Tender For Special Repair Replacement Of Summer Cooling Appliances Against Ber And Other Sanctioned Work Under Ge (Af) Adm Area At Af Station Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Special Repair Replacement Of Summer Cooling Appliances Against Ber And Other Sanctioned Work Under Ge (Af) Adm Area At Af Station Agra. Submission Date for this Tender is 30-08-2023. Air Conditioner Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39115491
Corrigendum : Tender For Special Repair Replacement Of Summer Cooling Appliances Against Ber And Other Sanctioned Work Under Ge (Af) Adm Area At Af Station Agra
Open Tender
Indian
Uttar Pradesh
agra
30-08-2023

Tender Details

Tender For Special Repair Replacement Of Summer Cooling Appliances Against Ber And Other Sanctioned Work Under Ge (Af) Adm Area At Af Station Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Aug-2023 Amendment01 BOQ 30-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 69600.0 /-
Tender Value
INR 34.80 Lakhs /-

BOQ Items

Name of Work:SPL REPAIR/ REPLACEMENT OF SUMMER COOLING APPLIANCES AGAINST BER AND OTHER SANCTIONED WORK UNDER GE (AF) ADM AREA AT AF STATION AGRA
Sl. No. Item Description
1Taking down spilt type AC indoor/outdoor units/Window type ACwith all accessories including copper pipe, drain pipe etc complete and deposit the MES store yard.
2Supply, installation, testing and commissioing high wall spilt unit indoor & outdoor complete 1.5 TR with invertor technologyin white colour single phase, AC 230 Volts, 50 Hz, 5 Star rating and EER 5.2with cordless remote control unit and in built stablizer complete all as directed. Notes : - (a)Copper pipes with insulation should be 3mtr length. (b)Cost of rounded copper cable 2.5 Sqmm 4 coreoutdoor to indoor unit included in quoted rate. (c) Indoor unit to socket cable length should be min 3 mtr includingAC top. (d) Manufacturer warranty - 01 Year on product, 10 Year compressor and 5 Year PCB Warranty. (f) Cost of MS stand for installation of outdoor unit shall be included in quoted rate. (g) Civil work shall be included in quoted rates. (h)Installation should be carried through OEM rep. (j)Contractor should sticke the black colour sticker of size 3 to 5 Cm "GE (AF) ADM AREA AGRA" Make :O General Model No ASGG18CETA-B/ Daikin Air conditioning Model No JTKJ50UV16U (5*1.5 Ton)/ Carrier Model No CAI18N5R31W1 Copper condenser).
3Supply, installation, testing and commissioing high wall spilt unit indoor & outdoor complete 2 TR/2.2, invertor technologhyin white colour single phase AC 230 Volts, 50 Hz, 5 Star rating and EER 5.2with cordless remote control unit and in built stablizer complete all as directed. Notes : - (a)Copper pipes with insulation should be 3mtr length. (b)Cost of rounded copper cable 2.5 Sqmm 4 coreoutdoor to indoor unit included in quoted rate. (c) Indoor unit to socket cable length should be min 3 mtr includingAC top. (d) Manufacturer warranty - 01 Year on product, 10 Year compressor and 5 Year PCB Warranty. (f) Cost of MS stand for installation of outdoor unit shall be included in quoted rate. (g) Civil work shall be included in quoted rates. (h)Installation should be carried through OEM rep. (j)Contractor should sticke the black colour sticker of size 3 to 5 Cm "GE (AF) ADM AREA AGRA" Make :O General Model No ASGG24CETA-B /Daikin Air conditioning Model No JTKJ71UV16U/ Carrier Model No CAI24N5R31W1 Copper condenser.
4Supply, Installation, testing and commissioning top freezer refrigerator of capacity 195 to 207 litreBEE 5 star ratedInverter techonology, 230 Volts, 50 Hz single door complete all as specified and directed :- Note : Contractor shall submit the warrenty card of 01 year on product and 10 years on compressor as given by manufacturer. (b) Base frame for installation of refrigerator is also included in quoted rate. Make:- LG Model No GL-D211HBCZ/ Samsung Model No RR21C2H25RZ/HL/ WHIRPOOL Model No 230 IMPRO PRM5S INV
5Supply, Installation, testing and commissioningtop freezer refrigerator of capacity 300 to 325 litreBEE 5 star ratedInverter technology, 230 Volts, 50 Hz double door complete all as specified and directed. Note : Contractor shall submit the warrenty card of 01 year on product and 10 years on compressor as given by manufacturer. (b) Base frame for installation of refrigerator is also included in quoted rate. Make:- LG Model No GLD322JPZZ/HAIER Model No HEB-333DS-P/WHIRPOOL Model No FP 313D PROTTON ROY STEEL ONYX
6Supply, Installation, testing and commissioningtop freezer refrigerator of capacity 360 litreBEE 2/3 star ratedInverter technology, 230 Volts, 50 Hz double door complete all as specified and directed. Note : Contractor shall submit the warrenty card of 01 year on product and 10 years on compressor as given by manufacturer. (b) Base frame for installation of refrigerator is also included in quoted rate. Make:- LG Model No GL-T382VESX/WHIRPOOL Model No IFINV CNV 375ELT (3S) GERMAN STEEL/ Samsung Model No RT39C5532BS
7S&F 6 mm copper tubing refrigerant pipe of size 5/8 inch dia of superior quality for refrigeration suction/discharge line with foam inslulation suitable for spilt type air conditioner complete all as specified and directed.
8S&F 6 mm copper tubing refrigerant pipe of size 1/2 or 1/4 inch dia of superior quality for refrigeration suction/discharge line with foam inslulation suitable for spilt type air conditioner complete all as spd and directed.
9S&F PVC flexible transperant pipe 15mmdia fixed to wall or on roof complete all as specifiedand directed.
10Supply, install and testing offully automatic Humidifier capacity 30 Ltr tank to control the humidity within range ( 55% +5% RH) for room size of 20 m x 12 m x 5.5 m (approx) with already installed Packaged type AC of Cap 11 TR x 3 Nos (02 Nos working and 01 No standby), 4400 CFM each and available room temperature 230C + 50C. Technical Specification : 1. Humidier Techonology - Ultrasonic 2. Moving Part - Only Fan for air circulation 3. Internal adopting intergrated type ultrasound machine, no international drive, low noise, producing certain negative ion and low failure rate. 4. The output for grain diameter only be 1-10 u. 5. The stainless steel body, standard filling water mouth, swtich and outlet water spill, including nozzeles to be automatic filling water. 6.Automatic control water level. 7.High atomization efficieny (nearly 100%) producing small and evern fog. quickly meets the requirement of the relative humidity thus saving water. 8.Droplet size : steamsize droplets. One micron droplets allow for immediae evaporation like steam.Competitive spray nozzeles system creat upto 20 micron droplets. 9.Health- all dissolved liquids are removed from water feeding into ultrasonic. 10. RH Accuracy - ultrasonic provided instant on-off of mist.As soon as ghe air strays from the relative humidity set point, an ultrasonic humidifier instantly turns on.
1111.Ultrasonic humidifier construction with tankmade from 1.2mm SS sheet (304L), welded construction, Top Openable with SS Bolts and mist output nozzles with 22 Guage GI sheet enclosure duly epoxy painted control with 2 Nos. (double safety) 12. Level switch for low level. 13. High voltage cut-out 14. Filter assembly. 15. Colling fan - 03 Nos. 16. Motorized valve and timer for auto flushing. 17.Mist outlet fan. 18.Control panel Step down transformer with relay, contractor, MCB, Fuse card, on/off switch with light, indication light for drain valve, Humidity off, supply on, low level. 19. Single Phase. 20. Provision of suitable size copper cable forload of 1KW to 2KW\\ from maint distribution panel to Humidifier complete.
12Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing "medium grade" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed.
13S&F 20 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
14M&L for point wiring complete for one socket point controlled by one, one way 16 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 2.50 sqmm nominal cross sectional area single core drawn in and including minimum 25 mm dia "medium grade" PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 2.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
15S&F switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
16S&F socket outlet, flush type, single pole, 2 in 1, 6pin 15/16 Amp, 230 volts complete all as specified and directed.
17S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 8 way,including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
18S&F MCB single pole 240 volts, "C" curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
19S&F MCB SPN 240 volts, "C" curve of rating 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
20S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia "medium grade" PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
21Supply & fixing MS flanged column pipe heavy duty complete with all jointing material of size 65 mm (length of pipe shall be as required at site)complete all as specified and directed.
22S&F Cast iron 65 mm bore sluice valve class PN-1.6 heavy duty both side flanged conforming to IS-14846 2000 ISI marked with stainless steel spindle and iron wheel head complete with rubber gasket packing, nuts, bolts and washers as required at site all as specified and directed.
23S&F Cast iron non return valve ISI marked 100 mm dia heavy duty both end flanged with suitable size of nut bolt washer complete all as specified and directed.
24Supply, installing, commissioning and testing submersible non clog sewage pump set and motor 5 HP all as per IS-325, suitable for working with 3 phase, 415 Volts, 50 Hz, 2900 RPM, AC electric supply having solid handling capacity upto 100 mm, discharge 625 LPM at 16 mtr head incl. suitable size wire/ steel rope for hanging arrangement complete all as specified and directed. Make :- Kirloskar/ KSB/ Crompton
25S&F cast ironfittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets orsocket and spigot) collars, caps and plugs for spigot and socketed end pipe of 200 to 300 mm bore complete all as specified and directed.
26Supply, installation, testing and commissioning pedestal type LT cubical panel indoor type made out 2.0 mm thick CRCA sheet with aluminium bus bar of 100 Amps 4 Nos as per IS 8623 with single panel dust/vermin proof front operated double shuttered with locking arragnements complete along with fixing materials such as bolts, nuts and grouting in the cement concrete painting with two coats of synthetic enamel paint over a coat of red oxide primer inside/outside complete including following accessories :- (a) MCCB 4P 63A 16 KA 415V-01 No (incoming) (b) MCCB 4P 32A 10 KA 415V-02 Nos (out going) (c) Star Delts starter suitable for 5 HP pumpsets with over load protection -02 No. (d) Single phase auto preventor with dry run protection -01 No. (e) Digital Voltmeter 0-500 V with selector switch-01 No. (f) Digital Ammeter 0-30A with CTs and selector switches -01 No. (g) Indication lamp RYB LED type set of three -01 set
27M&L for earthing with steel earth plate electrode ofsize 600x600x6mm thick buried directly in ground to a depth not less than 3.25mtr deep below normal ground level with top edge of the earth plate not less than 2.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC chamber, 50mm thick 30 x 30 cm size RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way with angle iron frame allround made of AI 40 x 40 x 4 mm, adequate qty of charcoal dust and salt layers all around the earth plate, including earth workin any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as shown on electricplate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail