Tender For Maintenance Of Underground System- 1 1.1Kv Lt Armoured Powercable 3.5X240sqmm 2 1.1Kv Lt Armoured Powercable 3.5X150sqmm 3 1.1Kv Lt Armoured Powercable 3.5X70sqmm 4 1.1Kv Lt Xlpe Cable 3.5X70sqmm 5 1.1Kv Lt Xlpe Cable 4X25sqmm 6 1.1Kv Lt Xlpe Cable 4X16sqmm 7 1.1Kv Lt Xlpe Cable 4X10sqmm 8 1.1Kv Lt Armoured Powercable 2X10sqmm 9 Supply Of Lt Cable Heavy Duty Double Compression Termination Brass Glands And Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 10 1.1Kv Lt Xlpe Cable 3.5X400sqmm 11 1.1Kv Lt Xlpe Cable 3.5X240sqmm 12 1.1Kv Lt Xlpe Cable 3.5X150sqmm 13 1.1Kv Lt Xlpe Cable 4X25sqmm 14 1.1Kv Lt Xlpe Cable 3.5X70sqmm 15 1.1Kv Lt Xlpe Cable 4X10sqmm 16 1.1Kv Lt Xlpe Cable2x10sqmm 17 1.1Kv Lt Xlpe Cable2x6sqmm 18 Supply Of Lt Long Barrel Heavy Lugs Suitable For The Following Cable Sizes: 19 1.1Kv Lt Xlpe Cable 3.5X400sqmm 20 1.1Kv Lt Xlpe Cable 3.5X240sqmm 21 1.1Kv Lt Xlpe Cable 3.5X150sqmm 22 1.1Kv Lt Xlpe Cable 4X25sqmm 23 1.1Kv Lt Xlpe Cable 3.5X70sqmm 24 1.1Kv Lt Xlpe Cable 4X10sqmm 25 1.1Kv Lt Xlpe Cable2x10sqmm 26 1.1Kv Lt Xlpe Cable2x6sqmm 27 Supply Of Smart Street Light Management System With Box, 10-60 Amp. As Per Specifications Complete Set 28 Street Light Management Timer Switch Along With Energy Meter As Per Already Approved Gtp 29 Mcb 63 Amp For Street Light Management Box Double Pole Havells Or Above Quality 30 Supply Of 33 Kv Ring Type Metering Ct 600-300 / 1, Cl0.5 For 33 Kv Rmu 31 Supply Of 33 Kv Ring Type Protection Ct 600-300 / 1, 5P10 For 33 Kv Rmu 32 Supply Of 33 Kv Pt 33Kv / 110Voltfor 33 Kv Rmu 33 Supply Of 11 Kv Ring Type Metering Ct 400-200-100 / 1, Cl 0.5 For 11 Kv Rmu 34 Supply Of 11 Kv Ring Type Protection Ct 400-200-100 / 1, 5P10 For 11 Kv Rmu 35 Supply Of 11 Kv Pt 11Kv / 110Volt For 11 Kv Rmu 36 Supply Of Air Circuit Breaker, 50 Ka, 4 Pole Fixed Manual Type, Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-2000 Ampere ( Abb ) As Per Approved Gtp For Css 37 Supply Of Mccb, 4P 50 Ka Fixed Manual Type Microprocessor Based Release With O / C, E / F & S / C Protection-400 Ampere ( Abb ) As Per Approved Gtp For Css 38 Supply Of Mccb, 4P 50 Ka Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-250 Ampere ( L&T, Havells, Abb ) As Per Incoming In Lt Distribution Box 39 Supply Of 400Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Incoming & Outgoing ( L&T, Havells, Abb ) As Per Approved Gtp 40 Supply Of 100Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approved Gtp 41 Supply Of 63 Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approved Gtp 42 Supply Of Series Trip, Self-Powered Microprocessor Based Numerical Over Current Relay ( Idmtl + Inst. ) . O / C For Css ( Ashida Make ) As Per Approved Gtp 43 Supply, Ofal Bus Bar Of L.T C Pannelof Size50x5mmfor 3Phase + N, Off Standard Size. 44 Supply Of Ht Cable Termination Kits / Straight Through 45 33 Kv ( E ) Xlpe Ht Cable J / Ktype 3 X 400 Sq.Mm ( O / D ) Type ( Make Raychem 3M ) 46 33Kv ( E ) Xlpe Ht Cable 3X400sqmm ( Straight Thro ) ( Make Raychem 3M ) 47 33Kv Touch Proof Termination Kits 3X400sq Mm ( I / D ) Type ( Suitable For 33Kv ( Rmu ) ( Make Raychem 3M ) 48 33 Kv ( E ) Xlpe Ht Cable J / K 1 X 630 Sq.Mm ( Outdoor ) ( Make Raychem 3M ) 49 33Kv ( E ) Xlpe Ht Cable J / K1x630sqmm ( Straight Thro ) ( Make Raychem / 3M ) ) 50 33Kv Touch Proof Termination Indoor Kits 1X630sq Mm ( Suitable For 33Kv ( Rmu ) ( Raychem / 3M ) 51 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Indoor ) ( Raychem 3M ) 52 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Outdoor ) ( Raychem 3M ) 53 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Straight Thro ) ( Raychem 3M ) ) 54 Supply Of Lt Cable Termination Kits / Straight Through 55 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X400sqmm 56 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X240sqmm 57 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X150sqmm 58 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X70sqmm 59 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X50sqmm 60 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 4X16sqmm 61 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 4X10sqmm 62 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 2X10sqmm 63 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 2X6sqmm 64 1.1 Kv Cable Kit Size For Cable Of Size 4X16sqmm, 4X10 Sqmm / 2X10sq Mm / 2X6sq Mm Complete Set Including Mastic Tape Complete 65 Supply Of Hdpe Pipefor Laying 11Kv & L.T Cable 66 ( A ) 100Mm 67 ( B ) 75 Mm 68 ( C ) 50Mm 69 Supply Of Lt C Pannel 70 Supply Of T-Connector For 11 Kv D / P 71 Supply Of Mastic Tape 72 Supply Of Flr 73 Supply Of Wrsm Recron Sheet For Covering Minor Cuts In Cable 74 Supply Of T-Connector For 33 Kv D / P 75 Total ( A ) 76 Erection Work 77 Routine Maintenance, Preventive Maintenance Of Complete Network Which Includes Routine Inspection Of All Equipments ( With Thermovision Camera Where Ever Applicable ) , All Kinds Of Panels, Transformers, All Types Of Overhead Structures, Tightening Of Joints / Lugs, Cable Health Monitoring, Maintaining Record / Log Book / Photos. As Per Direction & Shedule Provided By Officer In Charge. 78 ( A ) :-Digging Of Pit For Replacement Of Damage 33 Kvkit / Straight Thruoght& Removed Old Existing Damage J / K 79 ( B ) :-Digging Of Pit For Replacement Of Damage 11 Kv Kit / Straight Thruoght& Removed Old Existing Damage J / K 80 ( C ) :-Digging Of Pit For Replacement Of Damage 0.4Kvkit / Straight Thruoght& Removed Old Existing Damage J / K With Supply 81 ( A ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( 33Kv And Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 82 ( B ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( 11Kvand Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 83 ( C ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( Lt ) And Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 84 C-Consumer S / C 85 ( A ) :-Digging Of Pit For Damage Consumer S / C 86 ( B ) Jointing Of Damage Consumer, S Cable ( Including Jointing Material ) 87 ( C ) :-.Back Filligof Pit After Jointing / Fixing Of Consumerservice Cableand Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 88 Under Grounding Of All 33 Kv Lines And Other Related Works Under The Project Area 89 Jointing / Replacement Of Damage Or Burnt / Laying Of Ht Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 90 33Kv ( E ) Xlpe Ht Cable 3X400sqmm 91 Replacement Of Damage Or Burnt / Laying Of Ht Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 92 11Kv ( E ) Xlpe Ht Cable 3X300sqmm 93 Erection, Testing, Replacement Of Damage Or Burnt And Commissioning Of Ht Cable Termination Kits / Straight Through 94 33 Kv ( E ) Xlpe Ht Cable 3 X 400 Sq.Mm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 95 33 Kv ( E ) Xlpe Ht Cable 1 X 630 Sq.Mm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work Including 96 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work Including 97 33Kv Touch Proof Termination Kits 3X400sq Mm ( Suitable For 33Kv ( Rmu ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, 98 33Kv Touch Proof Termination Kits 1X630sq Mm ( Suitable For 33Kv ( Rmu ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, Duly Plumbing 99 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Indoor ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, Duly Plumbing. 100 33Kv ( E ) Xlpe Ht Cable 3X400sqmm ( Straight Thro ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 101 33Kv ( E ) Xlpe Ht Cable 1X630sqmm ( Straight Thro ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 102 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Straight Thro ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 103 Repairing Of 33 / 11 Kv Rmu Door With Locking Arrangement & Gasket / Rubber Around The Panel Door.With Tightness Ofindoor Joints In 33 Kv / 11 Rmu & Css With Washers 104 Replacement Of Phase Indicators, With Supply 105 Replacement Of Phase Sensors With Supply 106 Rewiring / Repairing Of Internal Connection In 33 / 11 Kv Rmu & Css For Any Malfunctioning ( Supply Wire & Lugs ) 107 Refilling Of Sf6 Ges In 33 / 11 / Css Rmu Includinmgsf6 Ges Supply 108 Replacement / Errection Of Damaged Motor For Spring Charging For 33 / 11 Kv Rmu Including Supply And Fixing Abb Make 109 El Machanisam For Rmu Brakerincluding Supply Andfixing Abb Make 110 33 Kv Rmu Bushing ( 3 No. ) Including Supply Andfixing Abb Make 111 11 Kv Rmu Bushing ( 3 No. ) Including Supply Andfixing Abb Make 112 Tripping Coil 24 V Dc Including Supply Andfixing Abb Make 113 Closing Coil 24 V Dc Including Supply Andfixing Abb Make 114 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Of 33 / 11 Kv Ring Type Metering / Protection Ct For RmuS 115 Earthing For Dtr , Rmu, Css And Lt Feeder Panels 116 Installation / Replacement Of Chemical Earthing Station As Per Is 3043 Complete With Gi Earthing Electrode , Bentonite, . Conductor Upto Test Link, Test Link, Earthing Chamber, 450X450 Mm C.I. Manhole Chamber Etc. 117 Replacement Of Damage Or Burnt / Laying Of Al Conductor Pvc Insulated1.1 Kv Grade Armoured Lt Power Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 118 1.1Kv Lt Armoured Powercable 3.5X400sqmm 119 1.1Kv Lt Armoured Powercable 3.5X240sqmm 120 1.1Kv Lt Armoured Powercable 3.5X150sqmm 121 1.1Kv Lt Xlpe Cable 3.5X70sqmm 122 1.1Kv Lt Xlpe Cable 4X25sqmm 123 1.1Kv Lt Pvc Cable 4X16sqmm 124 1.1Kv Lt Pvc Cable 4X10sqmm 125 1.1Kv Lt Pvc Cable 2X6sqmm 126 1.1Kv Lt Armoured Powercable 2X10sqmm 127 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Lt Cable Heavy Duty Double Compression Termination Brass Glands And Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 128 1.1Kv Lt Xlpe Cable 3.5X400sqmm 129 1.1Kv Lt Xlpe Cable 3.5X240sqmm 130 1.1Kv Lt Xlpe Cable 3.5X150sqmm 131 1.1Kv Lt Xlpe Cable 4X25sqmm 132 1.1Kv Lt Xlpe Cable 3.5X70sqmm 133 1.1Kv Lt Xlpe Cable 4X10sqmm 134 1.1Kv Lt Xlpe Cable 2X10sqmm 135 1.1Kv Lt Xlpe Cable 2X6sqmm 136 Errection Of Lt Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 137 1.1Kv Lt Xlpe Cable 3.5X400sqmm 138 1.1Kv Lt Xlpe Cable 3.5X240sqmm 139 1.1Kv Lt Xlpe Cable 3.5X150sqmm 140 1.1Kv Lt Xlpe Cable 4X25sqmm 141 1.1Kv Lt Xlpe Cable 3.5X70sqmm 142 1.1Kv Lt Xlpe Cable 4X10sqmm 143 1.1Kv Lt Xlpe Cable2x10sqmm 144 1.1Kv Lt Xlpe Cable2x6sqmm 145 Replacement Of Door With Hinges & Locking Arrangement In Lt C Type Distribution Boxes With Supply 146 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Smart Street Light Management System With Box, 10-60 Amp. As Per Specifications 147 Erection , Testing And Commissioning / Replacement Of Damage Or Burnt Street Light Management Timer Switch Along With Energy Meter As Per Already 148 Erection, Testing And Commissioning Of Air Circuit Breaker, 65 Ka, 4 Pole Fixed Manual Type, Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-2000 Ampere ( Abb ) As Per Approved Gtp For Css 149 Erection, Testing And Commissioning Of Mccb, 4P 36 Ka Fixed Manual Type Microprocessor Based Release With O / C, E / F & S / C Protection-400 Ampere ( Abb ) As Per Approved Gtp For Css 150 Erection, Testing And Commissioning Of Mccb, 4P 50 Ka Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-250 Ampere ( L&T, Havells, Abb ) As Per Approved Gtp For Incoming In Lt Distribution Box 151 Erection, Testing And Commissioning Of 400Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Incoming & Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 152 Erection, Testing And Commissioning Of 100Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 153 Erection, Testing And Commissioning Of 63 Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 154 Erection, Testing And Commissioningseries Trip, Self-Powered Microprocessor Based Numerical Over Current Relay ( Idmtl + Inst. ) . O / C For Css ( Ashida Make ) As Per Approved Gtp 155 Checking Of Earth Strip With Welding Joints Are Smooth Painted With Anti Corrosion Paint Or Checking Of Suitable Size Nuts & Washer Used 156 Replacement Of Damage Busbar Of C Pannelincluding Disconnection / Reconnection Ofassociated Consumer 157 Repairing Of Existing Damagefencing 158 Reparing Of Damageequipmentplinth Including Material 159 Erection And Filling Of Lt J / Kit 160 Erection And Fillingheat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X400sqmm 161 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X240sqmm 162 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X150sqmm 163 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X70sqmm 164 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X50sqmm 165 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 4X16sqmm 166 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 4X10sqmm 167 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 2X10sqmm 168 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 2X6sqmm 169 1.1 Kv Cable Kit Size For Cable Of Size 4X16sqmm, 4X10 Sqmm / 2X10sq Mm / 2X6sq Mm Complete Set Including Mastic Tape Complete 170 Laying Of Hdpe Pipefor Laying 11Kv & L.T Cable 171 ( A ) 100Mm 172 ( B ) 75 Mm 173 ( C ) 50Mm 174 Erection Of Lt C Pannel 175 Erection Of T-Connector For 11 Kv D / P 176 Erection Mastic Tape 177 Erection Flr 178 Erection Wrsm Recron Sheet For Covering Minor Cuts In Cable 179 Erection Of T-Connector For 33 Kv D / P 180 Total ( B ) 181 Total ( A+B ) 182 Company / Firm Name 183 Name 184 Designation 185 Date