Tender For Conversion Of Hp Into Piped Water Supply Schemes Rwss Sadpura,Block Todabhim Distt. Karauli
Tender Value
46.13 Lakhs
Estimated cost
Bid Submission
23 Aug 2023
0 days left
EMD
92260
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Todabhim → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Conversion Of Hp Into Piped Water Supply Schemes Rwss Sadpura, Block Todabhim Distt. Karauli
BOQ
| Sl. No. | Item Description |
| 1 | INSTALLATION P&M,CABLE ,PANEL,GI ASSEMBLY ETC |
| 2 | Supply & Installation of 3 phase ISI marked submersible motor pump set offive star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 3 | 11.2KW (20 HP) & head above 120 mtr. |
| 4 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 5 | Above 10 HP and up to 15 HP |
| 6 | Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. |
| 7 | 3 core 6.0 Sq.mm |
| 8 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 9 | 16.0 Sq.mm, 4 core |
| 10 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. |
| 11 | Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 12 | 200 mm dia |
| 13 | Providing & Lowering in tube well ISI marked GI Pipe “B\" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 14 | 50 mm dia |
| 15 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. |
| 16 | 50 mm dia |
| 17 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 18 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes |
| 19 | 80 mm dia |
| 20 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. |
| 21 | DistributionPipeLine |
| 22 | Earth work in excavation by mechahical means (Hydraulic Excavator )/ manual means intrenchesofrequiredwidthandgradientforlayingandjointingofpipeline including excavation for sockets, and dressing of sides, ramming-of bottoms, depth up to 1.S Mtr. including taking out the excavatedsoil, and then returning the soil as requiredinlayersnotexceeding20cmindepthincludingconsolidatingeach deposited layer by ramming, watering etc. and disposal of surplus excavatedsoil as directed within a lead of 50 Mtr. including required all safety provisions etc.:AII kinds of soil |
| 23 | Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 24 | Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be madefor trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 25 | Bituminous courses |
| 26 | Granular courses |
| 27 | Providing andlaying in position cement concrete M10 gradenominal mix 1:3:6 (1 Cement:3coarsesand:6 gradedstoneaggregate40mmnominalsize)inbase course complete including all material, Iab’our, machinery, lighting, guarding for road restorationwork in trenches of pipe line and chamberwork. MeasurementfoiCC work to be madeas per standard trench width specified in tender document and no extrapaymentshallbemadebemadefortrenchwidthmorethanspecified, complete work as per technical specification and scope of work. |
| 28 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 29 | DI K7 |
| 30 | 80mm Dia |
| 31 | 100mm Dia |
| 32 | Providing, lowering,aligning, fixinginposition inpipe line,CID/FSluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, ThrustPlate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS,Face to face dimensionsas per IS 14846/2000 (amendedup todate) ,Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised‘steelInsersion rubberof black EPDM 6mm thick . Sluicevalvesincludingalljointing&jointingmaterial,labour,testingand commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 33 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 34 | 80 mm HW |
| 35 | 100 mm HW |
| 36 | Providing, lowering, laying, aligning, fixing in positionand jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523-2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material,labour, taxes, testingand commissioningalong with pipe line as per technical specifications anddirection of Engineer-in-charge (excluding earth work). |
| 37 | A/S Tee , Bend, Reducer (All End Socketed) UP to 300m Dia |
| 38 | Making Functional House Tap Connections ( FHTCs ). |
| 39 | Providing HouseholdTap Connectionas pertechnical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electrofusion saddle piece (Completejob).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramtning /compactinginlayersanddisposalofsurplusexcavatedsoilas directed with in a lead of 100 meter ; providing & fixing of all fitting dulyapprovedinach:ordancewithspecificationforpotablewater including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-wayValve(IS:776Mark)orwheelvalve andspecials,below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nomin mldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittingsinthepremlsesforfixingatap/meterbox(excIuding) ,including accessories with flushing, cleaning, disinfecting and testing ofpipelinecompleterequiredformakingofserviceconnection completeinall respectincludinglabourcherges.Theserviceline should be laid at least 45 cm below ground level.Note:Roadcutandrestorationisnotpartofthis itemandpaid seperately. |
| 40 | For connectionwith 20 mm diaMDPE/PPR-Cpipe length up to 05mtr. |
| 41 | P& F Bib cock (IS : 8931 mark), superiorquality of approved make,with foamflow chromeplatedwith completebrassbodyincluding brass handlewith wt 300 to 325 gm.15 mm nominal bore. |
| 42 | Road cutting for hortse hold service connectionin minimumtrench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using aconcretecuttermachinekeepingminimumtrenchwidthand restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in chai‘ge.. |
AI Tender Summary
Tender Timeline
Aug 11, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 23, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 24, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer