Tender For Additional /Alternator To Washroom At Lcah Rajhans Under Ge Gomantak, vasco-Goa

Military Engineer Services-MES has published Tender For Additional /Alternator To Washroom At Lcah Rajhans Under Ge Gomantak. Submission Date for this Tender is 29-08-2023. Toilet Bathroom Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

39092854
Tender For Additional /Alternator To Washroom At Lcah Rajhans Under Ge Gomantak
Open Tender
Indian
Goa
vasco
29-08-2023

Tender Details

Additional / Alternator To Washroom At Lcah Rajhans Under Ge Gomantak

Key Value

Document Fees
INR 500 /-
EMD
INR 75000.0 /-
Tender Value
INR 37.49 Lakhs /-

BOQ Items

Name of Work: Addn / Altn to washrooms at LCAH Rajhans
Sl. No. Item Description
1Dismantling of floor hearth or wall tiling including cement bedding (not backing) removal serviceable filed to store and rubbish off premises.
2M&Lfor screed bed or bedding layer of mortar 15 mm thick in 1:6 cement plasterfor laying floor finishes
3M&L for matt finishes vitrified tiles of size 600 x 1200, 8 to 10 mm thickas in floors surface jointed and pointed in epoxy grout mixed with pigment to match the shade of tilesincluding 4-8 mm thick ready mix tiles adhesive complete all as specifed and directed.
4M&Lfor rendering of mortar 10 mm thick in 1:4 cement plaster in vertical surfacesfinishes
5M&L for high glossy finishes vitrifed tiles of size 600x 600 mm, 8 to 10 mm thickoveras in backing coat for tiles on vertical surfaces, jointed and pointed in epoxy grout mixed with pigment to match the shade of tilesincluding 4-8 mm thick ready mix tiles adhesive complete all as specifed and directed.
6M&L for finishing wall with textured exterior paint of required shade :(New work two or more coats applied @ 3.28 ltr /10sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10sqm
7Taking down cement plastering on brick or stone walls including raking out joints hacking for key scrubbing down with water etc inside shaftsall as directed by Engr-in-Charge.
8Providing and applying 15mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats of masonry (except stone masonry) and concrete surfaces including providing water proofing compound to the first coat of plaster as per manufacturers specification, inclunding racking out joints, hacking of concrete surface, finishing, curing, and neccesary scaffolding etc complete.
9M&L for 12mm thick ready mix internal plaster of approved make in single coat at all heights and locations surface, watering , finishing, curing, scaffolding etc.complete all as per directions of Engineer-In-Charge.
10Supply only liquid water proofing compound @ 0.200 Ltr per 50 Kg of cement or as per manufacture instruction completed all as specified and directed.
11M & L for Apply a coat of SmartCare Primero with dilution ratio of 1:1 with water maintain a coverage of 100 sq.ft/ltr iclunding removing all durt and filling cruck surface with water proofing chemical mixed with CM 1:3 on wall complete as per Manufacturere specifications
12M&L for applying two coats of Advanced Anti-algal Weather/dampProof 100% Acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane including preparation of New plastered surface complete as per Manufacturere specifications Make: Asian paints Ultima Suprema+ Damp proof or eqlt.
13Preparation of old surface of wall by scrapping / rubbing, applying two coats of Advanced Anti-algal Weather Proof 100% Acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane incl filling cracks surfaces with water proofing compound complete as per Manufacturere specifications Make: Asian paints Ultima Suprema+ Damp proof or eqlt.
14Material & Labour for applying two coat of oil emulsion distemper on oldsurfaces of wall over a coat of primer over wall care putty including perparation of surface by complete removal of distempered and painted surfaces complete.
15M & L 5 mm thick rendering in cement mortar 1:3 onceiling finished even and smooth without using extra cement complete all as specified and directed
16M&L for 3mm thickputty on ceilling surfaces and applying two coat of oil bond distemper and preparation the surfaces complete all as specified and directed
17Demolition of Concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed
18M& L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection or similar places surfaces finished even and fair without using extra cement
19Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal facades etc beyond main r/f.(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying "Rusticide SS" Rust passivator or equivalent as specified in the Brand names to existing r/f bars including wire brushing of r/f, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of "Polyalk Fixoprime" or equivalent as specified in the brand names and cement in proportion 1:1.5 to exising r/f bars as directed complete. Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying "Polyalk EP" or equivalent as specified in the brand names. Polymer modified cement mortar in required porportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering.
20Filling and reinstating of separation cracks: Opening the separation cracks at the junction of RCC and masonry where ever directed and instructed into "V" Grooves 2 to 3" from either side of the cracks by carefully marking areas to be opened up using a cutting machine and skillfully/carefully chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant as instructed and directed. Moistening the cracks, provinding and applyin priming/bonding coat of slurry made out of "Polyalk EP" and cement (or equivalent as specified in the list of brand names) in proporiton 1:1 to surfaces prepared as instructed and directed. Filling the cracks/grooves by providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of brand names) in proporiton 1:5:15 (Polyalk EP: Cement: Graded Sand/Quartz Sand) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed.
21Dismantling of loose portion of concrete from ceiling and S&F of wiremesh of weight 2.5kg/sqm and apply 25mm average thickness in CM(1:4) mixed with liquid integral WPC (complast "X" recommended by the manufacturer with guniting machine at a pressure not less than 5kg/sqm finally rendering 10mm thick plaster in CM (1:4) using WPC (Complast "X" 421 i.e. from M/s Fosroc and nitobound AR from M/S Fosroc or equivalent as approved by GE ) in the proportion recommended by the manufacturer complete all as specified and directed.
22Taking down existing treatment along with PCC padding of any thickness incl removing Old roof any pattern and roughening surfaces of old concrete roof padeling by picking, sweeping clean and washing down with water to remove dust etc. complete.
23M&L for 15 mm thick plastering on brick/concrete surfaces in cement mortar 1:4 using mixed with and including integral waterproofing chemical PIDIPROOF LW mixed in proportion 200 millilitre per 50 Kg cement of DR FIXIT of PIDILTE INDUSTRIES LTD or STP No. 1 (LIQUID)as in padding on roof surface for correcting / making proper slope on roof, surface finished fair and even without using extra cement complete and finished (including up to 4th storey building) complete all as specified and as directed by Engineer-in-Charge. Note: Water proofing compound shall be not measured & not paid separately.
24Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure as per DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, water based primer and applying SmartCare PU Magnum or approved equivalent in two to three coats to achieve a min. thickness of 1.2mm, etc. complete as per Manufacturere specifications
25Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames)
26Taking down Chowkhats or frames exc. 1.5 sq. m but m. exc 4 sqm each with shutters (without taking off shutters from the frames).
27Dismantling of water tanks exc 250ltrs and n exc 500 ltrsand removing to store complete all as specified and directed.
28S&F rotational moulded polyethylene water storage tank (cylindriacal vertical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 500 ltrs including 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball and nipple screwed for iron pipe and fixed complete all as specified and directed.
29S &F 1st class H/W Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at junctions all as specified.
30M&L for PCC type C1 1:3:6 (using 20 mm graded aggregate) for filling the holes of the hold fasts.
31S& F MS flat iron 25 x 3 mm as in hold fast for fixing if chowkats.
32S&F Plain, framed, 1st class hardwood panelled shutters (any number of panels), 40mm with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats.
33M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats
34M& L for Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life
35M&L for Providing “RAJSHRI” Brand Factory Made 25mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured by "RAJSHRI" an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen /Balcony Doors.
36Supply and fix aluminium powder coated frame and shutters for partition/windows/ventilators/doors slidiing/fixed/openable type complete with necessary fittings such as two aluminium handle cum lock for eachj window, roller etc and fixing all as specified and directed by Engineer-in-Charge.
37PCC(1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as infoundation, filling and mass concrete, complete all as specified and directed.
38M & L for precast cement concrete block masonry with solid block exc 10 cm in width and setting in CM (1:6) 1:3:6 type C-1 using 20mm graded stone aggregate.
39S& F venetian image LED bathroom mirror wall mounted anti fog large dimmable lighted with clock,dimension of mirror as per requirement and directed by Engineer-in-Charge
40S&F Glazing with figured glass(Frosted), pin head type, 3mm thick, and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
41S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE.
42S & F Butt hinges, 100 mm cast brass,with mild steel hinge pin, bright polished and fixed, typeB-11
43S&F 100mm tower boltlong brass flush bolt type 2 and fixed flush
44S & F 150 mm long brass handles, cast type polished bright
45S&F300 mm Brass, sliding door bolt with sand or die-cast brass hasp,staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed
46M&L Providing "RAJSHRI" BRAND 30mm thick Prelam Perforated PVC False Ceiling panel made of 5mm wall thickness PVC perforated sheet of size 600mm x 600mm. On 25mm Glasswool. 5.0mm (±0.25) Prelam perforated PVC sheet of Density 600 Kg /Cbm manufactured by an ISO-9001 - 2015 certified company, is stuck with glasswool on one side with suitable adhesive.
47M& L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across theintermediate channel at 457 mm centre to centre.
48M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
49M&L for rounding to edges of granitestone slabs one edge, such as in steps, cooking platform, and other similar situations (inner side only)
50Supply and fixing of Wall hung WC with UF soft close seat cover, Hinges, Accessories set size 380x 520 x 365 mm of cat part No ACS-WHT-87953BIUF of Jaquar
51Supply and fixing of counter top basin,size 610x 475 x 210 mm of cat part No QNS-WHT-7601 of Jaquar
52Supply and fixing of urinal(Top inlet ) with fixing accessories of cat NoURS-WHT-13257 of Jaquar
53Supply and fixing of Pillar Cock Auto closing Systemofcat partNoPRS-031 of Jaquar
54Supply and fixing of Single peace slim concealed cistern with floor mounting frame, Installation kit and S type Drain pipe connection set for wall hung WC without flush control plate of cat part No JCS-WHT-2400FS of Jaquar
55Supply and fixing of of control plate Kubix of Cat Part No JCP-CHR-352415 of Jaquar
56Supply and fixing of Toilet Roll holder of Cat Part No CAN-1151N of Jaquar
57Supply and fixing ofSoap dispenser with glass bottle of Cat Part No AKP-35735P of Jaquar
58Supply and fixing oftowel ring Square of cat part No AKP-35721P of Jaquar
59Supply and fixing of paper towel dispenser of capacity 400-600 C/Z towels material AISI 304 SS finish Satin of Cat Part No PTD-SAP-DT0106CS of Jaquar
60Supply and fixing of hand shower (health faucet ) with 8 mm dia of cat par No 5 ALD-CHR-573 of Jaquar
61Supply and fixing of bottle trap with internal partition 32 of cat part NoALD-CHR-769L300X19 of Jaquar
62Supply and fixing of Double coat hook of cat part NoACN-CHR-1161Nof Jaquar
63Supply and fixing of Sensor concealed type flusing valve for urinal complete set with installation box with control cock (battery operated)of cat part No SNR-STL-51087 of Jaquar
64Supply and fixingbib cock with wall flange of cat part NoQQP-7037PM of Jaquar
65Supply and fixing of Angular Stop Cock with wall flange of cat part No QQP-7053PM
66M&L in repair 75mm diaPVC floor trap with grating including jointing with solvent cement
67S&Fin repair PVC connection 15mm dia and 600/900mm long complete all as specifed and as directed.
68Supplying and laying of 20 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
69Supply and layingCPVC Pipes (SCH-40)of 40 mm dia fitting on walls/ceilings or laying in floors complete all as specified and directed
70Supplying and laying of 25 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
71S & F 110mm bore CPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
72S&F75mm CPVC (SWR) pipes singlesocketed, in any length with rubber ring joints, laid in trenches or in floors.
73S & F 110mm bore CPVC (SWR) bends With acces door any radius.
74S & F 75mm bore CPVC (SWR) bends With acces door any radius.
75Supply & fix 18 mm thick Rajshree Celuka ply or equivalent as approved of grade 1 quality with both side plain or white coloured fixed with stainless steel screws,solvent cement/adhesive to shelf inside the drawer/cabinet including drawer channel, magnetic ballcatch & other all fitting as per manufacturer instructions
76Removing building materials by truck or tractor with using of if necessary JCB machine and trolly load min 3.0 cum each loadforupto 10.00 km including loading, unloading and stacking at the destination and depositing out side defence landall as directed by Engr-in Charge.
77Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses,pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition seperately)andmaking good disturbed surface of walls, floors etc complete all as per the existing finish.
78Material and labour for light/fan point wiring complete as specified with 1100 V grade1.5 Sqmm two runs of single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS, drawn through and includingPVC non metallic conduit(ISI Marked) with all accessories concealed in wall , ceiling, including sunk pressed steelterminal boxes made out of 2 mm thick MS sheet concealed in walls and modular plate,cover suitable for switches, socket, regulator etc including one run of1.5 sqmm single core copper conductor cableFRLS grade as earth continuity wire connected to commonearth and earth dolly including testingcomplete all as specifiedand directed by Engr-in-Charge.
79All as per item No 2 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board.
80Supply and fix modular switch, one way 6 Amp ,1 module
81Supply and fixmodular socket 6 Amp, 2 / 3 pin, 1 module
82Supply and fix of ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks.
83M&L in sub main wiring with 2 runs of2.5 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit includingsuitable size of PVC rigid conduit medium grade as per IS and one run of 2.5 sqmm size PVC insulated copper conductor complete all as specified and directed.
84Supply and fixing LED recess down lights 15 Watts with smart sensor with inbuilt Microvave sensor auto dimming option from 100% to 25%connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete Cat part No-SZRDRMX015-iss Make: Shakti
85Supply and fixingLED mirror lights fitting 10W, 220V,AC decorative box type ,including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to light fitting complete.
86Supply and fixingNero Neon LED strip 7W ,24V IP-68 Warm white suitable mirrorconnecting up with three core flexible copper conductor cable complete.
87Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete, dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge.
88Supply & Fixing in replacement of two waves automatic hand dryer machine 240V, max sensor range 20cm,Blowing volume 90 cum/hr and dry time 15 seconds complete all as specified and directed.Make: Dolphy/Xlerator/Havells
89Supply & fixing Freshener sprayer electric dispenser blackwith timer for toilet specified and directed by Engr-in-Charge.
90Supply & Fixing of wall lights 6 ray oval up-down LED waterproof warm white 12 watts complete all as specified and directed.Make: Dolphy/Xlerator/Havells
91Supply & Fixing sanitary pad dispensing/ burning including flexible hose pipe auto cut off wall mounting typecomplete all as specified and directed.
92Supply & fixingMCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts.
93Supply & fixingMCB, 6 to 32 Amps, single pole neutral, C Series, 10 KA, 240 volts.
94Supply & Fixing sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and directed.