Road And Building Department-RBD has published Tender For Construction Of Civil Infrastructure For Installation Of Biomedical Waste Management Equipment At Chc Narasinghpur In The District Of Cuttack For The Year 2023-24. Submission Date for this Tender is 21-08-2023. Waste Disposal Services Tenders in narasinghpur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation of foundation in hard soil with all leads and lifts including dressing and levelling the bed in layers not exceeding 0.3m in depth including dewatering if necessary with cost of all labour and T&P work etc complete as per specification and direction of the engineer-in-charge |
2 | Supplying and filling in foundation and plinth with sand well watered and rammed in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. |
3 | Cement concrete (1:3:6) in foundation and floors using 4cm(1½”) size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers not exceeding 0’-6” thick including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge. |
4 | RCC M-20 usingblack hard granite crusher broken chips of 10mm to 20mm size (10mm 40% and 20mm 60% ) of approaved qualityfrom approved quarry to achieve the minimum compressive strength of 200kg/cm2 250kg/cm2, 3.00 kg/cm2 of 150mm size cubes on 28 days test confirming to codal provision including hoisting lowering and laying concrete in layers not exceeding 15cm thick compacting in vibrators and watering for 28 days including centering shuttering from works finishing the exposed surface smooth providing grooves where necessary including cost conveyance royalty taxes of all materials with all leads and lifts and cost of all labour T&P mechineries required for the work de-watering if necessary compalete in all respect as directed by Engineer-in-charge including dismantling the centering and shuttering but excluding cost conveaynce of MS rod or tor steel & bind wire and labour charges for strengthening cutting beinding binding wilding and tying the grills etc hoisting and placing in positing (to be paid separetely for RCC work) COLUMN BASE |
5 | PLINTH BEAM |
6 | COLUMN & BEAM |
7 | LINTEL |
8 | CHAJJA |
9 | ROOF SLAB |
10 | RCC WELL RING (50MM PRECAST SLAB) |
11 | 75MM COVER SLAB |
12 | Straightening the coiled or bent up M.S. rod / HYSD bars confirming to Gr. S 240 or S 415, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, coping, welded joints, spear bar, chair, stage, hanger andbinding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987. |
13 | Fly ash Brick masonry using Fly ashBricks in FOUNDATION AND PLINTHhaving crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before useincluding splays, cutting, circular moulding, corbelling, champhering and similar such type of works,scaffolding, watering, curing, including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
14 | Fly ash Brick masonry using Fly ashBricks in SUPERSTRUCTURE having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before useincluding splays, cutting, circular moulding, corbelling, champhering and similar such type of works,scaffolding, watering, curing, including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
15 | Fly ash Brick masonry using Fly ashBricks in SUPERSTRUCTURE having crushing strength not less than 75Kg/sqcm in cement mortar (1:4) after immersing the bricks for six hours in water before useincluding splays, cutting, circular moulding, corbelling, champhering and similar such type of works,scaffolding, watering, curing, including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
16 | 20mm thick thick gading plaster over RCC roof including cost conveyance royalties taxes of all materials labour T&P etc complete in all respect as per specification and direction of the engineer-in-charge. |
17 | Providing 16mm thick cement plaster in cement mortar (1:6)finished smooth to inside rough surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smoothwatering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
18 | Providing 12mm thick cement plaster in cement mortar (1:6)finished smooth to out side rough surface of brick walls after racking out joints, scrapping & cleaning the surface, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
19 | Providing 6mm thick cement plaster in cement mortar (1:4)finished smooth in ceiling & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
20 | Supplying fitting and fixing Kotatile(SOMANY, KAJARIA, JOHNSON) in floorsof size 600mmx600mmin floor of approved quality over 25mm thickcement mortar(1:1)of approved make conforming to IS 13755 with application of polymer modified quick set cement based water resistant adhesive conforming to IS 15477 of 3mm thick bed and filling joints with white cement of approved quality including cost of all materials labour T&P etc required for the work all complete as per direction of Engineer-in-charge |
21 | Supplying fitting and fixing Ceramictile(SOMANY, KAJARIA, JOHNSON) in floorsof size 600mmx600mmin floor of approved quality over 25mm thickcement mortar(1:1)of approved make conforming to IS 13755 with application of polymer modified quick set cement based water resistant adhesive conforming to IS 15477 of 3mm thick bed and filling joints with white cement of approved quality including cost of all materials labour T&P etc required for the work all complete as per direction of Engineer-in-charge |
22 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, crital frames for windows, balustrades of stair case and parapet railing made out of M.S Square bar/ flat as per approved drawing and design including making holes in walls and R.C.C structure, wood work etc., and making good to the damages to walls with cement concrete (1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceed 25%) of approved quality with cost of all materials, labour, cost of welding, all T&P, sundries etc. complete in all respect as per specification & direction of the EI.C. (Screws & other hardware required materials to be used in the work shall be of approved quality & specification & shall have to be supplied by the contractor at his own cost.)A. DOOR, WINDOWS |
23 | Providing Cement washing one coatusing cementof approved quality and approved shade including cost conveyance, taxes of all materials all labour & T&P etc. complete as directed by the Engineer-in-charge. |
24 | Finishing wall surface two coats of weather coat over a coat of water bound cement primer with cost, conveyance, taxes, royalities, cost of all labour, T&P etc. complete as per direction and specification of Engineer-in-charge. |
25 | Distempering two coats to wall in all hiehgts with distemper of approved shade on to give and even shade including cost of distemper all labour T&Petc complete in all respect as per the direction of the Engineer-in-charge. |
26 | Painting two coats with approved synthetic enamel paints to M.S. window and verendah grill overwahs in sand paper or iron paper received to paints smoothly over coat of primer including cost, conveyance, taxes, cost of all labour as per direction and specification of Engineer in charge |
27 | Back filling with excavated earth in layers not exceeding 150mm thick including watering ramming, cost conveynace of water and cost of all labour T&P required for the work etc complete (measurement will be taken on finished compacted section only) |
28 | E.I. work;;Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as arth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire- Finolex/ L&T / Anchor / Havels/Polycab or eq. model ) (Make of switch-Anchor Roma/Legrand/Panasonic or eq. model) Group-A |
29 | Group-B |
30 | Group-C |
31 | Separate Point wiring for 5 / 6 amp modularsocket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular one way type switch ,phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVCinsulated single core multistrand copper conductor for loop earthing etc. as required. ( Make of wire- Finolex / L&T / Havels/Anchor/Polycab or eq) (Make of switch-Anchor Roma/Legrand /Panasonic or eq. model) |
32 | Supply and fixing of 5Amp modular switch and socket on existing board (Make of switch-Anchor Roma/Legrand/Panasonic or eq. model) |
33 | Supplying and fixing of metal box of Modular G.I box for 6 module 18 SWG on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15 / 16 amps modular socket outlet and 15 / 16 amps modulartype switch, connection, painting etc as required.( Make of wire-Anchor/ Finolex / L&T / Havels/Polycab or eq) (Make of switch-Anchor Roma/Legrand /Panasonic or eq. model) |
34 | Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulatedsingle core multistrand copper conductoras earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL/Polycab or eq model) 2 X 2.5 sq.mm +1 X 1.5 sq.mm-do- |
35 | 2 X 4 sq.mm +1 X 1.5 sq.mm -do- |
36 | 4 X 6 sq.mm + 2 X 2.5 sq.mm 32 mm dia |
37 | 4 X 10 sq.mm + 2 X 4 sq.mm -do- |
38 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.) 4way single door |
39 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.) 6 way (6+18) double door horizontal type |
40 | Supply and fixing of 6Amp to 32A rating 240 V/415 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-L&T/C&S/Havells/Legrand or Eq.) 6 to 32 SP MCB |
41 | 40A DP MCB |
42 | 32A 4P MCB |
43 | 63A 4P MCB |
44 | Supply ,installation, testing and commissioning of100/125AmpICTPN main switch main switche (IS 13940 part-3/1993)on existing surface / wall mounting and completer with HRC fuse links, interconnections, earthing , etc as required as per direction of Engineer-in-charge. (Make-Seimens/ HPL/ Anchor/ L&T/Havells/C&S/RK) |
45 | Supplying, installation, of exhaust fan of 300 mm sweep(Make-Havells/almonard/Anchor/Panasonic/Usha or equievalantof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. |
46 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan Make-Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge |
47 | Supply and fixing of modularType fan regulator (Make-Roma/Legrand or Eq.) |
48 | SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 wattcomplete with electronic driver and all other accessories withdiffuser etc as requiredas per direction of Engg.-in-Charge. (Panasonic/ Havells/ Philips/ Crompton/Bajaj or equievalant ). |
49 | S/F of 90wattLEDstreet Light fitting new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic drive including withall acccessories and connection. (Make:Philips/Havells/Crompton/Panasonic or Equivalent as per the direction of Engineer-in-charge) |
50 | Supply of 16sqmm 4 core Allm. armoured XLPE insulated cables ISI marked.(Make- Glowstar/ Polycab/ Havells/KEI or eq. model) |
51 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
52 | S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge.The entire earthing systemshould be Replacement Warranty will be 5 years |
53 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
54 | PH work;_Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.20mm dia PVC ASTM pipe (sch-80) In ground floor |
55 | 25mm dia PVC ASTM pipe (sch-80) |
56 | 32mm dia PVC ASTM pipe (sch-80) |
57 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.In ground floor 250mmthick wall |
58 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In ground floor |
59 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge15 mm dia CP Bib cock(Plaza /Aquatic / Ambermake ) |
60 | 15 mm dia CP Elbow action Bib cock (Plaza/Aquatic /AmberMake) |
61 | 15mm dia CP angle stop cock(Plaza /Aquatic / Ambermake ) |
62 | 15mm dia C.P. Elbow action Pillar cock (Plaza /Aquatic /Amber ) |
63 | 25mm dia PVCfullway valve(Asirvad Make) |
64 | 32mm dia PVCfullway valve(Asirvad Make) |
65 | 15mm dia CP flange |
66 | 15mm dia CP extension piece |
67 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge On the roof of firstfloor 1000litre capacity water storage tanks |
68 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor 110mm dia U-PVC SWR pipe(Ashirbad / Supreeme ) |
69 | 110mm U-PVC door tee |
70 | 110mm U-PVC plain bend |
71 | 110mm U-PVC doorbend |
72 | 110mm dia U-PVC "P" trap |
73 | 110mm dia U-PVC offset with out ear |
74 | 110mm dia U-PVC H.R. Bend |
75 | 125mm dia CP grating |
76 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge 250mm to 375mmthick wall |
77 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge . 600mmx450mmx250mm size porcelain Sink |
78 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. 550mmx400mm size wash hand basin withPlaza Pillar cockand Porcelain Pedestal ( Parryware/ Hind ware /Neyser make ) |
79 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thickon 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge . 600mmx450mm size B.E mirror x minimum 5mm thick(Alpina make ) |
80 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge Acrylicglass shelf with CP guard rails |
81 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mmC.P. Ring Towel Rail |
82 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia |
83 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
84 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.22m dia x 2.10m deep soakway pit |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy