NO 39117682
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 17-08-2023
Authority
Authority Name Zilla Parishad
Work Description Construction Of Block Public Health Unit Building, At-Tandwa
Basic Detail
Tender No NIT NO. 17/23-24
Bidding Type Tender
Location
City tandwa
State Jharkhand
Key Dates
Publish Date 11 Aug 2023
Submission Date 17 Aug 2023
Open Date 19 Aug 2023
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 1 Lakhs
Exemption Not Available
Document List
TenderDocument.pdf
Tendernotice_1.pdf
3ed3c7cd-bce9-4884-b021-306489bd916a.html
BOQ_99871.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 19, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

html

3ed3c7cd-bce9-4884-b021-306489bd916a.html

xls

BOQ_99871.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender