Tender For Special Repair Of Summer Cooling Appliances Against Ber And Addn/Altn To Itor At 9 Sqn In Tech Area At Af Stn Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Special Repair Of Summer Cooling Appliances Against Ber And Addn/Altn To Itor At 9 Sqn In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 08-09-2023. Air Conditioner Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39090088
Corrigendum : Tender For Special Repair Of Summer Cooling Appliances Against Ber And Addn/Altn To Itor At 9 Sqn In Tech Area At Af Stn Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
08-09-2023

Tender Details

Special Repair Of Summer Cooling Appliances Against Ber And Addn/Altn To Itor At 9 Sqn In Tech Area At Af Stn Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Aug-2023 Corrigendum II Date 01-09-2023
2 22-Aug-2023 Corrigendum I BOQ 01-09-2023
3 01-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 93200.0 /-
Tender Value
INR 46.56 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR OF SUMMER COOLING APPLIANCES AGAINST BER AND ADDN/ALTN TO ITOR AT 9 SQN IN TECH AREA AT AF STN GWALIOR
Sl. No. Item Description
1Supply, install, commissioning and testing of window type Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit ,minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make :- Blue Star / Voltas/Carrier/Daikin/Hitachi. (a) Compressorwithmotor, air cooled copper condenser with fan and motor .unitshall be installedout side the building. (b)Refrigerant copper pipe for suction and discharge line with insulation ,control valves & safety accessories including control wiring for condensing unit with suitable size of copper cable. (c)Making good the disturbed surface to match the existing surface after plugging the hole etc. (d)PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of window AC duly painted and making good to disturbed surfaces suitable for installing of 1.5 TR window AC complete all as specified and directed. (e)Electrical cable required to connect to voltage stablizer inclusive in above rate.
2Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit ,minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make :- Blue Star/ Voltas/Carrier/Daikin/Hitachi. (a)Indoor unit copper coil with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b)Out door unit comprising . Compressorwithmotor,. air cooled copper condenser with fan and motor .unitshall be installedout side the building/ on roof. (c)Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe& protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d)Making good the disturbed surface to match the existing surface after plugging the hole etc. (e)PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture"s instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f)Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
3Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit ,minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make :- Voltas/Carrier/Daikin/Hitachi/Blue star. (a)Indoor unit copper coil with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b)Out door unit comprising . Compressorwithmotor,. air cooled copper condenser with fan and motor .unitshall be installedout side the building/ on roof. (c)Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe& protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d)Making good the disturbed surface to match the existing surface after plugging the hole etc. (e)PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture"s instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f)Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
4M & L for sub main wiring with two runs of single core 4 Sq.mm for phase conductor and one run of single core 4 Sq.mm as earth wire ofmulti stranded copper conductor FR-LSH PVC insulated unsheathed cable conforming to IS : 694 drawn through in & including PVC casing & capping with fixing accessories on wall/roof surface as per relevent IS standard not less than 25 mm width and all as complete specified and directed. Make - Havells/Mascab/Finolex/Polycab
5Supply and Fixing industrial type socket with plug top, Single pole and netural and earth plug 240V, 20 Amps with steel enclosure and one MCB SPN20 Amps complete all as specified and directed.
6Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed Make:- V-Guard,Blue Bird, AE
7Supply and fixing copper tubing of special annealed pressure copper of size 3/8" bore
8Supply and fixing copper tubing of special annealed pressure copper of size 5/8" bore
9Supply and fixing copper tubing of special annealed pressure copperof size 1/4" bore
10Supply and fixing copper tubing of special annealed pressure copper of size 1/2" bore
11Supply and fixing PVC nylon braided industrial quality drain pipe of 20mm inner bore including fixing accessories on wall/roof etc all as directed
12M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following : (a) One light/ Fan/Exhaust fan/Wall mounted fan point controlled by one way switch.
13(b )One 5 Amps switch socket combination on independent board.
14All as per item No.12.01 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socketpoint as directed.
15S&F switch modular flush type single pole one way 6 Amps,1 module complete all as specifed and directed.
16S&Fmodulerswitch socket 6 Amps -2/3 pin combined 2 module, complete all aspsecified and directed.
17S&F Modular Switch socket 6/ 16 Amps 2/3 Pin combined 2 module complete all as specified and directed.
18S&Fmodular fan regulator Step type 120W 2module complete all as specified and directed.
19S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
20Supplying, fixing& testing decorative recess mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Gridceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable ,including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified anddirected. Make :Cat Part No Havells-VENUSNEOHE2XR36WLEDD84PIRSENSOR Racess mounted 2x2 LED or equvlent Philips/CG
21S&F ceiling rose surface backelet ISI marked , 2 to 3 terminal all as specified.
22Taking down carefully existing DB from its original position byunscrewingand making good the disturbed surfaces of walls etc all as directed. complete all as directed by Eng-in-Charge.
23S&F, DB sheet metal enclosure 4 waySingle door SPN. Make:Indoasian /Havells/C&S
24S&F MCB SPN 10 to 40 Amps all as specified and rupturing capacity 10 KA, Make:Indoasian /Havells/ABB
25S&F MCB single pole 5 to 16 Amps all as specified and rupturing capacity 10 KA,Make:Indoasian /Havells/ABB
26S&F, DB sheet metal enclosure 4 way TPN Double door for mounting MCB. Make:Indoasian /Havells/ABB
27Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 160 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specifiedanddirected. Make :- Legrand/Havells/C&S or equivlant
28Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 160 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 100Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specifiedanddirected. .Make :- Legrand/Havells/C&S or equivlant
29Supply, fixing, connecting & testingof sheet metal enclosures single pole and neutralwith a two pinearth plug and socket complete with one single pole 20 amp MCB complete all as specifiedanddirected. Make :- Legrand/Havells/C&S or equivlant
30Supplyand Fix, for MCCB , 4 pole 160 Amps 415 Volts all as specified and repturing capacity 16 KA.complete.Make:Indoasian /Havells/ABB
31Supplyand Fix, for MCCB , 4 pole 100 Amps 415 Volts all as specified and repturing capacity 16 KA.complete.Make:Indoasian /Havells/ABB
32M&L for earthingcomplete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick burried directly in grond earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.50 mtr and below nomal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No-5 conneced to earthing test point all as specified or indicated including testing oncompletion.
33Taking down carefully existing sub main wiring from its original positionand making good the disturbed surfaces of walls etc all as directed. complete all as directed by Eng-in-Charge.
34M&L for sub main wiring in replacement using two single core PVC insulated,unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.Make :- Havells/KEI/Anchor
35M&L for sub main wiring in replacement using two single core PVC insulated,unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.Make :- Havells/KEI/Anchor
36M&L for sub main wiring in replacement using four single core PVC insulated,unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.Make :- Havells/KEI/Anchor
37Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR completed all as specified and as directed.
38Supply and fixing ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE completed all as specified and as directed.
39Supply, install, testing & commissioning of stand alone, all in one type Integrated LED Solar Street Lighting System of 30 W capacity, 3000 Lumen beam angle 135/85, system efficacy > 100, CCT 5700, CRI> 70 with built in high efficiency solar panel of 90Wp mono crystal module & battery cap of 12V, 30 Ah, LiFePO4 type with high efficiency micro processor based charge controller & PIR sensor, should have dusk to down operation & designedback up for 12 hrs at full or with dimming approx 24 hours and lighting system shall be equipped on 6.0 m long pole with base plate and finial taper plug, [nominal bore : 65mm, medium grade ] minimum 3.6 mm thick complete all as specified and directed. Make - Philips (CatnoBRP710 LED 30 CW MR S1 12V LFP AIO Solar Equip IN) / Orient (Cat No. LSSN-30C90-30P)/ Havells Note : a) The 1/6 length of the pole shall be planted on the ground through earth and PCC works. The base for pole foundation shall be 0.6X0.6X0.01 m, foundation for the polebe 0.45X0.45X1.0 m and coping be .015m radius around the pole of 0.03 m long above ground level b) Earth work and PCC works along with form work is demed to be inclueded in the quoted rate c) The manufacturer shall provide unconditional warranty for two years along with battery for solar lighting system excluding pole and contractor shall produce necessary documents for the same before taking any payment from the department.
40Supply in lay PVCcoper cable of size 4 Core 35 Sqmm laid on foor /wall heavy duty complete all specified as and as directed. Note. Connecting the cable at DB and Equiptment with proper size copper cable lugs is demmed to be inclueded in the qouted rate.
41Dismantling and taking down the serviceable Air Conditioner of 1.5/2/3 TR indoor and out door unitwith voltage stabilizer and refixing the same at directed location complete all as specied and as directed. Note: 1. Proper pumping down of refrigirant is the responsiblity of the contractor. Any topping up of refrigirant gas required is included in the quoted rate, 2. Necessary insulation required for copper pipe is included in the quoted rate.
42S&F 16mm thickness acoustic mineral fibre micro perforated finish (Reveal type) ceiling board of600x600mm size fixed over and including pre powder coated GI frame with suspension system (Grid) comprising of T section 25mmx32.5mmx1.6mm size as main runners and wall angle to placed along the wall at desired level of the False ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided at desired distance and making good the dismantling portion complete all as directed.(Make:- GypRoc (Clotex Serino) Saint Gobain, Armstrong(RH99 Dune) or Equivalentas approved by GE)
43S&F "ACOUSTIC PERFORATED PRELAM PVC WALL PANELLING consisting of PVC Perforated panels having wall thickness of 5mm ( ±0.25 ) PVC sheet of Density 600 Kg /Cbm , and the desired thickness of Glasswool/ Rockwool pasted with perforated sheet with suitable adhesive.The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panel on all four sides of the panel. The PVC Strips of 5mm ( ± 0.25 ) thick PVC Sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both the panels, using solvent cement. 900 heat bent strips of 5mm thick PVC sheets of width 75mm x 75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.
44Demoliton of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
45M&L for brick work with sub class "B" bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed.
46M&L for 15mm thick rendering other than fare face of brick/stone masonry wallsin CM 1:6 finished even and smooth without using extra cement all as specified and directed.
47M&L for 15mm thick rendering fare face of brick/stone masonry wallsin CM 1:4 finished even and smooth without using extra cement all as specified and directed.
48M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions andapplying one coat of distemper oil emulsion white or tintedas approved complete all as specifiedand directed.
49M&L for Preparation of newly plaster surface of wall andapplying two coat of distemper oil emulsion over a coat of primer over birla/JK wall care putty as approved all as specifiedand directed.
50M&L for Preparation of newly plastered surface andapplying two coat of weather coat exterior emultion white or tinted over a coat ofprimerand wall putty as approved complete all as specifiedand directed.
51M&L for 25 mm thick PCC (1:2:4) type B-1(20mm graded stone aggt) as inflooring complete all as specified and directed.
52Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
53M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 15mm thick screed bed in CM 1:4. complete
54M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,, in skirting/dado or vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 10mm thick Rendering in CM 1:4. complete all as specified
55Taking down chowkats or frames with shuttersexceeding 1.5 Sqm but not exceeding 4 Sqm each (steel windows & Aluminum Doors) (without taking off shutters from the frames) including builders hardware & glass etc complete all as specified & directed.
56S&F UPVC luxury casement sound proof fixed type windows and frame with double glass glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (6T+12+6T) internal plain and external tinted with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc with lock and key complete weight not less than 32 Kg/Sqm all as directed.
57S&F UPVCsound proof door and frame with double tinted glass glazing 65mm/C65PS3/ Z-SASH,DG INS, TGH (6T+12+6T) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 32 Kg/Sqm all as directed.
58S&FDouble action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified & directed.
59Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in Hard/dense soil complete all as specified & directed.
60M&L for cement concrete 1:4:8 type D-2 (20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified & directed.
61M&L for Cement concrete 1:2:4 type B1 (using 20 mm graded stone agregate) in foundations, filling and mass concrete complete all as specified & directed.
62S&F Steel work in tubular trusses Circular/ squared including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including all necessary welding or bolting complete all as specified and as directed.
63S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins/cleat for purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified & directed.
64S&F for Hand rails, half round or wind ties for roof including securing bolts etc complete all as specified and as directed.
65S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
66Preparing new surface of steel over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified & directed.
67M&L for R.C.C. grade M-25 (design mix) (using 20mm graded stone aggregate) as in lintel Beams and in chajjas complete all as specified and directed
68Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
69M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
70M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
71M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
72M&L for 100mm thick PCC (1:3:6) type C-1(20mm graded stone aggt) as in Plinth protection, surface finished even & fair using extra cement complete all as specified & directed.
73M&L for 75mm thick PCC (1:4:8) type D-2(40mm graded stone agg) as in sub base of flooring complete all as specified and directed.
74S&F 18mm thick Rajshri PVC Celuka ply of both side laminated to make kitchen cabinet shutter/drawer front shutters complete as per specifications and as directed by the Engr in charge complete all as specified & directed.
75S&F auto closing hinges 35mm size including magnetic system andopenable at 110 degree for kitchen cabinets shutters complete all as specified & directed.
76S&FStainless steel handles 100mm size or kitchen cabinets shutters as per specifications and as directed by the Engr in charge.
77S&Fframed work of angles or tees with web and flanges cut to shape , drilled and counter sunk for screw , including bending and welding angles as necessary , gusset plates, riveting , bolting etc such as etcas in door frame etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
78M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, cable duct covers,window-cills, cooking platforms and like in 15mm thick plaster in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
79Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified & directed.
80M&L for 12mm thick Endura designer tiles ofsize n. exc 0.16 Sqm any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry as in floors including 15 mm thick screed bed with bedding layer in CM (1:4) complete all as specified and directed.
81M&L for glazed ceramic Coloured tiles300x 450x 7mm thick in skirting/dado or vertical surface set andjointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement moratar 1:4 complete all as specified and directed.
82Providing & Fixing of Glass Mosaic Tiles on finished plain wall surface 20 x 20mm in all colors, design Fixing in customize design as per direction of engineer in-charge. The glass mosaic tiles to be fixed on surface with the help of approved adhesive applied at the rate of 2.5 kg per Sq.M and grouting for the same, the rate is inclusive of all operation (incl cutting of existing tiles in required patttern and design etc) & material and required pattern approved by engineer in-charge for wall tiling or in skirting/dado etc complete all as specified and directed. Note : Printing of tiles as approved by GE.
83S&F powder coated aluminium frame for partitions,doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron)complete all as specified and directed by Engr-in-Charge
84S&F 5mm thick tinted glass fixed with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed.
85S&F 5-6mm thick ACP board interior grade prelaminated both side with decorative choice laminations andfixed to aluminium frame work or screws to timber frame work complete all as specified and directed
86S&F light weight stylish type venetian blind curtain in windows and doorsandfixed to aluminium/PVC frame work or screws to complete all as specified and directed Approved by GE
87Demolition of RCC cover slab/plateform n.exc. 15 cm thick, reinfircement cut as required to facilitate demolition complete all as specified and directed.
88M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slabfor manhooles and drain etc complete all as specified and directed.
89Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
90S&F 12mm thick frosted toughned glass Fixed to Stainless steel Railing including all necessary fitiings complete all as specified and directed by Engineer-in-Charge.