Housing Urban and Rular Development Government Departments Closing in 0 days TDR #39074310

The Work Of Construction Of Composite School Bairagipur Located In Development Block Sarsavo Of District Kaushambi As Model Abhyudaya Composite School. (Section) - B

Issued by Government Departments · kaushambi, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Aug 2023
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kaushambi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

The Work Of Construction Of Composite School Bairagipur Located In Development Block Sarsavo Of District Kaushambi As Model Abhyudaya Composite School. ( Section ) - B

BOQ

Name of Work: tuin dkS’kkEch ds fodkl [k.M ljlokW esa vofLFkr dEiksftV fo|ky; cSjkxhiqj dks ekWMy vH;qn; dEiksftV fo|ky; ds #i esa fufeZr djus dk dk;ZA ¼ [k.M &c ½
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5 m, disposed earth to be levalled and neatly dressed.All kinds of soil..
2Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P ete required for proper completion of work.
3Providing and laying cement concrete 1:4:8 (1 cement 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
4Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per LS.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows: (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(As per 4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution))SCH.NO.ch-08
5R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc. and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.
6As in item no. 5 above but for slabs (Using 1:1.5.3 Mix concrete)
7First Class brick work in 1:6 cement and coarse sand of 1.25 F.M mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand).
8Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
9Painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @1.7kg/sqm.Approx including cost of fuel wood etc.
10Same as in item No. 9 above but in super- structure above plinth level up to floor two level ( up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement: coarse sand)
11Same as in item no. 12 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
12P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
13Supply & fixing of flush doors commercial quality conforming to 1.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (b) 35mm thick (single leaf doors).
14M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(a) Providing & fixing of hold fasts.
15M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(b) Door/windows& staircase grill.
16M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(c) Z-section windows.
17M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work(d)Angle iron chaukhats 35*35*5.
18Fixing of steel or woodenchaukhats.(a) door chaukhats
1915 mm thick plinth plaster [1 cement : 4 coarse sand]
2012 mm cement plaster in single coat on rough side of single or hal brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth(1) 1 cement:6 coarse sand
2112mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand.
22Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required.
23Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry, but excluding the cost of nosing of nosing of steps etc. complete.25 mm thick with 20 mm nominal size stone aggregate.
24Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete
25Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing. curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm
26Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tilan unta 200x200mml
27Distempering (TWO COAT )with oil bound distemper of approved brand andmanufacture & of required shade on undecorated wall surface to give an evenshade over & including a priming coat with cement primer of approved brand &manufacture such as Berger,J&N, ShalimarAsian paints after thoroughly brushingthe surface free from mortar droppings &other foreign matters & also includingpreparing the surface even with plasterof paris or approvedsynthetic material &sand papered smooth including cost of all materials.
28Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete.
29Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superiorsynthetic enamel such as LUXOL3,HI- glossapcolite superlac, DULUX specifiedbrushing to give an even shade andincluding cleaning the surface of alldirt,dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plantsetc. required for proper completion ofthe work.
30Same as in item No. 32 above but on new wood surface.
31Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed withwater proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming and approved by Engineer-in-charge Including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above.operations to be done in order and as directed and specified by the Engineerin-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
32Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 300mm x 16mm.
33Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 300mm x 16mm.
34Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 100 mm
35Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes.
36Making drain along apron.
37Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without anu pigment.
38Internal w/s and sanitation
39External sewerage
40Internal electrification and power wiring
41Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling. watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
42Filling of carted earth.
43Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P ete required for proper completion of work.
44Providing and laying cement concrete 1:4:8 (1 cement 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
45Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per LS.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows: (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(As per 4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution))SCH.NO.ch-08
46R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc. and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.
47As in item no. 6 above but for slabs (Using 1:1.5.3 Mix concrete)
48First Class brick work in 1:6 cement and coarse sand of 1.25 F.M mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand).
49Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
50Painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @1.7kg/sqm.Approx including cost of fuel if any.
51Same as in item No. 45 above but in super- structure above plinth level up to floor two level ( up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement: coarse sand)
52Same as in item no. 48 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
53Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
54P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
55Supply & fixing of flush doors commercial quality conforming to 1.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (b) 35mm thick (extra for double leaf doors).
56M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(a) Providing & fixing of hold fasts.
57M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work(d)Angle iron chaukhats
58Fixing of steel or woodenchaukhats.(a) door chaukhats
5915 mm thick plinth plaster [1 cement : 4 coarse sand]
6012 mm cement plaster in single coat on rough side of single or hal brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth(1) 1 cement:6 coarse sand
6112mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand.
62Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required.
63Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
64Cement concrete flooring 1:24 (1 cement 2 coarse sand 4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40) mm thick floor)..
65Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 20 mm thick
66Finishing wall with water proofing cement paint of approved make such as Super snowcem, Duracem, Robiance, Guttucem, Supercem quality and of required shade on undecorated wall surface (one coat) over and including one coat white cement primer to give abd even shade after thoroughly after brushing the surface to two coat.
67Distempering (TWO COAT )with oil bound distemper of approved brand andmanufacture & of required shade on undecorated wall surface to give an evenshade over & including a priming coat with cement primer of approved brand &manufacture such as Berger,J&N, ShalimarAsian paints after thoroughly brushingthe surface free from mortar droppings &other foreign matters & also includingpreparing the surface even with plasterof paris or approvedsynthetic material &sand papered smooth including cost of all materials.
68Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superiorsynthetic enamel such as LUXOL3,HI- glossapcolite superlac, DULUX specifiedbrushing to give an even shade andincluding cleaning the surface of alldirt,dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plantsetc. required for proper completion ofthe work.
69Same as in item No. 65above but on new wood surface.
70Providing & fixing stainless steel sliding door bolts ISI marked complete. (a) 300mm x 16mm.
71Providing & fixing stainless steel tower bolts ISI marked complete.(a) 250 mm X 10 mm.
72Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
73Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
74Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without anu pigment.
75Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including, cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or Induction butt welded tubes
76Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
77Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work, Paint to be used should fonfirm the 151 no. 103-1950 (M.S. works).
78Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling. watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
79Filling of carted earth.
80Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P ete required for proper completion of work.
81Providing and laying cement concrete 1:4:8 (1 cement 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
82Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per LS.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows: (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(As per 4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution))SCH.NO.ch-08
83R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc. and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.
84As in item no. 80 above but for slabs (Using 1:1.5.3 Mix concrete)
85As in item no. 80 above but for beam (Using 1:1.5.3 Mix concrete) .
86As in item no. 80 above in Raft foundation and footing with approved stone ballast. (Using 1:1.5.3 Mix concrete) .
87As in item no. 80 above but in R.C.C columns in 1:1.5.3 having strength not less than M-20 .
88First Class brick work in 1:6 cement and coarse sand of 1.25 F.M mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand).
89Same as in item No. 85 above but in super- structure above plinth level up to floor two level ( up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement: coarse sand)
90Same as in item no. 12 but in 1:4 cement and coarse sand mortar in superstructure for wall PWD thickness 12 cms & below brick work.
91Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
92P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
93Supply & fixing of flush doors commercial quality conforming to 1.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick
94M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(a) Providing & fixing of hold fasts.
95M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(b)Providing & fixing of door/windows grill.
96M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work(c)Fabrication of Z-section steel windows.
97M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work(d)Angle iron chaukhats
98Fixing of steel or woodenchaukhats.(a) door chaukhats
99Fixing of steel or woodenchaukhats.(b) window chaukhats
100Fixing of steel or woodenchaukhats.(c) Ventilator chaukhats
10112 mm cement plaster in single coat on rough side of single or hal brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth(1) 1 cement:6 coarse sand
10212mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand.
103Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required.
104Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 200x200mm)
105Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tilan unto 200x200mm)
106Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
107Cement concrete flooring 1:24 (1 cement 2 coarse sand 4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40) mm thick floor)..
108Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 20 mm thick
109Finishing wall with water proofing cement paint of approved make such as Super snowcem, Duracem, Robiance, Guttucem, Supercem quality and of required shade on undecorated wall surface (one coat) over and including one coat white cement primer to give abd even shade after thoroughly after brushing the surface to two coat.
110Distempering (TWO COAT )with oil bound distemper of approved brand andmanufacture & of required shade on undecorated wall surface to give an evenshade over & including a priming coat with cement primer of approved brand &manufacture such as Berger,J&N, ShalimarAsian paints after thoroughly brushingthe surface free from mortar droppings &other foreign matters & also includingpreparing the surface even with plasterof paris or approvedsynthetic material &sand papered smooth including cost of all materials.
111Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superiorsynthetic enamel such as LUXOL3,HI- glossapcolite superlac, DULUX specifiedbrushing to give an even shade andincluding cleaning the surface of alldirt,dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plantsetc. required for proper completion ofthe work.
112Same as in item No. 34 above but on new wood surface.
113Providing & fixing stainless steel sliding door bolts ISI marked complete. (a) 300mm x 16mm.
114Providing & fixing stainless steel tower bolts ISI marked complete.(a) 250 mm X 10 mm.
115Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
116Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes
117Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
118Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without anu pigment.
119Internal w/s and sanitation
120External sewerage
121Internal electrification and power wiring
122Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling. watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
123Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P ete required for proper completion of work.
124Providing and laying cement concrete 1:4:8 (1 cement 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
125Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per LS.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows: (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(As per 4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution))SCH.NO.ch-08
126R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc. and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.
127As in item no. 120 above but for slabs (Using 1:1.5.3 Mix concrete) Ground floor.
128First Class brick work in 1:6 cement and coarse sand of 1.25 F.M mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand).
129Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
130Painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @1.7kg/sqm.Approx including cost of fuel if any.
131Same as itemNo. 122 above but in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms.
132P/F Mid steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
13315 mm thick plinth plaster (1 cement : 4 coarse sand)
13412 mm cement plaster in single coat on rough side of single or hal brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth(1) 1 cement:6 coarse sand
13512 mm cement plaster in single coat on rough side of single or hal brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth(1) 1 cement:6 coarse sand
136Cement concrete flooring 1:24 (1 cement 2 coarse sand 4 graded stone Aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor)
137Cement plaster skirting up to 30 cm height, with coment mortar 13 (1) cement: 3 coarse sand), finished with a floating coat of neat cement 20 mm thick.
138Cement concrete flooring 1:2.4 (1 cement 2 coarse sand 4 graded stone aggregate 12-20mm nominal size laid in one layer nest cement (40mm) thick CC. flooring)
139Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods, gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors,Providing & fixing of hold fast for chaukhats of doors and windows OMS. Flat size 25 x3-300 mm long)
140Providing & fixing of door/windows grill.
141Z-Section steel windows.
142Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints murod and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In charge.
143Providing and fixing ISI marked flush door shutters conforming to IS 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf.
144Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc required for proper completion of the work Paint to be used should fonfirm the ISI no. 103- 1950 (M.S.works).
145Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103- 1950/Wood work).
146Providing & fIxing glass panes with putty and glazing clips in stoel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes.
147Colour washing such as green, blue or buff to give an even shade: New work(two or more coats) with a base coat of whiting(Inner surface & ceiling)
148Finishing wall with water proofing cement paint of approved make such as Super snowcem, Duracem, Robiance, Guttucem, Supercem quality and of required shade on undecorated wall surface (one coat) over and including one coat white cement primer to give abd even shade after thoroughly after brushing the surface to two coat.
149Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: (a) 250mm x 16mm.
150Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete: (a) 250 mm x 10mm
151Providing and fixing ISI marked oxidised M.S. handles conforming to 15:4992 with necessary screws etc. complete (a) 125 mm (a) 125mm
152Internal electrification and power wiring
153Multiple hand washing unit
154W/S and sanitation
155Kitchen garden
156Court yard development

AI Tender Summary

OUR REF NO 39074310
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-08-2023
Authority
Authority Name uttar pradesh Engineering and Labour Co-Operative Federation Limited
Work Description The Work Of Construction Of Composite School Bairagipur Located In Development Block Sarsavo Of District Kaushambi As Model Abhyudaya Composite School. ( Section ) - B
Basic Detail
Tender No 3137
Bidding Type Tender
Location
City kaushambi
State Uttar Pradesh
Key Dates
Publish Date 09 Aug 2023
Submission Date 16 Aug 2023
Open Date 16 Aug 2023
Finance
Tender Value Ref. Documents
Tender Fee 17700
EMD Ref. Documents
Exemption Not Available
Document List
55e15c5e-cc58-4a31-a4ac-82fb0eaed90b.html
BOQ_1387163.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 09, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 16, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.