Tender For Provision Of 3 Phase Power Connection At Babina Cantt., babina-Uttar Pradesh

Military Engineer Services-MES has published Tender For Provision Of 3 Phase Power Connection At Babina Cantt.. Submission Date for this Tender is 11-09-2023. Electrification Work Tenders in babina Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39066095
Corrigendum : Tender For Provision Of 3 Phase Power Connection At Babina Cantt.
Open Tender
Indian
Uttar Pradesh
babina
11-09-2023

Tender Details

Tender For Provision Of 3 Phase Power Connection At Babina Cantt.; 1 Supply , Install, Testing And Commissioning Of Transformer Step Down 11 Kv / 433 Volts3 Phase , 50 Hz 100 Kva , Energy Efficient Level-2 , Copper Winding Oil Immersed And Naturally Cooled Transformer Forout Door Typeuse Connected Delta On Hv Side And Star On Lv Side With Additional Neutral Brought Out, No Load Ratio11 Kv / 433 Volts With Off Load Tap Changer Connected To Hv Side And Provided With Tapping +- 7.5% In Steps Of 2.5% Continueosly Rated For Full Load Temperature Rise Not Exceeding 50 Degree By Thermometer In Oil And 45 Degree C By Resistance Of Windings After Continueos Run At Full Load Rating Complete With Standard Mountings And Terminal Arrangement Sas Per Is- 2026 And Including Submission Of Manufacturer Test Cerifdicate Complete ( Average Ambienttemp 40 Degree C With A Maximum Of 50 Degree C All As Specified And Directed.Note :- ( A ) Lv Cable Box Suitable For Receiving 50Sq Mm 3.5 Core Xlpe Insulatede Cable Of Grade 1100 Volts With 4 Nos Of Copper Terminal Bushings . ( B ) Oil Conservator With Filling Hole Cap Drain Valve And Level Gauge. ( C ) Dehydrating Breather With Connecting Pipe, First Fill Off Dehydrating Agent And Silica Jell. ( D ) Explosion Relief Vent Mounted On Tank With Double Diaphragm And Equiliser Pipe Conection To Conservator Air Space ( Pressure Release Device ) ( E ) Air Relief Plug ( F ) Shut Off Valve Between The Conservator And Bucholz Relay ( G ) Thermometer Pocket 2 ( H ) 100 Mm Dia Dia Thermometer Indicator Having Range 0-120 Degree C Vapour Pressure Type With Maximum Reading Pointer / Max Temperature Indicator ( J ) 150 Mm ( Ms ) Dia Magnetic Oil Level Gauge With Low Level Alram Contacts. ( K ) Two Earthing Terminals On Tank And Tank Cover With Lugs To Suit 32 Mm X 6 Mm Gi Strip ( L ) Rating And Diagram Plate ( M ) Drain Valve And Threaded Adopter. ( N ) Filter Valve With A Threaded Adopter ( Top And Bottom ) ( O ) Two Sampling Valve At The Top And Bottom Of Main Tank ( P ) Inspection Cover ( Q ) Lifting Lugs ( R ) Four Plane Rollers, Bi-Directional , Hinged Type At The Bottom For Shifting Transformer From One Place To Another Place. ( S ) Top Covers Lifting Eyes. ( T ) Double Float Buchoz Relay With Strip And Alarm Contacts. ( U ) Extra Bushing Out Side The Cable Box Foer Providing Independent Earthing ( V ) First Fill Of Transformer Oil ( W ) Shut Off Valve Between Cooling Tubes And Tanknote: The Oil Temp And Winding Temperature Gauges Shall Be Housed On A Ms Box Made Out Of 16 Gauge Ms Sheet. The Ms Box Made Hinged Door Andhaving Glass 3 Mm Thick Front Of The Box And Provision For Entry Of Cables And Compression Glands. 3 M&L For Pcc ( 1:4:8 ) Type D2, 40Mm Grade Stone Aggregate As In Transformer Foundation Complete All As Specified And Directed. 4 Supply Only Chain Linkms Galvanised Fencing Any Size Or Type ( Weight Not Less Than 2.50 Kg Per Sqm ) Complete All As Specified And Directed. 5 Fixing Only Ms Galvanised Fencing Including Lines Wires, Dia Of Chain Link N Less Than 3.5 Mm Any Mesh Any Type To Any Type Strands Rails Straining Bolts Etc Complete All As Specified And Directed. 6 S&F Mild Steel Screw Bolt ( Mechine Made ) With Hexagonal Or Square, Head, Exc 5 Cm But N.Ecx 10 Cm Long With 5 To 10 Mm Dia Of Neck Complete All As Specified And Directed. 7 M&L Round Bars10 Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Includingmild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips, Fc-410-W ( Gde.E-250 ) Quality -A Or Fe 290 ( Gde-E-165 ) Complete All As Specified And Directed. 8 S&F Galvanised 2 Strand Steel Barbed Wire 2.24 Mm Dia Barbed With 2 Mm Dia Barbs At 75 Mm Spacing And Straining And Fixing To Any Type Of Standard Rails Straining Bolts Including Securing Or Tying At Crossing With And Provision Of Galvanised Mild Steel Wire Staples Or Steel Pins Etc Complete All As Specified And Directed.Note -Each Line Of Horizontal / Vertical / Diagonal Wire To Be Measured For Purpose Of Payment. 9 M&L For Structural Ms Frame Work Half Round Or Other Stock Section Including Securing Posts And Stuts In Fencing, Frame Work For Gates Of Substations, Base Frame For Equipments Including Securing Bolts, Posts And Sturts In Fencing Including Cutting And Makeing Shapes As Desired, Drilling Holes, Notching For Wire Cut To Size And Made To The Exisitng Shape Suitable For Fixing Ms Chequred Duct Covers / Door Panels, Including Nuts, Bolts And Washers, Welding / Bracing Works, Bendingcold Or Hot Drilling Holes For Bolts In Any Shapeetc Flat Iron Fillets ( For Securing Wire Mesh Etc ) All Necessary Drilling, Bolting Or Riveting Etc And Similar Work Confirming To Fe-290 Gde E-165 Including Onecoat Of Primer And Two Coats Of Synthetic Enamel Paint To The Entire Steel Surfaces All As Specified And Directed. 10 Supply And Errect Steel Tubular Swaged Poles Type 410 Sp-5511Meter Long Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts & Screws All As Specified And Directed. Note: Earth Work And Pcc Work In Foundation / Pole Coaping Will Be Measured And Paid Separately Under Relevant Items. 11 M&L For Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Complete Including Dismantling Existing Rusted / Unserviceable Cross Arms Complete All As Specified And Directed. 12 S&F New Gang Operated Air Break Switch ( God ) Ht 11 Kv Of 400 Amps Rating, Out Door Type Suitable For Vertical Mounting, Fixed Type Complete With 2 Nos. Silicon Rubber Polymeric Insulator Per Phase, Triple Pole, Mechanically Operated, Mounted On Insulator And Steel Frame, With Operating Mechanism Worked From Ground Level, For Current Rating Upto 400 Amps All As Specified And As Directed 13 S&F New Single Phase Drop Out Fuse 12 Kv, 400 Amps Rating With Single Silicon Rubber Polymeric Insulator Complete All As Specified And Directed. 14 Supply And Install Lightning Arresters Explusion Type Suitable For 11000 Volts Complete With All Fittings, Transmission Class, Discharge Capacity 65 Ka Includingcomplete With All Fittings Complete All As Spcified And As Directed. 15 M & L For Earthingcomplete With Copperl Earth Plate Electrode60 X 60Cm X 3.15Mm Thick Burried Directly In Ground Vertically To A Depth Not Less Than 2.25 Mtr Deep Below Gl With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Gl And Connected To Earth Plate . Earth Plate Surrounded By 15 Cm Thick Packed Layers Of Charcoal Dust And Common Saltupto 1.5 Meter Depth All Around The Earth Plate And Connected To Earth Leadof Copper Strip 20X3 Mmby Means Of Bolts, Nuts, Check Nuts And Washers Of Galvd Iron Or Steel And Thimbles And Other End Of The Earth Wire Connected To Db And Protected By Galvanized Iron Or Steel Pipe Light Grade 15 Mm Bore And Water Pipe 20Mm Bore Gi Medium Grade With Funnel And Wire Mesh, Including All Necessary Excavation And Earth Work Pcc Chamber In Cement Concrete 1:3:6 Type C-2 And Rcc Cover And All As Shown In Electrical Plate No 3 Of Mes Schedule Pt I Of2009 And Also Including Making Test Point For Testing Of Earthingmade Out Ofgun Metal Or Phosphorous Bronge Size 75X75x25 Mm Complete All As Specified And Directed. Note : ( A ) Rcc Pit Cover Shall Be Pre-Cast Of Rcc ( 1:2:4 ) Type B-I , 80Mm Thick Reinforced With Xpm Weighting Not Less Than 4 Kg / Sqmmin Lieu Of Ci Cover. ( B ) Charcoal Dust And Commonsaltupto 1.5 Meter Depth Shall Be Filled In Layers Of 15 Centimeters All Around The Earth Plate Inside Earth Pit .On Testing After Completion Of Earthing If Desired Earth Resistance Is Not Achieved , The Earthing Will Be Redone At No Extra Cost To Obtain The Desired Earth Values 16 Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Taking Out / Laying Cables In Soft / Loose Soil Complete All As Specified And Directed. 17 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm Complete All As Specified And Directed. 18 Removing Excavated Materials Not Exceeding 50 Metres And Depositting Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete All As Specified And Directed. 19 M&L For Painting Over Angle Iron Of Any Size All Specified And Directed. 20 M&L For Painting Over Round Bars / Pipes Any Desc Complete All As Specified And Directed. 21 Excavating In Post Holes ( Or Similar Holes ) Each N Exc 0.5 Cum Getting Out In Soft / Loose Soil Returning, Filling In And Rammimg Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, Complete All Specified And Directed. 22 M&L For Pcc ( 1:3:6 ) Type C2, 40Mm Grade Stone Aggregate As In Post Holes Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-09-2023
2 06-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 17700.0 /-
Tender Value
INR 8.85 Lakhs /-

BOQ Items

Name of Work:PROVN OF 3 PHASE POWER CONNECTION AT BABINA CANTT
Sl. No. Item Description
1Supply ,install, testing and commissioning of transformer step down 11 KV/433 volts3 phase , 50 Hz 100 KVA , energy efficient LEVEL-2 ,copper winding oil immersed and naturally cooled transformer forout door typeuse connected delta on HV side and star on LV side with additional neutral brought out, No load ratio11 KV/433 Volts with OFF LOAD TAP CHANGER connected to HV side and provided with tapping +- 7.5% in steps of 2.5% continueosly rated for full load temperature rise not exceeding 50 degree by thermometer in oil and 45 degree C by resistance of windings after continueos run at full load rating complete with standard mountings and terminal arrangement sas per IS- 2026 and including submission of manufacturer test cerifdicate complete ( Average ambienttemp 40 degree C with a maximum of 50 degree C all as specified and directed. Note :- (a) LV Cable box suitable for receiving 50Sq mm 3.5 core XLPE insulatede cable of grade 1100 volts with 4 Nos of copper terminal bushings . (b)Oil conservator with filling hole cap drain valve and level gauge. (c) Dehydrating breather with connecting pipe, first fill off dehydrating agent and silica jell. (d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe conection to conservator air space ( Pressure release device) (e) Air relief plug (f) Shut off valve between the conservator and bucholz relay (g) Thermometer pocket
2(h) 100 mm dia dia thermometer indicator having range 0-120 degree C vapour pressure type with maximum reading pointer / Max temperature indicator (j) 150 mm (MS) dia magnetic oil level gauge with low level alram contacts. (k) Two earthing terminals on tank and tank cover with lugs to suit 32 mm x 6 mm GI strip (l) Rating and diagram plate (m) Drain valve and threaded adopter. (n) Filter valve with a threaded adopter ( Top and bottom) (o) Two sampling valve at the top and bottom of main tank (p) Inspection cover (q) Lifting lugs (r) Four plane rollers, bi-directional , hinged type at the bottom for shifting transformer from one place to another place. (s) Top covers lifting eyes. (t) Double float buchoz relay with strip and alarm contacts. (u) Extra bushing out side the cable box foer providing independent earthing (v) First fill of transformer oil (w) Shut off valve between cooling tubes and tank Note: The oil temp and winding temperature gauges shall be housed on a MS box made out of 16 gauge MS sheet. The MS box made hinged door andhaving glass 3 mm thick front of the box and provision for entry of cables and compression glands.
3M&L for PCC (1:4:8) type D2, 40mm grade stone aggregate as in transformer foundation complete all as specified and directed.
4Supply only chain linkMS galvanised fencing any size or type (Weight not less than 2.50 KG per sqm) complete all as specified and directed.
5Fixing only MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any type to any type strands rails straining bolts etc complete all as specified and directed.
6S&F mild steel screw bolt (mechine made) with hexagonal or square, head, exc 5 cm but n.ecx 10 cm long with 5 to 10 mm dia of neck complete all as specified and directed.
7M&L Round bars10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips, FC-410-W (Gde.E-250) Quality -A or Fe 290 (Gde-E-165) complete all as specified and directed.
8S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. Note -Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
9M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bendingcold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc)all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including onecoat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
10Supply and errect steel tubular swaged poles Type 410 SP-5511meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and directed. Note: Earth work and PCC work in foundation/pole coaping will be measured and paid separately under relevant items.
11M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted/ unserviceable cross arms complete all as specified and directed.
12S&F new gang operated Air break switch (GOD) HT 11 KV of 400 Amps rating, out door type suitable for vertical mounting, fixed type complete with 2 Nos. silicon rubber polymeric insulator per phase, Triple pole, mechanically operated,mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps all as specified and as directed
13S&F New single phase drop out fuse 12 KV, 400 Amps rating with single silicon rubber polymeric insulator complete all as specified and directed.
14Supply and install lightning arresters explusion type suitable for 11000 volts complete with all fittings, transmission class, discharge capacity 65 KA includingcomplete with all fittings complete all as spcified and as directed.
15M & L for earthingcomplete with copperl earth plate electrode60 x 60cm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth leadof copper strip 20x3 mmby means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed. Note : (a) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. (b) Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit .On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values
16Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for taking out/laying cables in soft / loose soil complete all as specified and directed.
17Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
18Removing excavated materials not exceeding 50 metres and depositting where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
19M&L for painting over angle iron of any size all specified and directed.
20M&L for painting over round bars/pipes any desc complete all as specified and directed.
21Excavating in post holes (or similar holes) each n exc 0.5 cum getting out in soft/loose soil returning, filling in and rammimg earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all specified and directed.
22M&L for PCC (1:3:6) type C2, 40mm grade stone aggregate as in post holes complete all as specified and directed.